Permit CITY OF TIGARD
DEVELOPMENT SERVICES
MASTER PERMIT ..
� . .
49,40 DEVELOPMENT #..... < .: MaT97- 0123
- __.. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 04/24/97
PARCEL: 25104DD -01700
SITE ADDRESS... :12945 SW RIDGEFIELD LN
SUBDIfV I'S I ON....: MOUNTA I N HIGHLANDS #2 ZONING: R -4. 5
BLOCK.......... LOT......... .... :014 JURISDICTION: TIG
Remarks: Path 1
--------- — ------ --- --- --- -- BUILDING -----------------------------
REISSUE: STORIES • 2 FLOOR AREAS--- - - ---- BASEMENT...: 1156 sf REQUIRED SETBACKS - - -- REQUIRED --- --
CLASS OF WORK.:NEW HEIGHT • 25 FIRST • 1606 sf GARAGE.....: 892 sf LEFT • 16 SMOKE DETECTRS: Y
TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 1592 sf FRONT • 20 PARKING SPACES: 1
TYPE OF CONST.:SN DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 5
OCCUPANCY GRP. :R3 BORN: 3 BATH: 3 TOTAL -: 3198 sf VALUE..$: 307054 REAR • 47
---------- __— -- _____________ PLUMBING _________________________ ________________ _______
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 1 RAIN DRAIN ft: 0 TRAPS • 0
LAVATORIES • 5 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 1 CATCH BASINS..: 0
TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
- --------- --- - -- MECHANICAL - - --
FUEL TYPES----------- FURN (100K :.: 0* BOIL /CMP ( 3HP: 0 VENT FANS • 5 CLOTHES DRYERS: 1
GAS FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1
MAX INN.: 0 BTU' FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES....: 0 GAS OUTLETS...: 1
—__ —_— — __.___ - ELECTRICAL - - ---
-- RESIDENTIAL UNIT -- - -- SERVICE /FEEDER -- - -TEMP SRVC /FEEDERS— -- BRANCH CIRCUITS -- - - -- MISCELLANEOUS- --- — ADD'L INSPECTIONS--
1000 SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500SF.: 9 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0
LIMITED ENERGY.: 0 401 - amp..: 0 401 - 600 amp..: 0 EA ADDL.BR,CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0
MANF HM /SVC /FDR: 0 601 - 1'AO amp.: 0 601 +amps -1000 v: 0 MINOR LABEL -10: 0
1000+ amp /volt.: 0 --- ----------- -- - - -- PLAN REVIEW SECTION ------ ------- ---------- Reconnect only.: 0 ) =4 RES UNITS..: SVC/FDR)=225 A.: ) 600 V NOMINAL: CLS AREA /SPC BCC:
------ ---- -- --------------- --- - -- ELECTRICAL - RESTRICTED ENERGY - - - — _ �— __ -� - --
A. SF RESIDENTIAL- -- --- ---- - - - - -- B. COMMERCIAL - - - - -- ---- - ----- ------------ -
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: OTH: :: X BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR:
HVAC DATA/TELE COMM.: NURSE CALLS TOTAL it SYSTEMS: 0
Owner: - - -Contractor: ------------- -- ---- TOTAL FEES:$ 5557.30
YOO HI CHIN ' OWNER
171 SW PARK AVE
PORTLAND OR 97201
Phone #: 525 -8440 Phone #:
Reg
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other
applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180
days of issuance, or if work is suspended for more than 180 days.
-------- - - ---- ----------------- - - - - -- REQUIRED INSPECTIONS --------------- -
Erosion Contol Post /Beam Meehan Electrical Servi Gas Line Insp Water Service In Building Final
Grading Inspecti Crawl Drain Electrical Rough Gas Fireplace Appr /Sdwlk Insp
Footing Insp PLM /Underfloor Framing Insp Insulation Insp Electrical Final
Foundation Insp Mechanical Insp Shear Wall Insp Gyp Board Insp Mechanical Final
Post /Beam Struct . ' Plumb Top Out Low Voltage Rain drain Insp Plumb Final
Permittee Signature: Issued By :',', '��f . r/_1�
Call for inspection — 639 -4175 4,
Plan Ch
.-' OF TIGARD Residential Building Permit Application Recd By
A5 SW HALL BLVD. New Construction Additions or Alterations Date Recd 9 -[0 - 97
. =; RD, OR 97223 Single Family Detached or Attached (Duplex) Date to P.E. y-11-q
,3- 639 -417' - Date to DST - 2 I' _ 7
13 -684 -7297 Permit # ?`bl &W07 - 011c'
.f .
Print or Type .,,,.. 1 - 7
Incomplete or illegible applications will not be accepted rtitufv4A s °mss q -174 7
Name of Project Name
Job G(4IN ` S R ESI Dom!tT I� S -vu/ T
' Architect Mailing Address
Address Site Address (� /4‘,44 Jp iz'j CS t '042/746 1 't G" au) �-t�cef Ac L) City/State tip Ph ne
Name
Ye it I G14 i"0 As „..f.14�l yi eo, 7 2e'7z.
Owner Mailing Address Name
/ /1 SW fI 6 . �r1 P cl ` j
Engineer Mailing Address ■
City /State f ' Zip Phone , g -6 6 S / / '' 0 SI-
D� a
_ I J I
O o City /State Zip 'Phone
Name ,Te , /I , k., !►', ! ' , fs .. : .
General ��, 'l It l,/ee Describe work Newyk A d dition 0 Alteration 0 Repair 0
ontractor Ma h Add to be done:
�(' M,� ®D � C.pKPjtjLL �I 22 -'x - Additional Description of Work:
I v� l City /State Zi Phone
O on Const. Cont. Board Li Exp. bate r . .each Copy of g 04- I I .' rj l p
$ � r�
Current CO Business tax or Metro # Exp. Date PROJECT ll
Licenses ( 0 :16'� _ 7 -0I -9'7 VALUATION $ 2, 3 0
Name .,,,,�',
aechanical -c --�� � P :1. r t4 NEW CONSTRUCTION O '
•
Sub- Mailing Address Sq. Ft. House: Sq. Ft. Garage
Contractor r Corner Lot YES NO Flag Lot YES NQ
City/State Zip Phone (check one) (check one) , I
Oregon Const. Cont. Board Luc.# : Exp. Date Restricted Audio /Stereo Burglar
Attach Copy of i Energy System I Alarm
Current COT Business Tax or Metro # I Exp. Date Installation Y Garage Door HVAC
Licenses
I Opener Systems _
Name - • . (check all that Other. .r
0lumbing 1 /ItA PIULAM,A00Agt. apply)
Sub Mailing Address ',..1 l Will the electrical subcontractor wire for all YES NO
contractor c b Z- 6u, I`t0 restricted energy installations? I t
ty/S a te, Z Phone „ ' Has the Subdivision Plat recorded? N/A YES NO
, G�1w� God �"
Oregon Const. Cont. Board Lic.* Exp. Date Reissue of MST #: Solar Compliance
.attach Copy of ( r re b I 7 - 4 ' ? (Calculation Attached)
Current Plumping Lc.* Q Exp. Date � I hearby acknowledge that I have read this application, that the
Licenses - OIP I V 1,-51 " °l information given is correct, that I am the owner or authorized
COT ausine s Tax o. letro . Exp. Date
�7/ � �� agent of the owner, and that plans submitted are in compliance
11 with Oregon State laws.
' Name '
^, (� � Si azure f 0 ner /Agent I Dat
= ')�ectrical Iv 1. �i t 447 ,i
M alin Address
Sub Contact erson Name Phone ft
.:1trac -or 71; 56 'W CA L� e l b-°i 1 111
c, to Zip Phone FOR OFFICE USE ONLY:
l l lb i ° I1 a Z3 15�I�t Plat x: ! a rrL*:
Oregon Const. Cont. Board Lic.a Exp. Date M t l -% I �/t�6 I 1 '4 DD- flDO
t I (I 6,' Setti ck :: Kp Zone: q r:
S Sola, / •
` ' t n 'u) Fa I Pl n�ng Approval: TIF:
CCT 3us;ness Tax r KAetro # Exp. Date /�
��0 Z I I� (�' l i:\sfbpp.doc (dst) 1/97
14 I — Ib -I -°f 4 i 14-i 1-11
Permit Account Description Amount Amt. Pd, Bal. Due
m.0.97•olz3 MST. Permit (BUILD) 9s3. 953, t '`
Plumb. Permit (PLUMB) 2,25. ®'— 225.
Mech. Permit (MECH) 4 q9,
ELC /ELR Permit (ELPRMT) 375, eo _ 375,
State Tax (TAX) 8o• °-‘ 80.os
Bldg: 4.7.5 ./
Plumb: 71.2s 7
Mech: 2.4°
•
ELC /ELR: /9, 75- t
Plan Check
MST: (BUPPLN) 61,9, 1 4 ,57:) 369, 22 :
Plumb: (PLMPLN)
Mech: (MECPLN) I Z, " I2, t "
cc b1.-1. LO
CDC Review (LANDUS) 40, `= (`' ?($J 2 O ,---
Sw047 =ui19 Sewer Connection (SWUSA) 22.0.0, % 22110.4
Reimbursement District ( )
Sewer Inspection (SWINSP) 34" 3S `�
Parks Dev Charge (PKSDC) JOSa, Co /OSo. .
Residential TIF (TIF -R) /S 7a. `° /57o. f
Mass Transit TIF (TIF -MT) /Z0, /20 '�
Water Quality (WQUAL) /6'o. ° d !P, c
Water Quantity (WQUANT) /0a ,IY6
Erosion Control Permit ( ERPRMT) //2, ` I/IL• '
Erosion Planck/USA (ERPLAN) ,,, „. �d 36. 1
Erosion Planck/COT (EROSN) 36.1 j .76. �'� `' /
Fire Life Safety (FLS) /'____
TOTALS: - 77V. ° 0 5o. w /7542. 1°--.
iasfaPP.dac (dst ) 1197
Solar Balance Point Standard Worksheet
Address
Box A calculations: North -South dimension for the lot: Box A:
This dimension is determined by finding the midpoint of the North lot line and drawing
an intersecting line perpendicular to that point.
First, determine which property line is the North lot line. The North lot line is the line
with the smailest angle from a line drawn east -west and intersecting the northern most
point of the lot.
* 45 o -..
1 1
N North -South
Dimension for Lot:
•
Measure the distance from the midpoint of the North lot line to the South lot line along
the described line. /li le- feet
jacsrsascui4
c ue
Sox 3 calculations: Shade point height for your residence- Box 3:
1. Determine whether measurements will be based on the peak or eave of your Whiff describes
structure. The orientation of the ridge is also important.
your residence?
la: If the roof line runs North- South, measurements will (drde one)
be based on the peak of the roof. coca
,v
:am sal
wave ( / 13 1 C
1 b: If the roof line runs East -West and the roof pitch is
less :ran 5/12, measurements will be based en the
eave. II
1c: If the roof lire runs East -Nest and the roof pitch is
5/12 cr steeper, measurements will be based on the .. Once C
peak. ...a
Box B. continued Box S:
2.. Measure change in elevation from front property line to_finished floor elevation. If - ,
the lot slopes up from the front lot, line to the foundation, the figure is positive. If -.
'it ft
the lot slopes down from the front lot line to the foundation the figure is negative.
3. Measure distance from finished floor elevation to the affected peak/eave. +.._ %S` �(� ��. ft
. 4. If the roof line runs North - South, deduct three feet. If the roof line runs East - West, '` ft
deduct nothing. .
5. Subtract one foot for each foot of difference in elevation from the front property
line to the rear property line, if the lot slopes up from the front to the rear. If the
lot has no slope or slopes up from the rear to the front, deduct nothing. 2,-0 ft
6. Total figure for box B: r 01. ,.r ft
Box C. Distance to the shade reduction line. Box C:
1. Measure the distance from the North property line to the foundation near the 2S ft
affected peak/eave.
2._ Measure the distance from the foundation to the affected peak or eave. + 1-4 ft
3. Total figure for box C: -rill ft
it is most useful to draw a vertical line to represent the appropriate figure found in box 'A' and a horizontal Gne to represent the
appropriate figure found in box C. The intersection of the vertical and horizontal t detei nines the value found in box D. The value
in box '0' should be compared to the value in box '8'; if the value in bail)" is less than or equal to the value found in box '0', then
the building is in compliance with the solar balance code. If you have any questions, please contact us at 639 -4171, x304 or at the
Community Development Counter.
MAXIMIIM PERMITTED SHADE POINT HEIGHT (In Feet)
Distance to North - south lot dimension fin feed
shade 100+ 95 90 85 80 75 70 65 60 55 50 45 40
reduction fine
from northern
!cc in fin few!
70 4 40 40 41 42 43 44
1
65 3 38 38 39 40 41 42 43
60` 36 36 36 37 38 39 40 41 42
55 14-4---3.4_3.4_35_...3.6_17_18_19_ 40 41
503 32 32 33 34 35 36 37 33 39 40
• 4 3 3 30 30 31 32 33 34 35 36 37 38 39
40 2 23 23 29 30 31 32 33 34 35 36 37 33
33 2 26 26 27 28 29 30 31 32 33 34 35 36
20 24 24 25 26 27 23 29 30 31 32 33 34
25 ' 22 22 23 24 25 25 27 23 29 30 31 32
- 2.0 0 20 20 21 22 23 24 25 26 27 28 29 30
13 18 18 18 19 20 21 2 2 23 24 25 26 27 28 '
10 i;6 16 16 17 13 19 20 21 22 23 24 25 26
5 - 14 14 14 15 16 17 18 19 20 21 22 23 24
Box D. Maximum allowed shade point height: , feet I
h: \sc ar.d,p
Revised 21261n6
Page No. 1 - CASE HISTORY FOR CASE NO.: MST97 -0123
ACCENT RESIDENTIAL HOMES INC
12945 SW RIDGEFIELD LN
11/17/98
Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA005 Application received / / / / 04/10/97 RECD DRA 04/17/97 BON
MSTA008 Permit Created / / / / 04/17/97 PASS B 04/17/97 BON
MSTA010 Check for prcl. restrict. / / / / 04/17/97 PASS B 04/17/97 BON
MSTA012 Plans routed to Plans Examiner / / / / 04/17/97 PASS B 04/17/97 BON
MSTA026 Plans approved by RPE / / / / 04/21/97 PASS RT 04/21/97 BT2
MSTA030 Reviewed plans routed to DSTS / / / / 04/21/97 PASS RT 04/21/97 BT2
MSTA032 DST Post - Review Completed / / / / 04/24/97 PASS B 04/24/97 BON
MSTA050 Hold for / / / / 01/3.0/98 call from Accent Custom Homes, 579 -2064, 01/30/98 JT
they are taking over the job. I called
them back, we need their updated
contractor info, and is Harmony the
Plumber? Asked that they fax info to
DST's.
hold plumbing inspections, have not
received signature form
MSTA080 (F) Ready to issue / / / / 04/24/97 Need contractor and mechanical licensing MEMO B 04/24/97 BON
etc.
MSTA092 (F) Issue combination permit / / / / 04/24/97 PAID JMH 04/24/97 J *H
MSTA095 Issue plumbing signature form / -/ / / 04/24/97 PAID JMH 04/24/97 J *H
MSTA097 Issue electric signature form / / / / 02/09/98 RECD JMT 02/09/98 JT
MSTA097 Issue electric signature form / / / / 02/06/98 Change in contractor. PASS SW 02/06/98 S *W
MSTA202 Hold Release to Issued Status / / / / 02/10/98 Looks like info recd 020298. PASS JMH 02/10/98 J *H
MSTA700 Erosion Contol / / / / / / 04/17/97 'BON
MSTA703 Grading Inspection / / / / 02/10/98 Grading okay. PASS PI 02/11/98 J *H
MSTA705 Footing Insp / / / / 05/21/97 erosion control approved on site and ok. FAIL DD 05/23/97 ROC
not ready for inspection.
•
MSTA705 Footing Insp / / / / 05/23/97 Remove debris from pour area PASS RC 05/27/97 J *H
MSTA706 Foundation Insp / / / / 06/10/97 PASS RC 06/15/97 J *H
MSTA707 Slab Insp / / / / 05/06/98 Garage slab inspection: FAIL WDJ 05/06/98 WDJ
1. Provide access to crawlspace under
garage floor.
2. Provide,copy of approved Post and
Beam inspection for garage area.
Correction notice was issued 7/31/97.
MSTA707 Slab Insp / / / / 05/08/98 Post\Beam corrections are completed. PASS WDJ 05/08/98 WDJ
Page No. 2 CASE HISTORY FOR CASE NO., MST97 -0123
ACCENT RESIDENTIAL HOMES INC
12945 SW RIDGEFIELD LN
11/17/98
Action Description Rep/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
•
MSTA710 Post /Beam Structural / / / / 07/22/97 1. Partial lower level only. This PART KS 07/22/97 J *H
inspection does not include suspsended
garage floor system.
MSTA710 Post /Beam Structural / / / / 07/31/97 1. Provide blocking at suspended floor FAIL KS '08/20/97 J *H
system as shown.
2. Replace (notched joist at brackets).
3. Nail ledger to each stud (center) add
ledger under upper.
4. Provide ventilation.
5. Replace built -up studs supporting
glulam beams at each support. •
- MSTA710 Post /Beam Structural / / / / 05/08/98 Provide a minimum 18x24 access to PASS WDJ 05/08/98 WDJ
underfloor area prior to final.
MSTA711 Post /Beam Mechanical / / / / 04/01/98 See rough -in. FAIL KS 04/02/98 J *H
MSTA713 Crawl Drain / / / / 07/02/97 need to sleeve or dig under footing so PASS MS 11/17/98 JT
water can drain to low points, approved
subject to'above.
MSTA717 PLM /Underfloor / / / / 03/17/98 PASS TN 03/22/98 J *H
MSTA720 Mechanical Insp / / / / 03/06/98 1. Gas line 0 pressure. FAIL RB 03/06/98 J *H
2. Soffit ductwork in garage.
3. Seal return air and blocks in garage
and family room. Seal all side holes
too.
4. Flame spread and insulate fireplace
cavity.
5. Extend dryer vent to within laundry
room.
6. Secure range venting into place.
7. Heat caulk living room venting joint.
8. Flame spread and insulate fireplace
cavity. '
9. Family bath upstairs - exhaust vent
disconnected. Same at master bath.
l0.Enclose firestop duct chase upstairs.
11.Terminate exhaust venting to the
outside at present time, no roof vents.
12. That part of basement metal duct
exposed to unconditioned space must be
insulated R8.
Page No. 3 CASE HISTORY FOR CASE NO.: MST97 -0123
ACCENT RESIDENTIAL HOMES INC
12945 SW RIDGEFIELD LN
11/17/98
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA720 Mechanical Insp / / / / 03/18/98 1. Seal around all penetrations at FAIL KS 03/23/98 J *H
return air cavity (caulk).
2. Replace damaged exhaust duct at tub
bath.
3. Extend exhaust ducts to roof jack and
secure above roof sheathing.
4. Insulation at FS paper not installed
at both fireplaces.
5. Insulate exposed heat ducts at crawl
space to R -8 value.
6. Attach insulation at furnace plenum
house.
7. Support gas piping at living room
fireplace at floor cavity.
8. Add nailers adjacent to furnace for
attachment of gypsum.
•
MSTA720 Mechanical Insp / / / / 04/01/98 Mech rough in & framing: FAIL KS 04/02/98 J *H
1. Complete purlin walls.
2. Strap across plates at glulam (den).
3. Install eave baffles.
4. Pressure not adequate for test.
5. Nailers at mechanical soffits 2 -? OC
6. Insulate heat duct at unconditioned
space.
OKAY TO INSULATE, CALL FOR REINSPECTION
OF MECH /FRAMING. DO NOT REMOVE CARD
UNTIL APPROVED.
MSTA720 Mechanical Insp / / / / 04/08/98 Mechanical & Insulation notes: PASS KS 04/08/98 J *H
1. Install eave baffles.
2. Seal around all penetrations.
3. Cover exposed insulation at lower
level tub.
4. Insulate furnace plenum, ducts at
crawl.
5. Insulate stem walls at lower level.
6. Remove insulation contract at b -vent.
7. Insulate heat ducts at soffits.
8. 304752 gas tag.
•
Page No. 4 CASE HISTORY FOR CASE NO.: MST97 -0123
ACCENT RESIDENTIAL HOMES INC
12945 SW RIDGEFIELD LN
11/17/98
Action Description Reg/ Schd/ End /, Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA720 Mechanical Insp / / / / 04/07/98 Approved as noted: PASS KS 04/10/98 J *H
1. Install eave baffles.
2. Seal around all penetrations.
3. Cover exposed insulation at lower
level tub.
4. Insulate furnace plenum, ducts at
crawl.
5. Insulate stem walls at lower level.
6. Remove insulation contact at b -vent.
7. Insulate heat ducts at soffits.
8. Gas piping PT test = 30 psi tag
304752.
,MSTA722 Plumb Top Out / / / / 12/24/97 no test FAIL MS. 12/29/97 MRS
MSTA722 Plumb Top Out / / / / 03/06/98 No test on DMV install nail plates on FAIL WA 03/09/98 J *H
3 -inch ABS waste at lower floor. Anchor
hose bib at deck or 1st floor. Anchor
hose bibb in garage.
MSTA722 Plumb Top Out / / / / 03/17/98 PASS TN 03/22/98 J *H
MSTA723 Electrical Service / / / / 02/17/98 PASS BRP 02/24/98 J *H
MSTA724 Electrical Rough In / / / / 02/17/98 box mounting good PASS BRP 02/24/98 J *H
•
Page No. 5 CASE HISTORY FOR CASE NO.: MST97 -0123
ACCENT RESIDENTIAL HOMES INC
12945 SW RIDGEFIELD LN
11/17/98
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA725 Framing Insp / / / / 03/26/98 1. Nail joist hangers at suspended FAIL KS 04/02/98 J *H
garage floor.
2. Lateral brace post supporting garage
floor.
3. Nail ledger supporting garage floor
(add studs under ledger at - each stud
and nail 16d 6 -inch OC.
4.
5. Nail TJI hangers lower level.
6. Provide TJI layout, provide access to
crawl.
7. Fireblock ceiling line at living
room.
8. Fireblock stairs.
9. Support glulam at living room to
grade.
10. Positive connection at built up ? at
living room.
11. Solid block under living room hip.
12. Add purlin wall at foyer and at
others.
13. Support under hips valleys, and
ridge.
14. Provide attic access.
15. Provide eave baffles.
16. Vent each rafter space at living
room.
17. Attic access at garage.
18. Strap plates to glulam at garage.
MSTA725 Framing Insp 04/02/98 / / 04/01/98 See mech rough in. FAIL KS 04/02/98 J *H
MSTA725 Framing Insp 04/10/98 / / 04/07/98 Approved as noted on mechanical PASS KS 04/10/98 J *H
inspection of 040798.
MSTA726 Shear Wall Insp / / / / 12/04/97 Unable to perform inspection - address FAIL RC 12/04/97 J *H
not posted - notice posted.
MSTA726 Shear Wall Insp / / / / 12/05/97 NO APPROVED PLANS AT SITE. FAIL RC 12/09/97 J *H
MSTA726 Shear Wall Insp / / / / 02/10/98 Incomplete at this time. FAIL KS 02/10/98 J *H
Page No. 6 CASE HISTORY FOR CASE NO.: MST97 -0123
ACCENT RESIDENTIAL HOMES INC
12945 SW RIDGEFIELD LN
11/17/98
Action .Description Req/ Schd/ End/ Action Notes Dip By Update Upd
Code Sent Done Done Date By
MSTA726 Shear Wall Insp / / / / 02/13/98 1. MST #37 straps missed at garage. FAIL KS 02/13/98 J *H
2. HPHD hold -downs missed at den.
3. HPHD hold -downs missed at family
•
room.
4. HTT22 missed at rear garage.
5. Interior shear panels not done.
6. Re -nail panels (nails penetrated
outer layer of panel).
MSTA726 Shear Wall Insp / / / / 03/04/98 1. Corrections incomplete, install all FAIL KS 03/19/98 TLP
holdowns as shown. 2. Complete BP panels
and remaining panels where nails have
penetrated outer layer of panel.
MSTA726 Shear Wall Insp / / / / 03/06/98 Not ready. FAIL RB 03/19/98 TLP
Plans missing engineering page. Missed
nailing (marked), drag strut missed,
blocking missed.
Page 8 on plans identifies 2 different
ABP details: one is what you've done,
the other is also required for 2 -3
stories.
MSTA726 Shear Wall Insp 04/02/98 / / 04/01/98 OKay to insulate. PASS KS 04/02/98 J *H
MSTA727 Low Voltage / / / / / / 04/17/97 BON
MSTA735 Gas Line Insp / / / / 04/01/98 FAIL KS 04/02/98 J *H
MSTA735 Gas Line Insp 03/23/98 / / 04/07/98 Gas tag 304752. PASS KS 04/08/98 J *H
MSTA740 Insulation Insp / / / / 04/08/98 1. Plumbing rough not connected at FAIL KS 04/09/98 J *H
utility room.
2. Insulate behind tub at upper level
and fs paper.
3. Provide fs paper at jacuzzi.
4. If water -proof gypsum is applied at
stall shower in lieu of wonder board
remove vapor barrier.
MSTA740 Insulation Insp / / / / 04/07/98 FAIL KS 04/08/98 J *H
MSTA740 Insulation Insp / / / / 04/07/98 See mechanical inspection 040798. FAIL KS 04/10/98 J *H
MSTA740 Insulation Insp / / / / 04/13/98 PASS KS 04 /13/98 J *H
MSTA745 Gyp Board Insp / / / / 06/16/98 Cancelled by request (wet hardwood CANC KS 06/17/98 J *H
floors).
Page No. 7 CASE HISTORY FOR CASE NO.: MST97 -0123
ACCENT RESIDENTIAL HOMES INC
12945 SW RIDGEFIELD LN
11/17/98
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
•
MSTA755 Rain drain Insp / / / / 07/02/97 1. Easement to street for storm sewer. PASS MS 07/06/97 J *H
2. Backwater valve ok.
3. Need to sleeve or dig under footing
so water can drain to low points.
Approved subject to the above.
MSTA755 Rain drain Insp / / / / 07/07/97 needs to run 4" to street PART MS 07/07/97 J *H
MSTA761 Water Service Insp / / / / 03/06/98 PASS WA 03/09/98 J *H
MSTA765 Appr /Sdwlk Insp / / / / 06/09/98 DO NOT POUR: FAIL MH 06/10/98 J *H
1. Driveway exceeds max. allowable width
of 30 -feet. REFORM.
2. Driveway wings to be 3 -feet at face
of curb.
CALL FOR REINSPECTION.
MSTA765 Appr / Sdwlk Insp / / / / 06/10/98 Approved as noted: 1. Maintain 30 -ft. PASS MH 06/11/98 J *H
max. width at back of approach. 2.
Maintain 3 -ft. d/w wings.
MSTA770 Misc. Inspection 06/03/98 / / 05/29/98 Shower liner okay. PASS MS 06/03/98 J *H
MSTA790 Electrical Final / / / / 06/09/98 Not ready for final. FAIL BRP 06/09/98 B *P
MSTA790 Electrical Final / / / / 06/10/98 Corrections approved. PASS BRP 06/11/98 J *H
MSTA795 Mechanical Final / / / / 06/17/98 PASS KS 06/18/98 J *H
MSTA797 Plumb Final 06/03/98 / / 06/09/98 FAIL MS 06/10/98 MRS
MSTA797 Plumb Final / / / / 06/10/98 PASS MS 11/15/98 J *H
•
•
Page No. 8 CASE HISTORY FOR CASE NO.: MST97 -0123
ACCENT RESIDENTIAL HOMES INC
12945 SW RIDGEFIELD LN
11/17/98
Action Description Rep/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA799 Building Final / / / / 06/11/98 Mech & Bldg final: FAIL KS 06/17/98 J *H
1. Need final erosion control approved.
2. Driveway approach and sidewalk not
• poured.
3. Post insulation certificate.
4. Seal voids and mechanical at garage.
5. Support gas piping at water heater
(vertical & horizontal).
6. Kitchen hood not functional.
-7. Fireplace not functional.
8. Guardrail at upper deck not complete.
9. Insulate exposed heat duct at storage
room (upper bedroom and floor cavity).
10. Front stoop not poured.
11. Provide guardrail at fron entrance
and extend to less than thirty inches
upper elevation 1 lower.
12. Connect rain drain front of garage.
13. Stairs not built at lower deck.
14. Rain drains not connected.
15. Provide landing and guardrail at
lower level man door. Also, vapor
barrier at crawl space.
16. Need to locate low point drain also
provide drainage between strip footings
at crawl.
• 17. Remove debris cover vapor barrier as
needed.
18. Slope finish grade away from
structure at sides.
MSTA799 Building Final / / / / 06/17/98 PASS KS 06/18/98 J *H
MSTA960 (F) Issue Cert. of Occupancy / / / / 06/17/98 11/17/98 JT
•