Loading...
Permit . . Ali . CITY OF TIGARD MASTER PERMIT • PERMIT #: MST2000 -00099 - ;l�� DEVELOPMENT SERVICES DATE ISSUED: 04/14/2000 �.� J i 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 SITE ADDRESS: 08900 SW PIPPEN LN PARCEL: 2S111 DA -15200 SUBDIVISION: APPLEWOOD PARK NO. 3 ZONING: R -7 BLOCK: LOT: 145 JURISDICTION: TIG REMARKS: New SF - Path 1 BUILDING REISSUE: STORIES: 2 FLOOR AREAS REQUIRED SETBACKS REQUIRED CLASS OF WORK: NEW HEIGHT: 22 FIRST: 1.127 sf BASEMENT: 0.00 sf LEFT: 4 SMOKE DETECTORS: Y TYPE OF USE: SF FLOOR LOAD: 40 SECOND: 1.294 sf GARAGE: 488 sf FRONT: 22 PARKING SPACES : 2 TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT: 5 VALUE: $ 180,934.21 OCCUPANCY GRP: R3 BDRM: 3 BATH: 3 TOTAL: 2,421.00 of REAR: 16 PLUMBING SINKS: 1 WATER CLOSETS: 3 WASHING MACH: 1 LAUNDRY TRAYS: 1 RAIN DRAIN: 100 TRAPS: LAVATORIES: 4 DISHWASHERS: 1 FLOOR DRAINS: SEWER LINES: 100 SF RAIN DRAINS: 1 CATCH BASINS: TUB/SHOWERS: 3 GARBAGE DISP: 1 WATER HEATERS: 1 WATER LINES: 100 BCKFLW PREVNTR: 1 GREASE TRAPS: OTHER FIXTURES: MECHANICAL FUEL TYPES FURN < 100K: BOIL/CMP < 3HP: VENT FANS: 5 CLOTHES DRYER: 1 GAS FURN > =100K: 1 UNIT HEATERS: HOODS: 1 _ OTHER UNITS: 1 MAX INP: btu FLOOR FURNANCES: VENTS: WOODSTOVES: GAS OUTLETS: 1 ELECTRICAL RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS 1000 SF OR LESS: 1 0 - 200 amp: 0 - 200 amp: W /SVC OR FDR: 1 PUMP/IRRIGATION: PER INSPECTION: EA ADD'L 500SF: 4 201 • 400 amp: 201 • 400 amp: 1st W/O SVC /FDR: 00 SIGN /OUT LIN LT: PER HOUR: LIMITED ENERGY: 401 • 600 amp: 401 - 600 amp: EA ADDL BR CIR: SIGNAL/PANEL: IN PLANT: MANU HWSVC/FDR: 601 - 1000 amp: 601 +amps- 1000v: MINOR LABEL: 1000+ amp/volt : PLAN REVIEW SECTION Reconnect only: >=4 RES UNITS: SVC /FDR =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC: ELECTRICAL - RESTRICTED ENERGY A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO: VACUUM SYSTEM: AUDIO & STEREO: FIRE ALARM: INTERCOM/PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM: OTH: BOILER: HVAC: LANDSCAPE/IRRIG: PROTECTIVE SIGNL: GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR: HVAC: DATA/TELE COMM: NURSE CALLS: TOTAL # SYSTEMS: Owner: Contractor: TOTAL FEES: $ 5,802.96 This permit is subject to the regulations contained in the MATRIX DEVELOPMENT CORP LEGEND HOMES CORP all other r applicable Code, . All work k w l b e d o n e Codes and 6900 SW HAINES ST STE 200 12755 SW 69TH AVE #100 all other applicable laws. All work will be done in TIGARD, OR 97224 TIGARD, OR 97223 accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if the work is suspended for more than 180 days. ATTENTION: Phone: Phone: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set ORIGINAL Rep #: LIC 00060563 forth in OAR 952 - 001 -0010 through 952 - 001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503) 246 -1987. REQUIRED INSPECTIONS Erosion 844 -8444 Underfloor insulation Plumb Top Out Gas Line Insp Appr /Sdwlk lnsp Building Final Footing Insp Crawl Drain /Backwater Electrical Service Gas Fireplace Electrical Final Foundation Insp Footing/Foundation Dry Electrical Rough In Insulation lnsp Mechanical Final Post/Beam Structural PLM /Underfloor Framing Insp Rain drain Insp Plumb Final Post/Beam Mechanical Mechanical lnsp Shear Wall Insp Water Line Insp Final inspection /. Issued B : NL 6,„,(/� Perm ittee Signa - _ `�_— ��' // By N.- Call (503) 639 -4175 by 7:00 p.m. for an inspection needed the next b. Hess day CITY Ur I IciAKL) Kestaential tiuilaing Permit Application Plan Check ga 13125 SW HALL BLVD. Additions or Alterations Recd By TIGARD, OR 97223 Single Family Detached or Attached (Duplex) Date Recd 3 - - d V 503- 639 -4171 Date to RE. i_ _ _ wp F 503 -684 -7297 Date to DST / Q- _ O Permit* ST2.O!'a'� - 9 Print or Type Cased yid sa Incomplete or illegible applications will not be accepted 5w(7 - - cxCez Name of Project Name Job A oi2L.g / ) P/4 /24 L lo �. _ ■ ��. � Address Site Addre Architect Mailing Ad eg (s Nam / P S ~ ��� - Zip P nom• Owner M j "g re . C/,f/ � V � � '. • Cry rf Phone .. Engineer . Mailing .• _ • • . • ::;, -.'' . :•::z , . �:'r = _ 4 -; .''; .., , . •:f ,i�4C .' -' '.1 ,. •' ° s ., � ' -� . � � . � °,� w. x :•:; i . : Y.��:r = • . ,ww�;: �� • • - :, - --' 'A: 1 � , ,� 'Addition 0,7t Alteration; 0 ::: :::° �. • �.;Itt IMO, _�' - ... 51.;-t- . � 'r ,.„1�4� t J' '' %iW : ..4 . ;. j y'? . . .• - s n i • • '•T _ ; r. i - _ . ;'�' 7 ��'•� +.yj :;is ' /%f'S"j w : {" - - .lt' �• %�"'` . • • � Prb permit f_ ' - / _ - - �; ;.� _ '..:r_ ,:. - ;-: .�r: • . t . y f , -' - _ , / �, - s r ► . ` • AdditIofial Descrtption of Work. i3; ?1k: e• . r %; i 1 : i. Iss uance, a copy 1� tae . •, c 1 . n _ ' � . • M :. s ./• w.� gum v =Tri i:�. !. a '4'•�t e ' r""K * `' w k k y' }' of all licenses t :• T, , / :.F ....,. �, .. -.... . 5 - . , - e a • K reg ' • nst.. • n D : ` `: : l •are required i- . • O on _ y .... _ .: � -1. �•:# : P R�CT' ;�:. � Y Z j - - ��'., expired In COT •�• • Ale.* _ ;is,'. ' .;.ve . .s ' • x, • ' database: ..: j9 !^ .,. r�;i:W .'9 .b• , ; V A Lt ' l v - Mechanical N� '• ::::::" - - : ,_ .... - NEW CONSTRUCTION ONLY: .. ¢ _ = :� Su & .. ' �' : L - oz _-_;, . Sq. Ft : -�. , 1 Sq:' FL Garage '",`,..,#,,, Mailing _ Contractor ng Add • l . , ,� • • � �aZl � i. . " 7 o � • Prior to permit eg 7 S � , � 9 3 /- ."v E I ndicate the restricted energy installation by the electrical.; • • . , • Issuance, a copy C' /State Zip Phone r subcontractor in the following areas ' .. • • - '1: r••:•` of a0 licenses P P' f -,� d <3- -77r/ Restricted • : • Audio/Stereo ; . are required if Oregon Const. Cont. Board Exp. Date . System • Alarms ' expired. in COT Uc.# / Installations Vacuum Irrigation database () � / S� -3 - - . . Plumbing Name (check all that . Other System .Sub- (,)4'° piwrIA apply) .. . Contractor Mailing Address , j Comer • Lot YES Nq Flag Lot YES N • I) 8 o I • o U 7 V (check one) (check one) Has the Subdivision Plat recorded? I N/A NO Prior to permit Cy/State ! Zip Phone issuance, a copy (0-f D ,1 71 • 7- •C,,�g/ of all licenses are Oregon Cont. Cont. Board Exp. Date required if - Uc.# expired COT • (960,,L3cp `t9 - / G ) .. I hearby acknowledge that I have read this application, that the database Plumbing tic. # Exp. Date information given is correct, that I am the owner or authorized agent of the owner, and that plans submitted are in compliance with a6 -�00� p 3 o ''3) !, Oregon State laws. Name `` _ Signure of er gent . _ _ / Date Electrical (04'/'/l.�'1 �. � .2 Cont r� ��2 a ,.,o �'i� 2--/-t. Electrical � 'F Ia Sub- Mailing Address - � � j ✓ Phone Contractor ,y f 71)5` .s , e i v g `, 1 7 • ' City /State Zip Phone' / 6.90 - gtvSv • Prior to permit issuance, a copy Ale)) . 5 yf • of an licenses are Oregon Con Cont. Board Exp: Date FOR OFFICE USE ONLY: required if Lice / Plat #: • Map/11.#: expired in COT / L / /,5 g _ . -/y,0 , -• z - - Lf. L1 •' 3 3z- _ 5 //P - / 5 A v database Electrical I,lc. #, . Date - � Seize Zone: — ^� - l s c 0- J, iI f/ [ Electrical Supervisor Uc. # / s 1 r � Pe p . uate I:ngineerin A royal: Plannin Approval: TIF: .J .70 7 5 , /0 - / - V/ ; ' ' g L / - b - 2 . XU , 9 , e() • - L•ldstslforms�sfaddait.doc 11/20/98 Sap -13 -99 11:21A Wolcott Plumbing 603 667 9891 P.01 • A/1 ST .CIZZI CD-C9 P.01 1' 1' OLCOTT Street Address Mailing Address 2050 N.W. Burnside P.O. Box 2007 pL v` ►:1�O Gresham, Oregon Gresham, OR 97030 (503) 667 -1781 Fax (503) 667 -9891 CONTRACTORS, INC. RE CEIVFD CC6e23847 APR 1 7 2000 BY: August 23, 1999 Bldg. Dept. Ali d„„„J 4 "( N-5 City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Wolcott Plumbing Contractors, Inc. do hereby authorize Peg Molony of Legend Homes to represent this firm when applying for plumbing permits inside the jurisdiction of The City of Tigard. Wolcott Plumbing Contractors, lac. realize that should the agreement with Legend I lomcs terminate, we have the right to withdraw our consent. Ccvy I Q e z 1 Iv-6 Name Title AAx- 4�- 23--91 Si turc Date 26 -208PB 99 -4281 State Plumbing Business No. City license No. CITY OF TIGARD 13125 S.W. HALL BLVD. TIGARD, OR 97223 IMPORTANT PERMIT NOTICE WOLCOTT PLUMBING CONT. INC PO BOX 2007 GRESHAM, OR 97030 Plumbing Signature Form Permit #: MST2000 -00099 • Date Issued: Parcel: 2S111 DA -15200 Site Address: 08900 SW PIPPEN LN Subdivision: APPLEWOOD PARK NO. 3 Block: Lot: 145 Jurisdiction: TIG Zoning: R -7 Remarks: New SF - Path 1 Your company has been indicated as the plumbing contractor for the permit indicated above. In order for the plumbing permit to be valid, please have the appropriate individual from your company sign below and return this Plumbing Signature Form prior to the start of the work to the address above, ATTN: Building Dept. No plumbing inspections will be authorized until this completed form is received OWNER: PLUMBING CONTRACTOR: MATRIX DEVELOPMENT CORP WOLCOTT PLUMBING CONT. INC 6900 SW HAINES ST STE 200 PO BOX 2007 TIGARD, OR 97224 GRESHAM, OR 97030 Phone #: Phone #: 667 -1781 Reg #: LIC 00023847 PLM 26 -208PB AN INK SIGNATURE IS REQUIRED ON THIS FORM X Signature of Authorized Plumber • If you have any questions, please call (503) 639 -4171, ext. # 310 CITY OF TIGARD 13125 S.W. HALL BLVD. TIGARD, OR 97223 R. p-'rV- IMPORTANT PERMIT NOTICE APR 2 4 2000 GARNER ELECTRIC 21785 SW TUALATIN VALLEY HWY S ALOHA, OR 97006 -1248 Electrical Signature Form Permit #: MST2000- 00099 Date Issued: Parcel: 2S111 DA -15200 Site Address: 08900 SW PIPPEN LN Subdivision: APPLEWOOD PARK NO. 3 Block: Lot: 145 Jurisdiction: TIG Zoning: R -7 Remarks: New SF - Path 1 Your company has been indicated as the electrical contractor for the permit indicated above. In order for the electrical permit to be valid, the signature of the supervising electrician is required. Please have the appropriate individual from your company sign below and return this Electrical Signature Form prior to the start of the work to the address above, ATTN: Building Dept. No electrical inspections will be authorized until this completed form is received OWNER: ELECTRICAL CONTRACTOR: MATRIX DEVELOPMENT CORP GARNER ELECTRIC 6900 SW HAINES ST STE 200 21785 SW TUALATIN VALLEY HWY S TIGARD, OR 97224 ALOHA, OR 9 700 6 -1 248 Phone #: Phone #: 591 -1320 Reg #: LI 121159 SUP 3707$ ELE 34 -305C AN INK SIGNATURE IS REQUIRE T S F • - M X / // Sig ure of Supervising Electrician If you have any questions, please call (503) 639 -4171, ext. # 310 • CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hoer Inspection Line: 639-4176 Business Line: 639 -4171 0,Z000-U0099 • G i,; BUP Date Requested d 1 AM PM BLD Location f v U 5 w , P , P . L ,� Suite MEC Contact Person Ph,;49- 3 3 20 PLM Contractor Ph SWR IL Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing loRJ C$1 n& .- C t. t• Insulation Drywall Nailing - 1A.1 2 S. - 7— 00 Firewall �� ��" Fire Sprinkler 06) - *Su Pt iEr cA 5 r�CPL NLS C .alLrzuu L. COAreA Fire Alarm Susp'd Ceiling Roof Misc: AS ART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL EC NIC L� Post & Beam Rough In Gas Line Smoke Dampers ina S PART FAIL E LECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk � �p� Other Date Inspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST oO ' - aU u 9 ? 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested - y AM PM BLD Location q G U Pi P/' -e,-. C/ - Suite MEC Contact Person Ph -v9 33 70 PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall - ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing � Firewall /J� N (4)fat j� Fire Sprinkler / / n �U / �l 5 /%1 w« 'Q� Fire Alarm p�J/J F d �/ T Susp'd Ceiling '2 (O <) r (k i Afie r ! SAut h--' /71/OS'. A 4 Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out • Water Service Sanitary Sewer Rain Drains in SS PART FAIL • • MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA ■S' Approach /Sidewalk Date o.0 Inspector _ �.' � / Ext Other — Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST i,vv G c/oFy 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 1- Y AM PM BLD Location f G. tP flf..� -� L Suite MEC Contact Person Ph a29— s 3 7 U PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing % Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof • Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PAST FAIL V CTRICEAL, ice Rough In UG /Slab Low Voltage Fir- Alarm PART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date $ I 92 90 Inspector k i 4/ . 4 .4 L Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST �,va �vv fi 24 -Hour insp Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested AM PM BLD Location 8'922 s w p ,ei.-1 '^ Suite MEC Contact Person T-1 re" Ph 9— 3) 7 U PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL LUM - Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain II rains r • PART FAIL • CHANICAL Post & Beam - Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA O p h e oach /Sidewalk Date - �L I 2/61 Inspector i Ext - G Final I PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST WD -0009 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested / /ci')o AM PM BLD Location l 00 P / � ,,I Suite MEC Contact Person I £Pj - J2L Ph 6 92-QS'? PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinsp ction RE: [ ] Unable to inspect - no access ADA 1 4 ' L Date 6 ( Z4- Inspector 1 1 - LLJi Ext i_ PASS PART FAIL D N T REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 7O - COO?? 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested ( /(o% AM V PM BLD ■ Location 9 by �I pppi/4 L1A. Suite MEC Contact Person T A J CDR Ph ? 7b PLM Contractor Ph SWR • BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN • Crawl Drain Inspection Notes: Slab SIT Post & Beam at Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final • PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final ART FAIL 4I11gCHAN CA Po Beam o . , NIP as Line Smoke Dampers Final PART FAIL VARICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach/Sidewalk Dat l� l/ 0 I Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION Msr arn0 - OOn9 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 _� BUP -141114.' Date Requested (/7/00 AM PM BLD MOO Location P p f->C Suite MEC Contact Person 1? .1 Ph S 9 e' a3 PLM - Contractor Ph W7-3370 SWR N� Tenant/Owner ELC Retaining Wall • ELR Footing Access: Foundation FPS • Ftg Drain SGN Crawl Drain Inspection Notes: Slab • SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing sula i Drywa I Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: 4C41 F'• PART FAIL BING Post & Beam Under Slab Top Out • Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL - - Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date 0)/0d nspec It 1 Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 2 WO 24 -Hour Inspection Line: 639 -4175 Business Line: 639-4171. \ / BUP Date Requested S © quested (n O AM 1L PM BLD O Location %900 p; Suite MEC Contact Person eA Ph ZD — 3 ' ,37d PLM Contractor Ph SWR UILD N Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int S ath /Shear rmin Age nsu ation � - n Drywall Nailing C t! '�f 6 �A Firewall Fire Sprinkler C/ .c i ' ; 5 .L Fire Alarm A , _ !10 w Susp'd Ceiling ' �� • 7 / J ' f Roof SO FT / Misc: F. « PART FAIL P U BING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL Post & Beam % Li Smoke Dampers Final PASS PART ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other D a U U Inspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST — (3O 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Re uested - AM X PM BLD ' 9 Location 4406 / � // V7 [.1t Suite MEC Contact Person 7 ( Ph 27 3 3 76 PLM • Contractor Ph . SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing , f Insulation Drywall Nailing i -• // i ∎ A Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line • Smoke Dampers Final PASS PART FAIL UG /Slab Low Voltage Fire Alarm F ' AS PART FAIL ITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach/Sidewalk Other _ v Inspector .i1 _� Ext Other Final PASS PART FAIL 0 NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST ISOYC O 9 9 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 / BUP 2 �C) Date Requested p 5 AM PM BLD Location $9 fY QI Suite MEC Contact Person �:� Ph 2.09 - 3 3 70 PLM Contractor Ph SWR UILD ' Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear n eath/ ramin Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: F. i PART FAIL Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL - Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call fo reinspe 'xi RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk t I D ate Inspector Other Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST WOO - 0009 1 3 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 5/2;y00 AM PM BLD Location 0 q OO P I I) , Suite MEC Contact Person \DOt (PW Ph &(o / 7 0 I PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS • RT FAIL I 1 F3 Pos & Beam U • - lab Top O5 Water Service Sanitary Sewer Rain Drains PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final • PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL • SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk ��jj Other Date _ I Inspector /!17 Ex Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 213C6-0OO p 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 / BUP Date Requested p �,�0 AM PM BLD Location D ci oo T 1 `� Suite MEC Contact Person fit' 611, D Ph 0/0747v PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain Crawl Drain Inspection Notes: SGN Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler • Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL st & Under Slab Top Out Water Service Sanitary Sewer Rain Drains PART FAIL ' ' ANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE • Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hail, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA f � Approach /Sidewalk // 2 / (� Other Date V V Inspector )1'-? Ext Final PASS PARS -- -FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST - Zo 5t)-(Do� 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested i . g/OD AM PM BLD Location 9 1'O() Pi e) 1. Suite MEC Contact Person 'T k4')1 Ph soq -33 70 PLM Contractor Ph S WR l?1LDINJC`) Tenant/Owner ELC R Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT P 4141:1 11 " _ E eath /Shear Int Sheath /Shear �+ Framing �J 'Si) ► ' P /CT i—.� re-M. CS; r L « u !.0 CO C 2. c Insulation Drywall Nailing i/14 el1AL. • Firewall Fire Sprinkler C _ ..�• (A- +.. • o — e nJC/ — • — Fire Alarm Susp'd Ceiling ..e' 6d2, t o.aTErGt it fe &S412. id 4 �� ?t: •rrs Roof Misc: 14 .*l S• Final PART FAIL MBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL M P■jy Roug n Gas Line Smoke Dampers Final PASS PAR FAIL ELECTR L Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date V Inspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 7 ! ^ ,fi - O 2 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date G Requested Z7 00 AM PM BLD Location ' 1 0 0 el p� '., Suite MEC Contact Person D W c 4 c,O-1 , 1' Ph Co Co 7 — 1 78' I PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam • Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall / • Fire Sprinkler r / Fire Alarm Susp'd Ceiling — _ _ • / Roof Misc: //!I _ Z Final PASS PART FAIL r • ost & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART A MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers • Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab • Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date tr ." Inspector Inector /7,7 '7/ Ext Other Final PASS PART FAIL 0 NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION Msr ZG c0!)09 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested x/00 AM y PM BLD Location p g b D p( p p Suite • MEC Contact Person 6 Ph 7g0 27 j PLM Contractor • Ph SWR ILD Tenant/Owner ELC etaining Wall ELR Footing Access: FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing i A."7""LC .4rrC /, I-, L TS S'7c gl S Insulation Drywall Nailing ,lS Firewall Fire Sprinkler 2 • ,4.47 •: •n�;.c - o .- Fire Alarm Susp'd Ceiling Roof Misc: Fina AS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date l .1/7 — od Inspector ZA,., Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 2t00• `J 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested yivoi AM �PM BLD Location '1 OO 2 i b o/D& \, Suite MEC Contact Person Ph 7'O -/ Z 7 ( PLM Contractor Ph SWR UILD ► Tenant/Owner ELC f fining Wall ELR Foundation Access: FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing C" >n<,y , c5 o.cJ QnJTfloc, Insulation Drywall Nailing Firewall Fire Sprinkler ( Sw.evc- - y 1 ��� �. Fire Alarm Susp'd Ceiling Roof Misc: Final SS ART FAIL M BING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin �/ Fire Supply Line [ ] Please call for reinspection RE: / [ ] Unable to inspect - no access ADA Approach /Sidewalk Date �'�� � Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 99 24 -Hour Inspection Line: 639 -4175 Business Li : 639 -4171 I o BUP Date Requested "►/1 D /00 AM PM BLD Location (� W l Suite MEC Contact Person eetAi Ph - 20 - 1 27/ PLM Contractor Ph SWR ILDI c Tenant/Owner ELC Retaining Wall ELR •o in. Access: oundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Ina Sheath /Shear Framing 1 n �/ �, �C.�l , G� v - � J �•��C Insulation � Drywall Nailing `� `--�! }Z� � ^S (� ^ • Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAI PLUMBING Post & Beam Under Slab • Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Fina P• F• I SIT Backfill /Grading Sanitary Sewer 0 , Storm Drain b v ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin N [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line ADA (� A. •reach /Sidewalk ` .t p Inspector �� cJ C Ext 9 ate anal PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST .c2D -- 0,0099 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 . BUP 2'o& 4u Date Requested AM PM BLD Location 8 9 g w /1y/A- 4-41 Suite MEC Contact Person 12//it Ph 909 PLM Contractor Ph SWR too - f -69 '2_® BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ft SGN ravel orairr Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof ' Misc: Fina PART FAIL Post & Beam Under Slab Top Out •' ater - . — "am Drai Final PART FAIL IV11 CHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA j/ 6 - Approach /Sidewalk Date L "[ 6 Inspector ° . Ext / Other Final PASS PART FAIL 0 NO REMOVE this inspection record from the job site.