Loading...
Permit . v. 1 ,... , CITY OF TIGARD MASTER PERMIT 4,0*, 61 & DEVELOPMENT SERVICES PERMIT # • MST97 -0390 - "_i 13125 SW Hall Blvd., Ti ard, OR 97223 (503 639 -4171 DATE ISSUED: 09/30/97 ' PARCEL: ES104DD -02100 SITE ADDRESS...: 12862 SW RIDGEFIELD LN SUBDIVISION •MOUNTAIN HIGHLANDS #2 ZONING: R -4.5 PD BLOCK........... LOT •0 JURISDICTION: Remarks: New SFD PATH I BUILDING — REISSUE: STORIES • 1 FLOOR AREAS BASEMENT...: 837 sf REQUIRED SETBACKS--- RREQUIRED CLASS OF WORK.• HEIGHT • 26 FIRST • 1972 sf GARAGE • 464 sf LEFT : 8 SMOKE DETECTRS: Y TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 0 sf FRONT • 39 PARKING SPACES: 2 TYPE OF CONST.a5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT : 7 OCCUPANCY GRP.:R3 BDRM: 4 BATH: 3 TOTAL------: 1972 sf VALUE..$: 201614 REAR........... :. 18 -- — PLUMBING --- -------- ---- -- SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 1 RAIN DRAIN ft: 1'I'J TRAPS : 0 LAVATORIES • 4 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 1v SF RAIN DRAINS: 1 CATCH BASINS..: 0 TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 1s', BCKFLW PREVNTR: 1 GREASE TRAPS..: 0 OTHER FIXTURES: 0 MECHANICAL FUEL TYPES — FURN (1:s ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1 GAS FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1 MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES • @ GAS OUTLETS...: 1 ELECTRICAL - - ---- - - -- RESIDENTIAL UNIT— — SERVICE /FEEDER— - -TEMP SRVC /FEEDERS— — BRANCH CIRCUITS— ---- MISCELLANEOUS— — ADD'L INSPECTIONS-- 1m SF OR LESS: 1 0 - 200 amp..: ,@ 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 6 201 - 4Y - amp..: 0 201 - 400 amp..: 0. 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR : 0 LIMITED ENERGY.: 0 401 - 6@@ amp..: 0 401 - 600 amp..:. 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MRNF HM /SVC /FDR: 0 601 - lm amp.: 0 601 +amps -1'»i v: 0 MINOR LABEL -10: 0 1000+ amp /volt.: 0 -- PLAN REVIEW SECTION — Reconnect only.: 0 )=4 RES UNITS..: . SVC /FDR) =225 A.: ) . V NOMINAL: CLS AREA /SPC 0CC: - -- ELECTRICAL - RESTRICTED ENERGY -- A. SF RESIDENTIAL B. COMMERCIAL --- - -- AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: 0TH: :: X BOILER HVAC LANDSCAPE /IRRI6: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICR OTHR: .. HVAC • DATA /TELE bi,. NURSE CALLS TOTAL # SYSTEMS: 0 Owner: ----- ---- -- Contractor: — - - -- TOTAL FEES:$ 5094.55 LUTTRELL ENT INC / TANNER LUTTRELL ENTERPRISES INC This permit is subject to the regulations contained in the 224 NW SUNDOWN WAY 224 NW SUNDOWN WAY Tigard Municipal Code, State of Ore. Specialty Codes and all PORTLAND OR 97229 PORTLAND OR 97229 other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is Phone #: 297 -5231 Phone #: 297 -5231 not started within 1: days of issuance, or if the work is Reg #..: 000994 suspended for more than 180 days. ATTENTION: Oregon law — ----- requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 -001 -0010 through OAR 952- 001 -0080. You may obtain copies of these rules or direct questions to SIC by calling (503)246 -1987. - --- - --- -- ---- REQUIRED INSPECTIONS — - - - -____ Erosion Control Post /Beam Meehan Electrical Servi Fireplace Insp Rain drain Insp Mechanical Final Grading Inspecti Crawl Drain Electrical Rough Gas Line Insp Water Line Insp Plumb Final Footing Insp PLM /Underfloor Framing Insp Gas Fireplace Water Service In Building Final Foundation Insp Mechanical Insp Shear Wall Insp Insulation Insp Rppr /Sdwlk Insp Post /Beam Struct Plumb Top Outw Voltage Gyp Board Insp Electrical Final Issued By: Permittee Signature: ,�, _......:�-1/ ,,%ll -��/ + + + + + + + + + + + +_._ ++ i- +++++++++++++++++++++++ + + + + + + + + + +/+ + + + + + + + + + + + + + + + ++ Call 639 -4175 by 6:''0 p.m. for an inspection needed th. next business day ,...._ „R . Plan Check # . CITY OF TIGARD , Residential Building Permit Application Recd By -. r 13125 SW HALL BLVD. New Construction Additions or Alterations Date Recd 0 /�s'I�• TIGARD, OR 97223 Single Family Detached or Attached (Duplex) Date to P.E. • 4.. �zs V 503 -639 -4171 , _ n 0 Date to DST - 7'L -3' �f 7 C 7" F 503- 684 -7297 ' ' ' i �� Permit # // 5i 9 - ?- 639 Print or Type Called q''z-1-i7 RAJ Incomplete or illegible applications will not be accepted Name of Project I / i Yteiv Name ^ i/t Jo b M //v • /`-1 /� /4L-4 ",Z3 S Mai in g Addr ess K r ` S ite Address A . Address /29, 62 ca. k mefiiEa 2/l/. / City /State Zip p Phone C� / Name POrc17.i rJ O t(( I himezi —t. Ex/T, Lire /Y;tJ/t/:1t_ Name Owner Mailing Address a�tef N, v J vNl) 714/A) 4.l Engineer Mailing Address Cit Late Gil. Zip Phone O / _s . -=ac . City/State Zip Phone Name General ,L1177-RLGG sA/7 mi - • • Describe work NeWI Addition 0 Alteration 0 Repair 0 Contractor Mailing Address to be done: it Ai • J, %ru n/ A i Additional Description of Work: C• "State Zip Phone u2tc 4sIz) OA 9202-9 m 7- A,R1 Oregon Const. Cbnt. Board Licit' Exp, Date Attach Copy of 9 9 a ' s �.717! - �:� -,- �� Current COT Business Tax or Metro # Exp. a PR OJECT . f� ‘"-:----k3'` Licenses VALUATION $ =� op -. Name NEW CONSTRUCTION ONLY: Mechanical kel_Vv, 1 e lr 1-1-e-oLLfili-13 Sq. Ft. House: Sq. Ft. Garage Sub- Mailing Address 0280 c P,c /E lo V y Contractor 37 I , S , P - ok a Corner Lot YES NO Flag Lot YES NO City/State _Zip Phone (check one) (check one) i nki /,a. co 7a3 $92,9- s 524 Restricted Audio /Stereo 1 Burglar Oregon Const. Cont. Board Lic.# p. a f Attach Copy of 0 ( :, -, 6 , 1 L. r Energy System Alarm Current COT Business T x or,�nn�et o # Exp. Date Instal Garage Door HVAC Licenses / 6 " G G Opener Systems Name (check all that Other: Plumbing W \ J._L -V I ,u_vu , 0, apply) Sub Mailing Address Will the electrical subcontractor wire for all YES NO Contractor P (2,�- D9 restricted energy installations? City /State Zip Phone Has the Subdivision Plat recorded? N/A YES NO 60vo4X Or LZ��1 O rego Const. Cont. Board Lic.# Ex p. Date Reissue of MST #: Solar Compliance 2 Attach Copy of X3 0 i I - SCE `-51 (Calculation Attached) Current Plumb' ic. # Exp. Date I hearby acknowledge that I have read this application, that the Licenses - Pg 1 2- ' 9 1 i nformation given is correct, that I am the owner or authorized COT 3e T or Metro # Extirpate .� agent of the owner, and that plans submitted are in compliance ��'�� with Oregon State laws. ot97 - 5? - Name , ignat r of Owner /Agen Date Electrical iv c. ,afc7R)� ,,, - L i' if 7 Sub Mailing Address CEO 2s' P -r son Name // f. ir •n= # Contractor g7 �d �. W k �-- ' ` ` , 1 i ``- City/State Zip Pho FOR O FFICE USE ONL __ 1" 6A,o a �, -�� Plat 76_6•_, l cis/ Ut�) a s tr//�fj– fSZft� Ore o Const. Cont. Board Lic.# Exp. D Attach Copy of ( far" .g f I � (• Setbacks/ Zone: ,- /74\ L £i E 0/ Solar: ✓�' Current Electrical tic. Ex ; te /, - C^ / (��6 Licenses 7y — T('7 / Engineering A royal` Planriing Approval: TIF: -- COT Busines7 Tax or Metro # Exp pate 4 ti r iz APP.DOC (DST) 4/97 LSF ( T) L ' . .1 Permit # Acct. Descritpion COT WACO Amount Amt. Pd. Bal. Due 9 --' MST. Permit (BUILD) (UBUILD) 6.88 ° ' GA " , P lumb. Perm (PLUMB) (UPLUMB) 2 ZS, ' 2.25, c r . Mech. Permit (MECH) (UMECH) 4.S 45, ELC /ELR Permit (ELPRMT) (UELPMT) 100. ' 300) � — StateTax (TAX) (UTAX) . 62. 62, ` BLDG: 34 PLUMB: ! /, 2..) MECH: Z , L i „/ ELC /ELR: /S, 0 V Plan Check Z MST: (BUPPLN) (UBUPLN) 4�' 'A' g )v ./----- )q7, Plumb: (PLUMB) (UPLUMB) Mech: (MECPLN) (UMEPLN) //. Z' ' /1, - - 4 CDC Review (BUILD) (CDCBLD) (UCDC) c O 09th , (.0 ' ca, CDC Review (PLN) (CDCPLN) N/A 1'r - j/ L' ..56 Sewer Connon (SWUSA) (USWUSA) 4 Of " A.2®0, C ie,- Reimbur. District ( ) ( ) U Sewer Inspection (SWINSP) (USWINS) ` '� . 3. • w,/ Parks Dev Charge (PKSDC) N/A /e45 at W. • ' . ' . /aSO Residential TIF (TIF -R) (UTIF -R) / • • ral), ", Mass Transit TIF (TIF -MT) (UTIF -M) /3u i)U, Water Quality (WQUAL) (UWQUAL) Water Quantity (WQUANT) (UWQANT) f,11, W c; ,D, Erosion Control Prmt (ERPRMT) (UERPMT) g 8' '-`' • Erosion Planck/USA (ERPLN) (UERPLN) a k; r ` r . ?.• 4.0 Erosion Planck/COT (EROSN) (UEROSN) 4" b �` f' 4,0 Fire Life Safety (FLS) (UFLS) �j 0 • �R TOTALS: • °-----r-- U I:SFAPP.DOC (DST) 4/97 V i / CITY OF TIGARD OREGON INTENT TO HAUL EXCAVATION 1, ( /A-f2( L}rf7r€GL_(print name), hereby certify that all excavation terial on the subject property will be removed from the site and not be placed as fill, except for that amount necessary to back -fill the foundation ONLY. I understand that failure to remove the excavation material will result in the requirement to remove the material or obtain a grading permit by submitting grading plans prepared by a licensed engineer accompanied by a geo- technical report regarding the placement of the excavation material as fill. ( Z/ -eie14-t-P---- - • 1 ' 7 7 *nature Date c Job Address: 7 5 �s k( i- Subdivision: W7 /, 7 S Lot: / 13125 SINabi 1cr4f,,6TTard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 PERMIT NO 77- o 3 ?o EROSION CONTROL INSPECTION REPORT DATE Y - i 3 - Y y INSPECTOR � OWNER/PERMITEE A - h - er v: s , 1, c • SUBDIVISION f ) r • 1/&41_,,,c . LOT SITE ADDRESS l 2g6� Sw X ;c&r , /d v Y i • APPROVED FINAL INSPECTION it • THIS SITE MEETS THE POST - CONSTRUCTION EROSI. �Y.. R CONTROL STANDARDS SET FORTH IN U.S.A. ` RESOLUTION AND ORDER. Ikk NOTE: IF POST - CONSTRUCTION EROSION CONTROL MEASURES ARE STILL BEING EMPLOYED ON THIS SITE TO MEET CRITERIA FOR AN APPROVED FINAL INSPECTION, THE MEASURE(S) MUST REMAIN IN PLACE UNTIL LANDSCAPING IS COMPLETE OR PERMANENT GROUND COVER IS ESTABLISHED. A COPY OF THE FINAL EROSION CONTROL INSPECTION REPORT MUST BE FORWARDED TO THE NEW OWNER, AT WHICH TIME NEW OWNER ASSUMES THE RESPONSIBILITY FOR MAINTENANCE, REPAIR AND REMOVAL. OTHER THANK YOU FOR YOUR COOPERATION! DATE i-/--/3 - 5 7 TIME 3:40 INSPECTOR PHONE a y , / -8 • 5/7/99 Activities for Case #: MST97 -00390 9:15:47 AM Assigned Hold Updated ' Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA005 Application received 9/16/97 GEO PASS JD 9/22/97 MSTA008 Permit Created 9/22/97 JSD PASS JD 9/22/97 MSTA010 Check for prcl. restrict. 9/22/97 JSD PASS JD 9/22/97 MSTA012 Plans routed to Plans Examiner 9/22/97 JSD PASS JD 9/22/97 MSTA026 Plans approved by Pln Examiner 9/23/97 RT PASS BT2 9/23/97 MSTA030 Reviewed plans routed to DSTS 9/23/97 RT PASS BT2 9/23/97 MSTA032 DST Post - Review Completed 9/29/97 B DONE BON 9/29/97 MSTA700 Erosion Control Insp 844 -8444 4/13/99 USA APP JT 4/19/99 entered by Jeanne Temple, copy to file MSTA703 Grading Inspection 2/2/98 PI PASS J *H 2/2/98 22% GRADE going to haul off OK per Paul's inspection of 020298 MSTA705 Footing Insp 10/23/97 KS PASS J *H 10/29/97 Approved as noted: 1. Need to retain adjacent property at right side of garage. 2. Corners of structure have been "surveyed." MSTA706 Foundation Insp 10/30/97 KS PASS J *H 10/31/97 Approved as noted: 1. Install anchor bots at size and spacing as shown. 2. If any isolated piers are located at upper level of cut excavate to lower level of pour expanded pier to lower level. 3. Provide three foundation vents at garage stem wall. 4. Install hold -downs as shown. MSTA710 Post/Beam Structural 11/17/97 - KS PASS J *H 11/17/97 1. Lower level floor system . (partial suspended garage floor not included). 2. No under floor heat ducts (main floor)? MSTA717 PLM /Underfloor 11/14/97 MS PASS MRS 11/14/97 MSTA720 Mechanical Insp 1/5/98 GS FAIL GES 1/5/98 vent.fans not connected; min 30" working clearance at furn MSTA722 Plumb Top Out 1/5/98 GS PASS GES 1/5/98 . MSTA723 Electrical Service . . 1/9/98 BRP PASS J *H 1/11/98 Dryer outlet ? 4 -wire 30 amp . required. • MSTA724 Electrical Rough In 1/9/98 BRP PASS J *H 1/11/98 Box setback excessive some places, both switches and recpt. Dryer outlet ? 4 -wire 30 amp required. Low voltage approved. . Page 1 of 5 5/7/99 Activities for Case #: MST97 -00390 9:15:47 AM • Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA725 Framing Insp 1/22/98 KS FAIL J *H 1/25/98 1. Strap each side of plates to glulam at garage. 2. Nail double hips at garage. 3. Nail double microlam hips. 4. Strap each side of plates to header at patio door. 5. Add vents at birdblocks at patio. 6. Strap header to plates at nook, also toe wall together. 7. Strap plates to header at living room. Also provide full bearing double ceiling joist at living room. 8. Add pier at post supporting floor • joist adjacent furnace at crawl. 9. Bedroom windows at lower level do not meet egress requirements. 10. Add pt 6x6 post supporting garage floor and foundation vent. 11. Provide king studs at girder supproting garage floor each side. 12. Provide bracing at garage floor as shown. 13. Fireblock suspended garage floor line. 14. Provide attic access with curb. MSTA726 Shear Wall Insp 1/20/98 GL FAIL J *H 1/21/98 1. Tighten up nailing on left side lower 'C' wall to 4- inches OC edges. 2. Install A35's or LS50's at shearwalls and floor • joists per note #6 on shearwall schedule. Fireplace not approved. MSTA728 Low Voltage 1/9/98 BRP PASS J *H 1/11/98 TV, telephone, garage door opener, security system, door bell approved. • MSTA730 Fireplace Insp JD 9/22/97 MSTA735 Gas Line Insp 1/5/98 GS FAIL GES 1/5/98 no press MSTA736 Gas Fireplace 1/20/98 GS FAIL J *H 1/21/98 Header framing is to be 41.25 - inches from floor to bottom of headed with nailing flange nailed to same. MSTA740 Insulation Insp 2/2/98 KS FAIL J *H 2/2/98 see framing MSTA745 Gyp Board Insp 2/13/98 KS FAIL J *H 2/13/98 1. Install water -proof gypsum at stall shower. 2. Shear nailing not applicable at gypsum. MSTA755 Rain drain Insp 11/3/97 GS PASS J *H 11/10/97 Rain drains around house approved. MSTA760 Water Line Insp 7/2/98 MS PASS MRS 7/2/98 Page 2 of 5 5 /7 /99 Activities for Case #: MST97 -00390 9:15:47 AM - Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA761 Water Service lnsp JD 9/22/97 MSTA765 Appr /Sdwlk Insp 7/2/98 MH FAIL J *H 7/2/98 Remove & replace driveway . approach wing. MSTA795 Mechanical Final 6/10/98 KS FAIL J *H 6/11/98 Furnace not functional. Kitchen range not functional. Fireplace not functional. MSTA797 Plumb Final 6/10/98 MS FAIL J *H 6/11/98 No hot water. MSTA799 Building Final 3/29/99 KS FAIL AKJ 3/31/99 1) Structure locked, combo not given MSTA080 (F) Ready to issue 9/29/97 B MEMO BON 9/29/97 Needs supervising elec. license and "intent to haul" form signed. MSTA092 (F) Issue combination permit 9/30/97 JSD PASS JD 9/30/97 • MSTA095 Issue plumbing signature form 10/17/97 SW RECD S *W 10/23/97 MSTA097 Issue electric signature form 10/10/97 SW RECD S *W 10/13/97 MSTA705 Footing Insp 10/21/97 KS FAIL J *H 10/29/97 Need to locate property corners and set lines. Incomplete at this time. MSTA705 Footing Insp 10/24/97 RC PASS J *H 11/6/97 Approved by KS previously. MSTA755 Rain drain Insp 11/1/97 MS PASS J *H 11/10/97 Rain drain to storm sewer okay. MSTA713 Crawl Drain 11/1/97 MS .PASS J *H 11/10/97 Crawl drain installed. MSTA720 Mechanical Insp 1/11/98 1/27/98 RC FAIL J *H 1/27/98 As per manufacturer's instructions: Page 5, a sediment trap shall be installed downstream of shutoff valve (as per code) missed on 1st inspection. MSTA720 Mechanical lnsp 1/8/98 KS PART J *H 1/15/98 Approved as noted: 1. Corrections made per GS inspection notes. 2. Gas piping PT test = 30 psi 3. This inspection does not include fireplace. Provide installation manual. 4. combustion air , taken from exterior at fireplace. Do not restrict diameter of combustion air duct at eave . duct need to be secured at eave and sealed. CALL FOR REINSPECTION ITEM #3 ABOVE. MSTA720 Mechanical Insp 1/14/98 KS FAIL J *H 1/15/98 MSTA711 Post/Beam Mechanical 1/21/98 6/10/98 KS FAIL J *H 6/11/98 Remove insulatioin in contact with b -vent under floor. Page 3 of 5 5/7/99 Activities for Case #: MST97 -00390 9:15:47 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes • MSTA720 Mechanical Insp 1/20/98 GL FAIL J *H 1/21/98 1. See page3 of manual for proper installation of header and flange on top of fireplace (figure #6). MSTA726 Shear Wall Insp 1/21/98 KS FAIL J *H 1/21/98 1. Corrections not done per GL notes. 2. Provide clearances per installation manual or at top (standoff) also flange at top of fireplace. MSTA780 ` <REINSPECTION» 1/27/98 B PAID DST 1/27/98 Paid $15.00 for reinspect. Receipt #98- 302830 Bon MSTA725 Framing Insp 1/27/98 RC FAIL J *H 1/27/98 Reinspection fee assessed per earlier report by GS 1. Garage . • door is not braced as per Engineering Plan #12. 2. Strap glulam to plates in garage #1. 3. Provide full bearing for dbl. joist in living room #7. 4. Ridge boards must equal depth of rafters. Missed at 1st inspection as per GS MSTA726 Shear Wall Insp 1/27/98 RC PASS J *H 1/27/98 MSTA780 «REINSPECTION» 1/27/98 RC PAID J *H 1/27/98 framing corrections not performed $15.00 assessed MSTA720 Mechanical Insp 1/28/98 KS PASS J *H 1/29/98 MSTA725 Framing Insp 1/29/98 KS FAIL J *H 1/29/98 1. Provide 3/4 -inch machine bolt at mid -point at angle bracing at suspended garage floor system as shown. Also max; spacing of angle bracing is four ft on center. OK to insulate - call for reinspection frame /insulation. MSTA725 Framing Insp 2/2/98 2/2/98 KS FAIL J *H 2/2/98 1. Install 3/4 -inch bolts, machine at mid -point at suspended garage floor bracing and tighten bolts at upper end • of brace. MSTA740 Insulation Insp 2/2/98 2/6/98 KS PASS J *H 2/6/98 MSTA725 Framing Insp 2/6/98 2/6/98 KS PASS J *H 2/6/98 MSTA707 Slab Insp 3/3/98 KS PASS J *H 3/3/98 1. Extend vapor barrier to top of slab. 2. Install reinforcing at front of slab as shown. 3. Elevate wire mesh. MSTA770 Misc. Inspection 4/1/98 WA PASS J *H 4/2/98 Shower pan MSTA790 Electrical Final 6/24/98 CD FAIL CD 6/24/98 house locked, wrong key in lock box. combo (hba) Page 4 of 5 5/7/99 Activities for Case #: MST97 -00390 9:15:47 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA790 Electrical Final 6/25/98. CD PASS CD 6/25/98 note: security system is rough wired only MSTA728 Low Voltage 6/25/98 CD NOTE J *H 6/26/98 Note: Security system roughin wiring only. . • MSTA797 Plumb Final 7/2/98 MS FAIL MRS 7/2/98 rd require 1'of coverage gas hot water heater not strapped • diverter on tub leaking MSTA795 Mechanical Final 9/30/98 RB FAIL RB 10/1/98 Post Address Protect gas line at exterior; meter & rear deck. Remove debris from return air plenum. Seismic restraint required for hot -water heater. MSTA795 Mechanical Final 3/29/99 KS FAIL AKJ 3/29/99 Structure locked, no combo given MSTA799 Building Final 4/1/99 KS FAIL AKJ 4/1/99 1) Need plumbing finaled 2) Need final erosion control app 3) Combo unit given for lock box didn't work MSTA795 Mechanical Final 4/1/99 KS FAIL AKJ 4/1/99 See bldg final notes MSTA797 Plumb Final 4/1/99 TLP FAIL AKJ 4/1/99 Lock box combo wrong MSTA797 Plumb Final 4/8/99 4/8/99 4/8/99 TLP. FAIL No Hold AKJ 4/8/99 No access MSTA799 Building Final 4/11/99 4/11/99 4/8/99 KS FAIL No Hold AKJ 4/11/99 Structure locked. Called phone # given left mess on vm. Third attempt to gain access, no further inspections until . reinspect fee is paid. MSTA795 Mechanical Final 4/11/99 4/11/99 4/8/99 KS FAIL No Hold AKJ 4/11/99 See bldg final notes MSTA799 Building Final 4/11/99 4/11/99 4/9/99 KS FAIL No Hold AKJ 4/11/99 1) Fireplace not functional also provide installation manual • 2) Provide insulation cert 3) Support flex gas piping at range cabinet . 4) Recover vapor barrier as needed 5) Remove wood and debris at crawl 6) Clear crawl drain 7) Support heat ducts at crawl 8) Need final erosion control app MSTA795 Mechanical Final 4/11/99 4/11/99 4/9/99 KS FAIL No Hold AKJ 4/11/99 See bldg final notes MSTA797 Plumb Final 4/11/99 4/11/99 4/9/99 TLP PASS No Hold AKJ 4/11/99 MSTA799 Building Final 4/15/99 4/15/99 4/15/99 KS PASS No Hold AKJ 4/15/99 Need final erosion control approved MSTA795 Mechanical Final ' 4/15/99 4/15/99 4/15/99 KS PASS No Hold AKJ 4/15/99 MSTA960 (F) Issue Cert. of Occupancy 5/7/99 JMT DONE No Hold JT 5/7/99 Page 5 of 5 ALAN MASCORD DESIGN ASSOC., INC. 1305 N.W. 18TH AVENUE PORTLAND, OREGON 97209 (503) 225 -9161 SOLAR CALCULATIONS FOR ;;WARREN LUTTRELL ii LOT 18 ;; MOUNTAIN HIGHLANDS NO. 2 ;;CITY OF TIGARD GIVEN DESIGN VALUES ;N /S LOT DIMENSION 78 ;;AVERAGE FRONT P.L. GRADE ELEV 100 ;;AVERAGE REAR P.L. GRADE ELEV 3N ;:FINISH FLOOR ELEVATION 404 ;;HEIGHT OF RIDGE ABOVE FF 25 :;HEIGHT OF EAVE ABOVE FF 0 ;;ROOF RISE PER 12 RUN 10 ;;DOES RIDGE RUN N/S Y ;;SETBACK DISTANCE FOR SHADE POINT 26.5 CALCULATED 'VALUES ADJUSTED N/S LOT DIMENSION 78 RIDGE ELEVATION 429 EAVE ELEVATION 404 ADDITION TO S.P.H. FOR N/S RIDGE 3 ADDITION TO S.P.H. FOR LOT SLOPE 0 * ALLOWED SHADE POINT ELEVATION 432 .. ACTUAL SHADE POINT ELEVATIO 429 ® BUILDING COMPLIES WITH SOLAR CODE * BASED ON FORMULA: H = (((2 * D) - N + 150) / 5) + ADJUSTMENTS WHERE H = MAX. ALLOWED HGT. OF SHADE POINT D = DISTANCE BETWEEN SHADE POINT & NORTH LOT LINE N = NORTH SOUTH LOT DIMENSION (90' MAX.) CITY OF TIGARD BUILDING INSPECTION DIVISION MST q7-0 24 Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Datte -IS ,91 AM PM BLD Location I Z- o ✓ � � (-`J • Suite MEC Contact Person 0 Ph z-q 43) PLM Contractor Ph SWR „ Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation i1 - f� - /�. FPS Ftg Drain t"I VV j \ SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Chi AlL=7415✓7 C.:7- 3/o.v 612"v7', 4– mac° Prebv' ; y� Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: , PAS PART FAIL PLUMBING: Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final 11 1=11 L.. FAIL Post & Beam Rough In Gas Line Smoke Dampers ' PART FAIL ELECTRICAL:, Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect- no access ADA Approach /Sidewalk Other Date /S — � Inspector , Ext Final PASS PART FAIL DO NOT.REMOVE this inspection record from the job site.