Permit CITY TI G A R D MECHANICAL PERMIT
PERMIT #: MEC1999 -00326
� 4 1 DEVELOPMENT SERVICES DATE ISSUED: 09/16/1999
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 PARCEL: 2S110CD -00104
SITE ADDRESS: 11735 SW QUEEN ELIZABETH ST
SUBDIVISION: KING CITY NO. 2 ZONING:
BLOCK: LOT: JURISDICTION: KIN
CLASS OF WORK: NEW FLOOR FURN: EVAP COOLERS:
TYPE OF USE: COM UNIT HEATERS: VENT FANS: 6
OCCUPANCY GRP: B VENTS W/O APPL: VENT SYSTEMS:
STORIES: 1 BOILERS /COMPRESSORS HOODS:
FUEL TYPES 0 - 3 HP: 6 DOMES. INCIN:
LPG 3 - 15 HP: COMML. INCIN:
MAX INPUT: BTU 15 - 30 HP: REPAIR UNITS:
FIRE DAMPERS ?: 30 - 50 HP: WOODSTOVES:
GAS PRESSURE: M 50 + HP:
FURN < 100K BTU: AIR HANDLING UNITS CLO DRYERS:
FURN > =100K BTU: 6 < =10000 cfm: OTHER UNITS:
> 10000 cfm: GAS OUTLETS: 6
Remarks: Mechanical work for new office building.
Owner: FEES
JACK MEDAK Type By Date Amount Receipt
4029 NE SANDY BLVD PRMT BON 09/16/19E $181.90 99- 318380
PORTLAND, OR 97212 PLCK BON 09/16/19E $45.48 99- 318380
5PCT BON 09/16/19E $12.73 99- 318380
Phone: Total $240.11
Contractor:
MARKMAN INC
9955 SE ASH STREET
PORTLAND, OR 97216 REQUIRED INSPECTIONS
Gas Line Insp
Phone: 503 - 255 -9923 Mechanical Insp
Reg #: LIC 00102857 Heating Unt Insp
Cooling Unt Insp
Duct Inspection
• S.D. Shut -down ORIGINAL
Misc. Inspection
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore.
Specialty Codes and all other applicable laws. All work will be done in accordance with approved
plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended
for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon
Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OA 652- 001 -0080.
You may obta copies of these rules or direct questions to OUNC by calling (503)24• • :9.
Issue By: j .V�� Permittee Signature: i/ 6
Call (503) 639 -4175 by 7:00 P.M. for inspections .ceded the next business day
Plan Check #7
CITY OF TIGARD Mechanical Permit Application Recd Bye
13125 S`W HALL BLVD. Commercial and Residential Date Recd7 Z - q1i
TIGARD, OR 97223 Date to P.E. 7 -2.9 9
(503) 639 -4171, x304 Date to DST I VA W
01 )_ . Print or Type . iguPi 99 c'3V Permit # net/f99 -CID3*
• I c omple e or ille • ' • le applications will not be accepted Called ° I - I - � ✓�i
Name of DevelopmenUProjeet Description
RE-1 III 17Y 30.I
Table 1A Mechanical Code Qty Price Amt
Job j- A Permit Fee 16.00
Street A )
Address -1 17 ' 6t.z) 0.1.40-1 2544R14 $r 1) including t ducts 8 vents U see footnote 1,2 9.65
Bldg# City/State Zip
2) Furnace 100,000 BTU+ //
i �� �� /p " / � c including ducts & vents see footnote 1,2 (0 12.00 17--
Name (or name of business) I 1 3) Floor Furnace
Owner it(t- frierhe.-- including vent see footnote 1,2 9.65
Mailing Address 4) Suspended heater, wall heater
4 , 7 � Spmbi - ,- i� or floor mounted heater see footnote 1,2 9.65
o / v J 5) Vent not included in appliance permit 4.75
City/State Zip Phone Check all that apply: 'Boiler Heat Air
�' /77A For Items 6 -10, see or Pump Cond Qty Price Amt
Name (or name of t( uslness) footnotes 1,2 Comp
. 6) <3HP;absorb unit to
100K BTU ii' 1, 9.65 Q°
Occupant Mailing Address 7) 3-15 HP;absorb unit
100k to 500k BTU 17.65
City /State Zip Phone 8) 15-30 HP; absorb
unit .5-1 mil BTU 24.15
Contractor Name 9) 30-50 HP; absorb
W A I N� 10) mil BTU 36.00
r _W 10 >50HP 50HP; absorb unit
Prior to permit e gg Address > >1.75 mil BTU 60.15
issuance, a copy ! / �S 5 - AS 4 11 11 Air handling unit to 10,000 C FM
of all licenses c' / to Zip Phone C [ 7.00
are required if C, 2(t / - r 12) Air handling unit 10,000 CFM+ 4L Q` -`
expired in COT Oregon Qns� . Board Llc.# Exp. Date I °
database I �i S5 7 2 -( -b 13) Non - portable evaporate cooler
Architect Name 7.00
Ti RPX1 6 CriL% _7 / 14) Vent fan connected to a single duct / - ��jjsp
or Mailing Address (� 4.75 oC0
7l 7a 0 1�a' S 15) Ventilation system not included in
�� appliance permit 7.00
�3 ineer
Engineer City /State Zip Phone
9 16) Hood served by mechanical exhaust
1 . > -- J / 7 &z 48 - 39 c • 7.00
Describe work to be done: � 17) Domestic incinerators
12.00
New* Repair 0 Replace with like kind: Yes O No 0 18) Commercial or industrial type incinerator
Residential 0 Commercial 0 48.25
19) Repair units
Additional information or description of work: 8.40
20) Wood stove /gas FP /other units /clothe dryer /etc.
7.00
NOTE: For Commercial projects only; Units over 400 lbs. require 21) Gas piping one to four outlets 11 ,,
structural gas calcs. See footnote 1 t 3.75
Type of fuel: oil 0 natural gas' LPG 0 electric 0 22) More than 4 -per outlet (each) `5" .75 a / 4 6 .
Minimum Minimum Permit Fee $50.00 SUBTOTAL 44. ? Se v.W f�
I hereby acknowledge that I have read this application, that the information 7% SURCHARGE • ' ' °, I Q I I 11
given is •• ect, that I am the owner or authorized agent of PLAN REVIEW 25% OF SUBTOTAL a t 4 ' x6 -44
the o that plans submitted are in compliance with Oregon State laws. Required for ALL commercial permits only Lk
TOTAL n 'e'k
Si . • if er gent Date ` t, fti,y i� 7�
7/ 2 �9 Other Inspections and Fees:
1 1 1. Inspections outside of normal business hours (mininum charge -two
Contact Person Name Phone hours) $50.00 per hour
‘..S`A Pi/V- - r°' .4 j 25S- Ti 73 2. Inspections for which no fee is specifically indicated (minimum
Il te v 'V charge -half hour) $50.00 per hour
Foonotes for commercial projects only: 3. Additional plan review required by changes, additions or revisions to
1. Provide full schematic of existing and proposed gas line and pressure. plans (minimum charge -one -half hour) $50.00 per hour
2. Provide drawings to scale showing existing and proposed mechanical
units. *State Contractor Boiler Certification required
"Residential A/C requires site plan showing placement of unit
I: urtechperm.doc rev 02/4/99
•
• 09/02/1999 08:31 503 - 443 -3700 TM RIPPEY CONSULTING PAGE 02
TYP. ROOF ASSEMBLY
(4) 3'0 SCREENED VENT
HOLES IN BLOCK BETWEEN
EVERY OTI -IER TRUSS
' 1..sII oTOTOTOTON
2x FASCIA ��' HOLD INSUL.
AWAT FROM
VENTS
�, +=4.
METAL GUTTER __ —_
2' CONTIN. SCREENED
VENT, TYP. —�
' PLYWD SOFFIT '+ AT NORTH WALL (GRIP A) '
PROVIDE (I) LAYER OF 5 1s .
TYPE 'X' GTP. BD. EA. FACE
TYP. WALL ASSEMBLY FOR I HOUR FIRE RATING
9 -2 -99
EAVE SEC.TIO
KC -17 SCALE: %. • I1_0.
5 44.1ae W. cam
G4,P
•
•
•
• Cr" ' 4 . 4 *
g t law -1"
• MOON
p 20;19 ��'
9,�PH TURHeAV.
•
fiol23.. I
..rM K TM RIPPEY .10L-.‘ Cm? 'F(C.S ��.,a4 - 6Y4J1 DATE R (Z(
11y1 CONSULTING EHGn�EERS ?nem iT ii- q{R - ma
CM BY Ml'F
7070 S.W. Fir Loop, Suite 100 •
•
Tigard, Oregon 97223 Joe no 4 ft? 2
Phone (503) 443 -3900 S - / of i
01/05/2000 • Activities for Case #: MEC1999 -00326
11:14:15 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 . Date 3 To Done By Disp. Level By Updated Notes •
' MECC090 (F) Issue permit 09/16/1999 BON DONE No Hold BON 09/16/1999
MECC075 (F) Reprint permit • 12/08/1999 GEO DONE No Hold GEO 12/08/1999
MECC011 Routed to Plans Examiner • 07/29/1999 DEB DONE . No Hold DEB 07/29/1999
MECC007 Application received 07/20/1999 BON DONE No Hold DEB 07/29/1999
MECC008 Permit created 07/29/1999 DEB DONE No Hold DEB 07/29/1999 •
MECC012 Plan Review Ltr. to Ofc. Svcs. 07/30/1999 RDP No Hold RDP 07/30/1999
MECC014 Plan checked /Approved by P.E. 09/02/1999 09/02/1999 09/02/1999 RDP DONE No Hold RDP 09/02/1999 .
MECC015 Reviewed Plans Routed to DSTS 09/02/1999 RDP DONE No Hold RDP 09/02/1999
MECC705 Gas Line Insp 09/02/1999 09/02/1999 11/24/1999 • TLP DONE No Hold TLP 11/24/1999
MECC706 Mechanical Insp 09/02/1999 09/02/1999 11/22/1999 MS PART No Hold MRS 11/22/1999 exhaust fans complete
supply and return partial
MECC715 Heating Unt Insp 01/03/2000 RB PASS No Hold RB 01/03/2000
MECC720 Cooling Unt Insp 01/03/2000 RB PASS No Hold RB 01/03/2000
MECC735 Duct Inspection 09/02/1999 09/02/1999 01/03/2000 RB PASS No Hold RB 01/03/2000
MECC016 DST Post- Review Completed 09/09/1999 BON DONE No Hold BON 09/09/1999
MECCO50 (F) Ready to issue 09/09/1999 BON DONE No Hold BON 09/09/1999
MECC799 Final Inspection 01/02/2000 01/02/2000 12/30/1999 RB FAIL No Hold AKJ 01/02/2000 installers need to be present to
perform the mech shut down of
equip
MECC799 Final Inspection 01/03/2000 01/03/2000 01/03/2000 RB PASS No Hold RB 01/03/2000 Label gas lines 2# GAS- to be
viewed at Building Final
BUP1999- 00449.
MECC800 Case Finaled 01/04/2000 AKJ DONE No Hold AKJ 01/04/2000
MECC799 Final Inspection 01/04/2000 01/04/2000 01/04/2000 RB PASS No Hold AKJ 01/04/2000
•
Page 1 of 1 •
-1UG 11 '99 12 :05PM INTERFACE ENGINEERS P. /7
6542 SE Lake Road
INTERFACE ENGINEERING Milwauke.OR97222
Consulting Engineers �j"\$ 503.659.6394 OFFICE
l ' 503.659.9029 FAX
AUG. Fax 1999
Fox Cover Sheet •
COiAM1 =y I t UUi 1ST. co,
COMPANY: Colamette Construction Company DATE: • . August I I , 1999
ATTENTION: Kevin Holmlund DESTINATION FAX NUMBER: 503 -625 -1945
FROM: Tracy Skinner
SUBJECT/PROJECT:
King City Office Building/Medak Building
PROJECT NO New X . .; MECHANICAL ELECTRICAL
The public water system supplying the project is capable of exceeding the minimum required fire flow. The fire flow in front
of the project site is calculated to be 5,870 g.p.m. at a residual pressure of 20 psig. Required fire flow is 1,750 at a residual
pressure of 20 psig.
A hydrant flow test in front of the project site was conducted on Wednesday, August I I , 1999 at 9:15 am. The hydrant
directly across from the site was flowed. Pressures were observed at the hydrant near SW Queen Elizabeth Street . Test
nozzle was a 4-12" "Hose Monster ". Test results were:
Static Pressure= 94psig •
Residual Pressure= 82psig
Total Corrected flow= 2198 g.p.m.
Pitot Pressure for Hose Monster = 44 psig (Flow from calibration chart= 2198 g.p.m.)
cc: Joe Martin - Tualatin Valley Fire & Rescue
Rich Sattler - City of Tigard
4<clil PR/1 '4p
;
curet ). f . . „
oRaoN
'ee 1 6, .00 4.
III O J. GE.S
E 6 /0/
Total Pages (Including Cover): 7
IF ALL PAGES ARE NOT RECEIVED, PLEASE CALL 503.659.6394 AS SOON AS POSSIBLE
H:W NGWA WPC)
CITY OF TIGARD BUILDING INSPECTION DIVISION
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 dr , BUP t99q - y Li
Date Requested I L i AM PM Bkp iqqq, by 3 V-I
Location ( l � 7 Q cA `u:22t? i to MEC 1`111 Z?;
Contact Person 0/0 Ph %dS qS i ! PLM
Contractor Ph SWR
(BUILDI Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT 61 •_%-
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Mi�
PART FAIL
ING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
CHANIC�
Post & eam
Rough In
Gas Line
Smoke Dampers
PART FAIL
TRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
T
- ckfill /Grading D b
S. itary Sewe
Sto Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catc Basi [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
Fire S • p Line
ADA
A••ro, i
� � wal. • • a b 1
oth 1 ►.t1,i Date ` Inspector Ext
- PART FAIL DO NOT REMOVE this inspection record from the job site.