Loading...
Permit R EVISE D CITY OF TIGARD 1 MEC HANICAL PERMIT 1111 C COMMUNITY DEVELOPMENT Permit #: MEC2011 -00563 T t G AR. D 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 06/11/2012 Parcel: 1S136DB00201 Jurisdiction: Tigard Site address: 11565 SW PACIFIC HWY Project: Fred Meyer Subdivision: 2000 -025 PARTITION PLAT Lot: 2 Project Description: Mechanical work associated with expansion and remodel 6/20/12, reprint to add (4) Type I hoods Contractor: SD DEACON CORP OF OREGON Owner: FRED MEYER INC 901 NE GLISAN ST SUITE 100 3800 SE 22ND AVE PORTLAND, OR 97232 PORTLAND, OR 97202 PHONE: 503 - 297 -8791 PHONE: 503 - 232 -8844 FAX: 503 - 297 -8997 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 06/11/2012 $21,725.95 Class of Work: ADD Type of Const: VB Plan Review 06/11/2012 $5,431.49 Occupancy Grp: M Occupancy Load: 12% State Surcharge - Mechanical 06/11/2012 $2,607.11 Stories: 1 Additional Plan Review 06/11/2012 $90.00 Project Valuation: $322,378.00 Fuel Air Handlers Fuel Types: Natural Gas Units < 10000 cfm: Gas Pressure: Units > 10000 cfm: Furnaces Boilers & Compressors Furnaces < 100K BTU: 0 -3 HP: Furnaces >= 100K BTU: 3 -15 HP: Floor Furnaces: 15 -30 HP: Unit Heaters: 5 30 -50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: 1 Heat Pump: Appliances Vent Fans: 15 Vent Systems: Total $29,854.55 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports (Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: 30 Other Desc: Duct Work: 100 Fire /Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0090. You may obtain a copy of the rules or direct C ^ orista OUNC b ailing 503.232.1987 or 1.800.332.2344. a. Issued B \ Permittee Signatur� \ Call 503.639.4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each Inspection. CITY OF TIGARD OFFICE COPY MECHANICAL PERMIT Permit #: MEC2011 -00563 COMMUNITY DEVELOPMENT TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 06/11/2012 Parcel: 1 S136DB00201 Jurisdiction: Tigard Site address: 11565 SW PACIFIC HWY Project: Fred Meyer Subdivision: 2000 -025 PARTITION PLAT Lot: 2 Project Description: Mechanical work associated with expansion and remodel Contractor: SD DEACON CORP OF OREGON Owner: FRED MEYER INC 901 NE GLISAN ST SUITE 100 3800 SE 22ND AVE PORTLAND, OR 97232 PORTLAND, OR 97202 PHONE: 503 - 297 -8791 PHONE: 503 - 232 -8844 FAX: 503 - 297 -8997 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 06/11/2012 9 /A277 $5" Class of Work: ADD Type of Const: VB Plan Review 06/11/2012 J1, $5,434-.-49 Occupancy Grp: M Occupancy Load: 12% State Surcharge - Mechanical 06/11/2012 if ora.33 $7,�TT 6-1 Stories: 1 Additional Plan Review 06/11/2012 � ro i c $90'Q Project Valuation: $322,378.00 Fuel Air Handlers ,4 Z 4 7 E2 72t CZ Fuel Types: Natural Gas Units < 10000 cfm: /=d,L. 4E7�Gc Gas Pressure: Units > 10000 cfm: J/h et en/ . Furnaces Boilers & Compressors • Furnaces < 100K BTU: 0 -3 HP: Furnaces >= 100K BTU: 3 -15 HP: Floor Furnaces: 15 -30 HP: Unit Heaters: 5 30 -50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: 1 Heat Pump: q/ Appliances Vent Fans: 15 Vent Systems: Total Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports (Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: 30 Other Desc: Duct Work: 100 Fire /Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 -001 -0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: / "N. A - Permittee Signature: OA/ /0L, / e.ey- -/ /UA/ Call 503.639.4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept In a conspicuous place on the Job site until completion of the project. Approved plans are required on the Job site at the time of each inspection. Mechanical Permit Aptilication RE') cEg r �-1 � FOR O USE FFICE ONL Y s W +-e� Received City of Tigard Date/B : (;/7 4 10. permitl,o. // n 13125 SW Hall Blvd. Tigard, OR 97223 Plan Res Review Phone: 503.718.2439 Fax: 503.598.1960, JUN 07 2012 Date/By: Other Permit, TIGARD Inspection Line: 503.639.4175 Date Ready/By: tats I Id See Page 2for Internet: www.tigard- or.gov pp CITY OFTIGARD Notified/Method: r l / � �I I Supplementallnfonnation BUILDING DIVISION TYPE OF WORK COMMERCIAL FEE' SCHEDULE — USE CHECKLIST Mechanical permit fees* are based on the value of the work ❑ New construction la Add ti on/alteration/replacement performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition ❑ Other: mechanical materials, equipment, labor, overhead, and profit , value: 3a. 312 CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT / SYSTEMS FEES' ❑ 1- and2- family dwelling ® Commercial /industrial ❑ Accessory building For special ir{fort:w oausechecklst ❑ Multi- family ❑ Master builder ❑ Other. Description I Qty. I Ea. I Total JOB SITE INFORMATION AND LOCATION Heating/cooling Air conditioning Job site address: 11565 SW Pacific Highway (requires site plan showing placement) 46.75 City/State/ZlP: Tigard, OR, 97223 Furnace 100,000 BTU (ducts/vents) 46.75 Furnace 100,000+. BTU (ducts/vents) 54.91 Suite/bldg./apt. no.: I Project name: FM #375 Tigard Heat pump • (requires ate plan showingplacement) 61.06 Cross street/directions to job site: .SW 71' Ave Duct work 23.32 Hydronic hot water system 23.32 Residential boiler (radiator or hydronic) 23.32 Unit heaters (fuel -type, not electiic), Add New Unit Heaters, Add New Fan Coil Units and Condensing Units. in -wall, in -duct, suspended, etc 46.75 Subdivision: I Lot no.: Flue/vent for any of above 23.32 Other: _ 23.32 _ Tax map/parcel no.: 11S136DB, Tax Lot 201 Other fuel appliances: DESCRIPTION OF WORK Water heater 23.32 Gas fireplace 33.39 Demo and Replace eleven Rooftop Units; Add three Rooftop Units, Demo fifteen Flue vent for water heater or gas Enitaust fans, Replace and Add New Exhaust fans. Demo and Replace Kitchen hoods, fireplace 23.32 Log lighter (gas) 23.32 Add New Unit Heaters, Add New, Fan Coil Units and Condensing Units. 'Wood /pellet stove , 33.39 Wood fireplace/insert 23.32 ® PROPERTY OWNER I ❑ TENANT Chimney /lined lue/velt 23:32 Other: 23.32 _ Name: Fred Meyer Stores Environmental exhaust and-ventilation: Address: 3800 SE 22nd Ave Range hoodlotherkitchet equipment, . 33.39 City/State/ZIP: Portland, OR, 97202 Clothes dryer exhaust •33.39 Single -duct exhaust (bathrooms, Phone: (503)232 -8844 Fax:.(503)797 -3509 toilet compartments, utility rooms) 23.32 ' ❑ APPLICANT - ® CONTACT PERSON Attidcrawlspace fans 23:32 • Business name: Mulvauty,G2 Architecture Other: 23.32 Fuel plptnz Contact name: Amy Sdteclda -Cox $14.15 for first four; $4.03 for each a_ dditional Address: 601 SW Second Ave Furnace, do. Gas heat pump City/State/ZIP: Portland Or, 97202 Wall /suspended/unit heater Phone: (971) 998 -1443 I Fax:: (503) 223 -8331 . Water heater Fireplace E- mail: ,anysdhedda -cox@ tulvannyg2.com Range . . CONTRACTOR - 'Barbecue Business name:- SD Deacon Clothes dryer (gas) Other: •Address: 901 NE Glisan Street, Suite 100 MECHANICAL PERMIT FEES' City/State/ZZIP::.Portlatd, OR 97232-, Subtotal Min imumpermit fee ($90.00) Phone: (503) 297 -3791 I Fax: (503) 297 -8997 Plan review (25% of permit fee) CCB lic.: ro lea a, eP . State surcharge (12%.o£ permit fee) �/ TOTAL PERMIT FEE Authonzedsi natur i��� " This permit application (spires 'lap omit is not obtained within ISO g days after It hasbeui accepted as complote. I -Print name: William Mercer I Date: 6/5/12 I • Fee methodology set by Tri- County Building industry Service Board LIBuCdnglPennuslMEC- Pe rmitAppdoc 09)09/10 440- 4617r,(1.1N21COM/WEB) FOR OFFICE USE ONLY — SITE ADDRESS: //6 SA) R9 e /`l C jcJJ This form is recognized by most building departments in the Tri -County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT Transmittal Letter T I G R n. 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard- or.gov TO: DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED ED MAY 31 2012 FROM: Dustin Clauser CITY OFTIGARD COMPANY: S.D. Deacon Corps. of Oregon BUILDING DIVISION PHONE: 503 -504 -5957 B 411 RE: 11565 SW Pacific Hwy MEC201100563 (Site Address) (Permit Number) FM -375 (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: Additional set(s) of plans. Revisions: 2 Cross section(s) and details. Wall bracing and/or lateral analysis. Floor /roof framing. Basement and retaining walls. 2 Beam calculations. Engineer's calculations. Other (explain): REMARKS: RTU Curb Seismic Restraint Calculations FOR OFFICE USE ONLY Routed to Permit hnician: Date: 6 3 1 ( ( P2._- Initials: Fees Due: es ❑ No Fee Description: Amount Due: 1 A r 0 $ .00 $ $ $ Special Instructions: Reprint Permit (per PE): ❑ Yes ❑ No ' ❑ Done Applicant Notified: Date: Initials: • 1:\ Building\Forms \TransmittalLetter- Revisions.doc 05/25/2012 - ii PO— ge /ri Mechanical Permit Applicat' FOR OFFICE USE ONLY �'/ Received City of Tigard DECEIVED Date/By:. / & // / Pe rmit No.: MEc ^ / /�O �j - II ° 13125 SW Hall Blvd., Tigard, OR 97223 Plan Review 4 (/KJ �� ✓ Phone: 503.718.2439 Fax: 503.598.1960D E C 2 2011 Date/By: 411.# I 3\2. ,1`J er Permin? -74 a0 // OM /3 Inspection Line: 503.639.4175 Date Read /B t� ris: TIGARD Ready /By. la See Page 2 for Internet: www.tigard or.gov CITY OF TIGARD Notified/Method: SW Supplemental Information i IJ • • 11 ; _ a _ _ • t.. " W flL && _ K TYPE OF r IRK COMMERCIAL FEE* SCHEDULE - USE CHECKLIST Mechanical permit fees' are based on the value of the work ❑ New construction ® Addition /alteration/replacement performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition ❑ Other: mechanical materials, equipment, labor, overhead, and profit. Value: $ 754,638 CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT / SYSTEMS FEES* ❑ 1- and 2- family dwelling ® Commercial /industrial ❑ Accessory building For special information use checklist. ❑ Multi- family ❑ Master builder ❑ Other: Description I Qty. I Ea. I Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning Job site address: 11565 SW Pacific Highway (requires site plan showing placement) 46.75 Furnace 100,000 BTU (ducts/vents) 46.75 City /State /ZIP: Tigard, OR, 97223 Furnace 100,000+ BTU (ducts/vents) 54.91 Suite/bldg. /apt. no.: I Project name: FM #375 Tigard / 504 - A nr - E� Heat pump � — (requires site plan showing placement) 61.06 Cross street/directions to job site: SW 71" Ave T.r Duct work 23.32 Hydronic hot water system 23.32 Residential boiler (radiator or hydronic) 23.32 Unit heaters (fuel -type, not electric), Add New Unit Heaters, Add New Fan Coil Units and Condensing Units. in -wall, in -duct, suspended, etc. 46.75 Subdivision: I Lot no.: Flue /vent for any of above 23.32 Other: 23.32 Tax map /parcel no.: 1S136DB, Tax Lot 201 Other fuel appliances: • DESCRIPTION OF WORK Water heater 23.32 Demo and Replace eleven Rooftop Units, Add three new Rooftop Units, Demo fifteen Gas fireplace 33.39 Flue vent for water heater or gas Exhaust fans, Replace and Add New Exhaust fans. Demo and Replace Kitchen hoods, fireplace 23.32 Log lighter (gas) 23.32 . Add New Unit Heaters, Add New Fan Coil Units and Condensing Units. Wood/pellet stove 33.39 Wood fireplace /insert 23.32 ® PROPERTY OWNER I ❑ TENANT Chimney/liner /flue /vent 23.32 Other: 23.32 Name: Fred Meyer Stores Environmental exhaust and ventilation: Address: 3800 SE 22nd Ave Range hood/other kitchen equipment 33.39 City /State /ZIP: Portland, OR, 97202 Clothes dryer exhaust 33.39 Fax: 503 797 -3509 Single -duct exhaust (bathrooms, Phone: (503)232-8844 ( ) toilet compartments, utility rooms) 23.32 ❑ APPLICANT ® CONTACT PERSON Attic /crawlspace fans 23.32 Business name: Mulvanny G2 Architecture Other: 23.32 Fuel piping: Contact name: Amy Scheckla -Cox S14.15 for first four; 54.03 for each additional Address: 601 SW Second Ave Furnace, etc. Gas heat pump City /State /ZIP: Portland Or, 97202 Wall /suspended/unit heater Phone: (971) 998 -1443 Fax: : (503) 223 -8381 Water heater Fireplace E -mail: amy.scheckla- cox @mulvannyg2.com Range CONTRACTOR Barbecue Business name: i)f, N f AF / C / J� Clothes dryer (gas) I I t/ Other: Address: '730 (0 tJ 3 ? =` 0I- MECHANICAL PERMIT FEES* Cit /State /ZIP: J � p,�. nn //'' ,, Subtotal y �� D �M. y �IJU� wg � Minimum permit fee ($90.00) Phone: ) O -+39 Fax: ( ) 3a4. -g5--b(' Plan review (25% of permit fee) CCB lic.: /6,5 7 State surcharge (12 %ofpermit fee) a " TOTAL PERMIT FEE Authorized signature: 4------- This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: 4.l.w• ■•• 1 1/4l • 6 - 1 AgL Date: I 1 - 3 J - `) • Fee methodology set by Tri- County Building Industry Service Board 1: \Building \Permits \MEC- PermitApp,doc 09/09/10 440 -4617T (11 /02/COM/WEB) FOR OFFICE USE ONLY — SITE ADDRESS: 1/56 & Pict &cer This form is recognized by most building departments in the Tri- County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT 1 2 Transmittal Letter FlG A -Ft n 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard- or.gov TO: Mark VanDomelen DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED JUN 20 2012 FROM: Dustin Clauser CITY OF TIGARD COMPANY: S.D. Deacon Corp. of Oregon BUILDING DIVISIO PHONE: 503 -504 -5957 RE: 11565 SW Pacific Hwy MEC2011 -00563 (Site Address) (Permit Number) Fred Meyer #375 (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: I Description: Copies: Description: 2 Additional set(s) of plans. Revisions: Cross section(s) and details. Wall bracing and/or lateral analysis. Floor /roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other (explain): REMARKS: Commerical Kitchen Hood Mechanical Review FOR 1OFFIFE USE ONLY -: to Pe it a 'cian: Date: 6/21 I Z Initials ees Due: es ❑ No Fee Description: Special Instructions: Reprint Permit (per PE): Yes ❑ No El Do Applicant Notified: • .V644 __,A b. Q , Initials I:\Building\ Forms \TransmittalLetter - Revisions.doc 05/25/2012 • • • . -. • Mechanical Permit Application - City of Tigard Page 2- Supplemental Information 'Commercial & Multi-Family Fee Schedule: Total Valuation: Permit Fee: $0.00 to $500.00 ' Minimum fee $69.06 • - $500.01 to $5000.00 $69.06 for the first $500.00 and - $3.07.for each additional $100.00 or fraction thereof, to and including $5,000.00. $5;000.01 to $10,000.00 $207.21 for the first $5,000.00 and $181 for each additional $100.00 or fraction thereof, to and including ' - $10,000.00. $10,000.01 to $50,000.00 $347.71 for the first $10,000.00 and $2.54 for each addition $100.00 or fraction there; to and including ' — $50,000.00. • -$50,000.01 to $loo,coo.00 $1,363:71 for the first $50,000.00 and ' . $149, for each additional $100 or = = fraction thereof, to and including . • ' .= $100,000.00: • $100,000.01 and tip, $2,608.71 'for the first $100,000.00 and •. $2.92 foreacti 'additional $100.00 or fraction thereof. • • , . , . Note: All new COmmercial,bnildings require 2 sets of plans. • _ • • • c , 1:\BuildingWermits\MEC-PennitAmidoc 09/09/10 2 05/0312012 15:43 Grey Wolf (FA)03603262506 P.0011004 Grey Welt II4VAC INC. 7306 NE 37"' Ave, Vancouver, WA 98665 E - mail: nancyw@greywolfhvac.com Office: 360 -635 -6117 Fax: 360- 326 -8506 rt°111 c Fax - 76'q To: City of Tigard Bldg. Dept. Attn: Debbie From: Nancy Wilde, Office Manager Fa= 503 - 598-1960 Pages: 4 pages including cover Phone: Date: 5/3/2012 Re: Permit Application CC: • ❑ Urgent ❑ For Review ❑ Please Comment 0 Please Reply O Please Recycle • Comments • 05/03/2012 15:44 Grey Wolf TAX) .1603268506 D En �00 0 • j� Gl, �J J!J MAY -3 2012 Pymt Aut : CITY OF TIGARD Standard Form Subcontract Agreement BUILDING DIVISION Subcontract #: 17503 Code #: 4184- 15500.S • • THIS AGREEMENT, made this April 10, 2012, by and between Grey Wolf HVAC Inc., hereinafter called "Subcontractor ", and S.D. Deacon Corp. of Oregon, hereinafter called "Contractor", who state and agree as follows: Subcontractor agrees to perform all work set forth herein in the construction of Fred Meyer - Tigard for Fred Meyer Stores, Inc and Ohio Corporation hereinaftercalled "Owner", at 11565 SW Pacific Hwy, Tigard, OR 97223 in accordance with the terms and provisions of this Subcontract, the contract between Owner and Contractor, dated March 22, 2012 including all the General and Special Conditions, Drawings and Specifications and other Documents, including those listed on Exhibit D, forming, or by reference made a part of the General Contract all of which shall be herein referred to as the "Contract Documents" and which are incorporated into this • Subcontract by reference, and Subcontractor agrees to be bound to Contractor and Owner by the terms and provisions thereof. It is agreed that the materials to be furnished and/or work to be done by Subcontractor is generally described on the enclosed ExhibitA and includes all work necessary or incidental thereto, hereinafter called the "Work". It is agreed that Contractor shall pay Subcontractor the sum of One Hundred Seve Nin Thousand ht Hundred Ninety Eisrht and 00 /100 Dollars ($179,898.001 for the full, complete and prompt performance of the Work contemplated hereby and in full compliance with the Contract Documents as well as the attached Exhibits. The Exhibits listed below are incorporated by this reference as though fully set forth herein. Exhibit "A" Scope Exhibit "B" Standard Form Subcontract Agreement Terms and Conditions (OR 0895) Exhibit "C" Insurance Requirements • Exhibit "D" List of Documents . Exhibit "E" Subcontractor Safety Requirements Exhibit "F" Indemnification Addendum Exhibit "G" Subcontractor's Disclosure Consent All of the documents listed are made a part of this Subcontract, and Subcontractor is responsible for their contents whether or not it has received or reviewed a copy of each document. All documents listed are available at Contractors office for review and copies of documents are available upon written request. CONTRACTORS ARE REQUIRED BY LAW TO BE LICENSED AND REGULATED BY THE CONTRACTOR'S STATE LICENSE BOARD. ANY QUESTIONS CONCERNING A CONTRACTOR MAY BE REFERRED TO THE REGISTRAR, TELEPHONE NUMBER (503) 378 -4621. IN WITNESS WHEREOF, the parties hereto have executed this Subcontract Agreement by their proper officers or duly authorized agents. S.D. Deacon Corp. of Oregon Grey Wolf•HVAC Inc. • By: By u �w�c Bradford . Howe, Executive Vice Pres' enk Name/Title Ukto �3 • Address: 901 NE Glisan Street, Suite 10L Address: 7306 NE 37th Avenue Portland, OR 97232 Vancouver, WA 98665 Phone: 503 - 297-8791 • Phone: 360 -588 -3207