Permit OFTIGARD CITY
,..
„„,, ., DEVELOPMENT SERVICES MASTER PERMIT
�VI PERM I T # • MST96 -04 �2
- 13125 SW Nall Blvd., Tigard, OR 97223 503 639.4171 DATE ISSUED: 10 17 / T9
PARCEL: 2S104DD -01800
SITE ADDRESS...: 12939 SW RIDGEFIELD LN
SUBDIVISION • MOUNTAIN HIGHLANDS #2 ZONING: R -4.5 PD
BLOCK . LOT • 015
Remarks: Path 1
- - -- BUILDING --- - —
REISSUE: STORIES : 2 FLOOR AREAS ---- BASEMENT...: 0 sf REQUIRED SETBACKS— REQUIRED —
CLASS OF WORK.:NEW HEIGHT • 25 FIRST • 1277 sf GARAGE • 876 sf LEFT • 8 SMOKE DETECTRS: Y
TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 1559 sf FRONT • 20 PARKING SPACES: 1
TYPE OF CONST.:5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 30
OCCUPANCY 6RP.:R3 BDRM: 4 BATH: 3 TOTAL------: 2836 sf VALUE..$: 205216 REAR • 49
PL ' ° i:INS - - - - - --
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 1 RAIN DRAIN ft: 0 TRAPS : 0
LAVATORIES • 5 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 1 CATCH BASINS..: 0
TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 1% BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
MECHANICAL --
FUEL TYPES FURN ( 1'AK ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1
/GAS/ / / FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1
MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS : 0 WOODSTOVES : 0 GAS OUTLETS...: 1
ELECTRICAL --
- RESIDENTIAL UNIT— — SERVICE /FEEDER -- —TEMP SRVC /FEEDERS— — BRANCH CIRCUITS— - -- MISCELLANEOUS— — ADD'L INSPECTIONS -
1m SF OR LESS: 1 0 - 200 alp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500SF.: 6 201 - 400 amp..: 0 201 - 400 alp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0
LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0
MANF HM /SVC /FDR: 0 601 - 1-"' amp.: 0 601+amps- 1m v: 0 MINOR LABEL -10: 0
1m + amp /volt.: 0 -- -- PLAN REVIEW SECTION - - --
Reconnect only.: 0 )4 RES UNITS..: SVC /FDR ?=225 A.: > 600 V NOMINAL: CLS AREA /SPC OCC:
- - -- — -- ELECTRICAL - RESTRICTED ENERGY - -- —
A. SF RESIDENTIAL- B. COMMERCIAL -- — -- - --
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: OTH: :: X BOILER HVAC • LANDSCAPE /IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL • OTHR: ..
HVAC DATA /TELE COMM.: NURSE CALLS TOTAL # SYSTEMS: 0
Owner: -------- -------- -- Contractor: — — TOTAL FEES:$ 4821.55
BEAR CONSTRUCTION CO BEAR CONSTRUCTION CO
8076 SW 184TH AVE 8076 SW 184TH AVE
BEAVERTON OR 97w BEAVERTON OR 97007
Phone #: 642 -3512 Phone #: 642 -3512
Reg #..: 17098
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other
applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180
days of issuance, or if work is suspended for more than 180 days.
-- -- — REQUIRED INSPECTIONS ----------------------------------------------- --
Footing Insp PLM /Underfloor Framing Insp 6as Fireplace Water Service In Building Final
Foundation Insp Mechanical Insp Shear Wall Insp Insulation Insp Appr /Sdwlk Insp Erosion Control
Post /Beam Struct Plumb Top Out Low Voltage Gyp Board Insp Electrical Final
Post /Beam Meehan Electrical Servi ireplace Insp Rain drain Insp Mechanical Final
Crawl Drain Electrical Rough Il s Line ! sp Water Line Insp Plu Final
A OVA,' AA Permittee Signature: A" 4� Issued By: I/
Call for inspection — 639 -4175
07 08:37 '8`503 68-1 7297 CITY OF TIGARD , . . Q002/007
Plan Check # -Z[
CITY OF TIGARD Residential Building Permit Application Reed ayI
13125 SW HALL BLVD. New Construction Additions or Alterations Date Recd - -
"1GARD, OR 97223 Single Family Detached or Attached Dale to P.E: J z 42
303) 639 -4171 Date to DST '.2
Print or Type Permit # 5 ' - s 32-
Called i7- 4 - /
Incompletle or illegible applications will not be accepted
Name of Subdivision I1 iHL,d
t of > F . N Job 1 T J .J . �o k 10 4 i --
z-
Address Site Address — Architect !!Aaiun ddress
1A937 Stec *e g t dd. Live SW �PQ
!State Bp Phone
Name 1 # k)
1 Owner Mailing Address I L 610 ICH'
City/State Zip k Phone Engineer .91dress
5 co gilt-44. -�.a me 1 7 S (o tate p Phone
General R um `�' Co - Describe work caw addition 0 alteration 0 repair 0
Contractor
:ling Address
t d Sic] 1651' /�
�TUL to be done:
_ Additional Description of Work:
f 1 !State p hone
Off, • ii, l?on7 p hone 35 i a-
Oregon Const Cant. oard tic# E= Da
Attach opy of 1 70S8� 57 I ( Y7 Project
Current COT ^ OS. /
ine T r tro # Ex a �(
Licenses ' .. to Valuation 3 / gL
NEW CONSTRUCTION ONLY:
Mechanical _ Al , 'Z,J • Sq•Ft_ Hous Sq_FtGarage: , 1 _,
Sub Ma f S T&fYI
g Address NC � 'Y
Contractor ty Stu reik0 Corner Lot Yes No Flag Lot Yes No�
‘ V Ci / zip ���rr on (check one) ) (check one) .
tZ.Q 'Sd)7 Restricted Audio /Stereo Burglar
regon Const Cont. =card Licit Exp. to / /g 7 e System Alarm
Attach Copy of - • - ±A Energy rgY
Current T Bu -mess T_� fZ � Exp. Date Installation ✓ Garage Door HVAC
Licenses / " =- °� - 0 _ __ Opener 1 ,,/ -... Systems
x . e t... ii/ - I (check all that Other.
Plumbing .,S . -r.i(2.. apply)
Sub- Mailing Address Will the electrical subcontractor wire for all Yes I;1¢
q restricted energy installations?
Contractor /C7 , �� � Has the Subdivision Plat recorded? N/A X�.s No.
0 \k I �c'�O Zip �O ' 407!6 '
Oregon Conn Cont. SAaro Lic.s Exp. date Reissue of MST# Solar Compliance t....
Attach Copy oft/ Ef12- 7 ei (Calculation Attached)
Currant • JP umbing tic. # Exp. Data I hereby acknowledge that I have read this application, that the
Licenses I/ 3 * -(/ 5 3Q_97 information given is • - that I am the owner or authorized agent of
COT Business Tax r Metro ` Exp. Date the r, aril • at s submitted are in compliance with Oregon
96 y -7 C. stata : ,
e Sig n j. �'e t ..r.. / 9.(�
Electrical k ra Zic..c_ of _ Con' MairAilMinalli none
Sub- Mailing Address � �� V 3 3
Contra $ _ sc�) V T , W L- FOR OFFICE USE ONLY: _
0\1 +, r ate- n Zip Phone Plat # C MaprTL#: ) C
Ore non o»ont Board Lic.# Ex& . Da q �r " J I `� v - (r'1'`
O
Attach Copy of 1/ 6ns p ! Q _/ 7 7 Setbacks Zone: Solar.
Current E le ``�A ricat tiic..# Exp. Date /� �7
Licenses 3q -330s c / - o/-96 CO - 8() f Q
-L I.0 TO
`COT Business Ta Maud Ex . Date n ineering Apprrval:) Planning Approval: TIF:
I/ / o X1.0 0(6i--1" � 'YD 1Q
sts\stapp -Doc 61-17/ ' v '
m _______,,_,__ , _________I
•
07 08:38 $503 684 7297 CITY OF TIGARD Z003:007
. 4 • I. •• • • !
Permit # Account Description Amount Amt. Pd.. Bal. Due
hs/Sb -0 y32 MST. Permit (BUILD) 698, <u 6 9P •`
Plumb. Permit (PLUMB) .11 " 7 2 S, w
Mech. Permit (MECH) 4 .-/.� `" y S, '«
ELC /ELR Permit (ELPRMT) 3u v 3"
U
State Tax (TAX) 43. V
Bldg: 3 D
Plumb: //• L
Mech: s 22 s
ELC /ELR: /5
Plan Check l
MST: (BUPPLN) 4/53. c�� 0 ,2 03 .71)
Plumb: (PLMPLN)
Mech: (MECPLN) //. z ) _ _ /l. Z. 5
CDC Review (LANDUS) .9 , �u a• v
Sc49L- aisY Sewer Connection (SWUSA) v �2
Sewer Inspection (SWINSP) 3,j _
Parks Dev Charge (PKSDC) /65V /USA
Residential TIF (TIF -R) /57 G I5 7c
Mass Transit TIF (TIF -MT) 12'& _ / Z
Water Quality (WQUAL)
Water Quantity (WQUANT) /UC2 / G
Erosion Control Permit (ERPRMT) vv _ G
Erosion Planck/USA (ERPLAN) rpt :Ge ePe' v
Erosion Planck/COT (EROSN) .71 11iu P p', 4 a
Fire Life Safety (FLS)
TOTALS: 70 561 c( ‘fraios")°.
i:ldstslmstapp.doc
Rev. 7/96
07/18/96 08:40 $503 684- 7297 CITY OF TIGARD Q1006/007
r '
Solar Balance Point Standard Worksheet
Address
Box A calculations: North -South dimension for the lot. Box A:
This dimension is determined by finding the midpoint of the North lot tine and drawing
an intersecting line perpendicular to that point.
First, determine which property line is the North lot line. The North lot line is the line
with the smallest angle from a line drawn east -west and intersecting the northern most
point of the lot
45° \
I
l `CT 'M h R E rV NOiiF?SiN j \ \
` \ lOT LNE
N \\ North-South
✓ Dimension for Lot:
Measure the distance from the midpoint of the North lot line to the South lot line along
the described line. Z 3 feet
j II NCRTI4SeLM CIMENSICNI
1 \ V
Box B calculations: Shade point height for your residence. Box B;
1. Determine whether measurements will be based on the peak or eave of your Which describes
structure. The orientation of the ridge is also important.
your residence?
la: If the roof line runs North- South, measurements will 1i. (circle one)
be based on the peak of the roof.
iii.. III
l® 1B IC
1 b: If the roof line runs East -West and the roof pitch is
less than 5/12. measurements will be based on the
eave.
9_ Ce rT_INT EAf_
1 c: If the roof line runs East -West and the roof pitch is
5/12 or steeper, measurements will be based on the 5 - Isu,,,
peak: r ""p
;H.DE runt 40GE
•
2/14/00 Activities for Case #: MST96 -00432 .
4:35:13 PM .
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA005 Application received 9/6/96 JH RECD B'P 8/14/97
MSTA008 Permit Created 9/12/96 B PEND BON 9/12/96
MSTA010 Check for prd. restrict. 9/6/96 BON 9/12/96
MSTA012 Plans routed to Plans Examiner 9/12/96 B PEND BON 9/12/96
MSTA026 Plans approved by Plans Exmr 9/23/96 RT PASS BT2 9/23/96
MSTA030 Reviewed plans routed to DSTS 9/23/96 RT PASS BT2 9/23/96 .
MSTA705 Footing lnsp 10/30/96 KS APP . KBS 10/31/96 •
MSTA706 Foundation lnsp • 10/30/96 KS APP KBS 10/31/96 •
MSTA710 Post/Beam Structural 11/26/96 RB PASS RB 11/26/96 pending- lateral bracing
MSTA711 Post/Beam Mechanical 11/26/96 RB PASS RB 11/26/96
MSTA713 Crawl Drain BON 9/12/96
MSTA717 PLM /Underfloor 11/13/96 MS PASS MRS 11/14/96 req. nail plates
MSTA720 Mechanical lnsp 1/14/97 KS DIS KBS 1/22/97 #-1- see corrections this date
MSTA722 Plumb Top Out " 1/3/97 MS FAIL MRS 1/6/97 no test .
MSTA723 Electrical Service 1/3/97 MJR PASS MJR 1/6/97
MSTA724 Electrical Rough In 1/3/97 MJR DIS MJR 1/6/97 bath plugs to be on circuit of
there own. electrical and to -volt
both incomplete note: fan box in
entry
MSTA725 Framing Insp 1/14/97 KS DIS KBS 1/22/97 #-1- see framing corrections
this date
MSTA726 Shear Wall Insp 2/5/97 KS APP KBS 2/5/97
MSTA727 Low Voltage BON 9/12/96
MSTA735 Gas Line Insp 1/22/97 KS APP KBS 1/22/97 #-1- gas piping pt test= 22 -psi
for 20 minutes
MSTA740 Insulation lnsp 1/29/97 KS DIS KBS 1/30/97 #-1- see inspection notes
MSTA745 Gyp Board Insp 2/3/97 KS DIS KBS 2/4/97 #-1- need clearance at both B
vents /garage #-2- insulate rturn
air supply duct at garage as
indicated at prior inspection
#-3- shear nailing not done at
this time
MSTA755 Rain drain Insp 11/5/96 MS PAS\ S*W 8/13/97
MSTA760 Water Line lnsp 11/5/96 MS PASS S'W 8/13/97
MSTA765 APPr /Sdwlk Insp 3/24/97 PI PASS RB 3/26/97 APPROACH & UPPER
SIDEWALK OK TO PAVE.
MSTA790 Electrical Final 7/30/97 BRP FAIL B'P 8/14/97 Recept. in bookcase exposed to
wood. 370 -20&21 NEC.
Page 1 of 4
2/14100 • Activities for Case #: MST96 -00432 •
4:35:13 PM
Assigned Hold Updated •
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA797 Plumb Final 6/24/97 RAB PASS JDA 6/27/97
MSTA799 Building Final 8/12/97 ' KS FAIL J'I-1 8/15/97 1. Plumbing final approved
. 062497 2. Need electrical final
& erosion control final
• approvals. 3. Post insulation
certification. 4. Support gas
. pipe at water heater. 5. Seal off
retum lines - AC unit not
installed. 6. Extend handrail at
exterior deck to bottom of
• stairs. 7. Insulate around door
jambs & upper storage areas. 8.
Insulate heat duct supply at
upper storage. 9. Seal crafter
space above b -vent so
•
insulation does not fall into
•
insulation shield. 10. Insulate
. exposed water pipe (hose bibb)
. 11. Support gas piping (1/2"
. - 6' -0" oc; 3/4" 8' -0" oc) 12.
Remove loose wood and debris
at crawl. 13. Clean around low
. point drain.
MSTB708 Erosion Control BON 9/12/96
MSTA080 (F) Ready to issue 9/30/96 CJS . PASS BON 10/4/96 Need electrical contractor info
MSTA098 Issue electric signature form 10/17/96 JT • RECD JT 8/21/97
MSTA097 Issue plumbing signature form 10/17/96 JT RECD JT • 8/21/97
MSTA092 (F) Issue combination permit • 10/17/96 B PASS BON 10/17/96
MSTA726 Shear Wall lnsp 1/3/97 KS • DIS KBS 1/3/97 #-1- no plans on site
MSTA726 Shear Wall lnsp 1/7/97 KS DIS KBS 1/14/97 #-1- shear details show
HTT -22- holdowns at front of
structure #-2- HPAHD -22- .
holdown missed at rear of
garage #-3- MST #/48 /straps
not installed at front of
bedrooms #-4- nail and block all
shear panels per schedule #-5-
subsiding damaged due to
excessive wet condidtions
' • buckling #-6- additional nailing
. needed at generic subsiding
MSTA722 Plumb Top Out 1/8/97 MS PASS • . MRS 1/8/97 •
MSTA727 Low Voltage ' 1/14/97 GS APP GES 1/14/97
MSTA724 Electrical Rough In 1/14/97 GS APP GES 1/14/97 post address be sure mstr tub
. pump access is adaquate
Page2of4 .
2/14/00 Activities for Case #: MST96 -00432
4:35:13 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA727 Low Voltage 1/22/97 GS LVCA GES 1/22/97
MSTA724 Electrical Rough In 1/22/97 GS APP GES 1/22/97
MSTA720 Mechanical Insp 1/22/97 KS DIS - KBS 1/22/97 #-1- see corrections this date
MSTA725 Framing lnsp 1/22/97 KS DIS KBS 1/22/97 #-1- see corrections this date
MSTA725 Framing lnsp 1/24/97 KS APP KBS 1/24/97
MSTA726 Shear Wall lnsp 1/24/97 KS APP KBS 1/24/97
MSTA720 Mechanical Insp 1/24/97 KS A/N KBS 1/24/97 #-1- gypsum not nailed behind
furnace or taped will check at
gypsum inspection
MSTA740 Insulation Insp 1/30/97 KS A/N KBS 1/30/97 #-1- insulate return air supply at
garage will check at gypsum
inspect.
MSTA745 Gyp Board Insp 2/4/97 KS N/R KBS 2/5/97 #-1- canceled by request
MSTA770 Misc. Inspection 3/5/97 KS APP KBS 3/6/97 #-1- slab on grade / garage fl
MSTA724 Electrical Rough In 8/13/97 BRP DIS MJR 8/13/97 need extension where wood
exposed
MSTA780 «REINSPECTION» 8/14/97 B PAID DST 8/14/97 electrical reinspect $35.00 paid
(97- 298290) ,
MSTA790 Electrical Final 8/14/97 BRP FAIL B *P 8/14/97 Wood is still exposed to
receptacle.
MSTA005 Application received 8/14/97 B *P 8/14/97
MSTA790 Electrical Final 8/14/97 BRP FAIL B *P 8/14/97 Wood is still exposed.
MSTA790 Electrical Final 8/18/97 BRP PASS B'P 8/18/97
MSTA790 Electrical Final 8/15/97 BRP PASS B *P 8/19/97
MSTA795 Mechanical Final 8/20/97 KS APP • KBS 8/20/97
MSTA799 Building Final 8/20/97 KS APP KBS 8/20/97
MSTA970 Case Finaled 8/20/97 KS APP KBS 8/20/97
MSTA960 (F) Issue Cert. of Occupancy 8/20/97 S'W 12/3/97 mailed 12 -3 -97
MSTA798 Final inspection 6/24/97 BRP, PASS J *H 9/2/97 1. Refrigerator plug loose, plate .
not flush. 2. Flex conduit under
island not grounded, not
complete. 3. To outlet box, two
locations. 4. Panel schedule
does not comply with
. ART.384 -12 & 110 -22. 5. Circuit
• breakers, panel and cover to be
cleaned of paint, spray texture,
and joint compound untemally
. and externally. Art 210 -52(e)
Rear recept. does not comply
Page 3 of 4
•
2/14/00 Activities for Case #: MST96 -00432
4:35:13 PM
• Assigned Hold Updated .
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA790 Electrical Final 6/24/97 BRP FAIL J *H 9/2/97 1. Refrigerator plug loose, plate
not flush. 2. Flex conduit under
• island not grounded, not
• complete to outlet box, two
locations. 3. Panel schedule
does not comply with ART
384 -12 & 110 -22.4. Circuit •
breakers, panel and cover to be
cleaned of paint, spray texture,
and joint compound internally
• and externally. ART 210 -52(e)
• - rear recept. does not comply. •
•
•
•
•
•
•
•
•
Page 4 of 4
•
Page No. 1 CASE HISTORY FOR CASE NO.: MST96 -0432
BEAR CONSTRUCTION CO
12939 SW RIDGEFIELD LN
12/03/97
Action Description Req/ Schd/ End/ Action Notes Die') By Update Upd
Code Sent Done Done Date By
- - -- --- ----- - -- - --
MSTA005 Application received / / / / 09/06/96 RECD JH 08/14/97 B*P
MSTA005 Application received / / / / 08/14/97 08/14/97 B*P
MSTA008 Permit Created / / / / 09/12/96 PEND B 09/12/96 BON
MSTA010 Check for prcl. restrict. / / / / 09/06/96 09/12/96 BON
MSTA012 Plans routed to Plans Examiner / / / / 09/12/96 PEND B 09/12/96 BON
MSTA026 Plans approved by Plans Exmr / / / / 09/23/96 PASS RT 09/23/96 BT2
MSTA030 Reviewed plane routed to DSTS / / / / 09/23/96 PASS RT 09/23/96 BT2
MSTA080 (F) Ready to issue / / / / 09/30/96 Need electrical contractor info PASS CJS 10/04/96 BON
MSTA092 (F) Issue combination permit / / / / 10/17/96 . PASS B 10/17/96 BON
MSTA097 Issue plumbing signature form / / / / 10/17/96 RECD JT 08/21/97 JT
MSTA098 Issue electric signature form / / / / 10/17/96 RECD JT 08/21/97 JT
MSTA705 Footing Insp / / / / 10/30/96 APP KS 10/31/96 KBS
MSTA706 Foundation Inep / / / / 10/30/96 APP KS 10/31/96 KBS
MSTA710 Poet /Beam Structural / / / / 11/26/96 pending- lateral bracing PASS RB 11/26/96 RB
MSTA711 Post /Beam Mechanical / / / / 11/26/96 PASS RB 11/26/96 RB
MSTA713 Crawl Drain / / / / / / 09/12/96 BON
MSTA717 PLM /Underfloor / / / / 11/13/96 req. nail plates PASS MS 11/14/96 MRS
MSTA720 Mechanical Insp / / / / 01/14/97 # -1- see corrections this date DIS' KS 01/22/97 KBS
MSTA720 Mechanical Inep / / / / 01/22/97 # -1- see corrections this date DIS KS 01/22/97 KBS
MSTA720 Mechanical Insp / / / / 01/24/97 # -1- gypsum not nailed behind furnace or A/N KS 01/24/97 KBS
taped will
check at gypsum inspection
MSTA722 Plumb Top Out / / / / 01/03/97 no test FAIL MS 01/06/97 MRS
MSTA722 Plumb Top Out / / / / 01/08/97 PASS MS 01/08/97 MRS
MSTA723 Electrical Service / / / / 01/03/97 PASS MJR 01/06/97 MJR
MSTA724 Electrical Rough In / / / / 01/03/97 bath plugs to be on circuit of there DIS MJR 01/06/97 MJR
own.
electrical and to -volt both incomplete
note: fan box in entry
MSTA724 Electrical Rough In / / / / 01/14/97 post address APP GS 01/14/97 GES
be sure mstr tub pump access is adaquate
MSTA724 Electrical Rough In / / / / 01/22/97 APP GS 01/22/97 GES
MSTA724 Electrical Rough In / / / / 08/13/97 need extension where wood exposed DIS BRP 08/13/97 MJR
MSTA725 Framing Inep / / / / 01/14/97 # see framing corrections this date DIS KS 01/22/97 KBS
Page No. 2 CASE HISTORY FOR CASE NO.: MST96 -0432
BEAR CONSTRUCTION CO
12939 SW RIDGEFIELD LN
12/03/97
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
- - -- - -- -- ------ - --
MSTA725 Framing Insp / / / / 01/22/97 # -1- see corrections this date DIS KS 01/22/97 KBS
MSTA725 Framing Iasp / / / / 01/24/97 APP KS 01/24/97 KBS
MSTA726 Shear Wall Iasp / / / / 02/05/97 APP KS 02/05/97 KBS
MSTA726 Shear Wall Insp / / / / 01/03/97 # -1- no plans on site DIS KS 01/03/97 KBS
MSTA726 Shear Wall Insp / / / / 01/07/97 # -1- shear details show HTT-22- holdowns DIS KS 01/14/97 KBS
at front of structure
►H93-0lko •4= ..4H9@ -.
garage
# -3- MST #/48 /straps not installed at
front of bedrooms
# -4- nail and block all shear panels per
schedule
# -5- subsiding damaged due to excessive
wet condidtions
buckling
•
# -6- additional nailing needed at
generic subsiding
•
MSTA726 Shear Wall Insp / / / / 01/24/97 APP KS 01/24/97 KBS
MSTA727 Low Voltage / / / / / / 09/12/96 BON
MSTA727 Low Voltage / / / / 01/14/97 APP GS 01/14/97 GES
MSTA727 Low Voltage / / / / 01/22/97 LVCA GS 01/22/97 GEE
MSTA735 Gas Line Insp / / / / 01/22/97 # -1- gas piping pt test= 22 -psi for 20 APP KS 01/22/97 KBS
minutes
MSTA740 Insulation Insp / / / / 01/29/97 # -1- see inspection notes DIS KS 01/30/97 KBS-
.
MSTA740 Insulation Insp / / / / 01/30/97 #-1- insulate return air supply at A/N KS 01/30/97 KBS
garage will check .
at gypsum inspect.
MSTA745 Gyp Board Insp / / / / 02/03/97 # -1- need clearance at both B vents DIS KS 02/04/97 KBS
/garage
#-2- insulate rturn air supply duct at
garage as indicated at prior
inspection
# -3- shear nailing not done at this time
MSTA745 Gyp Board Inep / / / / 02/04/97 # -1- canceled by request N/R KS 02/05/97 KBS
MSTA755 Rain drain Inep / / / / 11/05/96 PAS\ MS 08/13/97 S•W
MSTA760 Water Line Insp / / / / 11/05/96 PASS MS 08/13/97 S ■W
MSTA765 Appr /Sdwlk Inep / / / / 03/24/97 APPROACH & UPPER SIDEWALK OK TO PAVE. PASS PI 03/26/97 RB
Page No. 3 CASE HISTORY FOR CASE NO.:•MST96 -0432
BEAR CONSTRUCTION CO
12939 SW RIDGEFIELD LN
•
12/03/97
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
-- -- - -- -------- - --
MSTA770 Misc. Inspection / / / / 03/05/97 # -1- slab on grade / garage fl APP KS 03/06/97 KBS
MSTA780 ccREINSPECTION» / / / / 08/14/97 electrical reinspect $35.00 paid PAID B 08/14/97 DST
(97- 298290)
MSTA790 Electrical Final / / / / 07/30/97 Recept. in bookcase exposed to wood. FAIL BRP 08/14/97 B *P
370 -20&21 NEC.
' MSTA790 Electrical Final / / / / 08/14/97 Wood is still exposed to receptacle. FAIL BRP 08/14/97 B *P
MSTA790 Electrical Final / / / / 08/14/97 Wood is still exposed. FAIL BRP 08/14/97 B *P
MSTA790 Electrical Final / / / / 08/18/97 PASS BRP 08/18/97 B *P
MSTA790 Electrical Final / / / / 08/15/97 PASS BRP 08/19/97 B *P
MSTA790 Electrical Final / / / / 06/24/97 1. Refrigerator plug loose, plate not FAIL BRP 09/02/97 J *H
flush.
2. Flex conduit under island not
grounded, not complete to outlet box,
two locations.
3. Panel schedule does not comply with
ART 384 -12 & 110 -22.
4. Circuit breakers, panel and cover to
be cleaned of paint, spray texture, and
•
joint compound internally and
externally. ART 210 -52(e) rear recept.
does not comply.
MSTA795 Mechanical Final / / / / 08/20/97 APP KS 08/20/97 ICES
MSTA797 Plumb Final / / / / 06/24/97 PASS RAB 06/27/97 JDA
MSTA798 Final inspection / / / / 06/24/97 1. Refrigerator plug loose, plate not PASS BRP 09/02/97 J *H
flush.
2. Flex conduit under island not
grounded, not complete.
3. To outlet box, two locations.
4. Panel schedule does not comply with
ART.384 -12 & 110 -22.
5. Circuit breakers, panel and cover to
be cleaned of paint, spray texture, and
joint compound unternally and
externally.
Art 210 -52(e) Rear recept. does not
comply
•
•
Page No. 4 CASE HISTORY FOR CASE NO.: MST96 -0432
BEAR CONSTRUCTION CO
12939 SW RIDGEFIELD LN
12/03/97
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
---- - -- -- -- ---- ---
MSTA799 Building Final / / / / 08/12/97 1. Plumbing final approved 062497 FAIL KS 08/15/97 J*H
2. Need electrical final & erosion
control final approvals.
3. Post insulation certification.
4. Support gas pipe at water heater.
5. Seal off return lines - AC unit not
installed.
6. Extend handrail at exterior deck to
bottom of stairs.
7. Insulate around door jambs & upper
storage areas.
8. Insulate heat duct supply at upper
storage.
9. Seal crafter space above b -vent so
insulation does not fall into insulation
shield.
10. Insulate exposed water pipe (hose
bibb)
11. Support gas piping (1/2" 6' -0" oc;
3/4" 8' -0" oc)
12. Remove loose wood and debris at
crawl.
13. Clean around low point drain.
MSTA799 Building Final / / / / 08/20/97 APP KS 08/20/97 KBS
MSTA960 (F) Issue Cert. of Occupancy / / / / 08/20/97 mailed 12 -3 -97 12/03/97 S *W
MSTA970 Case Finaled / / / / 08/20/97 APP KS 08/20/97 KBS
MSTB708 Erosion Control / / / / / / 09/12/96 BON
•
I \ —
CITY OF TIGARD BUILDING INSPECTION DIVISION
24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171 t
Date Requested: 0 - - ( A.M. P.M. MST: f� ___—
Location: 4..2-9'3 9 eidgeZ ( o'T /) BUP:
Tenant: Suite: Bldg: MEC:
Contractor: 64,,g A k 3)--ruat Phone: ( %&2 3 5 1 PLM:
Owner: Phone: ELC:
-,a_. / /01 . I . / I ' CIAO ' /! ��.
_ . — 8 p^
076. ELR:
/ l Ca?.70 If SIT:
BUILDING BLD on't) PLUMBING CHANIC ELECTRICAL SITE
Site ostBeam Post/Beam Post/Beam Cover /Service Sewer /Storm
Footing Roof UndFl/Slab Rough -In Ceiling Water Line
Slab Framing Top Out Gas Line Rough -In UG Sprinkler
Foundation Insulation Sewer Hood/Duct Reconnect Vault
Bsmt Damp Drywall Storm Furnace Temp Service MISC.
Masonry Ceiling Rain Drain A/C UG Slab
Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump Low Volt
. Approved Approved Approved Approved
Appr /Sdwlk 0.- -=.•,: .ved Not Approved Not roved Not Approved Not Approved
FINAL QUI FINAL (11 FINAL FINAL
0 Z.I.G./ "I 4L, 2 S, ...c i os/0A".) :.-+ - G c ' A f'P
•
0 Call for reinspect' n 0 Reinspection fee of $ a required before next inspection 0 Unable to inspect
Inspector: ,. p Date: - 2e,- 97 Page of