Loading...
Specifications Fire Systeiis West, Inc. 600 SE Maritime Avenue, Suite 300 • Vancouver, Washington 98661 • Phone (360) 693 -9906 • Fax (503) 289 -2208 B M P looI-oo? . EQUIPMENT SUBMITTAL • CAMERON PLAZA OFFICE BUILDING 8060S.W. PFAFFLE TIGARD, OR Fire Systems West Project Number: 1 -10 -1593 FIRE SYSTEMS WEST, INC. 600 SE Maritime Avenue, suite 300 Vancouver, WA 98661 (360) 693 -9906 office (503) 289 -2208 fax OR CL #49732 WA CL #FIRESWI 140B1,1 ,OR ECL-' #37 ECL #FIRESWI 055LW, j MATERIAL SUBMITTAL Job Name: CAMERON PLAZA Job Number: 1 -10 -1593 No. Item Manufacturer/Model Size Remarks 1 SPRINKLERS Upright, Pendent EC GEM F895 ECOH 3 /4 "/11.2K 155° F, Brass Pendent Sprinkler EC, QR Gem F890 ECLH QR 3 / "/8.0 K 155° F, Chrome, Chrome Recessed Pendent, Gem Model A QR 1 /2 "/5.6 K 155° F, Chrome, Chrome Sprinkler QR Upright Sprinkler QR Gem Model A QR 1 /2"/5.6K 155° F, Brass Horizontal Sidewall Gem Model A EC QR 3 /4 "/8.1K 155° F, Chrome, Chrome Sprinkler EC, QR 2 PIPE AND FITTINGS Allied Super 40/Dyna- Thread Grinnell 1 " -2" Threaded Allied Super- Flow/Dyna -Flow Grinnell 1 1 /4 " -2 Grooved Class 125 Cast Iron Fittings Grinnell 1 /2 " -2" Threaded Class 125 Malleable Fittings Grinnell 1 /2" -2" Threaded Grooved Fitting Gruvlok 1 1 /4 " -2 Grooved Grooved Coupling Gruvlok 1 1 /4 " -2 Grooved Sock -it Gruvlok 1 " -2" Polished End Fitting 3 VALVES Butterfly Valve Gruvlok Model 7700FP 2 Grooved Check Valve Gruvlok Model 7800FP 2 Grooved Ball Valve Grinnell Fig. 1550 1 /2 " -2" Threaded Deluge Valve Grinnell Model F470 4" External Resetting Flange by Flange 4 HANGERS Swivel Hanger Ring Grinnell Fig. 69 1 /2" -8" Beam Clamp Grinnell Fig. 92 3/8 " -1/2" Hilti HDI -P 3/8" 5 EARTHQUAKE BRACES Quick Clamp Topco Fig. 220 1" -2 Quick In -Line Topco Fig. 230 1 " -2'/2" Quick End Topco Fig. 225 1 " -1 1 /4" Quick 4 -Way Topco Fig. 240 1 " -1 1 /4" 6 SIGNALING/TESTING Flow Switch Potter VSR -F 2 "" Electric Bell Potter 6" Sight Flow Connection Grinnell Model #F1321 1 " -2" 7 PRE ACTION — DELUGE CONTROL PANEL By Others Submittal Data Sheet ' ji N1 per 40 9 /Dyna- Thread Stamp sere Line Sch-40 Replacement ■ Super a0 /Dena- Thread sprinkler pipe represents an engineering advancement for the sprinkler • pipe industry. It combines the safety and lunge.- icy of traditional Sch -40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Super 40 /Dyna- Threads inside diameter is up to 3.6(1- larger than Sch -a0 giving it superior hydraulics. Also. when used in combination with Dvna -Flow pipe. down sizing often occurs. Super 10 /Dyna -Thread is fully listed and approved UL. ULC. and FM for tire sprinkler applications. The life expectancy of Super 40/Dyna -Thread and Sch -40 are • - = i-.3 .'- a:` = ?� "• ;r equal based on the calculated wall thicknesses per UL (see CRR). The consistent quality of ;reel ' -"' -=- :-4, ,W l: ':.: -''Y� ._ _ 1_ used to m Super 10 /Dyna -Thread facilitates smooth threading and lower maintenance costs. -- `' ' The exterior of Super 40 /Dyna -Thread is protected by a clean. durable mill coating for extended '. • _ a . shelf life and easy paint application. With its increased strength and lighter weight. Super40/ :y a 3 - i g ; :. - Dyna -Thread reduces installation ,fatigue and is ideal for retro -tit applications. Corrosion {�"i.- • <` •`- II 7 :. - a: d . 7; Resistance Ratio (CRR) is a Li. t Undcr.vriters Laboratory) term for the estimated life expectancy :� _ of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread. A assumed to be the weakest point of the pipe length. Super 40/Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread :CRR =1.001 gives 1 Super 40 /Dyna -Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe. Super 40 /D•na -Thread has no thread gauge warning. Super 40/ _ I 1 . I Dyna -Thread is approved for standard hanger spacing (15 ft. O.C. I. can be used as earthquake - I • sway bracing. and is safe to use as drops. Super 40 /Dyna -Thread is safer to weld un than many _° zinc - coated lightw•all threadable pipe products. Super 40 /Dyna -Thread is more widely accepted � �. • than lightwall threadable where Sch - is specified.: • Specifications & Approvals .. a Suner40 /Dvna -Thread pipe is manufactured to ASTM A 135. Grade A and is in compliance .4FPA -13. All sizes of Super 40 /D -Thread are rated at 300 psi working pressure. Super 10/ Dyna- Thread is 1.:L and 1.1 Listed for wet. dry . and pre - action sprinkler systems and FM Approved Specifications .. =incises +c for use in wet systems. Super 40 /Dyna -Thread can be "hot -dip' galvanized to meet FM requirement Product Nominal Wt/Ft Wt /Ft Pcs/ Wt /Lift Wt; Lift Wt /Lift for dry systems. Super 40 /Dyna -Thread is approved NPS I.D. HaO Filled Lift 21' 24' 25' for all threaded couplings and welded outlets and is x 1'• 1.080 1.330 1.75 70 1955 223 232' suitable for all roll - grooved. and plain -end fittings. *25 27.4 2.0' 2.60 70 88- 1013 1056 (See listing information). x 1 1/4" 1.408 1.870 2.54 51 2002 2288 238 .32 35.8 2.8 - 3.78 51 908 1038 1081 x 1 1/2 1.639 2.290 3.22 4a 2115 2415 2519 UL MI ® .40 41.6 3.4 4.79 44 9 5 ? 1097 11 =3 x 2" 2.104 3.050 4.57 3C 1921 2196 22S Uama Approved urea * 50 53.4 4.5 6.80 30 871 996 1027' American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall famil} of products although they have different names are the same in all respects with regard to strength. weight. bundle count, listings and approvals. For example. D � na - Flory and Super Flo are the same product as are Dyna Thread and Super 40. `CL is manufactured with Exterior galvanized coating. BLT is manufactured nith 3Iacl lacquer coating. Project: Sprinkler Contractor: Ca :e. c.ngineer: Specification Reference: System Tyce: Locations: Comments: Submittal Data Sheet , r Super Flo° /Dyna -Flowe Stamp He's • . , h Strength Steel Pipe Super Flo/Dyna-Flow pipe is the - original" high - strength lightwall sprinkler pipe. Super Flu/ . Dyna -Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule - H) pipe. Lightweight. easy to cut and easy to handle for installation. Super Flo /Dyna -Flow is a valuable addition to any fire protection system. Additional Benefits Lightweight and easy to install. resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hunger spacing i I it O.C. I per NFPA. Available in Standard lengths for your convenience. or can he ordered in custom • lengths upon approval. Fast cutting and welding. as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean. durable mill coating t•;: = - f: a r . :.; ,.a _- provides longer ";hell life' and acts as an excellent primer for custom paint applications. 9 _ ` ' S' ?7 • , Superior Hydraulics With an inside diameter of up to I lei- larger than Schedule 40 and up 'lam ' 7 t ;` r'D i r to 74°c larger than Schedule l0. Sup erFluiDgn❑ - PP P B Flow i e hydraulic; are rice tiunal. Larger ID.s - ' , I i s "` -- enable Super Flo /Duna -Fluty. and related components. to be down -sized within the system. thus iiii increasing the potential for job cost savings. For complete Hazen - Williams charts. refer to "Super Flo/ ' ' Dyna -Flow Hydraulic Data Tables:' = _1 ` ' 4::f.:: : Coatings & Fabrication Super Flo /Dyna -Flow products are coated with an environmentally i• r approved and specially formulated modified - acrylic or water -bused coating. This durable coating is . paintable. The black coating acts as an excellent primer and is resistant to weathering and L.V. 3 ei degradation from outdoor storage. . Metallurgical properties provide excellent fabrication characteristics for end prep finishes. welding l • and roll grooving. No special process or equipment are needed for fabrication and installation. e Specifications & Approvals Super Flo /Dyna -Flow pipe is manufactured to meet ASTMI I x : A 795 Type E. Grade A and are in compliance with NFPA -1= and NFPA -14. All sizes of Dyna a b'! u; Flow /Super Flo are L•L Listed. FM Approved and L'LC Listed. - t7. a. Super Flo/Dyna-Flow is L'L /CLC Listed for use with roll grooved. plain -end couplings. and ' .. et7 welded joints for wet. dry. pre - action and deluge systems. It is FM Approved for roll grooved. • plain - ended, and welded joints for wet systems. Refer to appropriate documentation for up -to -date I' . and approval information. Super Flo/Dyna-Flow is now available - hut-dip - galvanized and - :en specifically approved by FM for dry systems uses. Specifications =Inches * =Metric American Tube and Pipe was acquired by Product Nominal Wt/Ft Wt/Ft Pcs/ Wt /Litt Wt /Lift Wt /Lift Allied Tube and Conduit on February 1. 1997. NPS I.D. H2O Filled Lift 21' 24' 25' The engineered lightwall and standard wall x 1" 1.191 0.830 1.31 91 1586 1812 1888 family of products although they have different * 25 30.3 1.2 1.95 91 719 822 856 names are the ame in all respects with regard to x 1 1/4" 1.536 1.059 1.87 61 1356 1550 1615 strength. weight. bundle count. listings and .32 39.0 1.6 2.78 61 615 703 733 approvals. For example. Dyna -Flow and Super x 1 1/2" 1.728 1.667 2.71 61 2135 2440 2542 Flo are the same product as are Dyna Thread * 40 43.9 2.5 4.03 61 968 1107 1153 and Super 40. XL is manufactured with Exterior x 2" 2.203 2.104 3.79 37 1634 1868 1946 galvanized coating. BLT is manufactured with .50 56.0 3.1 5.64 37 741 847 883 Black lacquer coating. x 2 1/2" 2.703 2.564 5.10 30 1615 1846 1923 *65 68.7 3.8 7.59 30 733 837 872 r x 3" 3.314 3.387 19 1351 1544 1608 � i ; l j 10.69 � * 80 84.2 5.0 10.69 19 613 700 729 UU LC x 4" 4.310 4.473 10.86 19 1784 2039 2124 Usiee aeorovea 1o51ea *90 109.5 6.7 16.16 19 809 925 963 II ITT \/� ( 0 10 1620 1851 1928 ("(, 9 10 735 840 875 Project: Sprinkler Contractor: rvz.:= Engineer Specification Reference: System Type: Locations: Comments: GRINNELL • GRUVLOK IIIIIINSUlp GRUVLOK FITTINGS DR GROOVED END PIPE ..._ r .. Flow Data ) - �1 �4 NEns Frictional Resistance (Expressed as Equivalent Straight Pipe) Nominal Pipe Pipe Wall Eibows Tee 90' 45' Branch Run Size O.D. Thickness I Gruvlok fittings are available through 24" Inches Inches Inches Feet Feet Feet Feet nominal pipe size in a variety of styles. These fittings are designed to provide minimum pressure drop and 1 I 1.315 I 0.133 1.7 0.9 4.4 1.7 • uniform strength. 1'/. I 1.660 0.14 I 2.3 i 1.2 5.8 2.3 Depending on styles and size, Gruvlok fittings are provided in various materials including malleable iron, 1v: t900 0.145 2.7 1.3 6.7 2.7 ductile iron, forged steel or segmentally welded steel. 2 2.375 0.154 3.4 1.7 8.6 3.4 6 Pressure ratings of Gruvlok standard fittings conform 21/2 2.875 0.203 4.1 2.1 I 10.3 I 4.1 hose of Fig. 7001 Gruvlok couplings as shown on ,age 13. 30D 2.996 0.197 4.3 2.2 10.8 4.3 Material Specifications 3 1 3.500 0.216 5.1 2.6 12.8 5.1 4 4.500 0.237 6.7 I 3.4 16.8 6.7 Cast Fittings: Ductile iron conforming to ASTM A -536 4 OD 4.252 0.220 6.4 3.2 16.1 6. or Malleable iron conforming to ASTM A -47 5 5.563 0.258 6.4 4.2 21 � 8.4 i Steel Fittings: 54.0D 5.236 0.248 8.0 4.0 20.1 I 8.0 Forged steel, conforming to ASTM A -106, Gr. B 5'h OD 5.500 1 0.248 I 8.3 4.2 ( 20.9 1 8.3 For other metals contact Grinnell . 6 6.625 0.280 10.1 5.1 25.3 10.1 Segment Welded Steel Fittings: 6 OD 6.260 0.280 9.7 I 4.9 I 24.3 9.7 1 -4" Carbon steel, Schedule 40, conforming to ASTM A -53, Type F 6'h OD 6.500 0.280 10.0 I 5.0 24.9 I 10.0 5 -6" Carbon steel, Schedule 40 conforming to ASTM A -53, Type E or S, Gr. B 8 8.625 1 0.322 I 13.3 6.7 33.3 13.3 8 -12" Carbon steel, Schedule 30, conforming to 10 10.750 0.365 I 16.7 i 8.4 41.8 16.7 ASTM A -53, Type E or S, Gr. B 14 -24" Carbon steel, 0.375 wall, conforming to 12 12 1 0.375 I 20.0 10.0 I 50.0 I 20.0 ASTM A -53, Type E or S, Gr.B 14 14.000 i 0.376 22 13 6 I 22.9 Adapter Flanges: 16 I 16.000 0.375 26.4 15.e 73.9 26.4 Class 125 - cast iron conforming to ANSI B -16.1 _ -= Class 150 - carbon steel conforming to ANSI B -16.5 18 18.000 0.375 31.1 18 87.2 . 31.1 Class 300 - carbon steel conforming to ANDI B -16.5 ® c oatings: 20 20.000 0.375 1 0.375 34.8 i 20.9 97.3 34.8 24 24.000 40.4 24.2 113.0 I 10.4 Rust inhibiting lead -free paint. ,: I Color: ORANGE (Standard) For the branch of tee that is either increased or reduced in size, use the value that is RED (Optional) corresponding to the branch sdize. Hot - dipped zinc galvanized (Optional). Example: for 6• x 6" x 3" tee, the branch value of 3• is 12.8 ft. (3.9). For other coatings contact Grinnell. For sizes not listed interpolate from the values shown. 21 • GRINNELL • GRUVLOK • ELBOWS Fig. 7050 Fig. 7051 Fig. 7052 4 (CAST) C to E . T� r Ct oE` C to E •'� C to E fie : C to E; .... w ;% �i 4 i . � � _ ..ate f ". rt (WELD) Fig. 7053 4 ,, .... ° Er. Fig. 7050 90° Elbow' Fig. 7051 45' Elbow' Ag. 7052 22 Elbow Ag. 7053 1 /f Elbow Fig. 7050 LR I Fig. 7051 LR 90° Long Radius Elbow' 145' Long Radius Elbow' Center Approx. Center Approx Center Approx. Center Approx. Center Approx. Center Approx. Nominal To Weight To Weight To Weight To Weight To Weight To Weight Size End Each End Each End Each End Each End Each End Each Inches Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. 1 2 c 0.6 1 c 0.6 I 1e/s 0.5 1 0.3 3 0.9 2 0.7 1 2 C 1.1 13/4 C 0.8 1 0.7 1 N 0.5 re 1.3 2' 1.0 1 2 C 1.3 1 C 0.9 1 0.8 1 0.7 04 1.7 2 1.2 • 2 3 C 1.6 2 C 1.5 • 178 C 1.5 12e 0.9 4 C 2.5 2 1.7 2 4 C 3.9 2 C 3.5 I 2 1.9 1 1.5 53 4.9 3 I 2.9 3 4 c I 2.9 21/2 C 2.1 I 2 C I 3.2 I 1' /z 2.0 Pe C 6.5 33/s I .3 3 4 C 5.9 2 C 4.6 I 2 I 4.0 I 1 2.8 7 9.7 3 I 5.3 4 5 C 7.2 3 C 6.1 21e C I 5.3 1 3.3 7 C 11.5 4 I 7.2 5 5" c 11.6 3 C 8.5 2 7.2 2 5.0 9 20.9 5 12.2 6 6112 C 17.6 3 C 11.7 3'/8 C 8.2 2 I 6.5 11 29.1 5'/2 17.4 8 77 c 31.0 4 c 19.8 318 C 17.8 2 I 10.0 15 59.2 7 34.0 10 9 C 53.0 4 c 34.1 4 30.0 2 14.5 18 104 8' 57.4 12 . 10 C 78.2 5 C 46.3 4 40.4 2 18 21 147 10 82.6 14 11 90.0 6 55.0 I 5 46.0 31/2 I 32.1 24 184 8 I 79.6 16 12 113.0 71 77.0 I 5 52.2 4 I 42.0 27 239 10 I 104.3 18 151/2 I 164.0 8 96.0 I 5 65.0 4 53.2 30 291 11 132.5 20 17 203 9 I 120.0 6 80.0 5 65.7 I 33 361 12 164.0 24 20 284.0 11 I 176.0 6 96 7 112.0 96.0 I 39 547 15 I 237.0 C - Cast malleable or ductile iron, all others are segment - welded steel. '14• - 24• Standard Radius 90° & 45° Elbows and all Long Radius Elbows are available in forged steel fabrications. Center to end dimensions and weights may differ from that shown in the chart. Contact Grinnell for details. Qi 22 GRINNELL • GRUVLOK U Long 7050 -3D 7050 -30 _ 7057 -30 I 7051 -3D I 7058 -30 I 7052 -30 I 7053 -3D Nominal Fitting 90° 60° 45' 30' 221/2' t 1 v,' '. a d i u s Size I 0.0. C to E Wgt. Each C to E IWgt. Each C to E Wgt. Eacn I C to E 'Wgt Eacn C to E IWgt. Eacn C to E Wgt. Eats. Inches Inches Inches Lbs. Inches Lbs. Inches 1 Lbs. Inches Los. Inches inches Inches Inches I i Elb ows 2 I 2.375 I 10.00 I 5.3 I 7.50 I 3.3 6 50 I 39 I 5 75 3 4 I 5.25 i 3.2 I 4.50 I 2.3 2 "2 12 375 11 50 9 5 8.25 I 7.7 1 25 I 5 7 ! 5 30 5 3 I 5.50 5 3 1 4 75 I 4 6 c Fig. 7050 30,5D,60 3 I 3.500 I 1300 14.0 9.25 I 110 7 'S 3.5 I 630 , 30 5'5 I 7 3 5.00 6.2 3'4 4.000 14 50 I 18.6 10.00 14 4 3.50 1 12 3 5.73 I 10 2 5.00 9.2 15 00 7 6 1 Long radius elbows 4 I 4.500 16.00 24.1 ` 11.0 18 5 9.00 15.. 7 25 I 12.3 I 6 50 I 11 : 5.15 I 9 3 30, 5D and 6D in sizes 5 5.563 I 20.00 I 40.9 I 13.75 31 3 I 11 25 26 5 I 9 00 21 3 ( 8 00 19 = 6 50 I 15 3 up to and including 4" 6 I 6.625 24 00 63.7 16.50 1 48.3 13.50 41 3 I 10 75 i 33 3 9.50 I 30.1 7 75 I 24 6 are provided with 4" 8 8.625 32.00 127.8 22.00 97 9 18 00 I 82.9 14 50 68 0 12.75 I 50 5 10 50 I 49 3 (101,6 mm) long inte- , I gral tangent. Remain-.. I 10.750 40.00 226.4 I 27.25 I 173.4 I 22.50 I 146.3 I 18.]0 2e 5 t6 ?0 107 2 13.00 87.3 ing sizes provided with 1 2 ( 12.750 I 38.00 332.7 I 32.75 254 3 I 27 00 215.9 I 21 75 • 177 0 I 19 25 I 157 5 15.50 I 128.3 integral tangents with t4 I 14.000 I 56.00 427.3 I 38.25 I 327 3 I 31 50 I 227 3 25 25 I 227 3 I 22 50 I 202 3 18 25 I 164 3 lengths equal to nomi- 16 16.000 I 64 00 560.1 43.75 329.0 36.00 I 363.5 I 29 00 1 297 3 25 50 I 255 2 20.75 I 216.0 nal pipe size. 18 18 000 72.00 I 710.7 49.25 544.4 4050 I 461.3 I 32.50 I 373.1 I 28.75 I 336 5 21 35 274 + 20 20.000 80.00 I 879.3 54.75 I 673.5 I 45.00 I 540 7 I 36.00 I 467 3 32.30 416.3 26 00 339 2 24 I 24.00 96.00 1 1270.3 65.50 I 973.0 I 53 75 I 824.4 43 25 I 675.7 38 25 I 601 4 31 00 I 490.0 7050-5D 7050 -50 7057 -50 I 7051 -50 7058 -50 7052 -50 7053 -30 Nominal Fitting 90° 60' 45' 30' 221/2' 11 plain -end Size 0.0. C to E Wgt. Each C to E Wgt. Each C to E ' Wgt. Eacn C to E !Wgt. Each C to E Wgt. Eacn C 10 E IWgt. Eacn 2. Grooved or P Inches Inches Inches Lbs. Inches Lbs. Inches Lbs. I Inches 1 Lbs. Inches Inches Inches Inches available - specify . choice on order. 2 2.375 14.00 I 7.2 I 9.75 5.6 I 3.25 I 4.8 I 6.75 I 4.0 6 .00 I 3.0 5.00 I 3.0 2' 2.875 16.50 13.3 I 71.25 10.2 9 25 I 8.6 I 7.50 I 7.0 I 6.50 I 5.2 5.25 I 5.0 3. Material: standard wall 3 3.500 19.00 19.9 12.75 15.0 I 10.25 I 12.5 8.00 ( 10.0 I 7.00 3.8 5.50 6.9 steel pipe to ASTM 31/2 1 4.000 21.50 26.3 74.25 20.0 I 11 25 16.5 8.75 I 13.0 7.50 11 3 5.75 I 8.7 A53, Grade B. (Other 4 4.500 24.00 I 35.4 15.50 26.0 12.50 I 21.3 9.50 16 5 8.00 1 3 6.00 10.7 materials available on 5 5.563 30.00 60.0 19.50 44.1 15.50 I 36.1 I 11.75 I 28.1 10.00 I 24 1 7.50 I 18.2 request). 6 I 6.525 36.00 93.5 23.25 68.6 ( 1850 I 56.2 14.00 I 43.3 I 12.00 I 37 5 9.00 28.3 4. Bends to conform to 8 8.625 48.00 187.6 I 31.00 137.7 24 30 112.8 I 18.75 87.9 I 16.00 75. 12.00 56.3 above radii. 10 10.750 60.00 332.4 39.00 I 244.1 I 30.75 199.9 23.50 I 155.3 20.00 133.7 15.00 100.6 12 12.750 72.00 488.4 46.75 I 358 6 I 37.00 293.7 28.00 228.9 I 24.00 196 4 18.00 I 1 3 5. C to E tolerances: 2" 14 14.000 84.00 627.4 54.50 460.7 43.00 377.3 I 32.:5 I 294.0 I 28.00 , I 252 3 21.00 189.3 through 6" ± 1/8" (3,2 16 16.000 96.00 822.2 62.25 603.3 39.25 494.5 37 50 385.3 32.00 I 330.7 24.00 I 248.3 mm); 8" through 16" ± 18 18.000 108.00 1043.4 70.00 766.2 55.25 627.6 32.25 489 0 36.00 419.7 27 00 I 315.7 1/4" (6,4 mm); 18" 20 1 20.000 120.00 1290.9 77.75 947.9 61 50 I 776.4 46.75 605.0 40.00 519.2 30.00 390.6 through 24" + 3/8" (9,5 mm). 24 24.00 144.00 1864.8 93.25 1369.3 I 73.75 I 1121 6 56.25 873.3 I 48.00 750.1 35.75 I 564.3 7050 -6D 7050 -60 7057 -60 I 7051 -6D I 7058 -60 7052 -80 7053 -60 Nominal Fitting 90° 60° 45' 30° 22'12' 11'7,' Size 0.0. C to E Wgt. Each C to E Wgt. Each C Io E Wgt. Each C to E Wgt. Eacn C to E Wgt. Each C to E Wgt. Eacn Inches Inches Inches I Lbs. Inches Lbs. Inches Lbs. Inches Las. Inches Inches Inches Inches 6. All weights are approx- imate, based on calcu- 2 1 2.375 I 16.00 I 8.2 1 11.00 6.3 9.00 I 5.3 I 7.25 4 3 I 6.50 I 3.9 I 5.25 3.2 lated weight of pipe. ' 217 I 2.875 19.00 15.2 12.75 11.4 10.25 I 9.5 I 8.00 ; 7 ' I 7 00 6.7 5.50 5.3 3 3.500 22.00 I 22.9 14.50 17 0 1.50 I 14 0 3.75 11 0 I 7.50 9.5 I 5.75 I 7.3 3'h 4.000 25.00 I 31.1 16.25 I 22.3 12.75 18.6 9.75 I 14 4 3.25 12.3 6.00 I 9.2 4 4.500 28.00 41.1 18.00 29.8 14.00 I 24.1 10.50 I 18.5 8.75 15.7 6.50 I 11 4 5 5.563 35.00 69.6 22.25 50.5 17.50 I 40.9 I 13.00 I 313 11.00 26.5 I 8.00 19.4 6 6.025 I 42.00 *08.4 I 26.75 78.6 2100 63.7 I 15.75 483 13.25 I 41 9.50 I 30.1 8 8.625 I 56.00 217 5 35.75 157.7 28.00 127.3 21.00 1 97 9 17.50 I 82.9 I 12.75 I 60.5 10 10.750 70.00 385.4 44.75 279.4 35.00 226.4 I 26.00 173. 22.00 I 746.9 16.00 107 2 II 12 12.750 84.00 566.2 53.50 I 410.5 41.75 332.7 I 31.25 I 254 3 26.25 , 215.9 19.00 157.5 14 14.000 98.00 727.4 62.50 527 3 48.75 427 3 36.50 327.3 30.75 277 3 I 22.25 I 202.3 16 16.000 I 112.00 953.3 71.50 691.1 55 75 560.1 41.75 429.0 I 35.25 363.5 25.50 265 2 18 18.000 I 126.00 1209.7 80.50 877.1 62 75 710.7 47 00 I 544 4 39.50 461 3 28.75 336.5 20 20.000 I 140 00 1496.5 89.25 I 1085.1 69.75 879 3 52.25 573.5 44 00 570.7 31.75 416.3 24 I 34 00 I 168 00 1 2162.0 107 25 I 1567 5 33.75 I 1270.3 I 62.50 I 973.0 52.34 I 624 4 38.25 I 601 4 23 GRINNELL • GRUVLOK A TEES REDUCING TEES C to E .,••....,.....,........1 I I -- z: ... 4. . - I 1 ••.......,4.4...............„ Illw 1 I .,...F...:ar.-1.:_c:...!.).:11 II .11 J... i .., ._. L± ;4,.. ...,,____.....i.....„ 0. I ..,...... ...... 1 ...,.:1.4.,,......,1 •• •,:.. L________ Reducing Tee Reducing Tee - I 11111111 Fig. 7061 Fig. 7064 Fig. 70611 Fig. 7064 Std. w/Tbd. Br. SW. wind. Br.1 Nominal Center Center Approx. Nominal Center Center Approx. Size To End To End Wt. Each Size To End To End Wt. Each Inches Inches Inches Lbs. Inches Inches Inches Lbs. 7'1 -,... .11;1 tg. --- r(71 .317 2x2x1 3% C 31/4 C 2.6 10x10x6 55.0 : • : : - - r • • : • . 9 9 :, - • - - - • Fig 7060 Fig 7063 2x2x1' 31/4 3% 2.7 10x10x8 9 . C C . . : :, • _- Tee Tee with Threaded Branch 21/2x21/2x2 33/4 33/4 4.4 12x12x3 10 10 84.9 Center Approx. Center to Center to • • - r' ••, ] :•:. : -- - - • • Nominal to Weight Grooved Threaded Approx. 3x3x1 41/4 41/4 7.0 12x12x4 10 10 85.8 Size End Each End End Wt. Each Inches Inches Lbs. Inches Inches Lbs. 3x3x1V2 41/4 41/4 I 5.3 12x12x5 10 • 10 87.0 - - - - 1 2'/4 C 1.0 21/ 21/4 0.9 3x3x2 41/4 41/4 I 5.5 C - • • 1 10 • 10 88.3 11/4 2 k 1.2 2 23/4 1.4 3x3x21/2 41/4 41/4 5.8 12x12x8 10 10 91.2 •:: • . 11/2 23/4 C 2.0 23/4 . 23/4 1. 4x4x1 33/4 33/4 7.0 12x12x10 10 10 94.8 2 3 c 2.9 3'/4 . 41/4 2.9 4x4x2 5 5 10.2 14x14x8 11 11 1 109.6 . .. 2 41/4 C 5.6 33/4 3?/.1 4.7 4x4x21/2 5 5 11.2 14x14x10 11 11 113.5 • ._. 3 4. C 5.7 . 4 1 /4 : 6 8.1 . 4x4x3 5 - - 5 11.4 14x14x12 11 11 116.5 C - - 3'/2 4 c 9.8 4 41/2 8.8 5x5x2 51/ 51/2 14.5 16x16x8 12 12 135 4 5 C 12.3 5 71/4 13.5 -- . .5x5x3 5 51/2 16.1 16x16x10 12 12 139 5 51/2 c 17.7 . 51/2 5 16.7 5x5x4 51/2 c 51/2 c I 1 16x16x12 . 12 I 12 142 6 61/2 C 26.8 6 61/2 25.6 -:• -- 6x6x2 61/2 61/2 26.4 18x18x10 151/2 151/2 204 8 73/4 C 39.2 73/4 7 45.0 . ... _ ... -. 6x6x2'h 61/2 6 26.5 18x18x12 151/2 15'/2 209 10 9 C 74.2 -.9 .9 73.0 6x6x3 12 10 C 94.1 10 10 98.0 61/2 61/2 26.5 18x18x14 151/2 1 211 C 14 11 11 6x6x4 6½C 61/2 26 - . - 5 18x18x16 151/2 216 . - 16 12 146 6x6x5 61/2 6 28.0 20x20x14 171/4 - 258 ., • „ ., . 18 151/2 218 8x8x2 73/4 7 37.5 20x20x16 171/4 263 ... 20 171/4 275 8x8x3 7 73/4 38.7 20x20x18 17 - 278 • .., :...!•:;.";-..,::: •i':.. : - .15 : - - '..: ' ::• 7 • . • .: 24 20 379 8x8x4 73/ c 50.0 24x24x8 20 20 I 334 . . . .... 8x8x5 73/4 7 41.0 24x24x10 20 20 1 342 C - Cast Malleable or Ductile Iron. all others are Segment-Welded Steel ,:Gyi"f;c2: '36.3 '.::,:, '3 ::' _ . 8x8x6 73/4 r 73/4 54.0 24x24x12 20 20 I 349 '9F. :' ":i.3 ? 2-: i - ; , ::I:•' . :,_.:..' : :2 :.: i : . --: : 10x10x2 9 9 ....: 61.8 24x24x1 .., 20 .: _ 1 3 10x10x3 9 9 63.0 24x24x16 20 35 222.3 221 - 3 :.5 i i. .:::: ... '; ::.. : - 10x10x4 9 9 64.0 24x24x18 20 362 :5 22? i 22'i i 22 -- - 10x10x5 9 9 65.1 24x24x20 20 367 '..G 223 i 22? i 'r '47,C. ,-'.: ,•-::,. .,,,: C - Cast Malleable or Ductile Iron, all others are Segment-Welded Steel. 24 11■1111■111111■11•11■1■1111■11.11■1 i. ..: Gruvi ► : G ' ' ,-:, `; WI OIE -SO -ITT PIPING M ETHOD �' ' 3RUVLOK SOCK -IT PIPING METHOD ; S The Gruvlok Sock -It Piping Method provides a quick. secure and reli - -.. able method of joining plain -end steel pipe. Several Sock -It i configurations are available: tees with NPT outlets. reducing run tees with NPT outlets. straight couplings. 90 elbows. straight tees and re- ducing elbows. Pressure energized elastromeric gaskets provide the Sock -It with a leak -tight seal. Specially designed lock bolts secure the I ij ®O pipe in the Sock -It Fitting, providing a fast, dependable way of joining \ . tr• • For fi re protection service small diameter plain -end pipe. , contact Gruvlok NOTE: All Sock -It fittings are UL/ULC listed and FM approved for 175 — - 4— psi working pressure when used to join Allied XL Pipe. Super Flo and Dyna -Flow Pipe. Material Specifications: Housing: FITTING SIZE Cast iron ASTM Al26 CLASS A Nominal Pipe Nominal Pipe Bolts: Size 0.0. Size 0.0. Case hardened carbon steel. dichromate finish. Inches Inches Inches Inches ON/mm mm ON /mm mm Gaskets: '/i 0.840 1',2 1.900 EPDM, as specified in accordance with ASTM D2000 1.050 2 2.375 • The Fitting Size Chart is used to determine the OD of the pipe that the 1 1.315 2V2 2.875 fittings is to be used with. Gruvlok Fittings are identified by either the Nominal size in inches or the Pipe OD in mm. 1% 1.660 ) Fig. 7100 - 90° Elbow (Sock -It x Sock -It) C to E l.___ U -_. w-:---- y -- -.1 "-v-r-j:Ar7::';`:.' - ' ' :','.., ',-- 1 /,:.', : ji;:x . ? P 4 . ^ T i FIGURE 7100 SOCK -IT ELBOW e Working Pressure* Dimensions , UL/ULC FM Center Approx. c Nom. Size Pipe OD Listed Approved To End U" W Y Wt. Ea. rn In./ONImm) In. /mm PSI/bar PSI/bar In. /mm /n. /mm In.imm In. /mm Lbs. /Kg 1 1.315 300 300 2 /la '/a /As 1;': 1.9 1'/4 1.660 300 300 2 %e 1 1'% 11 2.3 11/2 1.900 300 300 23/4 We 1','e 1'%t6 2.7 2 2.375 175 250 31/2 1°/,a 1% 2%e 4.0 • Rated working pressures are based upon compliance with UL. ULC. and FM pressure test requirements on Sch. 10 or heavier wall steel pipe. '" "U" - Run take -out dimension. - 79 - GRUVLOK 50 Ift -PiP ETh - . _ - -- ..::Gruvlo C .. Fig. 7101 - 90° Reducing Elbow (Sock -It x NPT) C to TE I in •--- IOW ,....,...--y —�j T ! i ' I jCtoSE ±:r` i V FIGURE 7101 SOCK -IT REDUCING ELBOW • Working Pressure' Dimensions UL/ULC FM Center Center Approx. Nom. Size Listed Approved to TE To SE U" T" W Y Wt. Ea. In./DN(mm) PSI/bar PSI/bar In. /mm In. /mm In. /mm In. /mm In. /mm In. /mm Lbs./Kg 1 x' /2 300 300 1's 26 '/e 1 ' /,6 1 "As 1.7 1 x 3 /4 300 300 1'As 2 '1/2 '/a "As 1"/,s 1.6 1 x 1 300 300 l' /,s 2 /,s '/e '/s " /,a 1` /,s 1.5 11/4 x 1/2 300 300 1 /.s 21/2 " /,s 11/2 1'h 1' /,s 2.2 1' /4 x'/4 300 300 1 /,s 21/2 "/+s 1 11/4 1 2.1 11/4 x 1 300 300 1 21/2 " /,e 1 1 1' 2 11/2 x'h 300 300 1"/,s 2'/2 1 11/4 1%6 1i /,s 2.5 11/2 x' /., 300 300 1 " /,s 21/2 1 11/2 1' /a 1' 2.4 41 11/2 x 1 300 300 1 "A6 21/2 1 11/2 1' /a 1' 2.3 'Rated working pressures are based upon compliance with UL. ULC. and FM pressure test requirements on Sch. 10 or heavier wall steel pipe. C to SE - Center to Sock -It End • ""U" - Take -out dimension. Sock -It End. C to TE - Center to Thread End ' - Take -out dimension, Thread End. Fig. 7103 - Straight Tee I Z i** 1 . 1,r� ."..-'1 I _ : :1st , -\ ../ HuH FIGURE 7103 SOCK-IT STRAIGHT TEE Working Pressure' UL/ULC FM Dimensions Approx. Nom. Size Pipe 00 Listed Approved "T U" V W Y Z Wt. Ea. In./011(mm) In. /mm PSI/bar PSI/bar In. /mm In. /mm Inimm In. /mm In. /mm In. /mm Lbs./KL__ 1 1.315 300 300 "As 1 /e 2'/, "As 1 "/,s 41/2 2.3 11/4 1.660 175 300 1 2 2' /,s 11/4 1' 41/2 2.9 11/2 1.900 175 300 " /,s 21/2 2 /,s 1 /e 1 i 51/2 3.4 2 2.375 175 250 15 /16 2% 3 1" /,s 2' /is 6 5.6 i • Rated working pressures are based upon compliance with UL. ULC. and FM pressure test requirements on Sch. 10 or heavier wall steel pipe. " "T" - Outlet take -out dimension. "- "U" • Run take -out dimension. - 80 -