Correspondence ,(.± v.i?'- o . r c ), qP 0. (O Q ^� 7 June 3, 1997 Mr. Robert Poskins, CBO Plans Examiner • City of Tigard 13125 S.W. Hall Boulevard Tigard, Oregon 97223 Project: BUP# 97 -0197 Subject: Addendum #2 Dear Robert, Please find attached a revised partial floor plan for the above noted project. This is being submitted as Addendum #2. The change required is the elimination of the motion testing area and the revised location of the lunchroom. These will be sent to the contractor currently on site and they will be directed to indude this into the permit documents. Please let me know if this meets with your approval, or if you would like further clarification. .i cerely / i, P C.Jacob. ini.'. F: - end: M A H L U M cc: Joe Dinsdale, Andersen Construction & N o R D F O R S S M I T H trad n o, GORDON Architects PC 1231 Northwest Hoyt Suite 102 Portland, OR 97209 503 224 4032 503 224 0918 F • • Mr. Robert Poskins, CBO City of Tigard Physical Therapy Clinic Tenant Space Plan Review Response BUP# 97 -0197 May 13, 1997 Page 2 FIRE SPRINKLER/ALARMS 1. A fire sprinkler plan and application will be submitted by the appropriate sub - contractor. Bob, I hope this meets with your approval, please contact me if I can offer further clarification. cere , , r Proj - . • !er M cc: Jo Dinsdale, Andersen Construction James Speilman, Andersen Construction 96220 /coderev • May 13, 1997 Mr. Robert Poskins, CBO Plans Examiner City of Tigard 13125 S.W. Hall Blvd. Tigard, Oregon 97223 Project: Physical Therapy Clinic /Orthopedic & Fracture Clinic Sisters of Providence Subject: Plan Review Response BUP# 97 -0197 Dear Robert, Please find listed below responses to your review comments dated April 28, 1997. Note that a number of issues have been addressed in the core and shell drawings associated with this projet. I have indicated this in my replies. RGY COMPLIANCE </ . The completed Energy Compliance Forms 5a through 5c will be submitted by the it:1) appropriate subcontractor. Electrical lighting calculations will also be submitted by the � ap propriate subcontractor for the Orthopedic & Fracture Clinic per your verbal request. ACC ILITY . Ref -to attached details of shower stalls showing compliance with OSSC, Section M A H L U M & N O R D F O R S 09.10.10. • SMITH GO.R DON At least one of -each type of lockers complies with OSSC, Section 1109.17.1 and 2. A:tect5 P C FIRE AND 1 E SAFETY Northwest Hoyt Suite 102 Portland, OR 1. Exit signs will be located at the following doors: Door "A" entering the waiting room from 97209 Corridor 345 and at Door "C" at Corridor 337. An exit sign with an arrow pointing towards the double doors in Corridor 343 will be centered on the opposing wall from the door. 503 224 4032 503 224 0918 F RECEIVED MAY U 5 1991 April 28, 1997 = MAHLUM & NORDFORS CITY OF TIGAR® Mahlum & Nordfors Smith Gordon SMITH GORDON 50 SW Second Avenue #600 OREGON Portland, OR 97204 RE: Physical Therapy Clinic Building Plan Review Sisters of Providence 6640 SW Redwood Lane Occupancy: B /A3 Occupant Load: B = 27 A3 =31 PC #: 04-71C BUP#: 97 -0197 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1996 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: ENERGY `COMPLIANCE 1. Submit Completed Energy Compliance Forms 5a through 5c, Oregon Non - Residential Energy Code. • , ACCESSIBILITY 1. Provide details showing compliance with OSSC, Section 1109.10.10, shower stalls. 2. Where lockers are provided, at least one of each type shall comply with OSSC, Section 1109.17.1 and 2. FIRE AND LIFE SAFETY. - 1. Provide exit signs at the door labeled "A" entering the waiting room from Corridor 345 and at the door labeled "C" at Corridor 337. Place an exit sign with an arrow pointing towards the double doors in Corridor 343. The sign shall be centered on the opposing wall from the doors, centered [OSSC, Section 1013]. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Physical Therapy Clinic Building Plan Review PC #: 04-71C BUP #: 97 -0197 Page #2 FIRE `SPRINKLEiALARMS 1. Separate plans and application will be required. Please submit four copies of revised submittal documents and a letter indicating your response to the above comments for review. Please call me at (503) 639- 4171 if you have any questions. Sincerely, Ro ert Poskin, CBO PLANS EXAMINER j:\prmsys\documentthup97_01.97\pc4-71_c.doc