Loading...
Plans B Bulletin 136 Rev.O co I. - ® Model F1FR ciF . rieliable Model F1FR Recessed Quick Response Sprinklers o Model Fl FR Sprinkler Types Standard Upright "1 ;' +`:` Standard Pendent ; ,- =ti C 1 0351. onventional 1 °, Vertical Sidewall ( 7 Horizontal Sidewall _ _ _ - _ __ - - HSW 1 Deflector Model F1FR Recessed Sprinkler Types; _ - '� Recessed Pendent Upright Pendent Recessed Horizontal Sidewall — HSW 1 Deflector ,, .. • r4h . ;,..;:. Listings & Approvals .. 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada (ULC) y f• 3. Certified by FM Approvals . 4. Loss Prevention Council (LPC, UK) °�. • 5. NYC BS&A No 587 -75 -SA - L`, I' 6. Meets MIL- S -901C and MIL -STD 167 -1 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258 -93 -E - UL Listing Category _ ____ _ _ __ _ _ Vertical Sidewall Conventional Sprinklers, Automatic & Open Quick Response Sprinkler - UL Guide Number VNIV -_ r ` ii *" cp i i i L� Patents: US Patent No 6,374,920 Applies to *� ':= . , . !_ Model F1FR Vertical Sidewall Sprinklers. -4 . -� Product Description Horizontal Sidewall Recessed Pendent Reliable Models F1FR and F1FR Recessed Sprinklers are HSW 1 Deflector (Model FP Shown) quick response sprinklers which combine the durability of a pands, forcing the bubble smaller and smaller as the liquid standard sprinkler with the attractive low profile of a decorative pressure increases. Continued heating forces the liquid to sprinkler. push out against the bulb, causing the glass to shatter, The Models FIFA and Fl FR Recessed automatic sprinklers opening the waterway and allowing the deflector to distrib- utilize a 3.0 mm frangible glass bulb. These sprinklers have ute the discharging water. demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This Application quick response enables the Model F1FR and F1FR Recessed Quick response sprinklers are used in fixed fire protec- . sprinklers to apply water to a fire much faster than standard tion systems: Wet, Dry, Deluge or Preaction. Care must be sprinklers of the same temperature rating. exercised that the orifice size, temperature rating, deflector The glass bulb consists of an accurately controlled amount style and sprinkler type are in accordance with the latest of special fluid hermetically sealed inside a precisely manu- published standards of the National Fire Protection Asso- factured glass capsule. This glass bulb is specially con- ciation or the approving Authority Having Jurisdiction. structed to provide fast thermal response. The balance of Quick response sprinklers are intended for installation as parts are made of brass, copper and beryllium nickel. specified in NFPA 13, FM Global Loss Prevention Data At normal temperatures, the glass bulb contains the fluid Sheet 2-8N or other applicable standards. Quick response in both the liquid and vapor phases. The vapor phase can sprinklers and standard response sprinklers should not be be seen as a small bubble. As heat is applied, the liquid ex- intermixed. The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523 Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers ,.Installation Wrench: Model D Sprinkler Wrench Installation Data: K Factor Sprinkler Approval Sprinkler Number n don SlN Sprinkler Type US Metric Height Organization ( ) SSU I SSP Standard - Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position y," (15mm) Standard Orifice with 2" NPT (R 2) Thread 5.6 80 22' (56mm) 1,2,3,4,5,6,7 R3625 R3615 '54; (20mm) Large Orifice with 34" NPT (R 8.0 115 _ 2.3" (58mm) 12,3,4,7,8 83622 R3612 % (17mm) Small Orifice with y," NPT (R)) Thread 4.2 60 2.2" (56mm) _ 1,2,8 83623 R3613 98" (10mm) Small Orifice with 2" NPT (R)) Thread 2.8 40 , 2.2" (56mm) 1,2,8 83621 R3611 10mm Orifice XLH with R3" Thread 4.2 60 56mm 4,6,7 R3624 R3614 Conventional - Install in Upright or Pendent Position 10mm Orifice XLH with Rae Thread 4.2 60 56mm - — R3674 15mm Standard Orifice with y," NPT (R2) Thread 5.6 80 56mm 4,6,7 R3675 I 20mm Large Orifice with 3 /4" NPT (R 8.0 115 58mm 4,7 R3672 (1) Polyester coated upright UL and ULC listed corrosion resistant. rte �} ""- - == , ---,-;7:;':-. 415 ar '' ^ Y I; i �y y - Upright Pendent Conventional Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Approvall Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) /2 (15mm) 2" NPT (R'h) 5.6 80 2.2" (56mm) 1,2,3,4,5,7,8 R3615 ' 7/32" (20mm) 34" NPT ( R 3 A ) 8.0 115 2.3" (58mm) _ 1,2,3,8 R3612 X (11mm) 2 " NPT (R') 4.2 60 2.2"(56mm) 1,2,8 R3613 38" (10mm) 2" NPT (R') 2.8 40 2.2" (56mm) 1,2,8 R3611 10mm Ray 4.2 60 56mm 4,7 R3614 (1) Refer to escutcheon data table for approvals and dimensions. �_ 2 1/4• HOLE OIa f' 2 5/8' D14. [66.7mm] (57.Imm) HOLE IN CEILING .... __1 15/1e DM _J • 2 5/I6' 014. (58.7mm] (49.2m CUP _ = = _ ,r = �- = 2==q _, 1' 9 1/2' REDUCER I I I I X I /2" REDUCER TURN COLLAR 11' UNTIL RGHT AGAINST SPRINKLER - WRENCH BOSS \ ' Ti � 1:= // l � .L ! FACE FITTING TO ('I CEILING L =� _ J ADJUSILENT (') am 'v , i I CEILING ENSION � �1•ti� iril 1 + I 0,7 V21 FACE OF FITTING L. ` _ s� , TO FACE OF C£ILINC I DIMENSION I fJ 2mm) , I ( ) A ( ' I 111 (IJ f A (I) 1 77/J2' 011 ADJUSTMENT __ __ (72.2mm) IJ6FGO1_E I36FG05_A (I) REFER TO FI R F2 ESCUTCHEON 0ATA TABLE FOR APPROVALS AND DIMENSIONS (1) REFER TO FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. 2. Model Fl FR Quick Response Vertical Sidewall Sprinkler ,Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy . Installation Data: Nominal Thread K Factor Sprinkler Approval Sprinkler Identification Orifice Size US Metric Height Organizations Nu mbber er (SIN) Number '/" ' /z" NPT (R1/z) 5.6 80 2.2" (56mm) 1, 2, 3, 6, 8 R3685 15mm '/z" NPT (R'/z) 5.6 80 2.2" (56mm) 4 (1) (1) LPC Approval is for Pendent position only. - - Orientation Deflector to Ceiling Dimension (Min. - Max.) ?tit Upright 4" - 12" (102mm - 305mm) . Pendent 6" - 12" (152mm - 305mm) a jr Vertical Sidewall US Patent No. 6,374,920 Model F1 FR Quick Response Horizontal Sidewall Sprinkler — - -- - Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Or anizations Sprinkler K Factor and Type of Approval p Nominal Thread Sprinkler Identification Orifice Size US Metric Length Light Ordinary Number (SIN) Hazard Hazard }2" (15mm) }z" NPT(R'fz) 5.6 80 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with F1 or F2 recessed escutcheon. 136FG04 %//������� - - 4 t ( ) FACE OF FITTING r0 WALL DIMENSION ! i /4" MIN. f r'' 441%41_ z - [318mm] 6a, 1 s v;• / 'i' � s —2 1/4" HOLE DIA. — 8" 4 " -6" ,' i'I ' `ry- [57.2mmJ [f01.6mm- 152.4mmJ 311t ® r-1/ 3.2mm7 CEILING TO g)cr I � ?: x , y 1 " X 1/2" REDUCER \ DEFLECTOR . t y - - - _ 1 15/16" DIA. 1 tl _ �� I 1 � - 2711 _ Horizontal Sidewall [49.2mm] I � 2 27/32" DIA. `- I " - � [72.2mm] 1 1 i TURN COLLAR UNTIL 1X 1N AGAINST SPRINKLER L WRENCH BOSS. --"""I AWUSrMENr (I) (1) REFER r0 ESCUTHCEON DATA TABLE FOR APPROVALS AND DIMENSIONS. 3. Installation Quick response sprinklers are intended for installation as tie vacuuming. Remove any sprinkler which has been _ specified in NFPA 13, FM Global Loss Prevention Data Sheet painted (other than factory applied) or damaged in any 2-8N or other applicable standards. Quick response sprin- way. A stock of spare sprinklers should be maintained to klers and standard response sprinklers should not be inter - allow quick replacement of damaged or operated sprin- mixed. klers. Prior to installation, sprinklers should be maintained The Model Fl FR Recessed Quick Response Sprinklers are to in the original cartons and packaging until used to mini - be installed as shown. The Model Fl or F2 Escutcheons illus- mize the potential for damage to sprinklers that would trated are the only recessed escutcheons to be used with the cause improper operation or non - operation. Model Fl FR Sprinklers. The use of any other recessed escutch- Sprinkler Types eon will void all approvals and negate all warranties. When installing Model F1 FR Sprinklers, use the Model D Sprin- Standard Upright kler Wrench. When installing Model F1 FR Recessed Pendent or Standard Pendent Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any Conventional other type of wrench may damage these sprinklers. Sidewall (Vertical, Horizontal HSW1) Glass bulb sprinklers have orange bulb protectors to minimize Recessed Pendent bulb damage during shipping, handling and installation. RE- Recessed Horizontal Sidewall HSW1 MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR ARE PROTECTION. Re- Finishes (1) `2) moval of the protectors before this time may leave the bulb vul- Standard Finishes nerable to damage. RASCO wrenches are designed to install Sprinkler Escutcheon sprinklers when covers are in place. REMOVE PROTECTORS Bronze Brass BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS Chrome Plated Chrome Plated (3) TO REMOVE THE PROTECTORS. White Polyester Coated White Painted (3) Temperature Ratings Special Application Finishes Sprinkler Sprinkler Escutcheon Classification Temperature Max. Ambient Bulb Bright Brass Bright Brass °C °F Temp. Color Black Plated Black Plated Ordinary 57 135 100°F (38°C) Orange Black Paint Black Paint Ordinary 68 155 1F(38°C) Red Off White . Off White Intermediate 79 175 150°F(66°C) Yellow Satin Chrome Satin Chrome Intermediate 93 200 150°F(66°C) Green - High (t) 141 286 225»F(107°C) Blue ( Other finishes and colors are available on special order. Consult the factory for details. (1) Not available for recessed sprinklers. ( FM Approvals is limited to bronze and brass, chrome or black Escutcheon Data • plated finishes only. FaoeofF ' (3) FP Push- on/Thread -off escutcheon. Escutcheon "A "9 ( UL and ULC listed corrosion resistance. I Model Awls Adlustrttent pin b Ceilingsor SIN numbers: R3621, R3622, R3623, R3625. • 1 y " Note: For y" orifice pendent FM approved white Max Recess (38.1mm) �,e " -' /l g " polyester coated and UL approved white polyester F1 1,2,4,8 Min Recess %" (5mm -24mm) corrosion resistant sprinklers refer to Bulletin 014. (19.1mm) 1/2" Ordering Information F2 1,2,3,4,5,7,8 Max Recess (38.1mm) Vie " - 'Ye" Min Recess ri (5mm- 17mm) Specify: (24mm) 1. Sprinkler Model FP 1,2 Max Recessed 71e" 1y " (38 . 1 m m) 2. Sprinkler Type (11mm) 3. Orifice Size Thread-off 1,2 Min Recessed '� 1 " (25.4rrim) 4. Deflector Type (24mm) No Dimensional Figure for FP 5. Temperature Rating 6. Sprinkler Finish Maintenance 7. Escutcheon Type The Models F1 FR and F1 FR Recessed Sprinklers should be inspected quarterly and the sprinkler system 8. Escutcheon Finish (where applicable) maintained in accordance with NFPA 25. Do not clean Note: When Model F1 FR Recessed sprinklers are sprinklers with soap and water, ammonia or any other ordered, the sprinklers and escutcheons are packaged cleaning fluids. Remove dust by using a soft brush or gen- separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research - Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by ReIiabk led The Reliable Automatic Sprinkler Co., Inc. ® Re (800)431-1588 Sales Offices (800)848 - 6051 Sales Fax Revision lines indicate updated or new data (914)829 -2042 Corporate Offices 'r �" www.reliablesprinkler.com Internet Address Eo. Printed in U.S.A. 3107 P/N9999970027 t^ � - c�Z�7 —cr / /Z Bulleti 121 Rev.l co INN R c Model G4 Concealed Fri Automatic Sprinkler .l N • 33 co The Concealer :{ �;' ,, i A Concealed Sprinkler With /" (13mm) or 1Y2" (38mm) Adjustment -,, .., ! .6. - 4 . b Features _ -► . . 1. Push- on/Thread -off cover plate assembly � s-; . A'' - - r. , attachment with '/z' (13mm) adjustment. - . i . Does not require clips or springs. x' 2. 1 (38mm) Total adjustment provided by - ' adjustable inlet versions. . . 3. Adjustable inlet version available with either _ .__ -- - = — - -. - 1" NPT ale or female threads eliminating , -- costly reducing coupling. - . 4. Smooth aesthetic ceiling profile. a. J 5. Available in white or other color painted or brass, chrome, or black plated finishes. The Concealer is designed for use where aesthetic ap- pearance is important. Offices, hospitals, motels and res- 6. Ordinary and intermediate temperature taurants are but a few of the applications where it can be ratings. used. It is available in different orifice sizes allowing the de- signer to optimize system performance, thereby achieving a 7. Multiple orifices for design flexibility. most efficient installation. The Concealer can eliminate the need for precise cutting of drop nipples. The Push - on/Thread -off cover plate assem- I bly can be adjusted without tools so it mates accurately with Approvals & Listings the ceiling. The fire protection system need not be shut 1. Underwriters Laboratories Inc. (UL) down to adjust or remove the cover plate assembly. 2. Underwriters Laboratories of Canada. (ULC) Product Description 3. N.Y.C. BS &A No. 587- 75 -SA. The Reliable Model G4 Concealer uses the proven - Note: Approvals are for light and ordinary hazard, except for Model G fusible element in a standard style sprinkler frame small orifice sprinklers which are limited to light hazard with a drop -down deflector. This assembly is recessed into occupancies. The cup and skirt are fabricated from plated the ceiling and concealed by a flat cover plate. The steel and are intended for interior non corrosive applications. Push- on/Thread -off cover plate and sprinkler cup assem- blies are held tight by a flexible tooth engagement to the U.S. Patent No. 4,880,063. threaded cup. This threaded engagement provides 1/2" (13mm) of cover adjustment. The flat cover plate is attached Application to the skirt using an ordinary temperature classification sol- The Reliable Model G4 der. This results in a strong cover plate assembly with an or- _ Concealer is the most versatile - ::f dinary temperature rating, and an intermediate temperature concealed sprinkler available. It ., s sprinkler which can be installed in 150 °F (66 °C) environ- ments. When the ceiling temperature rises, the solder hold - provides the best form of fire pro- ing the cover plate to the skirt melts, the flat cover plate tection while offering an attractive _- 'h >> released thus exposing the sprinkler inside to the rising am- appearance and " (13mm) of `° ` bient temperature. cover adjustment for ease of instal - The subsequent fusing of the sprinkler element opens the _ r s . The adjustable 1" NPT inlet waterway and causes the deflector to drop into position to versions have 1 i s (38mm) of total distribute the discharging water. Any secure engagement of adjustment and al eliminates the need for a reducing cou- the threads between the cover plate and cup will assure that piing. The small diameter Push- on/Thread -off cover plate the drop -down deflector is properly located below the ceil- assembly is easily attached and blends into the ceiling, con- ing when a sprinkler operates. cealing the most dependable fire protection available, an automatic sprinkler system. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 . Installation hex flats. After the ceiling has been installed with holes for the Do not install The Concealer in ceilings which have positive sprinkler, each telescoping inlet section is to be adjusted with the pressure in the space in the space above. G4 Wrench. Install the push -on /thread-off cover plate assembly After a 2 inch diameter hole is cut in the ceiling, the sprinkler over the sprinkler by holding and pressing it straight up into the is to be installed with the Model G4 Wrench. The wrench has cup. Final adjustment of each cover assembly is made by hand . drive tangs which insert into cup slots. When installing a sprin- turning it clockwise until it is tight against the ceiling. kler the wrench is first positioned into the sprinkler /cup assembly Maintenance until the wrench tangs engage drive slots in the top of the cup The Model G4 Concealer should be inspected quarterly and (there are two sets of mating drive slots in the cup). The sprinkler the sprinkler system maintained in accordance with NFPA 25. is then tightened into the pipe fitting. When inserting or removing Do not clean sprinklers with soap and water, ammonia or any the wrench from the sprinkler /cup assembly care should be other cleaning fluids. Remove any sprinkler that has been taken to prevent damage to the sprinkler. DO NOT WRENCH painted applied) damaged in an ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. P (other than factory ry pp Iled ) or dama g any way. A y The adjustable inlet versions are similar to the standard Model stock of spare sprinklers should be maintained to allow quick re- G4 except that an addition 1" (25mm) of adjustment is provided placement of damaged or operated sprinklers. Prior to installs- by means of a telescoping inlet section that threads in or out of a lion, sprinklers should be maintained in the original cartons and stationary coupling reducer (either 1 male or 1 female) as shown packaging to minimize the potential for damage to sprinklers that I in Fig. 2 or Fig. 3. These sprinklers must be installed before the would cause improper operation or non -operation. ceiling is in place, by wrenching on only the coupling reducer Ordering Information Cover Plate Finishes (1) • 1. Sprinkler Model Standard Finishes Temperature Ratings 2. Temperature Rating Bronze 3. Nominal Orifice Chrome Plated - Classification Sprinkler Cover Plate Max. Ambient 4. Rat Cover Plate Finish White P Temp. 5. Inlet Type Note: Unless otherwise Special Application Ordinary 135 °F /57 °C 135 °F /57 °C 100 °F /38 °C Finishes specified, the 165 °F (74 °C) Ordinary 165 °F /74 °C 135°F/57°C 100 °F /38 °C . sprinkler will be provided with Black Plated Ordinary 165°F/74°C 165°F/74°C 100°F/38°C the 165 °F (74 °C) cover. Bright Brass Intermediate 212 °F /100 °C 165 °F /74 °C 150 °F /66 °C Off White Installation Data Black Paint Nominal Sprinkler ro Other colors and finishes are Sprinkler Total Nominal K Factor Identification available. Consult factory for Inlet Adjustment Orifice Thread Approvals Number details US Metric (SINI - Non Adjustable y " (13mm) y "(15rrm) 5.6 80 / NPT (R1) 1,2,3 R2115 Note: Paint or any other Non - Adjustable y " (13mm) 'A"(11rrm) 42 60 y " NPT (R /z) 1,2,3 R2113 coatings applied over the Nan - Adjustable y "(13mm) N (10mrn) 2.8 40 y " NPT (R1) 1,2,3 R2111 factory finish will void all Adjustable 1y "(38mm) Y " ( 1 5rrrn) 5.6 80 1 "NPT Male or Female 1,2,3 R2118 approvals and warranties. Adjustable 1y "(38mm) %"(11mm) 42 60 1 "NPT Male or Female 1,2,3 R2113 Installation Wrench Adjustable 1}S" y " (38mm) 7 "(1C rm) 2.8 40 1" NPT Male or Female 1,2,3 R2112 Model G4 Sprinkler Wrench Irj,__ f-1 f , , v ,^ i I - -yrf ' - -- Tl l - qll I ,� I fiiL Li " --- IIij* -- ' ri r �-� .. w. mnwc MRCP II , is • Zla -ice ia_' _ f 21' .ssns. as I . • , n w. • we lz' 111 ruts...,r r wr QUO � '.r 1 i m a woaar ' j �.o".Yom°r 14411 a. ° i i _. „,_,..,..... P: 1 , o .l I IRO? i i I1 i i i i i : : :. , I►„ �.1 ___________ mw 1 vwras ... ` Zi WO= mRaa Fig. 1 - y" (R /)NPT Non- Adjustable Inlet Fig. 2 - 1" NPT Male - Adjustable Inlet Fig. 3 - 1" NPT Female - Adjustable Inlet The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory • Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by • The Reliable Automatic Sprinkler Co., Inc. ReI (800) 841 -058 Sales Office (800) 848-6051 Sales Fax (914) 668 -3470 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 06/02 P/N 9999970014