Report Alder Geotechnical Services 3910 NE 10`" Avenue Portland, Oregon 97212 -1221 Phone 503.282.7482 Fax 503.282.7402 August 23, 2002 Project No. 364 -2 COPY Mr. Hap Watkins, Supervising Inspector City of Tigard Building Division 13125 SW Hall Boulevard Tigard, Oregon 97223 FINAL REPORT OF SPECIAL INSPECTIONS NEW PIN PILE RETAINING WALL BEHIND UNITS 62 -67 QUAIL HOLLOW WEST, 13021 SW RAPTOR PLACE TIGARD, OREGON Permit No. BUP2002 -00309 Dear Mr. Watkins: I have completed by observation of the subject retaining wall construction. The purpose of my site visits was to determine whether the wall construction was performed in general accordance with my approved plans dated June 19, 2002. This letter presents my opinion that the work was performed in substantial accordance with my design. The new steel pipe pile retaining wall was constructed behind Units 62 to 67. The wall was constructed using 21' long, 4 "- diameter Schedule 80 steel pipes driven into the ground at approximately 2' spacing. The height of the wall ranges from about 2' to 5'. The maximum height allowed by the design was 6'. The backs of the pipes were lined with Maccafferi zinc - coated, double twist 8x10 mesh and backed with zinc - coated 16 -gage mesh. The mesh was backfilled with 4" -minus crushed rock and covered with soil for landscape purposes. In my opinion, the wall was constructed in substantial accordance with my design. Please call me if you have questions. Sincerely, ALDER GEOTECHNICAL SER;" ,4, /01Am 1 • �-� 13507 `- A John N. Cunningham, P.E. Geotechnical Engineer 4, CUNO ex P. lZ - 3 1 . -0 3 (1) Addressee - (1) Mr. Manuel Castaneda Pro Landscape, Inc. (1) Mr. Ron Esty, Brownstone Homes, Inc.