Loading...
Permit OFTIGARD CITY ,.. „„,, ., DEVELOPMENT SERVICES MASTER PERMIT �VI PERM I T # • MST96 -04 �2 - 13125 SW Nall Blvd., Tigard, OR 97223 503 639.4171 DATE ISSUED: 10 17 / T9 PARCEL: 2S104DD -01800 SITE ADDRESS...: 12939 SW RIDGEFIELD LN SUBDIVISION • MOUNTAIN HIGHLANDS #2 ZONING: R -4.5 PD BLOCK . LOT • 015 Remarks: Path 1 - - -- BUILDING --- - — REISSUE: STORIES : 2 FLOOR AREAS ---- BASEMENT...: 0 sf REQUIRED SETBACKS— REQUIRED — CLASS OF WORK.:NEW HEIGHT • 25 FIRST • 1277 sf GARAGE • 876 sf LEFT • 8 SMOKE DETECTRS: Y TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 1559 sf FRONT • 20 PARKING SPACES: 1 TYPE OF CONST.:5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 30 OCCUPANCY 6RP.:R3 BDRM: 4 BATH: 3 TOTAL------: 2836 sf VALUE..$: 205216 REAR • 49 PL ' ° i:INS - - - - - -- SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 1 RAIN DRAIN ft: 0 TRAPS : 0 LAVATORIES • 5 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 1 CATCH BASINS..: 0 TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 1% BCKFLW PREVNTR: 1 GREASE TRAPS..: 0 OTHER FIXTURES: 0 MECHANICAL -- FUEL TYPES FURN ( 1'AK ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1 /GAS/ / / FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1 MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS : 0 WOODSTOVES : 0 GAS OUTLETS...: 1 ELECTRICAL -- - RESIDENTIAL UNIT— — SERVICE /FEEDER -- —TEMP SRVC /FEEDERS— — BRANCH CIRCUITS— - -- MISCELLANEOUS— — ADD'L INSPECTIONS - 1m SF OR LESS: 1 0 - 200 alp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 6 201 - 400 amp..: 0 201 - 400 alp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF HM /SVC /FDR: 0 601 - 1-"' amp.: 0 601+amps- 1m v: 0 MINOR LABEL -10: 0 1m + amp /volt.: 0 -- -- PLAN REVIEW SECTION - - -- Reconnect only.: 0 )4 RES UNITS..: SVC /FDR ?=225 A.: > 600 V NOMINAL: CLS AREA /SPC OCC: - - -- — -- ELECTRICAL - RESTRICTED ENERGY - -- — A. SF RESIDENTIAL- B. COMMERCIAL -- — -- - -- AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: OTH: :: X BOILER HVAC • LANDSCAPE /IRRIG: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL • OTHR: .. HVAC DATA /TELE COMM.: NURSE CALLS TOTAL # SYSTEMS: 0 Owner: -------- -------- -- Contractor: — — TOTAL FEES:$ 4821.55 BEAR CONSTRUCTION CO BEAR CONSTRUCTION CO 8076 SW 184TH AVE 8076 SW 184TH AVE BEAVERTON OR 97w BEAVERTON OR 97007 Phone #: 642 -3512 Phone #: 642 -3512 Reg #..: 17098 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. -- -- — REQUIRED INSPECTIONS ----------------------------------------------- -- Footing Insp PLM /Underfloor Framing Insp 6as Fireplace Water Service In Building Final Foundation Insp Mechanical Insp Shear Wall Insp Insulation Insp Appr /Sdwlk Insp Erosion Control Post /Beam Struct Plumb Top Out Low Voltage Gyp Board Insp Electrical Final Post /Beam Meehan Electrical Servi ireplace Insp Rain drain Insp Mechanical Final Crawl Drain Electrical Rough Il s Line ! sp Water Line Insp Plu Final A OVA,' AA Permittee Signature: A" 4� Issued By: I/ Call for inspection — 639 -4175 07 08:37 '8`503 68-1 7297 CITY OF TIGARD , . . Q002/007 Plan Check # -Z[ CITY OF TIGARD Residential Building Permit Application Reed ayI 13125 SW HALL BLVD. New Construction Additions or Alterations Date Recd - - "1GARD, OR 97223 Single Family Detached or Attached Dale to P.E: J z 42 303) 639 -4171 Date to DST '.2 Print or Type Permit # 5 ' - s 32- Called i7- 4 - / Incompletle or illegible applications will not be accepted Name of Subdivision I1 iHL,d t of > F . N Job 1 T J .J . �o k 10 4 i -- z- Address Site Address — Architect !!Aaiun ddress 1A937 Stec *e g t dd. Live SW �PQ !State Bp Phone Name 1 # k) 1 Owner Mailing Address I L 610 ICH' City/State Zip k Phone Engineer .91dress 5 co gilt-44. -�.a me 1 7 S (o tate p Phone General R um `�' Co - Describe work caw addition 0 alteration 0 repair 0 Contractor :ling Address t d Sic] 1651' /� �TUL to be done: _ Additional Description of Work: f 1 !State p hone Off, • ii, l?on7 p hone 35 i a- Oregon Const Cant. oard tic# E= Da Attach opy of 1 70S8� 57 I ( Y7 Project Current COT ^ OS. / ine T r tro # Ex a �( Licenses ' .. to Valuation 3 / gL NEW CONSTRUCTION ONLY: Mechanical _ Al , 'Z,J • Sq•Ft_ Hous Sq_FtGarage: , 1 _, Sub Ma f S T&fYI g Address NC � 'Y Contractor ty Stu reik0 Corner Lot Yes No Flag Lot Yes No� ‘ V Ci / zip ���rr on (check one) ) (check one) . tZ.Q 'Sd)7 Restricted Audio /Stereo Burglar regon Const Cont. =card Licit Exp. to / /g 7 e System Alarm Attach Copy of - • - ±A Energy rgY Current T Bu -mess T_� fZ � Exp. Date Installation ✓ Garage Door HVAC Licenses / " =- °� - 0 _ __ Opener 1 ,,/ -... Systems x . e t... ii/ - I (check all that Other. Plumbing .,S . -r.i(2.. apply) Sub- Mailing Address Will the electrical subcontractor wire for all Yes I;1¢ q restricted energy installations? Contractor /C7 , �� � Has the Subdivision Plat recorded? N/A X�.s No. 0 \k I �c'�O Zip �O ' 407!6 ' Oregon Conn Cont. SAaro Lic.s Exp. date Reissue of MST# Solar Compliance t.... Attach Copy oft/ Ef12- 7 ei (Calculation Attached) Currant • JP umbing tic. # Exp. Data I hereby acknowledge that I have read this application, that the Licenses I/ 3 * -(/ 5 3Q_97 information given is • - that I am the owner or authorized agent of COT Business Tax r Metro ` Exp. Date the r, aril • at s submitted are in compliance with Oregon 96 y -7 C. stata : , e Sig n j. �'e t ..r.. / 9.(� Electrical k ra Zic..c_ of _ Con' MairAilMinalli none Sub- Mailing Address � �� V 3 3 Contra $ _ sc�) V T , W L- FOR OFFICE USE ONLY: _ 0\1 +, r ate- n Zip Phone Plat # C MaprTL#: ) C Ore non o»ont Board Lic.# Ex& . Da q �r " J I `� v - (r'1'` O Attach Copy of 1/ 6ns p ! Q _/ 7 7 Setbacks Zone: Solar. Current E le ``�A ricat tiic..# Exp. Date /� �7 Licenses 3q -330s c / - o/-96 CO - 8() f Q -L I.0 TO `COT Business Ta Maud Ex . Date n ineering Apprrval:) Planning Approval: TIF: I/ / o X1.0 0(6i--1" � 'YD 1Q sts\stapp -Doc 61-17/ ' v ' m _______,,_,__ , _________I • 07 08:38 $503 684 7297 CITY OF TIGARD Z003:007 . 4 • I. •• • • ! Permit # Account Description Amount Amt. Pd.. Bal. Due hs/Sb -0 y32 MST. Permit (BUILD) 698, <u 6 9P •` Plumb. Permit (PLUMB) .11 " 7 2 S, w Mech. Permit (MECH) 4 .-/.� `" y S, '« ELC /ELR Permit (ELPRMT) 3u v 3" U State Tax (TAX) 43. V Bldg: 3 D Plumb: //• L Mech: s 22 s ELC /ELR: /5 Plan Check l MST: (BUPPLN) 4/53. c�� 0 ,2 03 .71) Plumb: (PLMPLN) Mech: (MECPLN) //. z ) _ _ /l. Z. 5 CDC Review (LANDUS) .9 , �u a• v Sc49L- aisY Sewer Connection (SWUSA) v �2 Sewer Inspection (SWINSP) 3,j _ Parks Dev Charge (PKSDC) /65V /USA Residential TIF (TIF -R) /57 G I5 7c Mass Transit TIF (TIF -MT) 12'& _ / Z Water Quality (WQUAL) Water Quantity (WQUANT) /UC2 / G Erosion Control Permit (ERPRMT) vv _ G Erosion Planck/USA (ERPLAN) rpt :Ge ePe' v Erosion Planck/COT (EROSN) .71 11iu P p', 4 a Fire Life Safety (FLS) TOTALS: 70 561 c( ‘fraios")°. i:ldstslmstapp.doc Rev. 7/96 07/18/96 08:40 $503 684- 7297 CITY OF TIGARD Q1006/007 r ' Solar Balance Point Standard Worksheet Address Box A calculations: North -South dimension for the lot. Box A: This dimension is determined by finding the midpoint of the North lot tine and drawing an intersecting line perpendicular to that point. First, determine which property line is the North lot line. The North lot line is the line with the smallest angle from a line drawn east -west and intersecting the northern most point of the lot 45° \ I l `CT 'M h R E rV NOiiF?SiN j \ \ ` \ lOT LNE N \\ North-South ✓ Dimension for Lot: Measure the distance from the midpoint of the North lot line to the South lot line along the described line. Z 3 feet j II NCRTI4SeLM CIMENSICNI 1 \ V Box B calculations: Shade point height for your residence. Box B; 1. Determine whether measurements will be based on the peak or eave of your Which describes structure. The orientation of the ridge is also important. your residence? la: If the roof line runs North- South, measurements will 1i. (circle one) be based on the peak of the roof. iii.. III l® 1B IC 1 b: If the roof line runs East -West and the roof pitch is less than 5/12. measurements will be based on the eave. 9_ Ce rT_INT EAf_ 1 c: If the roof line runs East -West and the roof pitch is 5/12 or steeper, measurements will be based on the 5 - Isu,,, peak: r ""p ;H.DE runt 40GE • 2/14/00 Activities for Case #: MST96 -00432 . 4:35:13 PM . Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA005 Application received 9/6/96 JH RECD B'P 8/14/97 MSTA008 Permit Created 9/12/96 B PEND BON 9/12/96 MSTA010 Check for prd. restrict. 9/6/96 BON 9/12/96 MSTA012 Plans routed to Plans Examiner 9/12/96 B PEND BON 9/12/96 MSTA026 Plans approved by Plans Exmr 9/23/96 RT PASS BT2 9/23/96 MSTA030 Reviewed plans routed to DSTS 9/23/96 RT PASS BT2 9/23/96 . MSTA705 Footing lnsp 10/30/96 KS APP . KBS 10/31/96 • MSTA706 Foundation lnsp • 10/30/96 KS APP KBS 10/31/96 • MSTA710 Post/Beam Structural 11/26/96 RB PASS RB 11/26/96 pending- lateral bracing MSTA711 Post/Beam Mechanical 11/26/96 RB PASS RB 11/26/96 MSTA713 Crawl Drain BON 9/12/96 MSTA717 PLM /Underfloor 11/13/96 MS PASS MRS 11/14/96 req. nail plates MSTA720 Mechanical lnsp 1/14/97 KS DIS KBS 1/22/97 #-1- see corrections this date MSTA722 Plumb Top Out " 1/3/97 MS FAIL MRS 1/6/97 no test . MSTA723 Electrical Service 1/3/97 MJR PASS MJR 1/6/97 MSTA724 Electrical Rough In 1/3/97 MJR DIS MJR 1/6/97 bath plugs to be on circuit of there own. electrical and to -volt both incomplete note: fan box in entry MSTA725 Framing Insp 1/14/97 KS DIS KBS 1/22/97 #-1- see framing corrections this date MSTA726 Shear Wall Insp 2/5/97 KS APP KBS 2/5/97 MSTA727 Low Voltage BON 9/12/96 MSTA735 Gas Line Insp 1/22/97 KS APP KBS 1/22/97 #-1- gas piping pt test= 22 -psi for 20 minutes MSTA740 Insulation lnsp 1/29/97 KS DIS KBS 1/30/97 #-1- see inspection notes MSTA745 Gyp Board Insp 2/3/97 KS DIS KBS 2/4/97 #-1- need clearance at both B vents /garage #-2- insulate rturn air supply duct at garage as indicated at prior inspection #-3- shear nailing not done at this time MSTA755 Rain drain Insp 11/5/96 MS PAS\ S*W 8/13/97 MSTA760 Water Line lnsp 11/5/96 MS PASS S'W 8/13/97 MSTA765 APPr /Sdwlk Insp 3/24/97 PI PASS RB 3/26/97 APPROACH & UPPER SIDEWALK OK TO PAVE. MSTA790 Electrical Final 7/30/97 BRP FAIL B'P 8/14/97 Recept. in bookcase exposed to wood. 370 -20&21 NEC. Page 1 of 4 2/14100 • Activities for Case #: MST96 -00432 • 4:35:13 PM Assigned Hold Updated • Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA797 Plumb Final 6/24/97 RAB PASS JDA 6/27/97 MSTA799 Building Final 8/12/97 ' KS FAIL J'I-1 8/15/97 1. Plumbing final approved . 062497 2. Need electrical final & erosion control final • approvals. 3. Post insulation certification. 4. Support gas . pipe at water heater. 5. Seal off retum lines - AC unit not installed. 6. Extend handrail at exterior deck to bottom of • stairs. 7. Insulate around door jambs & upper storage areas. 8. Insulate heat duct supply at upper storage. 9. Seal crafter space above b -vent so • insulation does not fall into • insulation shield. 10. Insulate . exposed water pipe (hose bibb) . 11. Support gas piping (1/2" . - 6' -0" oc; 3/4" 8' -0" oc) 12. Remove loose wood and debris at crawl. 13. Clean around low . point drain. MSTB708 Erosion Control BON 9/12/96 MSTA080 (F) Ready to issue 9/30/96 CJS . PASS BON 10/4/96 Need electrical contractor info MSTA098 Issue electric signature form 10/17/96 JT • RECD JT 8/21/97 MSTA097 Issue plumbing signature form 10/17/96 JT RECD JT • 8/21/97 MSTA092 (F) Issue combination permit • 10/17/96 B PASS BON 10/17/96 MSTA726 Shear Wall lnsp 1/3/97 KS • DIS KBS 1/3/97 #-1- no plans on site MSTA726 Shear Wall lnsp 1/7/97 KS DIS KBS 1/14/97 #-1- shear details show HTT -22- holdowns at front of structure #-2- HPAHD -22- . holdown missed at rear of garage #-3- MST #/48 /straps not installed at front of bedrooms #-4- nail and block all shear panels per schedule #-5- subsiding damaged due to excessive wet condidtions ' • buckling #-6- additional nailing . needed at generic subsiding MSTA722 Plumb Top Out 1/8/97 MS PASS • . MRS 1/8/97 • MSTA727 Low Voltage ' 1/14/97 GS APP GES 1/14/97 MSTA724 Electrical Rough In 1/14/97 GS APP GES 1/14/97 post address be sure mstr tub . pump access is adaquate Page2of4 . 2/14/00 Activities for Case #: MST96 -00432 4:35:13 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA727 Low Voltage 1/22/97 GS LVCA GES 1/22/97 MSTA724 Electrical Rough In 1/22/97 GS APP GES 1/22/97 MSTA720 Mechanical Insp 1/22/97 KS DIS - KBS 1/22/97 #-1- see corrections this date MSTA725 Framing lnsp 1/22/97 KS DIS KBS 1/22/97 #-1- see corrections this date MSTA725 Framing lnsp 1/24/97 KS APP KBS 1/24/97 MSTA726 Shear Wall lnsp 1/24/97 KS APP KBS 1/24/97 MSTA720 Mechanical Insp 1/24/97 KS A/N KBS 1/24/97 #-1- gypsum not nailed behind furnace or taped will check at gypsum inspection MSTA740 Insulation Insp 1/30/97 KS A/N KBS 1/30/97 #-1- insulate return air supply at garage will check at gypsum inspect. MSTA745 Gyp Board Insp 2/4/97 KS N/R KBS 2/5/97 #-1- canceled by request MSTA770 Misc. Inspection 3/5/97 KS APP KBS 3/6/97 #-1- slab on grade / garage fl MSTA724 Electrical Rough In 8/13/97 BRP DIS MJR 8/13/97 need extension where wood exposed MSTA780 «REINSPECTION» 8/14/97 B PAID DST 8/14/97 electrical reinspect $35.00 paid (97- 298290) , MSTA790 Electrical Final 8/14/97 BRP FAIL B *P 8/14/97 Wood is still exposed to receptacle. MSTA005 Application received 8/14/97 B *P 8/14/97 MSTA790 Electrical Final 8/14/97 BRP FAIL B *P 8/14/97 Wood is still exposed. MSTA790 Electrical Final 8/18/97 BRP PASS B'P 8/18/97 MSTA790 Electrical Final 8/15/97 BRP PASS B *P 8/19/97 MSTA795 Mechanical Final 8/20/97 KS APP • KBS 8/20/97 MSTA799 Building Final 8/20/97 KS APP KBS 8/20/97 MSTA970 Case Finaled 8/20/97 KS APP KBS 8/20/97 MSTA960 (F) Issue Cert. of Occupancy 8/20/97 S'W 12/3/97 mailed 12 -3 -97 MSTA798 Final inspection 6/24/97 BRP, PASS J *H 9/2/97 1. Refrigerator plug loose, plate . not flush. 2. Flex conduit under island not grounded, not complete. 3. To outlet box, two locations. 4. Panel schedule does not comply with . ART.384 -12 & 110 -22. 5. Circuit • breakers, panel and cover to be cleaned of paint, spray texture, and joint compound untemally . and externally. Art 210 -52(e) Rear recept. does not comply Page 3 of 4 • 2/14/00 Activities for Case #: MST96 -00432 4:35:13 PM • Assigned Hold Updated . Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA790 Electrical Final 6/24/97 BRP FAIL J *H 9/2/97 1. Refrigerator plug loose, plate not flush. 2. Flex conduit under • island not grounded, not • complete to outlet box, two locations. 3. Panel schedule does not comply with ART 384 -12 & 110 -22.4. Circuit • breakers, panel and cover to be cleaned of paint, spray texture, and joint compound internally • and externally. ART 210 -52(e) • - rear recept. does not comply. • • • • • • • • • Page 4 of 4 • Page No. 1 CASE HISTORY FOR CASE NO.: MST96 -0432 BEAR CONSTRUCTION CO 12939 SW RIDGEFIELD LN 12/03/97 Action Description Req/ Schd/ End/ Action Notes Die') By Update Upd Code Sent Done Done Date By - - -- --- ----- - -- - -- MSTA005 Application received / / / / 09/06/96 RECD JH 08/14/97 B*P MSTA005 Application received / / / / 08/14/97 08/14/97 B*P MSTA008 Permit Created / / / / 09/12/96 PEND B 09/12/96 BON MSTA010 Check for prcl. restrict. / / / / 09/06/96 09/12/96 BON MSTA012 Plans routed to Plans Examiner / / / / 09/12/96 PEND B 09/12/96 BON MSTA026 Plans approved by Plans Exmr / / / / 09/23/96 PASS RT 09/23/96 BT2 MSTA030 Reviewed plane routed to DSTS / / / / 09/23/96 PASS RT 09/23/96 BT2 MSTA080 (F) Ready to issue / / / / 09/30/96 Need electrical contractor info PASS CJS 10/04/96 BON MSTA092 (F) Issue combination permit / / / / 10/17/96 . PASS B 10/17/96 BON MSTA097 Issue plumbing signature form / / / / 10/17/96 RECD JT 08/21/97 JT MSTA098 Issue electric signature form / / / / 10/17/96 RECD JT 08/21/97 JT MSTA705 Footing Insp / / / / 10/30/96 APP KS 10/31/96 KBS MSTA706 Foundation Inep / / / / 10/30/96 APP KS 10/31/96 KBS MSTA710 Poet /Beam Structural / / / / 11/26/96 pending- lateral bracing PASS RB 11/26/96 RB MSTA711 Post /Beam Mechanical / / / / 11/26/96 PASS RB 11/26/96 RB MSTA713 Crawl Drain / / / / / / 09/12/96 BON MSTA717 PLM /Underfloor / / / / 11/13/96 req. nail plates PASS MS 11/14/96 MRS MSTA720 Mechanical Insp / / / / 01/14/97 # -1- see corrections this date DIS' KS 01/22/97 KBS MSTA720 Mechanical Inep / / / / 01/22/97 # -1- see corrections this date DIS KS 01/22/97 KBS MSTA720 Mechanical Insp / / / / 01/24/97 # -1- gypsum not nailed behind furnace or A/N KS 01/24/97 KBS taped will check at gypsum inspection MSTA722 Plumb Top Out / / / / 01/03/97 no test FAIL MS 01/06/97 MRS MSTA722 Plumb Top Out / / / / 01/08/97 PASS MS 01/08/97 MRS MSTA723 Electrical Service / / / / 01/03/97 PASS MJR 01/06/97 MJR MSTA724 Electrical Rough In / / / / 01/03/97 bath plugs to be on circuit of there DIS MJR 01/06/97 MJR own. electrical and to -volt both incomplete note: fan box in entry MSTA724 Electrical Rough In / / / / 01/14/97 post address APP GS 01/14/97 GES be sure mstr tub pump access is adaquate MSTA724 Electrical Rough In / / / / 01/22/97 APP GS 01/22/97 GES MSTA724 Electrical Rough In / / / / 08/13/97 need extension where wood exposed DIS BRP 08/13/97 MJR MSTA725 Framing Inep / / / / 01/14/97 # see framing corrections this date DIS KS 01/22/97 KBS Page No. 2 CASE HISTORY FOR CASE NO.: MST96 -0432 BEAR CONSTRUCTION CO 12939 SW RIDGEFIELD LN 12/03/97 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By - - -- - -- -- ------ - -- MSTA725 Framing Insp / / / / 01/22/97 # -1- see corrections this date DIS KS 01/22/97 KBS MSTA725 Framing Iasp / / / / 01/24/97 APP KS 01/24/97 KBS MSTA726 Shear Wall Iasp / / / / 02/05/97 APP KS 02/05/97 KBS MSTA726 Shear Wall Insp / / / / 01/03/97 # -1- no plans on site DIS KS 01/03/97 KBS MSTA726 Shear Wall Insp / / / / 01/07/97 # -1- shear details show HTT-22- holdowns DIS KS 01/14/97 KBS at front of structure ►H93-0lko •4= ..4H9@ -. garage # -3- MST #/48 /straps not installed at front of bedrooms # -4- nail and block all shear panels per schedule # -5- subsiding damaged due to excessive wet condidtions buckling • # -6- additional nailing needed at generic subsiding • MSTA726 Shear Wall Insp / / / / 01/24/97 APP KS 01/24/97 KBS MSTA727 Low Voltage / / / / / / 09/12/96 BON MSTA727 Low Voltage / / / / 01/14/97 APP GS 01/14/97 GES MSTA727 Low Voltage / / / / 01/22/97 LVCA GS 01/22/97 GEE MSTA735 Gas Line Insp / / / / 01/22/97 # -1- gas piping pt test= 22 -psi for 20 APP KS 01/22/97 KBS minutes MSTA740 Insulation Insp / / / / 01/29/97 # -1- see inspection notes DIS KS 01/30/97 KBS- . MSTA740 Insulation Insp / / / / 01/30/97 #-1- insulate return air supply at A/N KS 01/30/97 KBS garage will check . at gypsum inspect. MSTA745 Gyp Board Insp / / / / 02/03/97 # -1- need clearance at both B vents DIS KS 02/04/97 KBS /garage #-2- insulate rturn air supply duct at garage as indicated at prior inspection # -3- shear nailing not done at this time MSTA745 Gyp Board Inep / / / / 02/04/97 # -1- canceled by request N/R KS 02/05/97 KBS MSTA755 Rain drain Inep / / / / 11/05/96 PAS\ MS 08/13/97 S•W MSTA760 Water Line Insp / / / / 11/05/96 PASS MS 08/13/97 S ■W MSTA765 Appr /Sdwlk Inep / / / / 03/24/97 APPROACH & UPPER SIDEWALK OK TO PAVE. PASS PI 03/26/97 RB Page No. 3 CASE HISTORY FOR CASE NO.:•MST96 -0432 BEAR CONSTRUCTION CO 12939 SW RIDGEFIELD LN • 12/03/97 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By -- -- - -- -------- - -- MSTA770 Misc. Inspection / / / / 03/05/97 # -1- slab on grade / garage fl APP KS 03/06/97 KBS MSTA780 ccREINSPECTION» / / / / 08/14/97 electrical reinspect $35.00 paid PAID B 08/14/97 DST (97- 298290) MSTA790 Electrical Final / / / / 07/30/97 Recept. in bookcase exposed to wood. FAIL BRP 08/14/97 B *P 370 -20&21 NEC. ' MSTA790 Electrical Final / / / / 08/14/97 Wood is still exposed to receptacle. FAIL BRP 08/14/97 B *P MSTA790 Electrical Final / / / / 08/14/97 Wood is still exposed. FAIL BRP 08/14/97 B *P MSTA790 Electrical Final / / / / 08/18/97 PASS BRP 08/18/97 B *P MSTA790 Electrical Final / / / / 08/15/97 PASS BRP 08/19/97 B *P MSTA790 Electrical Final / / / / 06/24/97 1. Refrigerator plug loose, plate not FAIL BRP 09/02/97 J *H flush. 2. Flex conduit under island not grounded, not complete to outlet box, two locations. 3. Panel schedule does not comply with ART 384 -12 & 110 -22. 4. Circuit breakers, panel and cover to be cleaned of paint, spray texture, and • joint compound internally and externally. ART 210 -52(e) rear recept. does not comply. MSTA795 Mechanical Final / / / / 08/20/97 APP KS 08/20/97 ICES MSTA797 Plumb Final / / / / 06/24/97 PASS RAB 06/27/97 JDA MSTA798 Final inspection / / / / 06/24/97 1. Refrigerator plug loose, plate not PASS BRP 09/02/97 J *H flush. 2. Flex conduit under island not grounded, not complete. 3. To outlet box, two locations. 4. Panel schedule does not comply with ART.384 -12 & 110 -22. 5. Circuit breakers, panel and cover to be cleaned of paint, spray texture, and joint compound unternally and externally. Art 210 -52(e) Rear recept. does not comply • • Page No. 4 CASE HISTORY FOR CASE NO.: MST96 -0432 BEAR CONSTRUCTION CO 12939 SW RIDGEFIELD LN 12/03/97 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By ---- - -- -- -- ---- --- MSTA799 Building Final / / / / 08/12/97 1. Plumbing final approved 062497 FAIL KS 08/15/97 J*H 2. Need electrical final & erosion control final approvals. 3. Post insulation certification. 4. Support gas pipe at water heater. 5. Seal off return lines - AC unit not installed. 6. Extend handrail at exterior deck to bottom of stairs. 7. Insulate around door jambs & upper storage areas. 8. Insulate heat duct supply at upper storage. 9. Seal crafter space above b -vent so insulation does not fall into insulation shield. 10. Insulate exposed water pipe (hose bibb) 11. Support gas piping (1/2" 6' -0" oc; 3/4" 8' -0" oc) 12. Remove loose wood and debris at crawl. 13. Clean around low point drain. MSTA799 Building Final / / / / 08/20/97 APP KS 08/20/97 KBS MSTA960 (F) Issue Cert. of Occupancy / / / / 08/20/97 mailed 12 -3 -97 12/03/97 S *W MSTA970 Case Finaled / / / / 08/20/97 APP KS 08/20/97 KBS MSTB708 Erosion Control / / / / / / 09/12/96 BON • I \ — CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171 t Date Requested: 0 - - ( A.M. P.M. MST: f� ___— Location: 4..2-9'3 9 eidgeZ ( o'T /) BUP: Tenant: Suite: Bldg: MEC: Contractor: 64,,g A k 3)--ruat Phone: ( %&2 3 5 1 PLM: Owner: Phone: ELC: -,a_. / /01 . I . / I ' CIAO ' /! ��. _ . — 8 p^ 076. ELR: / l Ca?.70 If SIT: BUILDING BLD on't) PLUMBING CHANIC ELECTRICAL SITE Site ostBeam Post/Beam Post/Beam Cover /Service Sewer /Storm Footing Roof UndFl/Slab Rough -In Ceiling Water Line Slab Framing Top Out Gas Line Rough -In UG Sprinkler Foundation Insulation Sewer Hood/Duct Reconnect Vault Bsmt Damp Drywall Storm Furnace Temp Service MISC. Masonry Ceiling Rain Drain A/C UG Slab Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump Low Volt . Approved Approved Approved Approved Appr /Sdwlk 0.- -=.•,: .ved Not Approved Not roved Not Approved Not Approved FINAL QUI FINAL (11 FINAL FINAL 0 Z.I.G./ "I 4L, 2 S, ...c i os/0A".) :.-+ - G c ' A f'P • 0 Call for reinspect' n 0 Reinspection fee of $ a required before next inspection 0 Unable to inspect Inspector: ,. p Date: - 2e,- 97 Page of