Loading...
Permit CITY OF TIGARD MECHANICAL � k DEVELOPMENT SERVICES PERMIT 13125 SW 639-4171 CES PERMIT # MEC98 -0399 DATE ISSUED: 09/24/98 PARCEL: 2511OCD -00114 SITE ADDRESS...: 11755 SW QUEEN ELIZABETH ST SUBDIVISION • KING CITY NO. 2 ZONING: BLOCK • LOT JURISDICTION: KIN CLASS OF WORK..:ALT FLOOR FURN • 0 EVAP COOLERS: 0 TYPE OF USE °COM UNIT HEATERS..: 0 VENT FANS...: 2 OCCUPANCY GRP..:B VENTS W/0 APPL: 0 VENT SYSTEMS: 0 STORIES • 1 BOILERS /COMPRESSORS HOODS • 0 FUEL TYPES 0 -3 HP • 2 DOMES. INCIN: 0 :GAS 3 -15 HP • 0 COMML. INCIN: 0 MAX INPUT: 0 BTU 15 -30 HP • 0 REPAIR UNITS: 0 FIRE DAMPERS ?..: 30 - 50 HP ° 0 WOODSTOVES..: 0 GAS PRESSURE...: 50+ HP • 0 CLO DRYERS..: 0 NO. OF UNITS AIR HANDLING UNITS OTHER UNITS.: 0 FURN < 1O0K BTU: 0 <= 10000 cfm: 0 GAS OUTLETS.: 1 FURN > =1O0K BTU: 2 > 10000 cfm: 0 Remarks : Add mechanical for a new Dental Lab. Owner: FEES MOOKI DENTAL LAB type amount by date recpt 11870 SW KING JAMES PLACE PRMT $ 47.00 DEB 09/24/98 98- 309476 KING CITY OR 97224 PLCK $ 11.25 DEB 09/24/98 98- 309476 SPCT $ 2.25 DEB 09/24/98 98- 309476 Phone #: Contract or: AIR COMFORT INC 6800 NE 59TH PLACE $ 60.50 TOTAL PORTLAND OR 97182 Phone #: 287 -2888 Reg #..: 000588 REQUIRED INSPECTIONS This permit is issued subject to the regulations contained in the Gas Line Insp Tigard Municipal Code, State of Ore. Specialty Codes and all other Mechanical Insp applicable laws. All work will be done in accordance with Heating Unt Insp approved plans. This permit will expire if work is not started Cooling Unt Insp within 180 days of issuance, or if work is suspended for more Duct Inspect ion than 180 days. ATTENTION: Oregon law requires you to follow rules Misc. I n s pe ct i o n adopted by the Oregon Utility Notification Center. Those rules are Final Inspection set forth in OAR 952- 001-0010 through OAR 952-001-0880. You may F,..i r.o=tz,;-a.r, obtain copies of these rules or direct questions to OIJNC by calling (503)246 -9187. Issue B L /Y�'L,�Q c � Perm S ignatu re: A d ." T � ++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ Call 639 -4175 by 7:00 p.m. for inspections needed the next business day ++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ CITY.OF TIGARD Mechanical Permit Application Plan Check #O 3 / C° _ PP Rec'd By 13125 SW HALL BLVD. Commercial and Residential Date Rec'd y -iy-y$-- TIGARD, OR 97223 Date to P.E. ''4-- (503) 639 -4171, x304 Date to DST ' • d 'r, 1' 401( ,�� Print or Type y,� -� /oq Permit# (/ J ;t 0 3WJ Incomplete or illegible applications w not be accepted Called i� 98 s 5 3 Name of Development/Pro ect Description J M OO is / e Table 1A Mechanical Code Qty Price Job StreetAddre , A) Permit Fee y' ':, 10.00 Address /✓�7,5v � J 1) Furnace to 100,000 BT .� including duds 8 vents 6.00 `/ Bldg# eC`rty/ r ate Q Zip 2) Furnace 100,000 BTU+ � including ducts & vents Z, 7.50 `�j Name (or name of business) 3) Floor Furnace including vent 6.00 Owner Mailing Addre n i " " i4/4/) 4) Suspended heater, wall heater / 2 :. 5 Vent floor mounted heater 6.00 fie, Vent not included in appliance permit ag� {�tte Zip Phone ien 3.00 Ot � /� CHECK ALL 'Boiler Heat Air • Na me or name of business) THAT APPLY: or Pump Cond Qty Price Amt / ) / /-J Comp Comp .. M ai in Address .// 6) <3HP;absorb unit to l � Occupant g 14 P�� 7) 3-15 BTU 6.00 / 7,�,Jr s , 7) 3 -15 HP;absorb unit City /State Zip Phone 100k to 500k BTU 11.00 • OG %7 u) unit . 5-1 mi l absorb unit .5 -1 mil BTU 15.00 Contractor Na 9) 30-50 HP; absorb #,M, t 7 r7C unit 1 -1.75 mil BTU 22.50 Prior to permit ailing Ad ress 10) >50HP; absorb unit issuance, a copy 6 t�� r,�� I Q, >1.75 mil BTU 37.50 of all licenses /St Zip Phone � 11) Air handling unit to 10,000 CFM are required if /p / _ � 9 y ' j, , 7 .7�r 4.50 expired in COT Oregon Const. Cont. Boa c.# Exp. Date 12) Air handling unit 10,000 CFM+ database ur",P <- I ) s -oC) 7.50 Architect Name 13) Non - portable evaporate cooler /A �Q 1 ./ - 4.50 or Mailing9�33r v S' 444 / 14) Vent fan connected to a single duct / a0 c °° i i _ /i 3.00 ( / Lit/ . < 15) Ventilation system not included in Engineer C / °1d1 /O `, ,� Zip <3IJ,� appliance permit 4.50 drl Q , I 21 -3O'L 16) Hood served by mechanical exhaust Describe work to be done: ` ' 4.50 17) Domestic incinerators New V Repair 0 Replace with like kind: Yes 0 No 0 7.50 Residential 0 Commercial 0 18) Commercial or industrial type incinerator 30.00 Additional information or description of work: 19) Repair units 4.50 • 20) Wood stove AI c /. 4.50 21) Clothes dryer, etc. • 4.50 Type of fuel: oil 0 natural gas 'LPG 0 electric 0 22) Other units 4.50 I hereby acknowledge that I have read this application, that the information 23) Gas piping one to four outlets ao given is correct, that I am the owner or authorized agent of 1 2.00 the owner, that plans submitted are in compliance with Oregon State laws. 24) More than 4 -per outlet (each) .50 Signature of Owner /Agent Date ������ ���� Minimum Permit Fee $25.00 SUBTOTAL mow lwu 9/# �t� 5% SURCHARGE Contact Person Name Phone a PLAN REVIEW 25% OF SUBTOTAL AI ' A' % ^I � ils p Required for ALL commercial permits only on , V v / 015 EA/ 8 Q TOTAL *State Contractor Boiler Certification required "Residential A/C requires site plan showing placement of unit I:knechperm.doc rev 07/20/98 • KING CITY 15300 S.W. 116th Avenue, King City, Oregon 97224.2693 ® Phone: (503) 639 -4082 • FAX (503) 639-3771 Notice To Contractors Working In King City Due to an intergovernmental agreement with the City of Tigard, many building related permits for projects in King City are issued and inspected by the City of Tigard. If your permit application DOES NOT REQUIRE PLAN REVIEW, simply complete the appropriate application legibly and submit it to the King City staff. The King City staff will collect all fees and fax the application to the City of Tigard. City of Tigard staff will then create the permit, issue the permit, and perform inspections. Please indicate on the permit application whether you would like the Tigard staff to call you when the permit is ready for issuance or whether you prefer it to be mailed without any notification. Any incomplete or illegible application will be returned to King City staff for correction and no processing will occur until a complete, legible application is received. If your permit application DOES REQUIRE PLAN REVIEW, this form must be signed by a King City' staff person. King City staff will simply sign this form indicating land use approval. Take this signed form to the City of Tigard Development Services Counter located at 13125 SW Hall Blvd, Tigard, to submit applications and plans. Development Services Technicians are available at 639 -4171 Ext. 304 should you have any questions concerning submittal requirements. All permit fees will be assessed and collected at the City of Tigard. The City of King City hereby authorizes applicant to pursue permits at the City of Tigard Building Department for the following project: 1 14/ w PtfaJ c2Z located at: /5755 Jc) & M 16062,- King City Representative I: DSTS\KCINST.000 Page No. 1 • CASE HISTORY FOR CASE NO.: MEC98 -0399 MOOKI DENTAL LAB • 11755 SW QUEEN ELIZABETH ST • 03/02/99 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By -- -- - -- -- - - - - -- - -- MECC007 Application received / / / / 09/14/98' RECD GEO 09/15/98 GEO MECC008 Permit created / / / / 09/15/98 DONE GEO 09/15/98 GEO MECCOII Routed to Plans Examiner / / / / 09/15/98 SENT GEO 09/15/98 GEO MECC012 Plan Review Ltr. to Ofc. Svcs. 09/16/98 / / 09/16/98 PEND RDP 09/16/98 RDP MECC014 Plan checked /Approved by P.E. / / / / 09/23/98 APPR RDP 09/23/98 RDP MECC015 Reviewed Plans Routed to DSTS / / / / 09/23/98 APPR RDP 09/23/98 RDP MECC016 DST Post- Review Completed / / / / 09/23/98 PASS JSD 09/23/98 JSD MECCO50 (F) Ready to issue / / / / 09/23/98 PASS JSD 09/23/98 JSD MECC090 (F) Issue permit / / / / 09/24/98 DONE DEB 09/24/98 DST MECC705 Gas Line dnsp 09/23/98 / / 11/03/98 Gas tag # 340543 PASS RC 02/05/99 ROC MECC705 Gas Line Insp / / / / 02/11/99 INTERAL GAS LINE ADDED AT WORK STATIONS PASS RC 02/12/99 ROC AND ROOMS AFTER GAS TEST,LINE NEEDS TESTING BEFORE CONNECTING TO MAIN GAS LINE GAS LINE AT WORK STATIONS APP. MECC706 Mechanical Insp 09/23/98 / / 10/27/98 Mechanical not ready - resubmit plans FAIL RC 10/27/98 J *H for revisions (show mechanical room & • fireplace) 1. Mechanical not ready. 2. No pressure on line. 3. Unsure of gas pressure. • 4. Mechanical permit does not include fireplace, please revise. MECC706 Mechanical Insp / / / / 10/30/98 $15.00 reinspection fee-assessed for FAIL RC 11/02/98 J *H corrections not completed: 1. Bath fans need to be connected at rough in - 2nd notice. 2. Need combustion air ducts in furnace rooms at roughin. 3. Instructions for fireplace not at site. • • MECC706 Mechanical Insp 11/04/98 / / 11/03/98 1. Insufficient combustion air for FAIL RC 11/04/98 J *H' mechanical room with furnace and water heater. What is input rating of water heater (100 square inches is required for furnace alone. 2. Mechanical room by bathrooms requires 80 square inches of air (4x14 = 56 square inches). 3. Opening needs to be covered with • 1/4 -inch mesh screen. MECC706 Mechanical Insp 11/04/98 / / 11/04/98 PASS RC 11/05/98 J *H • Page No. 2 CASE HISTORY FOR CASE NO.: MEC98 -0399 MOOKI DENTAL LAB 11755 SW QUEEN ELIZABETH ST 03/02/99 Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MECC725 Heating Unt Insp 09/23/98 / / / / 09/23/98 RDP MECC730 Cooling Unt Insp 09/23/98 / / / / 09/23/98 RDP MECC735 Duct Inspection 09/23/98 / / / / 09/23/98 RDP MECC750 Misc. Inspection 09/23/98 / / / / 09/23/98 RDP MECC755 «REINSPECTION» / / / / 10/30/98 2nd notice mechanical errors from PAID RC 11/02/98 JSD 103098. Paid 98- 310505 11/02/98 jsd MECC799 Final Inspection / / / / / / 09/15/98 GEO MECC799 Final Inspection 09/23/98 / / 02/25/99 PASS RC 02/25/99 ROC MECC799 Final Inspection / / / / 02/24/99 1. AIR FOR COMPRESSOR CAN NOT HAVE FAIL RC 02/24/99 ROC CLOSURE 2. LOUVERED COVERS CANNOT BE PLACED ON COMB. AIR INTAKE. THEY REDUCE AIR NEEDED FOR COMBUSTION. MECC799 Final Inspection / / / / 02/25/99 PASS .RC 02/25/99 ROC MECC800 Case Finaled / / / / 03/02/99 03/02/99 JT • •