City of Tigard
Building Department
13125 SW Hall Blvd.
Tigard, OR 97223
- Re: 8060 SW Pfaff le, Tigard, OR 97223
Permit No. BUP 2001 -00.45
Gentlemen: •
In accordance with Section 1702 of the 1998 OSSC, this letter will serve as the final
Engineer of Record Observation summary letter for the referenced project.
VLMK Consulting Engineers has completed structural observations in accordance with
thespecial inspection program as prepared by VLMK Consulting Engineers and
submitted to the City of Tigard. VLMK Consulting Engineers has also reviewed the
Special •lrispection Testing Reports as prepared by Carlson Testing.
To the best of our knowledge, all work has been completed in accordance with permit
approved drawings, specifications, and Engineer of Record directives.
If you should have any questions, please do not hesitate to call.
rely,
4
James E. Knauf, P.E. /S.E., Principal �`���� N Op i .
VLMK Consulting Engineers �, . y
':/ . • •82PE .
Cc: Michael Jones, LRS ,,/ - • -1/ •
Eric Meeuwsen, Panattoni Const. /
U :- "- 'Ceilson Tetirig.;..,`. .:. - 14 9 ,�0 0►. Q
fi ' l:: °.M1 1 {: . t `
.l i _ .. . .t,t . ..
1 • • , .. P J , � . , 4
' - .
` , !_::�; (: ') - . -•' .i? !, i,,; ••. :: ; :.�'. . �,
• , rte
.( C. :i.2ni1!L'_ E'. :-iii :
I Structural Engineering • Civil Engineering • Industrial Engineering • Planning • Studies / Evaluations • Entitlement
June 20, 2002 4 8 6 4,iph +\
CITY OF TIGARD
Cameron Park Plaza OREGON
8060 SW Pfaffle St.
Tigard, OR 97223
Cameron Property Development LLC
5665 SW Meadows Rd. .
Suite 300
Lake Oswego, OR. 97035
Re: BUP2001- 00345, New 20,400 -sq. ft. office building (Shell Only) at 8060 SW Pfaffle
To whom it may concern:
This letter is to certify that all requirements of building permit #BUP2000- 00345, issued
for a building shell, have been completed. The final inspection was performed and
approved on 06- 10 -02, by inspectors from the City of Tigard. No tenant spaces are
included in this permit, nor shall any tenant improvement be occupied until such time as
each space is approved by final inspection of its specific permits, approved for the use
intended and provided with a Certificate of Occupancy.
The City neither guarantees nor warrants to the owner, occupant or any other person
that this letter evidences strict and complete compliance with each and every ordinance
or regulation of the City or the State of Oregon affecting the construction or use of said
structure or the land upon which is situated. Such compliance is the responsibility of
the owner and /or occupant of the premises. V
This letter certifies only that the work covered under the permit number listed above has
been completed. It is . not permission to occupy tenant spaces.
Sincerely,
1 .7 0 4.\
Gary Lampella
Building Official
is Bldg /complltr
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
09/27/01 THU 15:45 FAX 503 591 0986 TVWD ENGINEERING Iii] 001
•
TualatinlValley
District 1650 SW 170th Ave. • P.O. Box 745 • Beaverton, Oregon 97075.503/642 -1511 • FAX: 503/649.2733
Gregory , E DlLoreto
General Manager
Bernice Bagnall
Chief Financial QBicer
September 27, 2001 •
Dale Fishback
Manager, /vices ins
& • Gary Lampella, Building Department
Reid services
'4
City of Tigard
13125 SW Hall Blvd
• Brenda Lennox Tigard Or 97223
Manager. Customer g
. .s. Support Services
RE: Cameron Plaza, 8060 SW Pfaffle Street, Tigard, Or 9722 .
Gary Pippin
Manager, Engineering
Services •
The Tualatin Valley Water District has reviewed and approved the water service -
to this development. Domestic service will be a 1 ' /2" meter and the fire. service
will be a 6" service. 1
The developer's contractor has been given the District's standards for these
improvements. All work will be done per the'Tualatin Valley Water District's
standards.
--1-3c-1-)-4-1 . . ' ,_ .
Gary Pippin P.E. - .
. Manager Engineering Services
Post -Ir Fax Note 7671 D17 / l 8a°' / .
To �p�g��� t F r. d- i •
Phone # - - - Phone 903 . :r/2 `5 //
• Fax # .0 0 .3 6,,_-7297 Fax #S,3 - S9/ c',96`.
•
Post -It Fax Note 7671 Date I re .. • • ' •
• •
To r.. 7 ,4 J From �/,�1 .
Co./Dept . ' . Co: �v / vv. L)
Phone # / i, v 2 5 o l - Phoneme #. /5. t/ •
. Fax # L3 . z7i _ : Fa x 85 f03 - 2I 0986
0 . • . . .
C of Tigard Bldg Dept.docJl:My Documents -Gary Pippin/'rSperry /0927/01 '
WATER - not to be taken for granted _ •
— comp \ — i � v 2,0 -co3115
El
CITY OF TIGARD
OREGON
November 15, 2001
Encompass Mechanical
5711 SW Hood
Portland, OR 97201
Re: " Cameron Plaza — Permit # MEC2001 -00343
8060 SW Pfaffle
Tigard, OR
The City of Tigard has completed the review of the submitted plans for the mechanical
installation at the above referenced address. This review was performed under the provisions of
the State of Oregon Mechanical Specialty Code (OMSC), 1999 edition. The plans are approved
subject to the following conditions.
1. Smoke detection shall be provided in the return-air duct of this system. OMSC Section 606.
2. The plans appear to show the ceiling as a return-air plenum. All materials installed in this
return-air plenum shall meet the requirements of OMSC Section 602 or be plenum rated by
testing.
3. The gas piping shall be tested to ensure that it is gas tight in accordance with OMSC Section
1304.18.
4. A copy of the approved plans shall be on the job site and available to the inspector for
inspection purposes at all times.
Sincerely,
1„....
Gary Lampella
Building Official
c. File
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
RECEIVED
Panattoni APR 03 2002
J I CO NSTRUCTION
CITY OF TIGARD
PLANNING/ENGINEERING
April 3, 2002
Mr. Gary Lampella
City of Tigard
13125 SW Hall Blvd
Tigard, OR 97223
Re: Cameron Plaza Office Building
BUP2001 -00345
Dear Gary,
Attached is a copy of a February 13, 2002 letter regarding the Cameron Plaza Office Building
and related tenant improvement. Darrel Jones has asked for the value of the second floor tenant
improvement that was not completed, so the City could refund a portion of the permit and be
able to provide a Certificate of Occupancy for the Building/Core work only.
The value of the 2 floor tenant improvement work was $270,170. Please let me know if you
need any more information.
If you have any questions, please give me a call at 503- 345 -0647.
Sincerely,
Panattoni Construction Inc.
nc Meeuwsen
Project Manager
cc: Kirk Cameron
Panattoni Construction, Inc.
1400 SW Fifth Avenue, Suite 810, Portland, OR 97201 TEL 503/274 -4442 FAX 503/274 -5485 OR Lic #140755
Panattoni JI CON STRUCTION
February 13, 2002
Mr. Gary Lampella
City of Tigard
13125 SW Hall Blvd
Tigard, OR 97223
Re: Cameron Plaza Office Building
BUP2001 -00345
Dear Gary,
I met with Darrel Jones regarding the above permit and discussed the revision to the 2 floor
tenant improvements. The tenant that was originally taking the entire second floor has now
decided to take one half of the first floor. The permit for the project includes both the Shell/Core
and Tenant Improvement for the second floor.
We are requesting that the City of Tigard take out the 2n floor tenant improvement from the
permit, as we will only be completing the Shell/Core work and would want a certificate of
occupancy for this work only.
The Owner requests a credit for this 2 floor tenant improvement permit and understand they
will not be reimbursed for the plan review fees and approximately 80% of the remaining fees.
In addition we have submitted to the City of Tigard the plans for the first floor Tenant
Improvement and request this work be permitted as a separate space.
If you have any questions, please give me a call at 503- 345 -0647.
Sincerely,
Panattoni Construction Inc.
nuwsen
Project Manager
cc: Kirk Cameron
Panattoni Construction, Inc.
1400 SW Fifth Avenue, Suite 810, Portland, OR 97201 TEL 503/274 -4442 FAX 503/274-5485 OR Lic# 140755
CITY OF TIGARD
•
F ILE COPY R
November 8, 2001 O EGON
Michael Jones
LRS Architects, Inc.
1121 SW Salmon, Suite 100
Portland, OR 97205
RE: CAMERON PLAZA
PROJECT INFORMATION
Address: 8060 SW Pfaffle Street Number of Stories: 2
Permit Number: BUP2001 -00345 Sprinklered: Yes
Occupancy Group: B Fire Alarm: Yes
Type of Construction: VN Rated Corridors: No
Floor Area: 20,400 Sq. Ft. Rated Stairways: Stairway 110 — 1 -Hour
Other Ratings: South & Part of West Wall
See Sheet A0.2
The City of Tigard Building Division has reviewed the submitted building plans for the above
referenced address in accordance with the Oregon Structural Specialty Code (OSSC), 1998
edition and the Uniform Fire Code, 1997 edition as amended by Tualatin Valley Fire & Rescue.
The plans are approved subject to the following conditions.
1. Plumbing, electrical, mechanical, fire alarm and fire sprinklers will be by separate permit.
Plumbing, fire alarm and fire sprinkler permits will be deferred submittals. Deferred
submittals shall be reviewed by the engineer or architect of record prior to submittal to the
City of Tigard to ensure that the plans are in general conformance with the design of the
building. OSSC 106.3.4.2.
2. Deferred submittals identified on Sheet S0.0 shall be reviewed by the engineer of record
prior to submittal to the City of Tigard for review. OSSC 104.3.4.2.
3. Special inspection as identified on Sheet S0.0 will be by Carlson Testing and structural
observation will be performed by the engineer of record. Reports shall be sent to Hap
Watkins, Inspection Supervisor at 13125 SW Hall Blvd., Tigard, OR 97223. Any
discrepancies shall be brought to the immediate attention of LRS Architecture. Final signed
reports shall be submitted to the City of Tigard Building Division in accordance with OSSC
1701.3
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
•
•
• 4. Special inspection required by OSSC Chapter 17 is in addition to the inspection required by
OSSC 108. Special inspectors shall leave field copies at the site for review by the. City of
Tigard inspectors. Any discrepancies shall be brought to the immediate attention of the
contractor for correction, then, if uncorrected, to the proper design authority and to the
building official. OSSC 1701.3.
•
5. Fire - resistive assemblies shall be maintained and all penetrations through such assemblies
shall be protected'with penetration firestops in accordance with OSSC 709.6 through 709.7
and 714.
6. The fire -rated doors into Stairway 110 shall have closing actuation in accordance,with OSSC
713.6.1.
•
7. Exits signs shall be internally or externally illuminated at all times and shall have an •
emergency power source. OSSC 1003.2.8.4 and 1003.2.8.5.
8. The means of egress shall be illuminated at an intensity of not less that 1 foot -candle at the
floor level. This lighting shall have backup power from an automatic emergency system in
the event of a power failure. OSSC 1003.2.9.2.
9. Exit doors shall be openable from the inside, without the•use of a key or any special
knowledge or effort. OSSC 1003.3.1.8.
10. Stairways and handrails shall comply with the provisions of OSSC 1003.3.3.1 through
1003.3.3.7. -
11. Accessible parking shall be installed and signed in accordance with OSSC 1104.1 and ORS
447.233.
12. Handles, pulls, latches, locks and other operating devices on doors, cabinets, plumbing
fixtures and storage facilities shall have level or other shape permitting operation by wrist or
arm pressure and not require tight grasping; pinching or twisting to operate. OSSC 1109.3.1.
13. Mounting heights for environmental and other controls, dispensers, electrical and
communication equipment system receptacles on walls and other operable equipment shall
be within at least one of the reach ranges specified in Section 1109.2, and not less than 36
. inches above the floor. OSSC 1109.3.2.
14. Floor coverings and surfaces shall comply with OSSC 1109.6 for accessibility. .
15. Stairways shall comply with OSSC 1 -109.8 for accessibility. •
y .
16. Doors shall comply with the requirements of 1109.9 for width, maneuvering clearances,
thresholds, closers, hardware and opening force. The opening force for exterior doors shall
not exceed 8 V2 pounds and interior door 5 pounds.
17. Minimum 2A,10BC fire extinguishers shall be provided throughout the building so the travel
distance between extinguishers does not exceed 75 feet. UFC Standard 10 -1.
18. A copy of the approved plans shall be on the job site at all times and available to the City of
Tigard inspectors for inspection purposes. OSSC Section 106.4.2.
19. A final inspection and Certificate of Occupancy is required prior to occupying for the
intended use of this building or parts thereof. OSSC Section 109.1.
If you have any questions regarding this review, please contact me at (503) 369 -4171 ext. .
Sincerely,
1
Gary Lampella
Building Official
c. Kirk Cameron, eei Solutions — Fax (503) 297 -9166