Permit CITY OF TIGARD
i� ,.�i r .,. \ DEVELOPMENT SERVICES BUILDING PERMIT
I PERMIT # • BUP96 -0599
�� 11 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639.4171 DATE ISSUED: 12/26/96
PARCEL: 1S136CC —CHOO1
SITE ADDRESS...: 08376 SW PFAFFLE ST
SUBDIVISION • CARRIAGE HOUSE APARTMENTS ZONING:R -12
BLOCK • LOT •
REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION —
CLASS OF WORK.:ACS FIRST • 1556 sf N: S: E: W:
TYPE OF USE...:MF SECOND...: 0 sf PROTECT OPENINGS?
TYPE OF CONST.:5N 1556 ...: 0 sf N: S: E: W:
OCCUPANCY GRP.:.R1' 1 J TDTAL 1556 sf ROOF CONST: FIRE RET ?:
OCCUPANCY LOAD: 77 0 BASEMENT.: 0 sf AREA SEP. RATED:
STOR.: 1 HT: 0 ft GARAGE...: 0 sf OCCU SEP. RATED:
BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED
FLOOR LOAD • 0 psf LEFT: 0 ft RGHT: 0 ft FIR SPKL: SMOK DET..:Y
DWELLING UNITS: 0 FRNT: 0 ft REAR: 0 ft FIR ALRM: HNDICP ACC:
BEDRMS: 0 BATHS: 0 IMP SURFACE: 0 PRO CORR: PARKING: 0
V ALUE. $ : 129786
Remarks: Recreation room for Carriage House apartments and swimming pool
Owner: FEES - - --
ANDREWS MANAGEMENT, LTD type amount by date recpt
4000 SW KRUSE WAY #270 PLCK $ 330.20 B 07/24/96 96- 282082
FIRE $ 203.20 B 07/24/96 96- 282082
LAKE OSWEGO OR 97035 PRMT $ 508.00 B 12/23/96 96- 288066
Phone #: 699 -8645 5PCT $ 25.40 B 12/23/96 96- 28806E
EROS $ 80.00 B 12/23/96 96- 288066
Contractor: ERPC $ 26.00 B 12/23/96 96- 288066
MCH CONSTRUCTION CO ERPC $ 26.00 B 12/23/96 96- 288066
COLUMBIA EQUITIES INC
8235 SW OLESON RD STE C
PORTLAND OR 97223
Phone #: 224 -7410 $ 1198.80 TOTAL
Reg #..: 049267
REQUIRED INSPECTIONS
This permit is issued subject to the regulations contained in the Footing Insp
Tigard Municipal Code, State of Ore. Specialty Codes and all other Foundation Insp
applicable laws. All work will be done in accordance with Post /Beam Insp
approved plans. This permit will expire if work is not started Slab Ins p
within 180 days of issuance, or if work is suspended for more Framing Insp
than 180 days. Fireplace Insp
Insulation Insp
Shear Wall Insp
Firewall Insp
Permittee S ■ - - U10" 1i .. Gyp Board Insp
41111111■-�,� Appr /Sdwlk Insp
Issued B o �>T Final Inspection
i .
Call for inspection — 639 -4175
_
. l . Pr
Commercial Building Permit Application
City of Tigard
13125 SW Hall Blvd. r % X 1 !' S"'C
L
Tigard, OR 97223 )
(503) 639 -4171
SW PFAFFLE & 83RD
WCTM 1S1 36CC f f
Jobsite Address: TAX LOTS 200, 300, 2000-PL--43,1/0 ' L Ej ( € - a 7 (o
S� P�U�Ie Office Use Only . :�
Tenant: ('n�sV v y }kOcc�o.4e Suite # G.
Valuation: /° 7 .FNc[un�a pot,/ e7 *tt,
ermit # l� f 1 I r .. "
Owner: ANDREWS MANAGEMENT LTD 1 �
Map & TL # V 3(v CC - ' eft OO�
Address: 4000 KRUSE WAY PLACE BLDG 1 #270
Approvals Required '
LAKE OSWEGO OR 97035
Planning.'
Phone: (503) 699 -8645
Engineering .
Other - 1"
MCH CONSTRUCTION
Contractor: t�V : n 4,
���:�: 77,r- ;cry
Address: 8235 SW OLESON RD STE C
PORTLAND OR 97223 Type of const: ' Ki O (r ' //
Phone: (503) 244 -0523
Occupancy class: 1 9
Contractor's License #
49267 Sprinklered? Yes
(attach copy of current Oregon license) Sq. ft. of project: (6
Contact name & phone: Phil McHugh (503) 244 -0523 Story (1st, 2nd, etc.)
Architect/Engineer: P. Rowell /R. G. Naff
Proposed use: ae ec�7 R
Address: 18641 SW Benfield Avenue
Previous use: Si su FA-m/ < a~
Lake Oswego, OR 97035 Note: Plum :ing & mechanical plans
must be submitted at time of
Phone:
(503) 639 -8045 building permit application.
JOB DESCRIPTION: Co", 9 T. sc Vice. 13
I), L — os g3
Applicant m Signa ure & Phone nu er
Received by: Date Received:
Permit # Account Description Amount Amt. Pd. Bal. Due
M61- 110 -d7Ag Bldg. Permit (BUILD) ■S , vU
Plumb. Permit (PLUMB)
Mech. Permit (MECH)
State Tax (TAX) Zg ( 40 2 . Lib
Bldg:
Plumb: . .
Mech:
Plan Check (PLANCK) 2 j 3b .za 3 ; _0
Bldg: 2 119:?.0
Plumb:
Mech:
Sewer Connection (SWUSA)
Sewer Inspection (SWINSP)
Parks Dev Charge (PKSDC)
Residential TIF (TIF -R)
Mass Transit TIF (TIF -MT)
Commercial TIF (TIF -C)
Industrial TIF (TIF-1)
Institutional TIF (TIF -IS)
Office TIF (TIF -0)
Water Quality (WQUAL)
Water Quantity (WQUANT)
Fire Life Safety (FLS) c-O.3' .3v ,x,03 24 -
Erosion Cntrl Permit (ERPRMT) $1) qfp
Erosion Planck/USA (ERPLAN) . �p
Erosion Planck/COT (EROSN) 24 _k
TOTALS: 174.0 533 ft GW L I P
V'1�
Page No. 1 CASE HISTORY FOR CASE NO.: BUP96 -0599
ANDREWS MANAGEMENT, LTD
08376 SW PFAFFLE ST
04/25/98
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
BUPA670 Mechanical Inop / / / / 04/10/97 above ceiling- ok PART RB 04/10/97 RB
appliances (boilers, hot -water heater,
A/C unit) not installed yet;
BUPB007 Application received / / / / 07/22/96 RECD JH 11/26/96 BON
BUPB008 Permit created / / / / 07/30/96 PEND B 11/26/96 BON
BUPB015 Routed to Plana Examiner / / / / 07/30/96 PEND B 11/26/96 BON
BUPB025 Reviewed Plans Routed to DSTe / / / / 11/21/96 APPR JHF 11/26/96 BON
BUPB028 DST Post- Review Completed / / / / 11/26/96 PASS B 11/26/96 BON
BUPB090 (F) Ready to issue / / / / 11/26/96 PASS B 11/26/96 BON
BUPB705 Footing Inep / / / / 01/09/97 accepted compaction report PASS RB 01/09/97 RB
BUPB706 Foundation Inep / / / / 01/13/97 PASS RB 01/13/97 RB
BUPB715 Slab Insp / / / / 01/31/97 PASS RB 02/03/97 RB
BUPB730 Framing Inep / / / / 04/08/97 shear req'mt; strap plate -to -beam at FAIL RB 04/08/97 RB
main entry; tempered glazing req'mt;
strap interior wall- marked; support
• framing at access; support ceiling joist
at rear bathrm; H -clips missing; nail
plate protection; hanger needs
additional nailing at weight room;
BUPB730 Framing Insp / / / / 04/10/97 pending- nail truss hanger PASS RB 04/10/97 RB
mech appliances to be checked at
final (above ceiling ok)
BUPB745 Insulation Inep / / / / 04/10/97 pending- chink windows /doors where PASS RB 04/10/97 RB
lacking; pack lids of both sides of the
window unite voids at fwd room; those
areas that are hard to reach need to be
insulated- check at final for coverage;
mach & temp glazing req'mta to be
checked at final;
BUPB750 Shear Wall Insp / / / / 04/08/97 PEND RB 04/10/97 RB
pending- secure HD's where marked
BUPB750 Shear Wall Inep / / / / 04/10/97 PASS RB 04/10/97 RB
BUPB755 Firewall Inep / / / / 04/16/97 pending - add nailing to 4" ctrl along PASS RB 04/17/97 RB
perimeters.
BUPB760 Gyp Board Inep / / / / 04/16/97 PASS RB 04/17/97 RB
Page No. 2 CASE HISTORY FOR CASE NO.: BUP96 -0599
ANDREWS MANAGEMENT, LTD
08376 SW PFAFFLE ST
04/25/98
•
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
-- -- --- -------- ---
BUPB799 Final Inspection / / / / 08/08/97 boiler venting B -vent clearance 1 "- w/ FAIL RB 08/08/97 RB
collar
venting above roof 2' -10'
down spout missing at rear S. corner
• pool fencing temporary
BUPB799 Final Inspection / / / / 02/02/98 PASS RB 02/02/98 RB
BUPC100 (F) Issue permit / / / / 12/26/96 PASS JSD 12/26/96 CTR
BUPC705 Foot /Found Insp 07/21/97 / / 07/15/97 Pool: electrical approved 070997/BRP, PART RB 07/21/97 J *H
plumbing approval required before
foundation can be Advised
contractor.
Spa: electrical approved 070997/BRP,
plumbing approval required before
foundation can be approved. Maintain
clearance from rebar to earth contact
(as on plans).
BUPC727 Masonry Inap 07/21/97 / / / / gunite 02/02/98 RB
NOT PART OF BUILDING INSPECTION!
BUPD400 Development conditions met / / / / 03/06/98 PASS JDA 03/06/98 JDA
BUPD950 (F) Issue Cert. of Occupancy / / / / 02/02/98 rb signed /3/19/98 to david 03/19/98 JT
•
0 70 -/
f
CITY OF TIGARD BUILDING INSPECTION DIVISION
24 -Hour Inspection Line: 639 -4175 Business Phone: 639 - 4171 q /
Date Requested: - r '� — V A.M. P.M. MST':
Location: ! 6. J PI S E i / l / / . au— '' 4 :c.' 0 -03*
Tenant: c -/2!A 6 i Suite: Bldg: MEC: • 0 I (a
Contractor: � (it/ ? Phone: Q--5. / Q -9,9 d 3 PLM:
Owner: Phone: ELC:
,/ ` 1 / Qynd . 'la %6 f,(/nol. ELR:
BUILDING B con PLUMBING ELEC ' AL SITE
Site o Post/Beam ea
Cover /Service Sewer /Storm
Footing Roof UndFUSlab Rough -In Ceiling Water Line
Slab Framing Top Out Gas Line Rough -In UG Sprinkler
Foundation Insulation Sewer Hood/Duct Reconnect Vault
Bsmt Damp Drywall Storm Furnace Temp Service MISC.
Masonry Ceiling Rain Drain A/C UG Slab
Shear /Sheath Fire Spklr Crawl/Found Dr Heat Pum Low Volt
• 'pro Approved ` Approved Approved
Appr /Sdwlk _ .0 • • 6 oved Not Approved t- L ed . Not Approved Not Approved
` FIN • - FINAL FINAL FINAL
•
)----\
r
i
C
,
'lb _...../'
O Call for reinspection O Reinspection fee of $ required before ne tion O Unable to inspect
Q 'f
Inspector: $ Date: 2 6 / a Page of
l