Plans 1"))))))))))))))))) Michael Pfohl • Architectural Acoustics (503) 288 -3415 3515 NE 27th Ave. Portland. Olt 47212 3.3.97 RECEIVED Plans Examiner MAR ® 3 1997 City of Tigard, OR 13125 SW Hall Blvd COMMUNITY DEVEL®PMENT Tigard OR 97223 RE: ImageBuilders - Building Plan Review 6650 SW Redwood Lane PC#: 2 -25c BUP #:97 -0070 The following is a response towards compliance with the 1996 Oregon Specialty Codes and other applicable codes and standards in regards to the ImageBuilders recording studio project: risjAA 150 1 . 7 _i 1. Energy Compliance PA " The size of the project is less than 450 sq.ft.. Oregon Non - Residential Lighting Load Compliance Forms 5a -5c are non - applicable because the project is less than 2000sq.ft. total. 2. Accessibility This project is new construction. The building complies 100% with ADA guide lines. Barrier removal considerations are therefore non - applicable since the site is already in compliance. Environmental controls shall comply to the 54" side reach / 44" forward reach guide lines. 3. Fire and S ety T e 2 -A fire extinguishers provided within 75' accessibility guide lines. `see plan Entry-doors and frames shall provide at least a 20 minute fire rating. All walls abutting the one hour corridor shall be constructed as set out in OSSC, section 1005.7. /A glass/glazing shall be tempered (2406.4(6)) Arwood framing shall provide fire blocking in concealed spaces (OSSC section 708.2.1) All paces shall be sprinidered *see plans 4. Structural `see attached suspended ceiling detail. 5. Mechanical / Fire sprinkler 'separate applications and plans shall be submitted. These descriptions shall guarentee full compliance with all required OSSC codes and considerations. Sincerely, 7-4, Michael Pfohl Architectural Acoustics w t ... 1 • • FLOOR AND /OR ROOF STRUCTURE STABILIZER BAR BETWEEN MAINS AT PERIMETER ADDITIONAL HANGERS AT ALL MAINS WITHIN 8" OF THE PERIMETER APPROVED VERTICAL STRUT AT 12' -0 O.C. EA. WAY WITH 4 WAY LATERAL RUNNER TO THE STRUCTURE OVER. BEGIN WITHIN 6' -0" OF THE PERIMETER & 2" FROM A CROSS MEMBER - 8• CROSS MEMBERS BETWEEN • MAX. MAIN RUNNERS MAIN RUNNERS AT 4' -0" O.C. 6-0" MAX SUPPORT WITH *12 WIRE AT 4'-O" O.C. OR WITH SIO WIRE ATS'- O" O.C. COUNTERSLOPE HANGERS IF MORE THAN t6 OUT OF PLUMB SECURE ALL HANGERS TO BLDG. STRUCTURE OR A TRAPEZE FOR DUCT MID /OR PIPE WORK SUSPENDED CEILING I3RACING NOTE: ALL CONNECTION DEVICES TO BE UBC N.T.C. APPROVED TYPE AND HAVE I00# CAPACITY r. • • O I ' d 1, \ Q to ng OM II li z-o- J. z _ ^DOITIONAL 51NIT I GANG LOCATION Iii TO / = u 1l o ouTLET 1 14 1 • Mal \ IS i 1 UNDERCUT DOOR -- � ___ FLOOR FI NIS H - 6 STANDARD MOUNTING HEIGHTS WV SCALE 1/2" = l'-0" v5, February 18, 1997 EXPO!, En „4,4- Michael Pfohl CITY OF TIGARD 3515 NE 27th OREGON Portland, OR 97212 RE: Image Builders p,.4 Building Plan Review 6650 SW Redwood Lane PC #: 2 -25c BUP #: 97 -0070 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1996 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: � C{' Cy Ei� 1 '� ��` C a r S''•�'1 TI 1. Submit Oregon Non - Residential Lighting Load Compliance Forms 5a through 5c. _ _ 1. An amount equal to 25% of the remodeling cost shall be budgeted for removal of architectural barriers within the site and tenant space. • A. Barrier removal is determined in accordance with OSSC, Section 1113.1:1, ORS 447.241 (4). B. . The barrier removal plan shall include exterior improvements. 2. The environmental control (thermostat) and lighting controls shall not be located more than 54' above finish floor for accessible side reach approach or 44' for forward approach [Section 1109.2.3.6]. • 1. Provide Type 2 -A fire extinguishers throughout so that the travel distance to a unit . does not exceed 75 feet [NFPA 10 3.2.1]. 2. Entry doors and frames from the existing one -hour corridor shall have a fire - protection rating of not less than 20 minutes. 3. Walls extending the limits of your proposed tenant space, abutting the one -hour corridor, shall be constructed as set out in OSSC, Section 1005.7. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Image Builders Building Plan Review • PC#: 2 -25c • BUP #: 97 -0070 Page #2 • 4. Glazing, in fixed or operable panels, adjacent to a door where the nearest exposed edge of the glazing is within a 24° arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60° above the walking surface, shall be tempered [2406.4(6)]. 5. Provide fire blocking in all concealed spaces [OSSC, Section 708.2.1]. 6. Point of information: all concealed spaces must be sprinklered. * 'Y-�.r. rqi r >a �i:- � • )� °� r �?. •` ' .: •'. %- g 9•:`�'° ... ,�_ - ynq y � = V # \i' j i .• _� 6.A.. - . ;c; `t! :�'^ e :,i'! K '` ? �,.di ,%J i , �Ti:i -- °:? a.... 1. The suspended acoustical ceiling system shall be anchored to resist lateral seismic forces [Section 1630.2 and Table 16Q]. Provide suspension wires not smaller than No. 12 gauge spaced at 4' on center, perimeter wires on terminal ends of cross and main runners at a maximum of 8° from each wall, four No. 12 gauge wires splayed 90 degrees from each other at an angle not exceeding 45 degrees from the plane of the ceiling with a strut centered and extending to the structural members supporting the floor or roof above and spaced 12' on center in both directions starting 6' from each wall. All lighting fixtures weighing less than 56 lbs. shall be positively attached to the suspended ceiling system [ASTM C635 -94]. When using an intermediate grade system, No. 12 gauge wires shall be attached to the grid members within 3° of each corner of the fixtures, and lighting fixtures weighing less than 56 lbs. shall have two No. 12 slack wires • connected from the fixture to the structure above. Ceiling mounted air terminals or services weighing less than 20 lbs. shall be positively attached to ceiling runners. Provide an illustration. F r6 rt+ ( 9 s T c _^ p T - Separate applications and plans are required. Please submit three copies of revised submittal documents and a letter indicating your response to the above comments for review. Please call me at (503) 639 -4171 if you have any questions. Sincerely, 6 o ert Poskm, CBO PLANS EXAMINER T. _00.701PQ- 46C.DOC