Permit CITY TIGARD MECHANICAL PERMIT PERMIT #: MEC2000 -00064 �� DE SERVICES DATE ISSUED: 2/29/00 13125 SW Hall Blvd., Tigar OR 97223 (503) 639 -4171 PARCEL: 1S136AD -01800 • SITE ADDRESS: 06805 SW PINE ST SUBDIVISION: VILLA RIDGE ZONING: R-4.5 BLOCK: LOT: 002 JURISDICTION: TIG CLASS OF WORK: OTR FLOOR FURN: EVAP COOLERS: TYPE OF USE: SF UNIT HEATERS: VENT FANS: OCCUPANCY GRP: R3 VENTS W/O APPL: VENT SYSTEMS: STORIES: BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: DOMES. INCIN: LPG 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: REPAIR UNITS: FIRE DAMPERS ?: 30 - 50 HP: • GAS PRESSURE: 50 + HP: WOODSTOVES: FURN < 100K BTU: AIR HANDLING UNITS CLO DRYERS: FURN > =100K BTU: < =10000 cfm: OTHER UNITS: > 10000 cfm: GAS OUTLETS: 1 Remarks: Move gas meter and piping to other side of garage. Owner: FEES CARDENAS, MICHAEL H /SANDRA J Type By Date Amount Receipt 6805 SW PINE ST PRMT DEB 2/29/00 $50.00 00- 321899 TIGARD, OR 97223 5PCT DEB 2/29/00 $4.00 00- 321899. Total • $54.00 Phone: Contractor: ROSE HEATING CO 9945 NE 6TH DR PORTLAND, OR 97211 REQUIRED INSPECTIONS Gas Line lnsp Phone: 503- 283 -5183 Final Inspection Reg #: LIC 00002084 • This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0080. You m - • • • a opies of t� se rules or direct questions to OUNC by callin• 50 r� = Issue = y: ■ �i L �„ ,� iii • Permittee Signature: / Call (503) 639 -4175 by 7 :00 P.M. for inspections needed the next business day OF TIGARD Mechanical Permit Application R Plan ecd e�k # CITY »- PP Recd y f\. _ 13125 SW HALL BLVD. Commercial and Residential Date Rec'd 2 -gel -o 0 TIGARD, OR 97223 Date to P.E. (503) 639 -4171, x304 I I Date to DST Print or Type Permit # r /H 4 (✓l Incomplete or illegible applications will not be accepted Called Name of Development/Project Description Table 1A Mechanical Code Qty Price Amt Job Street Address Sulte# A) Permit Fee 16.00 Address '� - s p 11/1 t S 1) Furnace to 100,000 BTU including ducts & vents see footnote 1,2 9.65 Bldg# City/State Zip 2) Furnace 100,000 BTU+ - ri 6 arc ''7223 including ducts & vents see footnote 1,2 12.00 Name (or name of business) ,t 1 " 3) Floor Furnace Owner 1M A 1 ( \ L� 14 l' CAP d-e1 ' �¢ including vent see footnote 1,2 9.65 "' J - 4) Suspended heater, wall heater Mailing Address or floor mounted heater see footnote 1,2 9.65 6 i'o S' Si,/ P I v1 t 5 > 5) Vent not included in appliance permit 4.75 City /State -- op Zip Phone Check all that apply: 'Boiler Heat Air TI c n c k J c� , 9 3 (j c-sst For items 6 -10, see or Pump Cond Qty Price Amt Name (or name of business) footnotes 1 , 2 Comp 6) <3HP;absorb unit to 100K BTU 9.65 Occupant Mailing Address 7) 3-15 HP;absorb unit 100k to 500k BTU 17.65 City/State Zip Phone 8) 15 HP; absorb unit .5-1 mil BTU 24.15 9) 30-50 HP; absorb Contractor ( me _ 1 unit 1 -1.75 mil BTU 36.00 6 l /� L o� � 10) >50H absorb unit Prior to permit M I Adders ` I G / �1. >1.75 mil BTU 60.15 issuance, a copy _ `J �V C. UJ 2 � 11 Air handling unit to 10,000 CFM of all licenses py /State Zip Phone 7.00 are required if I-' % C..7) 0(2- 9 7,94 I AK 3--- 543 12) Air handling unit 10,000 CFM+ expired in COT or000n Const. Cont. Board Lic.# Et7 D 11.75 database gy _ 13) Non - portable evaporate cooler Architect Name 7.00 14) Vent fan connected to a single duct 4.75 or Mailing Address 15) Ventilation system not included in • appliance permit - 7.00 Engineer City /State Zip Phone 16) Hood served by mechanical exhaust 7.00 - Describe work to be done: 17) Domestic incinerators 12.00 New 0 Repair 0 Replace with like kind: Yes O No O 18) Commercial or industrial type incinerator Residential 0 Commercial 0 48.25 19) Repair units Additional information or description of ork: i 8.40 0`L�_ 20) Wood stove /gas FP /other units /clothe dryer /etc. y \ �`� JAI `� �l 7.00 NOTE: For Comme projects only; Units over 400 lbs. r • uire ' 21) Gas piping one to four outlets structural gas calcs. 0' r ± ' See footnote 1 • 1 3.75 Type of fuel: oil 0 natural gas LPG 0 electric •' • 22) More than 4 -per outlet (each) .75 Minimum Permit Fee $50.00 SUBTOTAL 6 I hereby acknowledge that I have read this application, that the information $ JI% SURCHARGE !J• o v given is correct, that I am th % ner o : ••" orized agent of PLAN REVIEW 25% OF SUBTOTAL the owner, that pla . su • 'red - «•m • ce with Oregon State laws. Required for ALL commercial permits only TOTAL s4 Sig . • • • . • g- . D • �f • . a q , Q G Other Inspections and Fees: // 1. Inspections outside of normal business hours (mininum charge -two C • tact Pe - on Name Phone hours) $50.00 per hour i; C 01 2. Inspections for which no fee is specifically Indicated (minimum 4 // charge -half hour) $50.00 per hour Foonotes for commercial projects only: 3. Additional plan review required by changes, additions or revisions to 1. Provide full schematic of existing and proposed gas line and pressure. , plans (minimum charge - one -half hour) $50.00 per hour 2. Provide drawings to scale showing existing and proposed mechanical units. 'State Contractor Boiler Certification required "Residential NC requires site plan showing placement of unit I:Unechperm.doc rev 02/4/99 (TO - 39/ g?7 03/03/2000 Activities for Case #: MEC2000 -00064 11:34:41 AM Assigned - Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MECA007 Application received 02/29/2000 DEB DONE No Hold DEB 02/29/2000 MECA008 Create Permit - 02/29/2000 DEB DONE No Hold DEB 02/29/2000 MECA705 Gas Line Insp 03/01/2000 KBS FAIL No Hold AKJ 03/01/2000 no one home MECA799 Final Inspection No Hold DEB 02/29/2000 MECA060 (F) Issue permit 02/29/2000 DEB DONE No Hold DEB 02/29/2000 MECA705 Gas Line lnsp 03/02/2000 KBS PASS No Hold AKJ 03/02/2000 MECA799 Final Inspection 03/02/2000 KBS PASS No Hold AKJ 03/02/2000 MECA800 Case Finaled 03/02/2000 AKJ DONE No Hold AKJ 03/02/2000 Page 1 of 1 • CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 3 AM BLD Location CD tOS b' I nO S`}: Suite 9-GOC) OO& y Contact Person m ki14G(Je.e Ph (9),(-1--sqL1 I PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam .,b Ext Sheath /Shear -�� Int Sheath /Shear Framing Insulation Drywall Nailing )/ tie o^ e6" Aver.' L Ark Le: C cC= l Firewall Fire Sprinkler 2I9 Z ( 4 4 2-4-4t ) Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL ` I CHANIC L Post & Beam Rou h In as in Smo a Dampers Final PASS PART (FAII ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date — 3 — l -- O © Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested L �- dv AM PM BLD Location CO g1) .' / ? 44te Suite MEC o20.0 C)e Contact Person Ph PLM Contractor Ph SWR BUILDING Tenant/11M�L� _/ (�J/ i -� ELC Retaining Wall id!) ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: /� Slab /H /s -�� / ,a4f(4 SIT Post Sheath/Shear Beam Ext Sh % � � �r�� ► �lf LU ( GU / %C.1/l Int Sheath /Shear Framing lJ � ,LGC- ' 4/0 O Insulation Drywall Nailing Firewall � / / / . / Fire Sprinkler I . 4/L 3 ! co . ✓ Fire Alarm ' ` Susp'd Ceiling 41-4 :� _ , L/ _1.:L' — 4e/ J. Roo C4,O Gr A ��% � Final PASS PART FAIL p PLUMBING ( ./J 4 . v� %lL,li('D 8:13 e #4 41. Post & Beam Under Slab f f2/1-4.49.-Z � 7 . - , `Yer Top Out Water Service Sanitary Sewer Rain Drains Q4 1 &t S ^? r . TS z = 30 � r o/c-- Final > l PASS PART FAIL /S l/�fi� �vT�S C�l� $� l 4 3 8CE ) 75—__ MECHANICAL Post & Beam Rough In (Gas l S oke Dampers PART FAIL ELEC AL Service Rough In 1� UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other D '1 Inspector ' Ins r Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.