Loading...
Permit CITY OF TIGARD i� ,.�i r .,. \ DEVELOPMENT SERVICES BUILDING PERMIT I PERMIT # • BUP96 -0599 �� 11 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639.4171 DATE ISSUED: 12/26/96 PARCEL: 1S136CC —CHOO1 SITE ADDRESS...: 08376 SW PFAFFLE ST SUBDIVISION • CARRIAGE HOUSE APARTMENTS ZONING:R -12 BLOCK • LOT • REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION — CLASS OF WORK.:ACS FIRST • 1556 sf N: S: E: W: TYPE OF USE...:MF SECOND...: 0 sf PROTECT OPENINGS? TYPE OF CONST.:5N 1556 ...: 0 sf N: S: E: W: OCCUPANCY GRP.:.R1' 1 J TDTAL 1556 sf ROOF CONST: FIRE RET ?: OCCUPANCY LOAD: 77 0 BASEMENT.: 0 sf AREA SEP. RATED: STOR.: 1 HT: 0 ft GARAGE...: 0 sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD • 0 psf LEFT: 0 ft RGHT: 0 ft FIR SPKL: SMOK DET..:Y DWELLING UNITS: 0 FRNT: 0 ft REAR: 0 ft FIR ALRM: HNDICP ACC: BEDRMS: 0 BATHS: 0 IMP SURFACE: 0 PRO CORR: PARKING: 0 V ALUE. $ : 129786 Remarks: Recreation room for Carriage House apartments and swimming pool Owner: FEES - - -- ANDREWS MANAGEMENT, LTD type amount by date recpt 4000 SW KRUSE WAY #270 PLCK $ 330.20 B 07/24/96 96- 282082 FIRE $ 203.20 B 07/24/96 96- 282082 LAKE OSWEGO OR 97035 PRMT $ 508.00 B 12/23/96 96- 288066 Phone #: 699 -8645 5PCT $ 25.40 B 12/23/96 96- 28806E EROS $ 80.00 B 12/23/96 96- 288066 Contractor: ERPC $ 26.00 B 12/23/96 96- 288066 MCH CONSTRUCTION CO ERPC $ 26.00 B 12/23/96 96- 288066 COLUMBIA EQUITIES INC 8235 SW OLESON RD STE C PORTLAND OR 97223 Phone #: 224 -7410 $ 1198.80 TOTAL Reg #..: 049267 REQUIRED INSPECTIONS This permit is issued subject to the regulations contained in the Footing Insp Tigard Municipal Code, State of Ore. Specialty Codes and all other Foundation Insp applicable laws. All work will be done in accordance with Post /Beam Insp approved plans. This permit will expire if work is not started Slab Ins p within 180 days of issuance, or if work is suspended for more Framing Insp than 180 days. Fireplace Insp Insulation Insp Shear Wall Insp Firewall Insp Permittee S ■ - - U10" 1i .. Gyp Board Insp 41111111■-�,� Appr /Sdwlk Insp Issued B o �>T Final Inspection i . Call for inspection — 639 -4175 _ . l . Pr Commercial Building Permit Application City of Tigard 13125 SW Hall Blvd. r % X 1 !' S"'C L Tigard, OR 97223 ) (503) 639 -4171 SW PFAFFLE & 83RD WCTM 1S1 36CC f f Jobsite Address: TAX LOTS 200, 300, 2000-PL--43,1/0 ' L Ej ( € - a 7 (o S� P�U�Ie Office Use Only . :� Tenant: ('n�sV v y }kOcc�o.4e Suite # G. Valuation: /° 7 .FNc[un�a pot,/ e7 *tt, ermit # l� f 1 I r .. " Owner: ANDREWS MANAGEMENT LTD 1 � Map & TL # V 3(v CC - ' eft OO� Address: 4000 KRUSE WAY PLACE BLDG 1 #270 Approvals Required ' LAKE OSWEGO OR 97035 Planning.' Phone: (503) 699 -8645 Engineering . Other - 1" MCH CONSTRUCTION Contractor: t�V : n 4, ���:�: 77,r- ;cry Address: 8235 SW OLESON RD STE C PORTLAND OR 97223 Type of const: ' Ki O (r ' // Phone: (503) 244 -0523 Occupancy class: 1 9 Contractor's License # 49267 Sprinklered? Yes (attach copy of current Oregon license) Sq. ft. of project: (6 Contact name & phone: Phil McHugh (503) 244 -0523 Story (1st, 2nd, etc.) Architect/Engineer: P. Rowell /R. G. Naff Proposed use: ae ec�7 R Address: 18641 SW Benfield Avenue Previous use: Si su FA-m/ < a~ Lake Oswego, OR 97035 Note: Plum :ing & mechanical plans must be submitted at time of Phone: (503) 639 -8045 building permit application. JOB DESCRIPTION: Co", 9 T. sc Vice. 13 I), L — os g3 Applicant m Signa ure & Phone nu er Received by: Date Received: Permit # Account Description Amount Amt. Pd. Bal. Due M61- 110 -d7Ag Bldg. Permit (BUILD) ■S , vU Plumb. Permit (PLUMB) Mech. Permit (MECH) State Tax (TAX) Zg ( 40 2 . Lib Bldg: Plumb: . . Mech: Plan Check (PLANCK) 2 j 3b .za 3 ; _0 Bldg: 2 119:?.0 Plumb: Mech: Sewer Connection (SWUSA) Sewer Inspection (SWINSP) Parks Dev Charge (PKSDC) Residential TIF (TIF -R) Mass Transit TIF (TIF -MT) Commercial TIF (TIF -C) Industrial TIF (TIF-1) Institutional TIF (TIF -IS) Office TIF (TIF -0) Water Quality (WQUAL) Water Quantity (WQUANT) Fire Life Safety (FLS) c-O.3' .3v ,x,03 24 - Erosion Cntrl Permit (ERPRMT) $1) qfp Erosion Planck/USA (ERPLAN) . �p Erosion Planck/COT (EROSN) 24 _k TOTALS: 174.0 533 ft GW L I P V'1� Page No. 1 CASE HISTORY FOR CASE NO.: BUP96 -0599 ANDREWS MANAGEMENT, LTD 08376 SW PFAFFLE ST 04/25/98 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By BUPA670 Mechanical Inop / / / / 04/10/97 above ceiling- ok PART RB 04/10/97 RB appliances (boilers, hot -water heater, A/C unit) not installed yet; BUPB007 Application received / / / / 07/22/96 RECD JH 11/26/96 BON BUPB008 Permit created / / / / 07/30/96 PEND B 11/26/96 BON BUPB015 Routed to Plana Examiner / / / / 07/30/96 PEND B 11/26/96 BON BUPB025 Reviewed Plans Routed to DSTe / / / / 11/21/96 APPR JHF 11/26/96 BON BUPB028 DST Post- Review Completed / / / / 11/26/96 PASS B 11/26/96 BON BUPB090 (F) Ready to issue / / / / 11/26/96 PASS B 11/26/96 BON BUPB705 Footing Inep / / / / 01/09/97 accepted compaction report PASS RB 01/09/97 RB BUPB706 Foundation Inep / / / / 01/13/97 PASS RB 01/13/97 RB BUPB715 Slab Insp / / / / 01/31/97 PASS RB 02/03/97 RB BUPB730 Framing Inep / / / / 04/08/97 shear req'mt; strap plate -to -beam at FAIL RB 04/08/97 RB main entry; tempered glazing req'mt; strap interior wall- marked; support • framing at access; support ceiling joist at rear bathrm; H -clips missing; nail plate protection; hanger needs additional nailing at weight room; BUPB730 Framing Insp / / / / 04/10/97 pending- nail truss hanger PASS RB 04/10/97 RB mech appliances to be checked at final (above ceiling ok) BUPB745 Insulation Inep / / / / 04/10/97 pending- chink windows /doors where PASS RB 04/10/97 RB lacking; pack lids of both sides of the window unite voids at fwd room; those areas that are hard to reach need to be insulated- check at final for coverage; mach & temp glazing req'mta to be checked at final; BUPB750 Shear Wall Insp / / / / 04/08/97 PEND RB 04/10/97 RB pending- secure HD's where marked BUPB750 Shear Wall Inep / / / / 04/10/97 PASS RB 04/10/97 RB BUPB755 Firewall Inep / / / / 04/16/97 pending - add nailing to 4" ctrl along PASS RB 04/17/97 RB perimeters. BUPB760 Gyp Board Inep / / / / 04/16/97 PASS RB 04/17/97 RB Page No. 2 CASE HISTORY FOR CASE NO.: BUP96 -0599 ANDREWS MANAGEMENT, LTD 08376 SW PFAFFLE ST 04/25/98 • Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By -- -- --- -------- --- BUPB799 Final Inspection / / / / 08/08/97 boiler venting B -vent clearance 1 "- w/ FAIL RB 08/08/97 RB collar venting above roof 2' -10' down spout missing at rear S. corner • pool fencing temporary BUPB799 Final Inspection / / / / 02/02/98 PASS RB 02/02/98 RB BUPC100 (F) Issue permit / / / / 12/26/96 PASS JSD 12/26/96 CTR BUPC705 Foot /Found Insp 07/21/97 / / 07/15/97 Pool: electrical approved 070997/BRP, PART RB 07/21/97 J *H plumbing approval required before foundation can be Advised contractor. Spa: electrical approved 070997/BRP, plumbing approval required before foundation can be approved. Maintain clearance from rebar to earth contact (as on plans). BUPC727 Masonry Inap 07/21/97 / / / / gunite 02/02/98 RB NOT PART OF BUILDING INSPECTION! BUPD400 Development conditions met / / / / 03/06/98 PASS JDA 03/06/98 JDA BUPD950 (F) Issue Cert. of Occupancy / / / / 02/02/98 rb signed /3/19/98 to david 03/19/98 JT • 0 70 -/ f CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hour Inspection Line: 639 -4175 Business Phone: 639 - 4171 q / Date Requested: - r '� — V A.M. P.M. MST': Location: ! 6. J PI S E i / l / / . au— '' 4 :c.' 0 -03* Tenant: c -/2!A 6 i Suite: Bldg: MEC: • 0 I (a Contractor: � (it/ ? Phone: Q--5. / Q -9,9 d 3 PLM: Owner: Phone: ELC: ,/ ` 1 / Qynd . 'la %6 f,(/nol. ELR: BUILDING B con PLUMBING ELEC ' AL SITE Site o Post/Beam ea Cover /Service Sewer /Storm Footing Roof UndFUSlab Rough -In Ceiling Water Line Slab Framing Top Out Gas Line Rough -In UG Sprinkler Foundation Insulation Sewer Hood/Duct Reconnect Vault Bsmt Damp Drywall Storm Furnace Temp Service MISC. Masonry Ceiling Rain Drain A/C UG Slab Shear /Sheath Fire Spklr Crawl/Found Dr Heat Pum Low Volt • 'pro Approved ` Approved Approved Appr /Sdwlk _ .0 • • 6 oved Not Approved t- L ed . Not Approved Not Approved ` FIN • - FINAL FINAL FINAL • )----\ r i C , 'lb _...../' O Call for reinspection O Reinspection fee of $ required before ne tion O Unable to inspect Q 'f Inspector: $ Date: 2 6 / a Page of l