Correspondence Ale e la - CO RE 7 .l .7 'S 1 l y Dan Nelson From: Hettervig, Paul <phettervig @pmc- g.com> Sent: Thursday, May 24, 2012 11:04 AM To: Dan Nelson Subject: RE: Plan review for Burgerville Hood Attachments: Burgerville Tigard- Drawings - SHOP.PDF • Dan Attached are the shop drawings. The hood O &M is found here, which has detailed instruction on hanging the hood. The grease duct O &M is found here, which has detailed instruction installation. The grease duct is ETL listed under file number 1000082319SAT -006 EEV and complies with UL 1978 and UL 2221 standards. If there are any questions, don't hesitate to respond. Please let me know if this is acceptable or if you need anything else. Thanks, Paul. Paul Hettervig Sheet Metal Division Manager Plumbing Mechanical Contractors Group. 2000 SE Hanna Harvester Dr Milwaukie, Or 97222 PH# 503 - 656 -7400 Cel# 503 - 804 -6569 Fax# 503 - 655 -0620 • From: Dan Nelson jmailto:DanNC�tigard- or.govl Sent: Thursday, May 24, 2012 9:48 AM To: Hettervig, Paul Subject: Plan review for Burgerville Hood • Dan Nelson Senior Plans Examiner City of Tigard • dannC tigard- or.gov (503)718 -2436 F(503)624 -3681 • • DISCLAIMER: E -mails sent or received by City of Tigard employees are subject to' public record laws. If requested, e-mail 1 RE: COMMERCIAL EXHAUST HOODS r I �� � rrF._ce V1G Project Information • Building Permit: MEC2012 -00269 Occupancy Type: A -2 Tenant Name: Burgerville Construction Type: 5B Address: 12785 SW Pacific Hwy. Stories: 1 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2010 edition and The Oregon Fire Code 2010 edition. The following corrections need to be submitted for review prior to issuing of the permit. 1) Please provide drawings showing connection of hood to structure. 2) Please provide connection details of makeup air unit on roof. 3) Provide listing and installation instructions for grease duct. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson, Senior Plans Examiner (503) 718 -2436 dann @tigard - or.gov • RE: COMMERCIAL EXHAUST HOODS Project Information Building Permit: MEC2012 -00269 Occupancy Type: A -2 Tenant Name: Burgerville Construction Type: 5B Address: 12785 SW Pacific Hwy. Stories: 1 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2010 edition and The Oregon Fire Code 2010 edition Ducts exposed to the outside atmosphere shall be protected against corrosion in an approved manner. 506.2 OMSC A Performance Test shall be conducted upon completion and before final approval of the installation of the ventilation system. The performance test shall verify the rate of airflow to be in compliance with the approved plans. 507.17 OMSC The exhaust and make -up air system shall be electronically interlocked to ensure that the make -up air is provided whenever the exhaust system is in operation. 508.1 OMSC An automatic fire suppression system shall be provided to protect the surface of the heat - processing appliances and the exhaust system serving the appliances. 509.2 OMSC Ductwork shall be supported in accordance with Sheet Metal & Air Conditioning Contractors National Association, Inc. (SMACNA) Appliances shall be accessible for inspection, service, repair or replacement without removal of permanent construction. 306.1 OMSC Appliances installed on roofs or elevated structures exceeding 16 feet in height shall be provided with a permanent means of access grade or floor level. 306.5 OMSC Condensate from cooling coils or evaporators shall be collected and discharged to an approved plumbing fixture or disposal area. 307.1 OMSC Exhaust fan mounting An upblast fan shall be hinged and supplied with a flexible weatherproof electrical cable to permit inspection and cleaning. The ductwork shall extend a minimum of 18 inches (457 mm) above the roof surface. OMSC 506.5.3 Supports Type I hoods shall be secured in place by noncombustible supports. All Type I and Type II hood supports shall be adequate for the applied load of the hood, the unsupported ductwork, the effluent loading, and the possible weight of personnel working in or on the hood. OMSC 507.6 • Compensating hoods Manufacturers of compensating hoods shall provide label indicating minimum exhaust flow and /or maximum makeup airflow that provides capture and containment of the exhaust effluent. OMSC 508.2 • All deep -fat fryers shall be installed with at least a 406 mm (16 in.) space between the fryer and surface flames from adjacent cooking equipment. 12.1.2.4 • Where a steel or tempered glass baffle plate is installed at a minimum 203 mm (8 in.) in height between the fryer and surface flames of the adjacent appliance, the requirement for a 406 mm (16 in.) space shall not apply. 12.1.2.5 When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. ;. • Respectfully, Dan Nelson, Senior Plans Examiner (503) 718 -2436 dann @tigard - or.gov •