Correspondence 74
June 4, 1997 s �
Oregon Electric Group
CITY OF TIGARD
1010 SE 11th OREGON
Portland, OR 97214
RE: Sister of Providence Building Plan Review
6640 SW Redwood Lane
PC #: 5 -175c BUP #: 97 -0287
97 -0284 1 00
97- 285
97 -0286
NOTICE TO APPLICANT
Under the provisions of the Oregon Structural Specialty Code and National Fire Code,
an alarm system is not required for the subject structure. The plan review and
subsequent permit issuance is based on compliance to OSSC, Section 1109.1.4 and
NFC, Section 1007.3.3. With this in mind, the following items require your attention.
1. Drawing E 6.20S - Provide a pull station near line 5c on the wall at the exit stairs,
' across from the elevator, and a strobe in stairwell, line 3c.
r y 2. Drawing E 6.30S - Provide a strobe at 3rd floor landing, line 6b.
3. Drawing E 6.1P - Provide a strobe in corridor 345.
,J >4 Drawing E 6.1P - Provide a pull station adjacent to exit door in corridor 337.
ti Drawing E 6.1 - Provide a pull station behind door entering rooms 322 - 321 -
319, corridor 320.
6. Drawing E 6.1 - Provide a strobe in toilet room 311.
Please submit four copies of revised submittal documents and a letter indicating your
response to the above comments for review. Please call me at (503) 639 -4171 if you
have any questions.
Sincerely,
R & y,
ert Poskin, CBO
PLANS EXAMINER
13125 SW Hcll Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772