Permit CITY OF TIGARD
_ i DEVELOPMET SERVICES PERMIT #ERMIT MST96- O,?,87
Tigard, ) DATE ISSUED: 11/27/96
PARCEL: 1S136CC -CH001
SITE ADDRESS...: 08286 SW PFAFFLE ST
SUBDIVISION • CARRIAGE HOUSE APARTMENTS ZONING: R -12
BLOCK • LOT •
Remarks: Multi- family 8 unit apartment complex with attached garage
- - - -- - — BUILDING -
REISSUE: STORIES • 2 FLOOR AREAS -- BASEMENT...: 0 sf REQUIRED SETBACKS — REQUIRED —
CLASS OF WORK.:NEW HEIGHT • 0 FIRST : 3572 sf GARAGE • 1293 sf LEFT : 0 SMOKE DETECTRS: Y
TYPE OF USE...:MF FLOOR LOAD • 0 SECOND...: 3572 sf FRONT • 0 PARKING SPACES: 1
TYPE OF CONST.:5N DWELLING UNITS: 8 FINBSMENT: 0 sf RIGHT • 0
OCCUPANCY GRP.:R1 BDRM:16 BATH: 0 TOTAL------: 7144 sf VALUE..$: 479248 REAR • 0
- — PLUMBING --
SINKS • 8 WATER CLOSETS.: 16 WASHING MACH..: 8 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS • 0
LAVATORIES • 16 DISHWASHERS...: 8 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 0 CATCH BASINS..: 0
TUB /SHOWERS...: 16 GARBAGE DISP..: 8 WATER HEATERS.: 8 WATER LINE ft: 0 BCKFLW PREVNTR: 0 GREASE TRAPS..: 0
OTHER FIXTURES: 0
— — MECHANICAL —
FUEL TYPES -- FURN ( 100K ..: 0 BOIL /CAP ( 3HP: 0 VENT FANS • 8 CLOTHES DRYERS: 0
/ELC/ / / FURN )= 1 ..: 0 UNIT HEATERS..: 0 HOODS • 0 OTHER UNITS...: 8
MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 16 WOODSTOVES • 0 GAS OUTLETS...: 0
-- -- ELECTRICAL -- ------------------ ------
- -RESIDENTIAL UNIT— — SERVICE /FEEDER --- —TEMP SRVC /FEEDERS— --BRANCH CIRCUITS -- ---- MISCELLANEOUS — — ADD'L INSPECTIONS- -
1'w SF OR LESS: 8 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500SF.: 0 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0
LIMITED ENERGY.: 0 401 - 6w• amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT : 0
MANF HN /SVC /FDR: 0 601 - 1'•'' amp.: 0 601+amps- 1'-'•r% v: 0 MINOR LABEL -10: 0
1000+ amp /volt.: 0 - ---- PLAN REVIEW SECTION — — --
Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC:
— - ELECTRICAL - RESTRICTED ENERGY — — --
A. SF RESIDENTIAL- -- B. COMMERCIAL - ---- --- - - --
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: 0TH: .• BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL • OTHR: ..
HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0
Owner: ----------------------- Contractor: - TOTAL FEES:$ 9575.70
ANDREWS MANAGEMENT LTD NCH CONSTRUCTION CO
4m SW KRUSE WAY #270 COLUMBIA EQUITIES INC
8235 SW OLESON RD STE C
LAKE OSWEGO OR 97035 PORTLAND OR 97223
Phone 8: 699 -8645 Phone 8: 224 -7410
Reg 8..: 049267
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore., Specialty Codes and all other
applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180
days of issuance, or if work is suspended for more than 180 days.
--- - - - - -- — -- REQUIRED INSPECTIONS ---- -- --
Footing Insp Post /Beam Mechan Electrical Servi Framing Insp Shear Wall Insp Water Service In
Foundation Insp Plm /Underfloor Electrical Rough Fireplace Insp Firewall Insp Appr /Sdwlk Insp
Erosion Control Crawl Drain Mechanical Insp Gas Line Insp Gyp Board Insp Sprinkler Underf
Wtr Proofing Bsm Slab Insp ' umbing Top Out Gas Fireplace Rain Drain Insp Sprinkler Rough -
Past /Beam Struct Plm /undslb In . L. Voltage / Insulation Insp Wa Line Insp Additional
Per �` Issued B
mittee Signature: ., y:4----..
Call for inspection - 639 -4175
Commercial Building Permit Application 7
. o1 Tigard
13125 SW Hall Blvd. k 4
Tigard, OR 97223
ill 13 . b
(503) 639 -4171 BUILDING D7 f v 1 1� L
SW PFAFFLE & 83RD
WCTM 1S1 36CC WL-Ivvti-S
�� OA Lt i2 11-2 7-1
Jobsite Address: TAX LOTS 200, 300, 2000 L�Q l
4,2...z-6( s“..) PEA It. :
n Office Use Only ::`: :.: „. ::
Tenant :( A (An 4t 1, At- Suite # :
Valuation: (1 40:, . " • �, _ �, Planck/Rec #. 7 ` S.: � (y
d 9 L/ 71, ,2Y�' ,. P erm it 7 No Q om : fA {Z gb _ ps -- 3 '
Owner: Andrews Management, Ltd.
Map &: TL # 1 S1 3toCC - 1- 20
Address: 4000 Kruse Way Place, Bldg 1, #270
Abprovals `;::':
Lake Oswego, OR 97035
Planning
Phone: (503) 699-8645 , - ::
Engineering
: .:.Other
MCH Construction
Contractor: ..
i- A- lu101 7/9y Dec.. _ a, 72
Address: 8235 SW Oleson Road, Suite C f f aye A Li 0
C,4 6ZA 6 r - 12')
Portland, Oregon 97223 Type of const: 907 /(
Occupancy class: R1 per _
Phone: (503) 244 -0523
Sprinklered? Yes No
Contractor's License # 49267 Apr GA R
(attach copy of current Oregon license) Sq. ft. of project: 7,1444- I,g = V-734
Contact name & phone: Phil McHugh (503) 244 -0523 Story (1st, 2nd, etc.) 2
Proposed use: Multi Family/C
Architect/Engineer: P. Rowell /R. G. Naff r 1-¢ . LC' _ a .(
Previous use: Vacant Land ti
Address: 18641 SW Benfield Avenue �,/,
Note: Plumbing & mechanical plans
Lake Oswego, OR 97035 must be submitted at time of
Phone:
(503) 639 -8045 building permit application.
JOB DESCRIPTION: 2 Story light frame wood construction
-- 1Z:e 1) M .--- t ri- e) 6 A.3
Applicant Signature & Phone nu e
Received by: Lk Date Received: 7 lz-2-
I
Permit # Account Description Amount Amt. Pd. Bal. D
nU 9 _0 3t7 Bldg. Permit (BUILD) /3 ?3. /3857 „
= Plumb. Permit (PLUMB) 79z. 7qi .,-
Mech. Permit (MECH) / / S / 1 g v
State Tax (TAX) 15 1 S g .616
Bldg: �r� z Et.�l $�D r,,PPy, $ctv
Plumb: 3i-Go
Mech: S . 1 0
CLE:. . / ___- ._,
Plan Check (PLANCK) SIC.15 1 5,51
Bldg: . 9 C
Plumb: IQ ff ad • rL fr1? -I� Vi °
Mech: (7 M'EC-PLI1 Z —� ✓
p -�� E.LE ' Zi__ _ - - — -�' EL1L k& 7-40 SUO F 6 i 1 -- tip 1 f Sewer Connection (SWUSA) ( -6- QO
Sewer Inspection (SWINSP)
Parks Dev Charge (PKSDC) 4/320i. 1/4/32-0,-
. A. 1 'Pk uv Residential TIF (TIF -R) 1 1 to 12- p-c-pr('A ' - 7 ) ( Z✓
47 1 l ea u WL Mass Transit TIF (TIF -MT) -7(o .1
57C ,/
Commercial TIF (TIF -C)
Industrial TIF (TIF -I)
Institutional TIF (TIF -1S)
Office TIF (TIF -0)
Water Quality (WQUAL)
Water Quantity (WQUANT)
Fire Life Safety (FLS) S53. ZU 4- 7/, i
Erosion Cntrl Permit (ERPRMT) /34. /3
Erosion Planck/USA (ERPLAN) il y. 2.0 U-1. Z v
Erosion Planck/COT (EROSN) 0 U • Zv Citi• 7 v
TOTALS: Z7 115,10 1 a 1p� r ( / -� !P”2--
1
Community Development ELECTRICAL PERMIT APPLICATION
13125 SW Hall Blvd.
Tigard, OR 97223 Planck/Rec. #
; , No,. 1 , Permit # MST 1 - ? 1
' I Phone (503) 639 -4171
-� `�'` � I " Date Issued
FAX (503) 684 -7297
CITY OF TIGARD TDD No. (503) 684 -2772 Issued by
Inspection (503) 639 -4175
1. Job Address: ��nn 4. Complete Fee Schedule Below:
Nasrt pf Development CL A421U AGE _ Number of Inspections per permit allowed
Address Su) i I e- Service included: Items Cost(ea) Sum
City /State/Zip ...- 1 - 142... 4a. Residential - per unit � 4
1000 sq. ft. or less $110.00 U
Name (or name of business) b .` Each additional 500 sq. ft. or isb
portion thereof $25.00 1 - Commercial ❑ Residential ❑ Limited Energy $25.00
Each Manuf'd Home or Modular 2
Dwelling Service or Feeder $68.00
2a. Contractor installation only:
4b. Services or Feeders
Installation, alteration, or relocation 2
Electrical Contractor ii . A kt j, r . . , . ' .ii_ - 200 amps or less $60.00 2
•df SS , 'lZie `nII 201 amps to 400 amps $80.00 2
- Cil m��.1�) G StateO Zip Q 7 � 401 amps to 600 amps - 601 amps to 1000 am $120.00 2
ps $180.00 2
r -
Phone No. _ �- / -_ 3 Over 1000 amps or volts $340.00 2
Contractor's License No. (p- / 1 7 4 yG Reconnect only $50.00
Contractor's Board Reg. No. r' oq 4c. Temporary Services or Feeders
Installation, alteration, or relocation 2
, Signature of Sup r. �E/�lllec'n / 200 amps or less $50.00 2
License No, �'/ v G S D Phone . RAI -Fj?1 9 ` 201 amps to 400 amps $75.00 2
-
401 amps to 600 amps $100.00
Over 600 amps to 1000 volts
2b. For owner installations: see - b• above.
Print 4d. Branch Circuits
rint Owner's Name
New, alteration or extension per panel
Address a) The fee for branch circuits with
City State Zip p of circuit or feeder fee. $5.00 2
i 1 : Phone No. b) The fee for branch circuits without
The installation is being made on property I own which is purchase of service or feeder fee. 2
not intended for sale, lease or rent. First branch circuit $35.00 2
Each additional branch circuit $5.00
Owner's Signature 4e. Miscellaneous
(Service or feeder not included) 2
3. Plan Review section (if required): Each pump or irrigation circle $40.00 2 - Each sign or outline lighting $40.00
Signal circuit(s) or a limited energy 2
Please check appropriate item and enter fee in section 5B. panel, alteration or extension $40.00
4 or more residential units in one structure Min Labels (10) $100.00
-
Service and feeder 225 amps or more
System over 600 volts nominal 4f. Each additional inspection over
Classified area or structure containing special occupancy the allowable in any of the above
as described in N.E.C. Chapter 5 Per inspectio $35.00 -
Per hour $55.00
In Plant $55.00
Submit 2 sets of plans with application where any of the above
apply. Not required for temporary construction services. 5. Fees:
NOTICE 5a. Enter total of above fees $ 4 1112#4. 0 .. (7
5% Surcharge (.05 X total fees) $
PERMITS BECOME VOID IF WORK OR CONSTRUCTION Subtotal $
AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF Sb r yD �-
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR Plan Review if required (Sec.3)�� $
A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS Subtotal $
COMMENCED. ❑ Trust Account # $
Balance Due $ (
.mefoomd 4.l.ro,m.app
City of Tigard MECHANICAL PERMIT Planck/Rec. #
13125 SW Hall Blvd. APPLICATION Permit # MT' , (o 7
Tigard, OR 97223
•
(503) 639 -4171 711/\\ h
Name of Development Descnption
BUILDIII D7 - CARRIAGE ILXJSE APLS Table 3A Mechanical Code QTY PRICE AMT
Add°°°
Job SW PFAFFLE & 83RD - '6256,(D p-V-k 1 \e 1) Permit Fee -0- -0- 10.00
Address cWStai.
WCIM 1S1 36CC Tax rats 200,300,2000 2) Supplemental Permit 3.00
Name (a name or busmen) Furnace to 100,000 BTU
Andrews Management, Ltd (503) 699 -8645 1) incl. ducts & vents 6.00
MarmAddea° Phone Furnace 100,000 BTU +
Owner 4000 Kruse Way Place Bldg 1 #270 2) incI. ducts & vents 7.50
aa,rsew DO Floor Fumance
Lake Oswego OR 97035 3) incl. vent 6.00
Name i° name of busmen) Suspended heater, wall heater
4) or floor mounted heater 6.00
Ma'm, mesas man. Vent not Incl. in
Occupant 5) appliance permit 16 3.00 48.00
cdpae4 zo Repair of heating, refrig.
6) cooling, absorption unit 6.00
Nee° Boiler or comp, heat pump, air cond.
M C H Construction ( 503) 244- 0523 7) to 3 HP; absorp unit to 100K BTU 6.00
Mamp A°ae'a Amu Boiler or comp, heat pump, air cond.
Contractor 8235 SW Oleson Rd Ste C 8) 3-15 HP; absorp unit to 500K BTU 11.00
�` r4 Boiler or comp, heat pump, air cond.
/ R
Portland, OR 97223 9) 15-30 HP; absorp unit .5-1 mil BTU 15.00
l ` O
State N° No �° Tea No Boiler or comp, heat pump, air cond.
49267 10) 30-50 HP; absorp unit 1 -1.75 mil BTU 22.50
I h e y acknowledge that I have read this application, that the Boiler or comp, heat pump, air cond.
information given is correct, that I am the owner or authorized 11) > 50 HP; absorp unit 1.75 mil BTU 37.50
agent of the owner, that plans submitted are in compliance with Air handling unit to
State laws, that I am registered with the Construction Contractor's 12) 10,000 CFM 4.50
Board, that the number given is correct. (If exempt from State Air handling unit
registration, please give reason below.) 13) 10,000 CTM + 7.50
Non portable
14) evaporate cooler 4.50
Vent fan connected L
15) to a single duct . U 3.00 0.
Ventilation system not
16) included in appliance permit 4.50
mrature (owner or agent) Date Hood served by
17) mechanical exhaust 4.50
Describe work new Q;) addition 0 alteration 0 repair 0 Commercial or industrial
to be done residential Q non - residential 0 18) type incinerator 30.00
Existing use of Vacant Land Other i.e., woodstove, water
building or property 19) heater, solar, clothes dryers, etc. 8 4.50 36.00
Proposed use of Multi Family 20) Gas piping one to four outlets 2.00
building or property
21) More than 4 -per outlet (each) 2.00
Type of fuel - oil Q natural gas 0 LPG 0 electric
NOTICE _
(r
Minimum Fee $25.00 SUBTOTAL / 9' 0
PERMITS BECOME VOID IF WORK OR CONSTRUCTION p
AUTHORIZED IS NOT COMMENCED W r WITHIN 180 DAYS, OR 5% SURCHARGE 7 9 / •' .7 1
IF CONSTRUCTION OR WORK IS SUSPENDED OR
ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME PLAN REVIEW 25% OF SUBTOTAL .Z I- 2 .0
AFTER WORK IS COMMENCED.
TOTAL l s3 _ 1 - :0
Special Conditions
Date issued by
M:1OGIMDSTSWECMPMT / •/ / /
W 'C 17 /y, -r9 ? 21 •lt V 7 et 6r (9 ../. c) / ' 1\ • 17, 4' ( 1-
To P,E, - o -/"
City of Tigard PLUMBING PERMIT APPLICATION Planck/Rec. #
13125 SW Hall Blvd. Permit # MT %ke ,1
Tigard, OR 97223 5 U(t. 7/, 7,4
(503) 639 -4171 V
MINIMUM $25.00 PERMIT FEE + ST. SURCHARGE
Name °' DeYOnoe°'m New Single Family Residences Only
BUIIDIN3 D7 - CARRIAGE HOUSE
APTS
Job SW PFAFFLE & 83RD _ CI BATH HOUSE $140.00 ❑ 2 BATH HOUSE $195.00
2-V0 5w Q-o, ke ❑ 3 BATH HOUSE $225.00
Address cuyistew Fee includes all plumbing fixtures in the dwelling and the first 100 feet
Tn1CIM 1S1 36CC Tax Lots 200, 300, 2000 of water service, sanitary sewer and storm sewer. See fees below.
Name (' Name el Duman) FIXTURES QTY PRICE AMT
Andrews Managerent, Ltd. (503)699 -8645 Sink 8 9.00 72.00
Mailing Address Phone Lavatory 16 9.00 144.00
Owner 4000 Kruse Way P1 Bldg 1 #270 Tub or Tub/Shower Comb. 16 9.00 144.00
C^'/State as Shower Only 9.00
Lake Oswego, OR 97035 Water Closet 16 9.00 144.00
Name (et name of chews) Dishwasher 8 9.00 72.00
Garbage Disposal 8 9.00 72.00
Occupant Mair, anon. Washing Machine 8 9.00 72.00
Floor Drain 9.00
city's„'. ap Water Heater 8 9.00 72.00
Laundry Room Tray 9.00
Name Urinal 9.00 .
NEE Construction Other Fixtures (Specify) 9.00
liming Adtreo Phone 9.00
Con ='or 8235 SW Oleson Rd Ste C (503)244 -0523
9.00
cdinstete re 9.00
( 1 Portland, Oregon 97223 Sewer 1st 100' 30.00
\
State Repevseen Na. City e'a. Tea No. Sewer - ea. Addit 100' 25.00
49267 Water Service 1st 100' '\ 30.00
I hereby acknowledge that I have read this application, that the Water Service ea. Addit. 200' 25.00
information given is correct, that I am the owner or authorized agent of
the owner, that plans submitted are in compliance with State laws, that Storm & Rain Drain 1st 100' 30.00
I am registered with the Construction Contractor's Board, that the Storm & Rain Drain Addit 100' 25.00
number given is correct. (If exempt from State registration, please
give reason below.) Mobile Home Space 25.00
Back Flow Prevention
Device or Anti - Pollution Device 9.00
Signature (owner or agent) Date Any Trap or Waste Not
Connected to a Fixture 9.00
Describe work new ® addition 0 alteration 0 repair 0 Catch Basin 9.00
to be done residential e non - residential 0 Insp. of Exist Plumbing 40.00/hr
Specially Requested Inspections 40.00/hr
Existing use of
building or property Vacant Land Rain Drain, single family dwelling 30.00
Residential backflow prevention
devices 15.00
Proposed use of Multi Family
building or property
'(Except residential backflow
prevention devices)
NOTICE *Minimum Fee $25.00 SUBTOTAL 792.0C
PERMITS BECOME VOID IF WORK OR CONSTRUCTION 39.6C
AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF 5% SURCHARGE
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED
FORA PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS
COMMENCED. PLAN REVIEW 25% OF SUBTOTAL 198.00
TOTAL 1,029.60
Special Conditions
Date issued by
i
•
Page No. 1 CASE HISTORY FOR CASE NO.: MST96 -0387
ANDREWS MANAGEMENT LTD
08286 SW PFAFFLE ST
01/29/98
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA723 Electrical Service / / / / 07/01/97 NOTE: CHECK LISTING FOR LAMPS, i.e., NOTE RB 07/01/97 J'H
bathroom heat lamps, exhaust /heat lamp
as per requirements for clearances to
combustibles.
MSTA725 Framing Insp / / / / 07/01/97 Chase sprinkler line in closet of #240, APP RB 07/01/97 J *H
#241, #239.
MSTA975 (F) Issue Temp Cert. of Occ / / 10/22/97 10/17/97 C/O is contingent to eng96 -0063 approval TEMP JT 10/27/97 JT
15 days temp. C/O
good through November 7
10/27/97 Rick signed, went to David for
his signature
MSTB725 Mechanical Insp / / / / 06/25/97 APPROVAL SUBJECT TO: 1. Dryer vent PASS MS 07/30/97 J *H
smashed down need to be staightened out,
8 UNITS.
MSTD005 Application received / / / / 07/27/96 RECD JH 12/02/96 JDA
MSTD008 Permit created / / / / 07/30/96 PEND BON 12/02/96 JDA
MSTD010 Check for prcl. restrict. / / / / 07/30/96 PEND BON 12/02/96 JDA
MSTD012 Plans routed to Plans Examiner / / / / 07/30/96 ROUT BON 12/02/96 JDA
MSTD015 Requested revised plans fr app / / / / 10/28/96 This is a letter to office service PASS JF 12/02/96, JDA
category
MSTD018 Revised plans submitted / / / / 11/20/96 RECD JHF 12/02/96 JDA
MSTD026 Plans approved by Plans Exmr / / / / 11/21/96 APPR JHF 12/02/96 JDA
MSTDO26 Plans approved by Plans Exmr / / / / 11/25/96 House panel on separate permit APPR MJR 12/02/96 JDA
MSTD030 Reviewed plans routed to DSTS / / / / 11/21/96 ROUT JHF 12/02/96 JDA
MSTD030 Reviewed plans routed to DSTS / / / / 11/25/96 APPR MJR 12/02/96 JDA
MSTD090 (F) Ready to issue / / / / 11/27/96 Still needs plumbing contractor before PASS BON 12/02/96 JDA
issuing. Be sure to enter Deferred TIF
amounts to fees after issuing.
MSTD098 (F) Issue combination permit / / / / 11/27/96 PASS BON 12/02/96 JDA
MSTD103 issue plumbing signature form / / / / 11/27/96 PASS BON 12/02/96 JDA
MSTD104 Issue Electric Signature Form / / / / 12/18/96 OK BON 12/18/96 RB
MSTD410 Devel review cond. met 12/02/96 / / 10/20/97 PASS JDA 10/20/97 JDA
MSTD700 Erosion Control 12/02/96 / / 06/30/97 OK RB 07/01/97 J•H
MSTD705 Footing Insp 12/02/96 / / 12/02/96 APP GS 12/03/96 GES
MSTD706 Foundation Insp 12/02/96 / / 12/05/96 D -7 units (4)ea. PASS RB 12/05/96 RB
MSTD709 Wtr Proofing Bsm't Walls 12/02/96 / / / / 12/02/96 JDA
' *Page No. 2 CASE HISTORY FOR CASE NO.: MST96 -0387
ANDREWS MANAGEMENT LTD
08286 SW PFAFFLE ST
01/29/98
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
---- - -- ------ -- ---
MSTD710 Post /Beam Structural 12/02/96 / / 01/22/97 pending- clear low point drains; dry PASS RB 01/23/97 RB
pack thru penetrations in firewalls;
structural beams missed at storage
areas- for decking support.
MSTD712 Plm /Underfloor 12/02/96 / / 01/21/97 PASS MS 01/21/97 MRS
MSTD713 Crawl Drain 12/02/96 / / 12/17/96 not installed NR MS 12/18/96 MRS
MSTD715 Slab Insp 12/02/96 / / 12/13/96 pending- garage slab- approved D -7 Units PASS RB 12/13/96 RB
water holding w /in footing of
dwellings- low point drains req'd
MSTD717 Underfloor insulation / / / / 02/10/97 place insulation to warm side PASS RB 02/10/97 RB
MSTD723 Electrical Service 12/02/96 / / 06/25/97 PASS BRP 06/27/97 J *H
MSTD724 Electrical Rough -in 12/02/96 / / 06/25/97 PASS BRP 06/27/97 J *H
MSTD725 Mechanical Insp 12/02/96 / / 06/30/97 Secure heat lamp in bathroom, Unit 140. PART RB 07/01/97 J *H
MSTD725 Mechanical Insp / / / / 06/25/97 HOOD /DUCT & VENTING: Approved subject to PASS MS 07/30/97 J *H
correction: Dryer vent smashed down,
needs to be staightened out.
MSTD727 Low Voltage 12/02/96 / / 09/15/97 PASS MJR 09/16/97 MJR
MSTD729 Plumbing Top Out 12/02/96 / / 06/16/97 PASS RAB 06/18/97 J *H
MSTD730 Framing Insp 12/02/96 / / 06/25/97 1. Fill holes in fireblocking FAIL RC 06/27/97 JDA
2. Patch holes in exterior sheetrock
3. Need block under valley rafter
4. Pill holes in firewall with
appropriate material
MSTD745 Insulation Insp 12/02/96 / / 06/27/97 FAIL RC 06/29/97 J *H
MSTD750 Shear Wall Insp 12/02/96 / / 06/24/97 NAILS OVERDRIVEN, NEED CHANGE FROM FAIL RC 06/26/97 J *H
ENGINEER FOR CHANGE TO GYP BD SHEAR WALL
ON 2ND FLOOR.
MSTD755 Firewall Insp 12/02/96 / / 06/06/97 PARTIALLY APPROVED PENDING CORRECTIONS PASS RB 06/07/97 J *H
OF NAILING NO GREATER THATN 1 -IN. AWAY
FROM EDGE OF GYPSUM BOARD.
MSTD755 Firewall Insp / / / / 07/02/97 APPROVED PENDING: Fire tape where joints PASS RB 07/07/97 J *H
are too close to off -set in vertical
walls. Nail bottom edge lower floor.
Close off sprinkler in closet at far end
(south).
MSTD755 Firewall Insp 07/30/97 / / 07/08/97 1 -HR FIREWALL FINAL, DRYWALL NAILING PASS RB 07/30/97 J *H
APPIW
�
Page No. 3 J ', . . A1GARt' CASE HISTORY FOR CASE NO.: MST96 -0387
s
C A A , ANDREWS MANAGEMENT LTD
06286 S W PFAFFLE ST
01/29/98 B I
Title ,
Action Description eq/ Schd/ End/ Action Notes Disp By Update Upd
Code ent Done Done Date By
Date ■■
MSTD755 Firewall Insp 07/30/97 / / 07/08/97 2 -HR FIREWALL FINAL DRYWALL NAILING PASS RB 07/30/97 J *H
MSTD760 Gyp Board Insp 12/02/96 / / 06/06/97 1. 1 -hr tub walls need additional PASS RB 06/07/97 J *H
nailing and fire tapping where lacking
behind stud supports.
2. 2 -hr (1st layer) okay
MSTD760 Gyp Board Insp / / / / 07/08/97 Inspected unite 140, 139, 142, 141, 241, FAIL RB 07/08/97 J *H
240
Unable to inspect units 242, 239 (due to
no safe entry)
1. Missed nailing (marked where missed)
•
2. Replace white board with green board
where misplaced.
MSTD775 Rain Drain Insp 12/02/96 / / 12/17/96 around bldg ok PART MS 12/18/96 MRS
MSTD780 Water Line Insp 12/02/96 / / 02/07/97 TVW service area PASS MS 10/20/97 J *H
MSTD781 Water Service Insp 12/02/96 / / 02/07/97 PASS MS 10/20/97 J *H
MSTD785 Appr /Sdwlk Insp 12/02/96 / / / / Will be done with engineering permit. N/A 10/17/97 J *H
MSTD789 Smoke Detector 12/02/96 / / / / 12/02/96 JDA
MSTD796 Electrical Final 12/02/96 / / 09/15/97 PASS MJR 09/16/97 MJR
MSTD797 Plumb Final 12/02/96 / / 09/05/97 PASS RAB 09/11/97 J *H
MSTD798 Mechanical Final 12/02/96 / / 10/16/97 See building final this date FAIL RB 10/17/97 J *H
MSTD799 Building Final 12/02/96 / / 10/16/97 3. Unit 140, 2nd bedrm smoke detector FAIL RB 10/20/97 J *H
not working, interconnection needed.
Dryer venting plugged.
4. Land use issues still unresolved.
• 6. Water line /service approval from TVW
required.
MSTD799 Building Final / / / / 10/17/97 Contingent upon approval of ENG96 -0063, PASS RB 01/29/98 JT
engineering & public improvements and
SDR96 -0007, land use.
^ By review, Leatba Thomas approved issues
\J\ as per her responsibility.
4 1/29/98 TO JILL FOR C/O APPROVAL
S
CITY OF TIGARD BUILDING INSPECTION DIVISION
24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171
Date Requested: 1 Q + i 2— 7 7 A.M. P.M. MST:W (7✓ ( F7
'i Location: O ,9 (p /, )/k P-4 Fat BUP:
\\
Tenant: Suite: (� Bldg: 1/ MEC:
Contractor: l ' t \f\G Phone: 649 a g15 ( PLM:
Owner: 7 Phone: ELC:
ELR:
■•■ SIT:
BUILDING ; 0 1 G co , 't) PLUMBING L - AL ELECTRICAL SITE
Site 'o 1 : • : s Post/Beam Post/Beam Cover /Service Sewer /Storm
Footing Roof UndFl/Slab Rough -In Ceiling Water Line
Slab Framing Top Out Gas Line Rough -In UG Sprinkler
Foundation Insulation Sewer Hood/Duct Reconnect Vault
Bsmt Damp Drywall Storm Furnace Temp Service MISC.
Masonry Ceiling Rain Drain A/C UG Slab
Shear /Sheath Fire Spklr /Ahn Crawl/Found Dr Heat Pum. Low Volt
C'Approved Approved Approved Approved
Appr /Sdwlk Not Reproved Not Approved Not :1:.. ed Not Approved Not Approved
FINAL IN FINAL F
c ., AL
3 N q 6 00 (g`3 5D 2-q 19-6d o i) Lei( 'l c, — erva a r
∎ 'V� /� t� Yyl _ g7
51.1-r 9 -V 42-- p7:_th 1 i Sc -
L., ,-,k, .„., .
h. . / A. n •
•
x (.......6
Call for reinspection O Reinspection fee of $ req ' ed before next inspection O Unable to inspect
Inspector: I J gg �� k_. C../..) Date: 1 V ) 4 Page of