Permit • CITY OF TIGARD MASTER PERMIT PERMIT #: MST2000 -00005 . V Illy DEVEL ICES DATE ISSUED: 01/18/2000 13125 SW SITE ADDRESS: 08950 SW PIPPEN LN ` I �'t N A L PARCEL: 2S111DA -15400 SUBDIVISION: APPLEWOOD PARK NO. 3 ZONING: R -7 BLOCK: LOT: 147 JURISDICTION: TIG REMARKS: New SF - Path 1 BUILDING REISSUE: STORIES: 2 FLOOR AREAS REQUIRED SETBACKS REQUIRED CLASS OF WORK: NEW HEIGHT: 23 FIRST: 1,034 sf BASEMENT: sf LEFT: 4 SMOKE DETECTORS: Y TYPE OF USE: SF FLOOR LOAD: 40 SECOND: 1,286 sf GARAGE: 495 sf FRONT: • 22 PARKING SPACES : 2 TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: sf RIGHT: 4 VALUE: $ 173,897.00 OCCUPANCY GRP: R3 BDRM: 3 BATH: 3 TOTAL: sf REAR: 19 PLUMBING SINKS: 1 WATER CLOSETS: 3 WASHING MACH: 1 LAUNDRY TRAYS: 1 RAIN DRAIN: 100 TRAPS: LAVATORIES: 4. DISHWASHERS: 1 FLOOR DRAINS: SEWER LINES: 100 SF RAIN DRAINS: 1 CATCH BASINS: TUB /SHOWERS: 3 GARBAGE DISP: 1 WATER HEATERS: 1 WATER LINES: 100 BCKFLW PREVNTR: 1 GREASE TRAPS:. OTHER FIXTURES: ' MECHANICAL . FUEL TYPES FURN < 100K: BOIUCMP < 3HP: VENT FANS: 5 CLOTHES DRYER: 1 GAS FURN > =100K: 1 UNIT HEATERS: HOODS: 1 OTHER UNITS: 1 MAX INP: btu FLOOR FURNANCES: VENTS: WOODSTOVES: GAS OUTLETS: 1 ELECTRICAL RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS 1000 SF OR LESS: 1 0 - 200 amp: 0 • 200 amp: W /SVC OR FDR: 1 PUMP/IRRIGATION: PER INSPECTION: EA ADD'L 500SF: 4 201 • 400 amp: 201 - 400 amp: 1st W/O SVC /FDR: 00 SIGN /OUT LIN LT: PER HOUR: LIMITED ENERGY: 401 - 600 amp: 401 • 600 amp: EA ADDL BR CIR: • SIGNAL/PANEL: IN PLANT: MANU HM/SVC /FDR: 601 - 1000 amp: 601 +amps- 1000v: MINOR LABEL: 1000+ amp/volt : PLAN REVIEW SECTION . • Reconnect only: >=4 RES UNITS: SVC /FDR> =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC: ELECTRICAL • RESTRICTED ENERGY A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO: VACUUM SYSTEM: AUDIO & STEREO: FIRE ALARM: INTERCOM/PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM: OTH: BOILER: HVAC: LANDSCAPE/IRRIG: PROTECTIVE SIGNL: GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR: HVAC: DATA/TELE COMM: NURSE CALLS: TOTAL # SYSTEMS: Owner: Contractor: TOTAL FEES: $ 5,757.55 LEGEND HOMES LEGEND HOMES This permit is subject to the regulations contained in the ST 1EGE LEGEND O 72ND CORP CO Tigard Municipal Code, State of OR. Specialty Codes and 6900 LEGEND HAINES TIGARD, OR 97223 TIGARD, OR 97223 all other applicable laws. All work will be done in . accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if the , work is suspended for more than 180 days. ATTENTION: Phone: Phone: Oregon law requires you to follow rules adopted by the • Oregon Utility Notification Center. Those rules are set Reg #: LIC 00060563 forth in OAR 952 - 001 -0010 through 952 - 001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503) 246 -1987. REQUIRED INSPECTIONS Erosion 844 -8444 Underfloor insulation Plumb Top Out Low Voltage Appr /Sdwlk Insp Building Final 'Footing lnsp Crawl Drain /Backwater Electrical Service Gas Line Insp Electrical Final Foundation Insp Footing /Foundation Dn Electrical Rough In Gas Fireplace Mechanical Final Post/Beam Structural PLM /Underfloor Framing lnsp Insulation Insp Plumb Final ° Post/Beam Mechanical Me • -n' -I I Shear Wall Insp Rain drain lnsp Final inspection Issued By : `. / Permittee Signature // 7 i,/ i �� Call (503) 639 -4175 by 7:00 p.m. for an inspection needed th - ne busi ess day CITY VI I ILiAKL) Kesiaential builaing Permit Application Plan Che 2- 13125 SW HALL BLVD. Additions or Alterations Recd B TIGARD, OR 97223 Single Family Detached or Attached (Duplex) Date Recd -a _ V 903- 639 -4171 Data to P.E. 1- - F 5133 -684 -7297 Date to DST /- io -o u Permit # fkit -• 'p5' Print or Type Called I 11. Incomplete or illegible ap lications will not be accepted ` 1 z 2 DQ' -` t)coL / y7 if 7 Name of Project Name �� �/ Job AM.ra),4) PA /(1f L.p �// c9hD)/ Address sne Add _ _Architect Mailin Address Nam �� D ,' 61 Cit /Sta e . Vip e - hon � �Y1 n ) Z q,.�,/ • /s� Owner Mailin re ss / 7111,6 S Name / r • / r ,�,� �� f /4,n En ineer Mailing Address General N;' - K�' { : - C : t `' , ,.� .f{ ,: : ' 'fz' • . . . - :"y ;ii! ' Y: r .:i.l;r.' ', - _ r w �f �!i. - . ;, � � ' .Con � ;� : � :; • �°s�� ".` �" '',1.1'''7*..- . ;, , : •5 'ay ` yr .> r D e sc r ibe wo rk N y� :Additio o ;t Alteration 0 : : * - i . ..,. $. .. ��- t4 '�c ` y am' • : ,;., ..g , E:: . 17 �S .'�: . . �. teas • :: . -4i ;; 'r : ..x' �.;; - T:. to bA'dOne. a :� + rs . �:: r.. a' ��!! 9.� . ' :.. • Pr to un t �i� ' P8 t ' -- -wry-- 41 Ad • dlHofia) eh. BS:ariPtion f Wgric: . r . ' 4 ., p 4 .„, ; ' r ; 4 Issuance, a _ c opy .'/ ta „• y LL v ,.�.• : ,-• �• .,1X !r 31=7.. . *.v q�:.I �r'.t••y,� G `l: 6'' 4 �. • t i17 � (' ^. = 1 ^ PtNphone • } • F. li � •�1.•�� O M�..•.4.�lGY :'.F':/��!):i ]•���0��V�i l . \ . K� '1r� .r of all Ucenses • ' dy► ' 1 3 �r :, �s�'i,'� l .;; `, "� : .. _ �, w , , •are required If _ �. O on ns tCont. Bo ard . -, Exp., ^ r r_ PRO CT. ; �' . expired In COT: Uc.# -. .. ;�:`,; .. : s:y. : . , x,... mo ; � � • _ . 0� = - �3 - . , : i;'... `{- ...4 .V � �: � 37Z Mechanical Nye _ : :'3: NEW, CONSTRUCTION ONLY' 4f=' ?� , ` �_ �' t1 � : , Z et t" ) , •. =t• : ! S Ft. House I Sri; Ft Garage ` �'.." I Mailing . Contractor ailing Addre L A .' _ pZ � r . Indicate the restricted energy installation / ) - . Prior to permit a �� �OS_ ��/ by the electrical : ' • issuance, a copy C• /State • Zip Phone Subcontractor in the following areas . r ::'` of all licenses Poi i ? - 7 Restricted • Audio/Stereo ; • - , -- . are required if Oregon Const. Cont. Board Exp. Date Energy System Alarms expired in COT Uc.# Installations Vacuum Irrigation database �'j /Y/ 5 7- 3 - %l'i System System Plumbing Name (check all that . Other: . y - Sub- (,) DJ 0 0# [J1' apply) Contractor Mailing Address Comer Lot YES Ng Flag Lot YES NQ /'U /r Q l !` (check one) ,/� [� Has the Subdivision Plat recorded? N/A YES NO Prior to permit C�' /S tate Zip Phone J` issuance, a copy ( 0/D - ) /,7•'•ydc>/ - of all licenses are Oregontonst. Cont. Board Exp. Date required if Uc.# �/� expired in COT • 66002-3P ID- l i t . I hearby acknowledge that I have read this application, that the database , Plumbing Uc. # Exp. Date information given is correct, that I am the owner or authorized agent of the owner, and that plans submitted are in compliance with o - �o P3 '3� ! 0 Oregon State laws. t Name `` Sign lire of ner gent Date Electrical M a /A " �. �' 2! /2 .v �• - /y - , Cont a nlda Sub- Mailing Address ,J�' /C /{/ /J / „ v% Phone Contractor ,3 I J5 a-w 7 ar / /`� ' City /State Zip Phon • (t' "�09S0 Prior to permit • issuance, a copy ,/4 /(j )q S y/- -/ - FOR OFFICE USE ONLY: of all licenses are Oregon Const. Cont. Board Exp. Date required if uc e Plat # �n 2� Map/TL#: _ expired in COT / A //5 _ 3 —/ /-()(, ' I . A �! l� �JZ / :0 . / 1)U database Electri tic. #. Exp . Dte . D Zone: n 7 n Solar � S C /- Fiji mi / gyp - r Electri Supervisor Lie. # p uate En nee 'ng Approval: Planning Approval: • TIF: • 1X0 5 Id - / -V/ ,---, -4 - A eS • t.•Idstslformsls doc 11/20/98 . • 5/17/00 Activities for Case #: MST20O0 -00005 1:41:13 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA005 Application received 12/29/99 DRA RECD No Hold BON 1/4/00 , MSTA008 Permit Created 1/4/00 BON DONE No Hold BON 1/4/00 MSTA010 Check for prd. restrict. 1/4/00 BON DONE No Hold BON 1/4/00 MSTA012 Plans routed to Plans Examiner 1/4/00 BON DONE No Hold BON 1/4/00 MSTA026 Plans approved by Pln Examiner 1/10/00 BT2 DONE No Hold BT2 1/10/00 MSTA030 Reviewed plans routed to DSTS 1/10/00 BT2 DONE No Hold BT2 1/10/00 MSTA700 Erosion 844 -8444 1/7/00 1/7/00 No Hold . BT2 1/7/00 MSTA705 Footing Insp 1/7/00 1/7/00 1/24/00 RB PASS No Hold AKJ 1/24/00 2) provide 2 bars at gar wings for vertical seismic req . 3) provide low point crawl drain 4) maintain 4' centers for rebar keyway conn MSTA706 Foundation lnsp 1/7/00 1/7/00 1/25/00 TLP PASS No Hold AKJ 1/25/00 MSTA710 Post/Beam Structural • 1/7/00 1/7/00 2/1/00 KS PASS No Hold AKJ 2/1/00 MSTA711 Post/Beam Mechanical 1/7/00 1/7/00 2/1/00 KS PASS No Hold AKJ 2/1/00 MSTA712 Underfloor insulation 1/7/00 1/7/00 No Hold BT2 1/7/00 MSTA713 Crawl Drain /Backwater valve 1/7/00 1/7/00 1/27/00 MRS PASS No Hold AKJ 1/27/00 MSTA714 Footing /Foundation Drain 1/7/00 1/7/00 No Hold BT2 1/7/00 MSTA717 PLM/Underfloor 1/7/00 1/7/00 1/31/00 MRS PASS No Hold AKJ 1/31/00 MSTA720 Mechanical lnsp 1/7/00 1/7/00 3/14/00 KBS FAIL No Hold AKJ 3/14/00 see framing 3/14 MSTA722 Plumb Top Out 1/7/00 1/7/00 3/3/00 TLP PASS No Hold AKJ 3/5/00 MSTA723 Electrical Service 1/7/00 1/7/00 3/14/00 BRP PASS No Hold AKJ 3/14/00 MSTA724 Electrical Rough In 1/7/00 1/7/00 3/14/00 BRP PASS No Hold AKJ 3/14/00 MSTA725 Framing Insp • 1/7/00 1/7/00 3/14/00 KBS FAIL No Hold AKJ 3/14/00 1) need elec cover app 2) extend insul shield at b vent , - at attic and maintain clearance 3) secure fireplace 4) truss dip missed at girder truss upper front bdrm 5) provide Is 50 at M beams to plates 6) gas test ok ok to insul after elec cover is app MSTA726 Shear Wall Insp 1/7/00 1/7/00 2/25/00 KS PASS No Hold AKJ 2/27/00 MSTA728 Low Voltage 1/7/00 1/7/00 No Hold BT2 1/7/00 MSTA735 Gas Line Insp 1/7/00 1/7/00 3/14/00 KBS PASS No Hold AKJ 3/14/00 Page 1 of 2 5/17/00 Activities for Case #: MST2000 -00005 1:41:13 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA736 Gas Fireplace No Hold BT2 1/7/00 MSTA740 Insulation Insp 1/7/00 1/7/00 3/16/00 GW PASS No Hold AKJ 3/16/00 MSTA752 Rain drain Insp 1/7/00 1/7/00 1/27/00 MRS PASS No Hold AKJ 1/27/00 MSTA765 APpr /Sdwlk Insp 1/7/00 1/7/00 3/24/00 MW PASS No Hold AKJ 3/26/00 MSTA790 Electrical Final 1/7/00 1/7/00 5/4/00 CD PASS No Hold AKJ 5/4/00 MSTA795 Mechanical Final 1/7/00 1/7/00 5/11/00 TLP PASS No Hold AKJ 5/11/00 MSTA797 Plumb Final 1/7/00 1/7/00 5/4/00 MRS FAIL No Hold AKJ 5/4/00 house locked MSTA798 Final inspection 1/7/00 1/7/00 No Hold BT2 1/7/00 MSTA799 Building Final 1/7/00 1/7/00 5/11/00 TLP PASS No Hold AKJ 5/11/00 MSTA032 DST Post - Review Completed 1/11/00 BON DONE No Hold BON 1/11/00 MSTA080 (F) Ready to issue 1/11/00 BON DONE No Hold BON 1/11/00 . MSTA092 (F) Issue combination permit 1/18/00 GEO DONE No Hold GEO 1/18/00 MSTA095 Issue plumbing signature form 1/18/00 JMT RECD No Hold JMT 1/18/00 MSTA097 Issue electric signature form 1/24/00 SLT RECD No Hold ST 1/24100 MSTA761 Water Service Insp 1/27/00 1/27/00 1/27/00 MRS PASS No Hold AKJ 1/27/00 MSTA728 Low Voltage 3/14/00 BRP PASS No Hold AKJ 3/14/00 MSTA725 Framing Insp 3/16/00 GW PASS No Hold AKJ 3/16/00 MSTA797 Plumb Final 5/5/00 MRS PASS No Hold AKJ 5/7/00 sewer clean out needs a cap MSTA960 (F) Issue Cert. of Occupancy 5/11/00 TLP DONE No Hold ST 5/17/00 5 /17 /00- mailed to owner /file • Page 2 of 2 CITY OF TIGARD BUILDING INSPECTION DIVISION MST OOd — C`9O b S 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested S AM y PM BLD Location o� O P pP / LPL. Suite MEC Contact Person Ph —3 3 PLM Contractor Ph SWR ILDIN Tenant/Owner ELC e aining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: �70 PART FAIL •I I MBING Post & Beam Under Slab Top Out Water Service • Sanitary Sewer Rain Drains Final PASS PART FAIL M Er ANI Z Post & Beam Rough In Gas Line S • ► Dampers ` � PART FAIL - + RICAL Service Rough In UG /Slab Low Voltage Fire Alarm./ Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk✓ Date ]' Other Inspector I 1m Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. 1 CITY OF TIGARD BUILDING INSPECTION DIVISION MST ZcoD-Occo 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 5 .S1 AM PM BLD F Location � d .PI Suite MEC Contact Person `"f r � Ph VA -3 ) PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall / Fire Sprinkler Fire Alarm rV • A Susp'd Ceiling / Roof Misc: - Final PASS PART FAIL ost Under Slab Top Out Water Service Sanitary Sewer Rain Drains PART FAIL CHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL - SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk t Other Date S Inspector -� Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 2,000 -S 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested s/sl AM PM BLD Location �cIS pl62, Suite MEC Contact Person 'rE�.� Ph it 9 - 3376 PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing //;/4'L oN / O 0 Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PA FAIL EC Service Rough In UG /Slab Low Voltage Fir - darm ____ PART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk D Inspector Other Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 2100 - 0S 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 /00 BUP Date Requested Sit -( AM V PM BLD Location � D Pip2e Suite MEC Contact Person 1 Ph 74 - 33'X PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler G Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final • PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL C Service Rough In UG /Slab Low Voltage Fire Alarm PART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date e9,0 Inspector /1.�.�� Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.