Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OFTIGARD DEVELOPMENT SERVICES BUILDING PERMIT "''� �'I'� PERMIT # • PUP96 -0566 -'. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639.4171 DATE ISSUED: 12/30/96 PARCEL: 2S112DA -01300 SITE ADDRESS...: 06640 SW REDWOOD LN SUBDIVISION • MLP96 -0002 ZONING: BLOCK . LOT • REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION — CLASS OF WORK.:NEW FIRST 8306 sf N: S: E: W: TYPE OF USE...:COM SECOND...: 8352 sf PROTECT OPENINGS? TYPE OF CONST.:2N THIRD ...: 8306 sf N:N S:N E:N W:N OCCUPANCY GRP.:B TOTAL : 24964 sf ROOF CONST:BFIRE RET ?:N OCCUPANCY LOAD: 251 BASEMENT.: 0 sf AREA SEP. RATED: STOR.: 3 HT: 45 ft GARAGE...: 0 sf OCCU SEP. RATED: BSMT ?:N MEZZ ?:N READ SETBACKS REQUIRED FLOOR LOAD •100 psf LEFT: 0 ft RGHT: 0 ft FIR SPKL:Y SMOK DET..:Y DWELLING UNITS: 0 FRNT: 0 ft REAR: 0 ft FIR ALRM:Y HNDICP ACC:Y BEDRMS: 0 BATHS: 0 IMP SURFACE: 0 PRO CORR:Y PARKING: 0 VALUE. $ : 1517710 Remarks: 24,964 square foot medical clinic, w/ Providence as the master tenant (Portland Clinic and others at discretion of Providence). SHELL ONLY Stairs and core by separate permit. ' Owner: FEES PAC TRUST REALTY type amount by date recpt 15350 SW SEQUOIA PKWY PLCK $ 0.00 10/29/96 96- 285877 FIRE $ 0.00 10/29/96 96- 285877 TIGARD OR 97224 EROS $ 380.25 B 12/30/96 96- 288261 Phone #: 624 -6300 ERPC $ 123.58 B 12/30/96 96- 288261 ERPC $ 123.58 B 12/30/96 96- 288261 Contractor: SPCT $ 198.90 B 12/30/96 96- 288261 ANDERSEN CONSTRUCTION PRMT $ 3978.00 B 12/30/96 96- 288261 6712 N. CUTTER CIRCLE PLCK $ 2585.70 B 12/30/96 96-288261 PO BOX 6712 Additional fees not shown here PORTLAND OR 97228 Phone #: 283 -6712 $ 9079.99 TOTAL Reg #..: 63053 REQUIRED INSPECTIONS This perait is issued subject to the regulations contained in the Foot /Found Insp Tigard Municipal Code, State of Ore. Specialty Codes and all other Struc Steel Insp applicable laws. All work will be done in accordance with R e i n f Steel Insp approved plans. This permit will expire if work is not started Slab Insp within 180 days of issuance, or if work is suspended for lore Tilt—up Pnl Insp than 180 days. Masonry Insp Framing Insp Insulation Insp Shear Wall Insp Permittee Si ature: .A4..,� �•� Gyp Board Insp Susp Ceilng Insp Issued By: • 40- "— Misc. Inspection Call for inspection — 639 -4175 . , ,6L /-nR- o /2)aL Co mercial BuilinT it Application J , -' Cfty�ot Tigard � 1 - � - . • • � i, • • � 13125 SW Hall Blvd. c� I � N �U 1 • Tigard, OR 9 7223 � I �'� /a') n,14 ` 2C' (503) 639 -4171 I .1A �`� / I e Add ress: !�� D � � 1 , v cJ o ,1 TO GPe ( ©3U q 6 J ots t O Y � ci\ ::. }' s : .:•'• + .:.,y;::. C >,. }i \ \. ::: \c k ?,; I 5!7 711 w : •: } w : > : } ? :;1 `;:, \\< .:;i> >': Va � • / .. t' .,-r ' ? _ . / • .r,..._.. tii �':. ::, T Y} M 4y; 1 , .,.. }: ?.•. ?ti':� \ti \:: } ii }''i:' }'i ' � \� }:.. ^ ^) fir Yf \ V V ?: TT r Ow r: ne Ste' � ;ti::\ }viii`.. ,• \.tiii:::: :: ;L: {:::t:L2 •:.:v \�:? \Y,if'b }�;::, i;'.},X: \::,:•y }v }4R5`:4v.'vv \•f.:+ n�::.�:i ;4': }in: ? {'v: 'i::}'ryii}; � 4: } \ `i'2.v'Y,. \ ", . :0 i :.S\:ti }:n' 'n:titit::t:: i ::: :.::•]};:\ti: }\:?h' }$': Address: 5 , 0 W. i D r :. �, :<; f 3 S Sk t7 � �Kw`I• >:: }:,:;:: �::;» . >:::::, tit: <:«;;<::<; >: < �<::<: y ;`.;::«::::: >:::: <::: > }:: >: ,::<:: >:< ::. '1�e2'`LA b 01�- 9 't 2--41-1 } :. ♦�. <,<;a> }> �', {; h� ..;: \ \} \.i } {:� \v ?�i4S')ViL }'�\ Q� \ \1'•`:ti : ::i. �' 2 ".::: ?.: { "tiL i':J,•i }fti2'4 }p Phone. CZ� Lloo Fia G2`f ?7s ti5�� er x ?':.. ... , }.o:..:`,' ^'+. :. .:..:':a• } }. : .}':.: : : : o ,w} Contractor: � N>nE/2S�►� (o/JS't- � D. ..... } ,. ,..::}>'. �:.?. .. .::.::.:,< .:. ...�.: ?: > >;:: »::< . . • : <� : .. • .. . .. .. : ... AtP% Address: 10 ? (2 N, Gd11 re.4 c O ?J - 0 - - 0,)-J 4f4 e(.i cspec Type of const: —04 ,. Th- rL,oa.f p 0 F. • 7-2-sil - Occupancy lass: • if iu i ` Phone: ZB3- x'11 (PAx 27 3 - 360 I S C.�2 T• 31 Sprinklered? aP No Contractors L # t 0 53 0 I - taus 1 i (o .,,F., 30�d (attach copy of current Oregon l Sq. ft. of pro ject: 2" q(„ SF "Ft"'- I I• 3c6 SE Contact name & phone: 1E 7)11.1SDAL- Story (1st, 2nd, etc.) 2, z s;F• $ GG� 3 i30 tP` Architect/Engineer: 4.A(9 (fP A A 6K Z 1)� Y • Proposed use: MEDI c Gl. Ir f C Previous use: Address: !'0. no PC C ? b Y 9 Note: Plumbing & mechanical plans P012TL/�r+y> 01 , Q ?zoI -OID must be submitted at time of O Phone: Z 1 5 C. (r 2zg - 1285 building permit application. JOB DESCRIPTION: 3- STbl2� TL ! — (11° SJJICW lL A- p1tx 41. CLANG, 2 7.d rLoolrS 5ll1� o � � L • L r 1° 2. S ►• t:. - C : 1 s ,�� ,,�� NO \i, N© mf�.4 -1 -Ff PAM v1/4 17 . - au_ 40 ' • �� - �s1M13 ( ,a„. '.. b vi' L. idia-0 ( l y -g rli ) Applicant Signatu e & P one number Received by: 9 Date Received: / — 9 6 Permit � Account Description A � nt Amt. Pd. Bal. Due 3 Q Z9 ` % Bldg. Perm �fiU, Permit '- ' • (BUILD) -3(o ✓ 'n�'7 Ct' Plumb. Permit (PLUMB) • Mech. Permit (MECH) State Tax (TAX) / q� �° 5 _. Bldg: _ __ .... -- _ . -- ... . _ gg' Plumb: Caa /`- ��'(/� /9/ 78 Mach: i 866 , 1o;-- .5' 5,7D ++ 7161.15g Plan Check (PLANCK) I � ! Bldg: Plumb: '7 ~ Mech: 7 - / 7 ra/cie ________,- ..._ - - Sewer Connection (SWUSA) Sewer Inspection (SWINSP) Parks Dev Charge (PKSDC) Residential TIF (TIF -R) `/ � �� � ��� ,l Mass Transit TIF (TIF -MT) 7 ,1 L(o• _g V - 7 , /26 . / 0 1 � 'I Commercial TIF (TIF -C) °� '9b ' i v , 3I Industrial TIF (TIF -I) ✓Q ° Institutional TIF (TIF -IS) 50 I Office TIF (TIF -0) 5 L___ 926.2 71 P 7 )- 10,)- 7 r v' V Water Quality (WQUAL) . ),,lotitP9 Water Quantity (WQUANT) _ 72 7, 3 / v V 3 ' c Fire Life Safety (FLS) , I � 7 5' Erosion Cntrl Permit (ERPRMT) Aga' a- ✓ 3 S 13) 'z 4 - . "' 1 /6 :1' lz 3,C;(0 Erosion Planck/USA (ERPLAN) -'' Erosion Planck/COT (EROSN) /d?' V / F= Cg TOTALS: 5O- 55 0 Iwo • 5,705: 79 60M' gitAse2 6 (796, W Page No. 1 CASE HISTORY FOR CASE NO.: BUP96 -0566 GROUP MACKENZIE 06640 SW REDWOOD LN 05/13/98 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Dane Date By - - -- --- -- - ----- --- BUPC007 Application received / / / / 10/29/96 DETERMINE CORRECT VALUE FROM JIM FUNK JMH 12/24/96 RDP BUPC008 Permit created / / / / 10/30/96 JMH 10/30/96 PHN BUPC010 Check for prcl. restrict. / / / / 10/30/96 Do not hold plan review for non- complete PEND JMH 12/26/96 J *H partition - forthcoming. Brian signed off MLP 12- 26 -96' BUPC015 Plans routed to Plans Examiner / / -- / / 10/30/96, JMH 10/30/96 PHN BUPC018 Plan Review Ltr. to Ofc. Svcs. / / / / 12/09/96 PEND RDP 12/09/96 RDP BUPCO20 Revised Plans Received / / / / 12/13/96 APPR RDP 12/24/96 RDP BUPCO24 Plans Approved /Routed to DST5 / / / / 12/24/96 APPR RDP 12/24/96 RDP BUPC100 (F) Issue permit / / / / 12/30/96 PASS B 12/30/96 BON BUPC460 Devel review ccnd_. met / / / / 10/14/96 DONE JDA'10/14/97 JDA ,BUPC705 Foot /Found Inep 11/19/96 / / 01/16/96 PASS TLP 01/24/97 TLP BUPC705 Foot /Found Inep / / / / 02/06/97 PASS TLP 02/07/97 TLP BUPC705 Foot /Found Insp / / / / 02/10/97 PASS TLP 02/11/97 TLP BUPC705 Foot /Found Inep / / / / 06/23/97 FOR TRASH BIN ENCLOSURE PASS TLP 06/23/97 J *H BUPC716 Reinf Steel.Insp 11/19/96 / / 01/13/97 • PASS TLP 01/24/97 TLP BUPC725 Slab Insp 11/19/96 / / 02/25/97 PASS TLP 02/26/97 TLP BUPC726 Tilt -up Pnl Insp 11/19/96 / / 03/29/97 PASS TLP 03/31/97 TLP BUPC726 Tilt -up Pnl Insp / / / / 04/10/97 PASS TLP 04/10/97 TLP BUPC726 Tilt -up Pnl Insp / / / / 04/23/97 #s 6,9,22 APP GS 04/23/97 GES BUPC727 Masonry Inep 11/19/96 / / 06/05/97 CARLSON TO DO SPECIAL INSPECTIONS AND APP TLP 06/08/97 J *H REPORT TO THIS CASE - RE: SLAB, 2ND & 3RD FLOOR BUPC740 Framing Inep / / / / 07/30/97 3rd floor APP TLP 08/01/97 J *H BUPC750 Insulation Insp / / / / 07/30/97 PASS TLP 01/27/98 J *H BUPC757 Shear Wall Inep 11/19/96 /'' / 04/23/97 PASS TLP 01/27/98 J *H BUPC760 Gyp Board Insp / / / / 07/30/97 APP TLP 08/01/97 J *H BUPC762 Susp Ceilng Insp / / / / 07/30/97 APP TLP 08/01/97 J *H BUPC792 Misc. Inspection 11/19/96 / / 01/20/97 e mail dated october 14 between Will D., NOTE JT 10/21/97 JT Brian R., Jill A. Will said okay to issue C /O. Jill states that Brian has also signed off on SDR95024. However, many "1" status building permits. BUPC802 Final Inspection / / / / 01/27/98 PASS TLP 01/27/98 J *H BUPC960 Case Finaled / / / /- 05/13/98 5/13/98 plan sent to microfilm 05/13/98 JT • CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171 Date Requested: 27 Gi A.M. P.M. MST: Location: / / 4 II _ i /� I®i�_f�/ / �1 BUP: /0" 0 Tenant: '. tLO IJ1 /' / 5 / II Suite: Bldg: MEC: Contractor: i // / l I . 4, it ,I Phone: d J 6'7 I c "J PLM: Owner: AA ,, / r'y�p Phone: ELC: _ /(/ (V 1- - 0 u f �- - ELR: SIT: BUILDING [�. ceest? PLUMBING MECHANICAL ELECTRICAL SITE Site -Post7Heam Post/Beam Post/Beam Cover /Service Sewer /Storm Footing Roof UndFl/Slab Rough -In Ceiling Water Line Slab Framing Top Out Gas Line Rough -In UG Sprinkler Foundation Insulation Sewer Hood/Duct Reconnect Vault Bsmt Damp Drywall Storm Furnace Temp Service MISC. Masonry Ceiling Rain Drain A/C UG Slab Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump Low Volt �� Approved Approved Approved Approved Appr /Sdwlk Not Approved Not Approved Not Approved Not Approved Not Approved j FINAL FINAL FINAL FINAL O Call for rein , , 0 Reinspection fee of $ required before next inspection 0 Unable to inspect Inspector: Date: / —a / '/ge Page of