Loading...
Correspondence City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 r r pnpy • . . ttj June 9, 2008 T I GARD Annette Saarinen 9755 SW Pembrook Street Tigard, OR 97224 RE: ADDITION TO SINGLE FAMILY RESIDENCE - PLAN REVIEW #2 Project Information Building Permit: MST2008 -00058 Construction Type: VB Address: 9755 SW Pembrook St. Occupancy Type: R -3 Area: 90 sq. ft. Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2007 edition; the State of Oregon Residential Specialty Code (ORSC) 2005 edition and the Oregon Fire Code 2007 edition. The submitted plans have been reviewed and the following information is required prior to issuance of the permit. NOTE; The Oregon Residential Specialty Code referenced above is available in a read only format @ www2.iccsafe.org/ states /oregon /Residential /Res_Frameset.htm 1. The plans do not indicate any lateral wall bracing. The wall heights indicated on the plans exceed 12' and therefore are not within the parameters of prescriptive construction (Table R602.10.3(1) footnote j or Table R602.10.3(2) footnote i). Please revise the plans to meet all requirements of section 602.10 or provide an engineered design prepared by a professional engineer licensed to practice in the State of Oregon. Response not accepted: The typical portal frame detail shown on sheet 1 does not allow panel heights of 10' as shown on front elevation on sheet 1 and requires equal panels on both sides of opening. Simpson Strong -Wall panels require structural engineering to determine actual load to be resisted by panel and the literature provided does not include the panel specified on sheet 1 and 2. 2. Please clarify and provide construction details for how the stairway has been added, or • extended, into the new addition. R106.1.1 Response accepted: Applicant has provided necessary information through phone conversation and plan revisions to clarify changes to existing stairway. Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard or.gov • TTY Relay: 503.684.2772 s' 3. The typical section provided does not meet code minimum for reinforcement or insulation and the roof framing does not match the call out for roof trusses on other documents provided. Please provide plans meeting the minimum reinforcement requirements of section R403.1.4. Indicate the energy code path to be followed from Table N1104.1(1) and update the cross section to match choscn path. Also please revise notes and /or section and provide a roof framing plan indicating the actual roof framing construction proposed. Response accepted: Note that the alternate brace panel foundation section on sheet 2 would require #4 vertical bars at 48" on center if poured with a construction joint. 4. Please provide a foundation plan indicating the required ventilation (R408.1), drainage (R408.5), and access (R408.3). Response partially accepted: Access shown on sheet 2 is acceptable, but no low point drain or method of removal of water from new crawl space is shown on the plans. 5. Please clarify and provide construction details on how the existing roof will tie into the roof on the proposed addition. R106.1.1 Response accepted 6. Please provide an item by item response to each of the above items clearly indicating how each plan review comment has been addressed. Response not accepted: There was no item by item response to the above plan review comments submitted with the revised plans. 7. New item: The ledger board for the new floor at the entryway is shown to be attached to concrete with ' "x4" Lag Bolts. Please clarify the attachment with a product listed and designed for concrete attachment. RI06.1.1 8. New item: The plans do not indicate tempered or safety glazing in the sidelight as required for hazardous locations in section R308.4. NOTE: For further clarification of information required for a complete plan submittal, see the building permit application checklist (for all residential projects) located @ www.tigard-or.gov/ city_hall /departments /cd /docs /BUP- RESPermitApp.doc. • rJ • • When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Mark VanDomelen Plans Examination Supervisor City of Tigard marker a,tigard- or.gov (503)718 -2759 .; ° City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 UI May 19, 2008 BILE C0 PY Annette Saannen TIGARD 9755 SW Pembrook Street Tigard, OR 97224 RE: ADDITION TO SINGLE FAMILY RESIDENCE Project Information Building Permit: MST2008 -00058 Construction Type: VB Address: 9755 SW Pembrook St. Occupancy Type: R -3 Area: 90 sq. ft. Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2007 edition; the State of Oregon Residential Specialty Code (ORSC) 2005 edition and the Oregon Fire Code 2007 edition. The submitted plans have been reviewed and the following information is required prior to issuance of the permit. NOTE: The Oregon Residential Specialty Code referenced above is available in a read only format @ www2.iccsafe.org /states /oregon /Residential /Res_Frameset.htm 1. The plans do not indicate any lateral wall bracing. The wall heights indicated on the plans exceed 12' and therefore are not within the parameters of prescriptive construction (Table R602.10.3(1) footnote j or Table R602.10.3(2) footnote i). Please revise the plans to meet all requirements of section 602.10 or provide an engineered design prepared by a professional engineer licensed to practice in the State of Oregon. 2. Please clarify and provide construction details for how the stairway has been added, or extended, into the new addition. R106.1.1 3. The typical section provided does not meet code minimum for reinforcement or insulation and the roof framing does not match the call out for roof trusses on other documents provided. Please provide plans meeting the minimum reinforcement requirements of section R403.1.4. Indicate the energy code path to be followed from Table N1104.1(1) and update the cross section to match chosen path. Also please revise notes and /or section and provide a roof framing plan indicating the actual roof framing construction proposed. 4. Please provide a foundation plan indicating the required ventilation (R408.1), drainage (R408.5), and access (8408.3). Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 1 5. Please clarify and provide construction details on how the existing roof will tie into the roof on the proposed addition. R106.1.1 6. Please provide an item by item response to each of the above items clearly indicating how each plan review comment has been addressed. • NOTE: For further clarification of information required for a complete plan submittal, see the building permit application checklist (for all residential projects) located @ www.tigard-or.gov/ city_hall /departments /cd /docs /BUP- RESPermitApp.doc. When submitting revi drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Mark VanDomelen, - Plans Examination Supervisor City of Tigard • niarkvntigard- or.gov - (503)718-2759 - • • • •