Permit •
CITY OF 13IGARD MASTER P
/ �,a, „ DEVELOPMENT LOPMEN SERVI PERMIT #ERMIT MST9E, -0385
+'mot DATE ISSUED: 11/27/96
PARCEL: 1S13ECC —CH001
SITE ADDRESS...: 08332 SW PFAFFLE ST
SUBDIVISION • CARRIAGE HOUSE APARTMENTS ZONING: R -12
BLOCK • LOT °
Remarks: Multi - family 12 unit apartment complex
— - -- BUILDING ---- -- --
REISSUE: STORIES • 2 FLOOR AREAS BASEMENT...: 0 sf REQUIRED SETBACKS -- REQUIRED--- -
CLASS OF WORK. :NEW HEIGHT 0 FIRST • 4824 sf GARAGE • 0 sf LEFT • 0 SMOKE DETECTRS: Y
TYPE OF USE...:MF FLOOR LOAD 0 SECOND...: 4824 sf FRONT : 0 PARKING SPACES: 0
TYPE OF CON.5T.:511 DWELLING UNITS: 12 FINBSMENT: 0 sf RIGHT 0
OCCUPANCY GRP.:R1 BDRM:20 BATH: 0 TOTAL : 9648 sf VALUE..$: 616663 REAR 0
PLUMBING -------------- ---- —
SINKS • 12 WATER CLOSETS.: 20 WASHING MACH..: 12 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS • 0
LAVATORIES • 20 DISHWASHERS...: 12 FLOOR DRAINS..: 0 . SEWER LINE ft: 0 SF RAIN DRAINS: 0 CATCH BASINS..: 0
TUB /SHOWERS...: 20 GARBAGE DISP..: 12 WATER HEATERS.: 12 WATER LINE ft: 0 BCKFLW PREVNTR: 0 GREASE TRAPS..: 0
OTHER FIXTURES: 0
— MECHANICAL
FUEL TYPES- FURN ( 100K ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS • 12 CLOTHES DRYERS: 0
/ELC/ / / FURN > =100K ..: 0 UNIT HEATERS..: 0 HOODS • 0 OTHER UNITS...: 12
MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 20 WOODSTOVES....: 0 GAS OUTLETS...: 0
- -- — ELECTRICAL --
- RESIDENTIAL UNIT— — SERVICE /FEEDER— —TEMP SRVC /FEEDERS— -- BRANCH CIRCUITS— — MISCELLANEOUS - -- — ADD'L INSPECTIONS- -
1m SF OR LESS: 9 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500SF.: 0 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FOR: 0 . SIGN /OUT LIN LT: 0 PER HOUR : 0
LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT : 0
MANF HM /SVC /FDR: 0 601 - 1WW amp.: 0 601 +amps- 1'A17 v: 0 MINOR LABEL -10: 0
1000+ amp /volt.: 0 — PLAN REVIEW SECTION —
Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS ARER /SPC OCC:
--- - - -- ELECTRICAL - RESTRICTED ENERGY — --
A. SF RESIDENTIAL - --- B. COMMERCIAL— — - - --
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: 0TH: .• BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL OTHR: ..
HVAC • DATA /TELE COMM.: NURSE CALLS • TOTAL 8 SYSTEMS: 0
Owner: - -- -- Contractor: TOTAL FEES:$ 13425.16
ANDREWS MANAGEMENT NCH CONSTRUCTION CO
4000 SW KRUSE WAY 8270 COLUMBIA EQUITIES INC
8235 SW OLESON RD STE C
LAKE OSWEGO OR 97035 PORTLAND OR 97223
Phone 8: 699 -8645 Phone 8: 224 -7410
Reg 8..: 049267
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other
applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180
days of issuance, or if work is suspended for more than 180 days.
----- -- -- REQUIRED INSPECTIONS -
Footing Insp Post /Beam Mechan Electrical Servi Low Voltage Insulation Insp Water Line Insp
Foundation Insp Plm /Underfloor Electrical Rough Framing Insp Shear Wall Insp Water Service In
Erosion Control Crawl Drain v. lanical Insp Fireplace Insp Firewall Insp Appr /Sdwlk Insp
Wtr Proofing Bsa Slab Insp Plumbi 2 Top Out .:s Line Insp Gyp Board Insp Sprinkler Underf
Post /Beam Struct Plm /undslb Ins', Low Vo 'age i's Fireplace Rai' Drain Insp Additional
c
Permit Signature: 1 •, ,, ��� Issued By: 10 IL_ I / ___
•
/
Call for inspection — 639 -4175
Commercial Building Permit Application
City o f Tigard
13125 SW Hall Blvd. , .. .. Tigard, OR 97223
\ E � L •
(503) 639 -4171 BUILDING C5
SW PFAFFLE & 83RD -- `.
WCI?VI 1 S 1 36CC _ LIJ 11- 2.7 _ o
1 Jobsite Address: Tax Lots 200, 300, 2000 -,ce jr :- 1
4732 Su.) PI - -(
'Office Use Only : :.::
Tenant: CAX1r (GI $ Alik Suite #
a: Z? :
r .
Valuation: - Planck/Rec # 7 "' . > ( .
5 "e; q4 9 t y5-, (9cv 6 /( c' ' Permit ��� Sri `l>� E Welk - 7
Owner: Andrews Management
Map &. TL # )5 — t-t1 . ( - 1 . ..:
Address: 4000 Kruse Way Place, Bldg 1, #270
Approvals Required::', ::
Lake Oswego, OR 97035
Planning
Phone: (503) 699 -8645
Engineering. . .
:. .: ..:. .
Other ;::..:..:. .
MCH Construction >';;:s;.
Contractor: :... ::.:.:...:: - :...:...
1-- A wr, t) : ?ivy OPrf .'72D
Address: 8235 SW Oleson Rd, Ste C .( - 6 14,,,)--1 S v `( ft r j : 1 t'
v - 64 !( #9 { A h _ z o
VN Portland, OR 97223 Type of const: 4 r ( ti `(
Occupancy class: R1
Phone: (503) 244 -0523
Sprinklered? Yes No)
Contractor's License # 49267
(attach copy of current Oregon license) Sq. ft. of project: 9,648
Contact name & phone: Phil McHugh (503) 244 -0523 Story (1st, 2nd, etc.) 2
Proposed use: Multi Family
Architect/Engineer: P. Rowell /R. G. Naff
Previous use: Vacant Land
Address: 18641 SW Benfield Avenue
Note: Plumbing & mechanical plans
Lake Oswego, OR 97035 must be :s ubmitt ed at time of
Phone:
(503) 639 -8045 building permit application.
JOB DESCRIPTION: 2 Story light frame wood construction
l M t ici ' ; t i L i - os'`;3
Applicant Signature & Ph94ie number
Received by: 9/a/Ki Date Received: 7/z Z
Permit # Account Description Amount Amt. Pd. Bal. Duey N'
i�y� -638 Bldg. Permit (BUILD) /7Z17.5 /72).5?) L-
• � Plumb. Permit (PLUMB) /o1). / U f ✓ ` .
Mech. Permit (MECH) /(O v . /6 O ✓
State Tax (TAX) 7'1 "1 • � i Z( 1 I . 2 ' I
F
Bldg: ��v� L�'� I,PR.MT , I3 za ELe & V 7-
, D
Plumb: sy, w '✓
Mech: 5 a /
Eal _ Ltle op
Plan Check
(PLANCK) / IZI•S /0I i95 - 105313 ,
Bldg: / / 2/. S8
Plumb: Z 70. w
RM 270 ✓
Mech: -90 - MEC fl-LI 14 to ✓
LIsc: za _ t LPLC 2-0
Su) (Ala -0W1 Sewer Connection (SWUSA) 210 490 -e,r Z(p�
Sewer Inspection (SWINSP)
Parks Dev Charge (PKSDC) t4 6 (UV, --
4' 15c1 ei - U IAA Residential TIF (TIF -R) 1 1 d r_ ( I SQk< ✓
4 12_ e a Uw•I} Mass Transit TIF (TIF -MT) ' qUicf li q.149LI t/
Commercial TIF (TIF -C)
Industrial TIF (TIF -I)
Institutional TIF (TIF -1S)
Office TIF (TIF -O)
Water Quality (WQUAL)
Water Quantity (WQUANT)
Fire Life Safety (FLS) 6m .2_, (o 5 w 3
Erosion Cntrl Permit (ERPRMT) i Rcl. /i c/ '
Erosion Planck/USA (ERPLAN) 5 -to S y ,ev
Erosion Planck/COT (EROSN) S944) S Y -iv
TOTALS: 7 61 1 q 2,c, I 64741/ 3 1, - M.
flK—
I
I
Community Development ELECTRICAL PERMIT APPLICATION
..4 13125 SW Hall Blvd.
Tigard, OR 97223 Planck/Rec. #
i� ll+ ti'I' l o Phone (503) 639 -4171 Permit # t4 �� - C3$6
( ) Date Issued
I - ' FAX (503) 684 -7297
CITY OF TIGARD TDD No. (503) 684 -2772 Issued by
Inspection (503) 639 -4175
. 1. Job Address: 4. Complete Fee Schedule Below:
1 %n. revelopment ( -22yki, 1 Number of Inspections per permit allowed
Address Si) h-+" i4' I e. Service included: Items Cost(ea) Sum
City /State/Zip -- 1 - 1 I-rZ -tom 4a. Residential - per unit � ? 4
Name (or name of business) C
1000 sq. n or less
. r Z $110.00 J��
� 00 Each sq. ft.r additional 500 sq. f1. or
portion thereof $25.00 1
Commercial ❑ Residential ❑ L imited Energy $25.00
Each Manul'd Home or Modular 2
Dwelling Service or Feeder $68.00
-
2a. Contractor installation only:
4b. Services or Feeders
Electrical Contractor ' • . Installation, alteration, or relocation 2 L. a • .. ' 200 amps or less $60.00
A • • -ss i 4 _ 201 amps to 400 amps $80.00 2
�� Zip ' r 401 amps to 600 amps $120.00 2
City OA/ .r. •. . ,. Sta O II2- p ' ,� 601 amps to 1000 amps $180.00 2 -
Phon' No. .MTAIIMi. Over 1000 amps or volts $340.00 2
Contractor's License No. 'EL Reconnect only $50.00 -
Contractor's Board Reg. No. a .'L4 4c. Temporary Services or Feeders
/ ��� Installation, alteration, or relocation 2
Signature of Supr. Elec'n 200 amps or less $50.00 2
-
- License No. 31.14, Phone N • . !fin Gam. 201 amps to 600 amps
$$00.00 2
Over 600 amps to 1000 volts
2b. For owner installations: see 'b' above.
Print 4d. Branch Circuits
rint Owner's Name
New, alteration or extension per panel
Address a) The fee for branch circuits with
City State Zip Each purchase
circuit or feeder fee. $5.00 2
i i Phone No. b) The fee for branch circuits without
The installation is being made on property I own which is purchase of service or feeder fee. 2
not intended for sale, lease or rent. First branch circuit $35.00 2
Each additional branch circuit $5.00
Owner's Signature 4e. Miscellaneous
(Service or feeder not included) • 2
Each pump or irrigation circle $40.00 2 - 3. Plan Review section (if required): Each sign or outline lighting $40.00 '
Signal circuit(s) or a limited energy 2
Please check appropriate item and enter fee in section 5B. panel, alteration or extension $40.00
• 4 or more residential units in one structure Minor Labels (t0) $100.00
Service and feeder 225 amps or more
System over 600 volts nominal 41. Each additional inspection over
Classified area or structure containing special occupancy the allowable in any of the above
as described in N.E.C. Chapter 5 Per inspection $35.00 - Per hour $55.00
-
In Plant $55.00
Submit 2 sets of plane with application where any of the above
apply. Not required for temporary construction services. 5. Fees:
NOTICE 5a. Enter total of above fees $ 3
5% Surcharge (.05 X total fees) $ :. `
PERMITS BECOME VOID IF WORK OR CONSTRUCTION Subtotal $ wf��...
AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF 5b. - ';'?" 1 re�1 -fer
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR Plan Review if required (Sec.3)O� $
A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS Subtotal ,
COMMENCED. ❑ Trust Account # $
Balance Due $ 0 J V
wadbwndrAelgpm.app
r
City of Tigard MECHANICAL PERMIT Planck/Rec. # ` 7 . 75
13125 SW Hall Blvd. APPLICATION 4 Permit # '�ST g
Tigard, OR 97223
(503) 639 -4171 \ I 1
I \ \v\
Na,,,. of De11. p,,,0,t Description
BU C5 - CARRIAGE HOUSE APIS. Table 3A Mechanical Code CITY PRICE AMT
Job SW Pfaffle & 83rd -i3 Z_ SuJ P-6- f(. 1) Permit Fee - 0- -0- 10.00
Address Calyrs,„e re
[C11 1S1 36OC Tax Hats 200, 300, 2000 2) Supplemental Permit 3.00
Nun. (er name e" Furnace to 100,000 BTU
Andrews Management, Ltd. (503) 699 -8645 1) incl. ducts & vents 6.00
M,g Add1eY Pion. Furnace 100,000 B I U +
Owner 4000_ Way Place Bldg 1 #270 2) incl. ducts & vents 7.50
GdydState LP Floor Fumance
Lake Oswego, OR 97035 3) incl. vent 6.00
None (Q name ° Suspended heater, wall heater
4) or floor mounted heater 6.00
Nano Address Phone Vent not incl. in
Occupant 5) appliance permit 20 3.00 60.00
Cdy'st1fe Z9 Repair of heating, refng.
6) cooling, absorption unit 6.00
None Boiler or comp, heat pump, air cond.
MCFI Construction ( 503) 244 - 0523 7) to 3 HP; absorp unit to 100K BTU 6.00
Mang Address Pte• Boiler or comp, heat pump, air cond.
COr 8235 SW Oleson Rd, Ste C 8) 3-15 HP; absorp unit to 500K BTU 11.00
°dy w Boiler or comp, heat pump, air cond.
Portland, CR 97 97223 9) 15-30 HP; absorp unit .5-1 mil BTU 15.00
State Re p aed.n No. �.•Tss N°• Boiler or comp, heat pump, air cond.
49267 10) 30-50 HP; absorp unit 1 -1.75 mil BTU 22.50 I e y acknowledge that I have read this application, that the Boiler or comp, heat pump, air cond. I
information given is correct, that I am the owner or authorized 11) > 50 HP; absorp unit 1.75 mil BTU 37.50
agent of the owner, that plans submitted are in compliance with Air handling unit to
State laws, that I am registered with the Construction Contractor's 12) 10,000 CFM 4.50
Board, that the number given is correct (If exempt from State Air handling unit
registration, please give reason below.) 13) 10,000 CTM + 7.50
Non portable
14) evaporate cooler 4.50
Vent fan connected
15) to a single duct r Z 3.00 f C -
Ventilation system not
16) included in appliance permit 4.50
game (ee"° « •0919 Data Hood served by
17) mechanical exhaust 4.50
Descnbe work new (Z) addition 0 alteration 0 repair 0 Commercial or industnal
to be done residential 6 non - residential 0 18) type incinerator 30.00
Existing use of Vacant land Other i.e., woodstove, water
building or property 19) heater, solar, clothes dryers, etc. 12 4.50 54.00
Proposed use of
Multi_ Fami
1 20) Gas piping one to four. outlets 2.00
building or property
Type of fuel - oil 0 natural gas 21) More than 4 -per outlet (each) 2.00
g 0 LPG 0 electric
NOTICE
Minimum Fee $25.00 SUBTOTAL //, (7 4.00
PERMITS BECOME VOID IF WORK OR CONSTRUCTION y - AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR 5% SURCHARGE 0
IF CONSTRUCTION OR WORK IS SUSPENDED OR
ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME PLAN REVIEW 25% OF SUBTOTAL q V ' 3 00
AFTER WORK IS COMMENCED.
TOTAL 2P,)'" 61. 0
Special Conditions
Date issued by
H:LLOOIMDSTSMEONPNT
4
To P,E. -6 U°
City of Tigard PLUMBING PERMIT APPLICATION Planck/Rec. # -
13125 SW Hall Blvd. Permit # 1A5T -C g5
Tigard, OR 97223 5w r- ./ Io d v
(503) 639 -4171 .
MINIMUM $25.00 PERMIT FEE + ST. SURCHARGE
".ms of Dsva1epm'a New Single Family Residences Only
BUILDING C5 - CARRIAGE HOUSE APTS
Ada.. ❑ 1 BATH HOUSE $140.00 ❑ 2 BATH HOUSE $195.00
Job SW PFAFFLE & 83RD - t32.. Su..) P-Ygtt (4.- ❑ 3 BATH HOUSE $225.00
Address cawwsmte ad Fee includes all plumbing fixtures in the dwelling and the first 100 feet
WCIM 1S1 36CC Tax Lots 200, 300, 2000 of water service, sanitary sewer and storm sewer. See fees below.
Name (or name of ®eeroeel FIXTURES QTY PRICE AMT
Andrews Management, Ltd. (503)699 -8645 Sink 12 9.00 108.00
Mang Address Felo1s Lavatory 20 9.00 180.00
Owner 4000 Kruse Way Place Bldg 1 #270 Tub or Tub/Shower Comb. 20 9.00 180.00
CltwSt"° n" Shower Only 9.00
Lake Oswego, CR 97035 Water Closet 20 9.00 180.00
Name der fume of business) Dishwasher 12 9.00 108.00
Garbage Disposal 12 9.00 108.00
Occupant Main ,,,m„• Washing Machine 12 9.00 108.00
Floor Drain 9.00
G"'s'ate m Water Heater 12 9.00 108.00
Laundry Room Tray 9.00
Name Urinal 9.00
MCH C�structi c n
Other Fixtures (Specify) 9.00
Mee on
Mining Address "he 9.00
Contra r 8235 SW Oleson Pd, Ste C (503) 244 -0523
9.00
9.00
Po rtland, C 97223 Sewer 1st 100' 30.00
C State Registration No. cis Bus. Tax Ns Sewer - ea. Addit. 100' 25.00
49267 Water Service 1st 100' 30.00
I hereby acknowledge that I have read this application, that the Water Service ea. Addis 200' 25.00
information given is correct, that I am the owner or authorized agent of
the owner, that plans submitted are in compliance with State laws, that Storm & Rain Drain 1st 100' 30.00
I am registered with the Construction Contractor's Board, that the Storm & Rain Drain Addit. 100' 25.00
number given is correct. (If exempt from State registration, please .
give reason below.) Mobile Home Space 25.00
Back Flow Prevention
Device or Anti - Pollution Device 9.00
Signalise (oener or agent) Date Any Trap or Waste Not
Connected to a Fixture 9.00
Describe work new CO addition 0 alteration 0 repair 0 Catch Basin 9.00
to be done residential (Xj non - residential 0 Insp. of Exist Plumbing 40.00/hr
Specially Requested Inspections 40.00/hr
Existing use of
building or property Vacant Land Rain Drain, single family dwelling 30.00
Residential backflow prevention
devices 15.00
Proposed use of Multi Family
building or property
'(Except residential backflow
prevention devices)
NOTICE *Minimum Fee $25.00 SUBTOTAL 1,080.0)
PERMITS BECOME VOID IF WORK OR CONSTRUCTION
AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF 5% SURCHARGE 54.00
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED
FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS
COMMENCED. PLAN REVIEW 25% OF SUBTOTAL 270.00
TOTAL 1,404.00
Special Conditions
Date issued by
./14 5 i — v - o 3 8' S
September 25, 1996 CITY OF TIGARD
OREGON
Carlson Testing
P.O. Box 23814
Tigard, OR 97281
PERMIT NO: SIT96 -0042
OWNER: Andrews Management
PROJECT ADDRESS: SW Pfaffle & 83rd g 3 3a,, 0
PROJECT DESCRIPTION: Carriage House (Site)
TYPES OF SPECIAL INSPECTION: Soils special inspections.
Dear Mr. Leach:
The owner has notified us that he/she will retain your services to perform Special Inspections in accordance
with the provisions of the State Building Code, permit documents, and special inspection requirements.
The owner or the owner's agent must also confirm with you that they have authorized you to do the special
inspection work.
As the regulatory agency, the City requires that you do the following:
1 1. Submit copies of all inspection reports promptly to the Building Division, architect, engineer,
and the contractor.
2. Maintain one copy of each field report at the job site.
3. Submit a final report at the completion of each category of work that you inspect. (See
U.B.C. 3318 for soils special inspection final report requirements).
If you fail to comply with the above requirements, there may be cause for the City to revoke your authority as
special inspector for this job. -
Should you have any questions, please call the Building Division at (503) 639 -4171.
Sincerely,
i
;'Jim Funk
Building Division
Enclosure
Uoasumnplam't notfy.dot
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
/vi Sri& - v-o 3 S 5
Page No. 1 CASE HISTORY FOR CASE NO.: SDR96 -0007
ANDREWS MANAGEMENT LTD
08320 SW PFAFFLE ST Unit: PREY
04/25/98
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
SDRA007 Application received / / / / 03/15/96 WD 04/24/96 WRD
SDRA020 Application acceptance date / / / / 04/29/96 WD 04/26/96 WRD
SDRA350 Conditions completed / / / / 10/20/97 PASS JDA 10/20/97 JDA
SDRC310 Request approved subj. to cond 06/20/96 / / 07/01/96 WD 11/27/96 WRD
•
Page No. 1 CASE HISTORY FOR CASE NO.: MST96 -0385
ANDREWS MANAGEMENT
08332 SW PFAFFLE ST
01/30/98
Action Description Real/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
-- -- --- -- ------ - --
MSTA790 Electrical Final / / / / 09/05/97 Corrections ok, final appears ok. PASS BRP 09/11/97 J•H
MSTB005 Application received / / / / 07/22/96 RECD JH 07/30/96 BON
MSTB008 Permit created / / / / 07/30/96 PEND B 07/30/96 BON
MSTB012 Plans routed to Plans Examiner / / / / 07/30/96 PEND B 07/30/96 BON
MSTB015 Requested revised plans fr app / / / / 10/28/96 this is a letter to office service JF 10/28/96 BT2
category
MSTB026 Plans approved by Plans Exmr / / / / 11/21/96 JHF 11/21/96 JHF
MSTB026 Plans approved by Plans Exmr / / / / 11/25/96 house panel an seperate permit PASS MJR 11/26/96 MJR
MSTB030 Reviewed plans routed to DSTS / / / / 08/19/96 PASS MS 08/19/96 MRS
MSTB030 Reviewed plans routed to DSTS 11/21/96 / / 11/21/96 APPR JHF 11/21/96 JHF
MSTB090 (F) Ready to issue / / / / 11/26/96 Still need plumbing business license MEMO B 11/27/96 BON
info before issuing permit. Be sure to
enter TIF fees after issuing permit.
MSTB098 (F) Issue combination permit / / / / 11/27/96 PASS B 11/27/96 BON
MSTB103 Issue plumbing signature form / / / / 11/27/96 PASS B 11/27/96 BON
MSTB104 Issue Electric Signature Form / / / / 12/18/96 OR B 12/18/96 RB
MSTB705 Footing Insp / / / / 12/02/96 APP GS 12/03/96 GES
MSTB706 Foundation Insp / / / / 12/17/96 PASS RB 12/17/96 RB
MSTB710 Post /Beam Structural / / / / 02/12/97 pending- back -water value at low points; FAIL RB 02/12/97 RB
sill plate- 2 anchor bolts req'd ea.
piece; firestop thru penetrations at
firewall.
plumbing under -floor req'd.
MSTB710 Post /Beam Structural / / / / 02/14/97 PASS RB 02/19/97 RB
MSTB710 Post /Beam Structural / / / / 02/19/97 pending- post missed; anchor bolts PASS RB 02/19/97 RB
missed; remove debris; back water valve
at low points.
MSTB712 Plm /Underfloor / / / / 02/19/97 PASS MS 02/19/97 MRS
MSTB717 Underfloor insulation / / / / 02/21/97 PASS RB 02/21/97 RB
MSTB723 Electrical Service 11/26/96 / / 05/29/97 ELECTRICAL SERVICE AND ROUGHIN APPROVED. PASS MJR 05/30/97 J•H
MSTB724 Electrical Rough -in 11/26/96 / / 05/29/97 ELECTRICAL SERVICE & ROUGH -IN APPROVED. PASS MJR 05/30/97 J•H
(Paddle fan upstairs in dining room (2
bdrm).
MSTB725 Mechanical Insp / / / / 09/19/97 PASS RB 09/21/97 J•H
MSTB727 Plumbing Top Out / / / / 05/20/97 PASS MS 05/21/97 MRS
MSTB727 Low Voltage 11/26/96 / / / / 11/26/96 DST
MSTB730 Framing Insp / / / / 05/29/97 SEE REPORT THIS DATE: 21 WORKMANSHIP FAIL RB 05/31/97 J•H
AND /OR CODE VIOLATIONS
1
Page No. 2 CASE HISTORY FOR CASE NO.: MST96 -0385
ANDREWS MANAGEMENT
08332 SW PFAFFLE ST
01/30/98
Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTB745 Insulation Inep / / / / 06/04/97 1. Provide vapor barrier at door FAIL RB 06/06/97 J *H
headers.
2. Insulate that part of the ceiling
assembly where sprinkler system is
covered with visqueen AND will not get
proper insulation coverage below or
above insulation level. ESPECIALLY NOTED
AT EXTERIOR VENT LOCATIONS.
3. That part of the 2 -hr. wall from fire
block to ceiling level of the higher
floor is not properlyu insulated to full
depth of wall cavity.
4. AT location at end units, the rear
shower enclosure lid is not tightly
patched.
5. Remove vapor barrier of end unit
shower enclosure (above shower in
exterior wall.
6. Unit 125, repair exhaust vent in
laundry room.
TYPICAL INSPECTION ALL UNITS.
MSTB750 Shear Wall Inep / / / / 05/29/97 SEE REPORT THIS DATE: 21 items. FAIL RB 05/31/97 J *H
MSTB755 Firewall Insp / / / / 05/29/97 SEE REPORT THIS DATE: 21 ITEMS. FAIL RB 05/31/97 J *H
MSTB755 Firewall Inep / / / / 05/12/97 1 -hr behind tub /shower PASS RB 05/12/97 RB
MSTB760 Gyp Board Insp / / / / 05/29/97 SEE REPORT THIS DATE: 21 ITEMS FAIL RB 05/31/97 J *H
(workmanship and code violations)
MSTB779 Rain Drain Inep / / / / 12/20/96 perimeter ok PASS MS 12/23/96 MRS
MSTB780 Water Line Insp / / / / 01/30/98 PER CONVERSATION WITH MIKE SHEEHAN PASS MS 01/30/98 JT
MSTB789 Smoke Detector 09/17/97 / / 09/17/97 PASS RB 12/12/97 RB
MSTB796 Electrical Final 11/26/96 / / 08/21/97 Devices are not touching wall surface, FAIL BRP 08/21/97 B *P
numerous locations.Pull all wall plates
and install spacers to assure that a
secure mounting is obtained between
device and outlet box.NEC Article
370 -20, 370 -21, 410- 56(e).
Many places the eheetrock is more than
the allowed clearance from the outlet
box.
MSTB798 Mechanical Final / / / / 09/19/97 PASS RB 12/26/97 RB
Page No. 3 CASE HISTORY FOR CASE NO.: MST96 -0385
ANDREWS MANAGEMENT
08332 SW PFAFFLE ST
01/30/98
Action Description Req/ Scbd/ End/ Action Notes Diep By Update Upd
Code Sent Done Done Date By
MSTB799 Building Final 11/26/96 / / 09/15/97 Unable to perform "pre - final" as City FAIL RB 09/16/97 J *H
policy prohibits walk -thru as per George
Steele, Lead Bldg Inspector and Hap
Watkins, Supervisor.
Check records for above check marked
inspections, case history approvals
omitted.
MSTB799 Building Final / / / / 09/19/97 PASS RB 12/26/97 RB
MSTB800 Final inspection / / / / 09/19/97 PASS RB 12/26/97 RB
MSTD400 Devel review cond. met / / / / 10/20/97 PASS JDA 10/20/97 JDA
MSTD706 Foundation Inep 09/21/97 / / / / 09/21/97 J *H
MSTD713 Crawl Drain 09/21/97 / / / / 09/21/97 J *H
MSTD730 Framing Insp 06/07/97 / / 06/02/97 2. Vent baffles req'd FAIL RB 06/07/97 J *H
3. Insulate (firestop) behind showers
and end units (top E. bottom).
MSTD745 Insulation Insp / / / / 06/05/97 ISSUES UNRESOLVED. CALL FOR FAIL RB 06/06/97 J *H
REINSPECTION.
MSTD750 Shear Wall Inap 06/07/97 / / 06/02/97 1. NAIL SHEAR SHEATHING AS MARKED. FAIL RB 06/07/97 J *H
SEE FRAMING NOTES THIS DATE.
MSTD750 Shear Wall Inep / / / / 06/19/97 Approved pending corrections: PASS RB 09/16/97 J *H
1. Nail bottom edge of panel within
alcove at rear, above highest window
unit at right of block /flush notation.
2. Nail edge of last unit in front,
gypsum at storage and OSB if of window
unit.
MSTD760 Gyp Board Insp / / / / 06/06/97 1. Main floor (lower level, add 2 -hr FAIL RB 06/07/97 J *H
wall in closet.
MSTD760 Gyp Board Inep / / / / 06/16/97 1. Nail through -out w /12" screws at wall PASS RB 06/16/97 J *H
locations where greater than allowable.
Note: areas near base plante.
2. Screw nail at green board., ie, 129,
etc.
3. Ceiling gyp board when nailed 7" o.c.
required, and walls 8" o.c. at joints,
ie, 130, etc. Lots of missed locations,
unable to inspect upper floor at both
sides of east end.
MSTD781 Water Service Inep 09/21/97 / / 01/30/98 per conversation with Mike Sheehan PASS MS 01/30/98 JT
�1
Page No. 4 CASE HISTORY FOR CASE NO.: MST96 -0385
ANDREWS MANAGEMENT
08332 SW PFAFFLE ST
01/30/98
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTD796 Electrical Final / / / / 08/27/97 1. Previous corrections have not been FAIL HRP 09/04/97 J *H
done.
2. Many devices are floating; not firmly
attached to wall surface.
3. Outlet boxes more that 1/4 offset
form finish surface.
MSTD798 Mechanical Final / / / / 09/19/97 PASS RH 09/21/97 J•H
1\
Page No. 5 CASE HISTORY FOR CASE NO.: MST96 -0385
ANDREWS MANAGEMENT
08332 SW PFAFFLE ST
01/30/98
Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd
(bde Sent Done Done Date By
MSTD799 Building Final / / / / 09/17/97 1. Cap or utilize rain drain where left FAIL RB 09/18/97 ■+H
open at exterior. Cover rain drain at
middle between C5 & A6.
2. Insulation fallen cut of underfloor
cavities. All units need to be checked.
3. UNIT 228: Seal gyp above storage
sprinkler head.
4. UNIT 128: Family bath fan making
noise.
5. UNIT 127: Cover exhaust fan at
laundry room. Cover exhaust fan at
master bath. Insulate sprinkler lines
where needed within storage AND firestop
thru hole penetrations.
6. UNIT 227: Pending building
corrections. Secure base of stairs.
7. UNIT 126: Seal gyp storage sprinkler
head.
8. UNIT 125: Seal low voltage wire
through hole penetration above hot -water
heater.
9. UNIT 225 & 226: Flush mount sprinkler
head bedrooms. Secure base of stairs.
Secure guardrail at top of stairs.
10. UNIT 225: Seal low voltage wire
through hole peneteration above
hot -water heater. Flush mount sprinkler
head at laundry room.
11. UNIT 130: Seal through hole
penetrations at hot -water heater. Cover
for exhaust fan in bathroom.
12. UNIT 129: Laundry exhaust fan
doesn't work.
13. UNIT 230: Anchor /secure guardrail
top of stairs.
14. UNIT 229: Same as 230. Seal around
sprinkler head at master bedroom.
POST PERMANENT ADDRESSES.
R -38 ATTIC INSULATION REQUIRED.
SEE BUP96 -612, 621 FOR ALARM /SUPPRESSION
, r l
Page No. 6 CASE HISTORY FOR CASE NO.: MST96 -0385
ANDREWS MANAGEMENT
08332 SW PFAFFLE ST '
01/30/98
Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd
Cdde Sent Done Done Date By
MSTD799 Building Final 09/21/97 / / 09/19/97 PASS RB 01/30/98 JT
By review, Leatha Thomas approved site
as per her responsibility.
1/30/98 to Jill for C/O approval
al + y�aa
/
/\ Date
itt
0 CITY OF TIGARD BUILDING INSPECTION DIVISION
24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171
Date Requested: I -/ 1 '7 A.M. it *- MST: 96 S
Location: a S 3 _ _ , ' / 101 BUP:
/ ,
Tenant: J Suite: Bldg: G5 MEC:
Contractor: MCJ4 /p
Phone: ( ) -(- -- 0 (T 36 PLM:
Owner: Phone: ELC:
ELR:
_ SIT:
BUILDING BLDG n't) PLUMBING
441011 CAL ELECTRICAL SITE
Site ' • earn Post/Beam :. r :earn Cover /Service Sewer /Storm
Footing Roof UndFl/Slab Rough -In Ceiling Water Line
Slab Framing Top Out Gas Line Rough -In UG Sprinkler
Foundation Insulation Sewer Hood/Duct Reconnect Vault
Bsmt Damp Drywall Storm Furnace Temp Service MISC.
Masonry Ceiling Rain Drain A/C UG Slab
Shear /Sheath E' /Alm Crawl/Found Dr H : ti _ p Low Volt
Approv Approved Approv:.I Approved Approved
Appr /Sdwlk roved Not Approved ' . s . ed Not Approved Not Approved
AP FINAL FINAL FINAL FINAL
'' •
---)
•
0/ ( . 1 , , -- .716
\ - - - . - - . . . . . )
O Call for reinspection O Reinspection fee of $ required before next inspection O Unable to inspect yz , ,
Inspector: .�' Date: I t9 (1 7 Page of