Loading...
Plans / 1 4E( R 607 - cxx)54 y LILE DIAGRAM OF VAV CONNECTIONS 8060 SW Pfaffle St. Tigard, OR Ii [I 1 0 0 1 o 0 D cc 0 0 I— v, z o 0 M 0 0 I 0 STEEL GIRDERS o I Li VIEW LOOKING UP LJ bolt 1 " washer III 1 ° washer 3/8' bolt (tYp) STEEL GIRDERS 0 cc = I— II Q 4 Allthread rods per unit co m VAV UNIT 14 Irli 1 °washer sheet metal bracket 3/8° boh w/ sheet metal screws Into VAV and unistrut (typ) (VP? ge 200 -v- oy 1 Alrefco 11 August 10, 2007 Tag Data - Variable Air Volume Single Duct Terminal Units (Oty: 5) Item Tag(s) Oty Description Model Number Al VAV -1 4 Variable Air Volume Single Duct Terminal VCEF08 A2 VAV -2 1 Variable Air Volume Single Duct Terminal VCEF08 Product Data - Variable Air Volume Single Duct Terminal Units All Units Single duct with electric heat 8" inlet size Matte faced insulation - 1/2" (13 mm) r DDC, controls on /off electric heat control _ EV Standard actuator Left hand 1 24 volt transformer �IJ`� 1 � 2� Disconnect switch ‘-);-‘ Power Fuse Cir ° 1 / i S \O 277 volt, 1 phase „ C 0 Magnetic contactors - 24 volt I,� DDC space sensor with occp and set pt (FId) DDC auxiliary duct temperature sensor (FId) 1st year parts and labor warranty • Item: Al Qty: 4 Tag(s): VAV -1 Electric heater kW - 2.0 Stage -1 Item: A2 Oty: .1 Tag(s): VAV -2 Electric heater kW - 5.0 Stages - 2 -equal Performance Data - Variable Air Volume Single Duct Terminal Units Tags VAV -1 VAV -2 Design cooling airflow (cfm) 710 900 Min cooling airflow (cfm) 213 300 Valve heating airflow (cfm) 213 380 Cooling inlet diameter 8" 8" • Cooling inlet velocity (ft/min) 2034 2578 APD @ cooling airflow (in 0.07 • 0.11 H2O) Full load amps (A) 7.22 18.05 Min. circuit ampacity (A) 9.03 22.56 Max fuse size.(A) 15.00 25.00 Operating weight (lb) 38.0 38.0 Coil heating capacity-(MBh) 6.83 17.08 Room heat loss (MBh) 3.36 10.89 Room heating setpoint (F) 70.00 70.00 Primary EDB (F) 55.00 55.00 Unit LAT (F) 84.55 96.41 Electric heat kW (kW) 2.00 5.00 '.FL'D = Furnished by Trane / Instelledby Others Trane Equipment Submittal Page 3 of 12 • * Alretco TI ► August 10, 2007 Unit'Dimensions - Variable AID Volume Single Duct Terminal Units Item: Al, A2 Qty: 5 Tag(s): VAV -1, VAV -2 2 1/4' 3' —w 4-5 12'—D CONTROL BOX\ 1 4 ' AIR VALVE ELECTRIC HEATER 5 /r CONTROLS AREA AC AToR� _ AIR ® FLOW / I 43 ,' ., 2 28 Customer Notes 1. Alr Inlet is centered M unit front panel. 2. Slip 8 Drive discharge outlet on heater standard. • 3. Allow 48' of straight dud downstream of unit before first runout 8 Inside of the 12• —D duct should be equal discharge size. (AxB) SUP '8 DRIVE TOP VIEW 1212' CONNECTION 4. For elecMcheater access, side hinged door,must have minimum distance per NEC or local Code. 5. Knockouts for per supply provided In top 8 bottom of terminal box. 8. Coils are provlded.without internal insulation. tf the unit Is to be installed In a location with high humidity, external Insulation t t • around the heating Doll should be Installed as required. • 81// 4' gg 10' 11 12' — Approximate Dry Weight 3e.0 lb Weights reflected may vary BACK VIEW ±5.0 lb based upon options selected. FLD = F imished'byTrane /Installed by Others Trans Equipment Submittal Page 7 of 12 / 1 4 € _ 6 1 . < 9 0 7 - cfoso9 13SECSR 1)te ARI* capacity ratings $� N ARI CAPACITIES HIGH WALL APPLICATIONS INDOOR OUTDOOR STD. CFM NET COOLING TOTAL SEER EER HIGH HEAT SECTION SECTION Indoor Outdoor BTUH kW BTUH COP HSPF * 40BNB0183 38BNB018-3 726 1,100 18,600 1.90 10.0 9.6 N/A N/A N/A 40BNB024-3 38BNB0243 726 2,400 22,600 2.40 10.5 9.5 N/A N/A N/A 40BNB030 -3 38BNB0303 700 2,300 28,000 3.10 10.0 9.1 N/A N/A N/A 40BNB03S -3 38BNB0383 970 2,300 33,000 3.80 10.0 8.8 N/A N/A N/A 408NE0183 38BNE018-3 726 1,100 18,600 1.90 10.0 9.6 18,600 2.90 6.80 40BNE024-3 38BNE024-3 ' 726 2,400 22,600 2.40 10.5 9.5 22,800 2.80 7.00 40BNE030 -3 38BNE030-3 ' 700 2,300 28,000 3.10 10.0 9.1 28,000 2.80 7.00 40BNE036-3 388NE0363 970 2,300 33,000 3.80 10.0 8.8 33,400 2.00 6.80 LEGEND COP - Coefficient of Performance db - Dry Bulb EER - Energy Efficiency Ratio -cr HSPF - Heating Seasonal Performance Factor "' \I SEER - Seasonal Energy Efficiency Ratio wb - Wet Bulb 'Air Conditioning & Refrigeration Institute. 2OU 1 NOTES: AUG U 1. Ratings are net values reflecting the effects of circulating fan heat. Ratings are based . on:�f ' V `I Cooling Standard: 80 deg F db, 67 deg F wb air entering evaporator and 95 deg F db air e r o se k' 1 x,.-11 High Temperature Heating Standard: 70 deg F db air entenng evaporator and 47 deg F db, 4804 •_ •. epser. Low Temperature Heating Standard: 70 deg F db air entering evaporator and 17 deg F db, 6i cord rfsel.f �^ , 2. Total kW is for total system, including compressor and outdoor and indoor fan motors. : �3 ,:< 3. Ratings are based on 25 It of Interconnecting refrigerant lines. 4. All system ratings are based on fan coil units operating at high fan speed. Consult Physical Data tables for airflows at all available fan speeds. Sound ratings UNIT SOUND POWER (dba) SOUND PRESSURE (dba) 38BNB018-3 78.0 51.0 38BNB024 -3 78.0 53.0 38BNB030-3 64.0 53.0 38BNB036 -3 78.0 53.0 38BNE018-3 78.0 51.0 38BNE024-3 78.0 53.0 38BNE030-3 64.0 53.0 38BNE0363 78.0 53.0 40BNB0183 58.0 47.0 406NB0243 58.0 47.0 40BNB0303 58.0 48.0 40BNB036 -3 65.0 48.0 40BNE0183 58.0 47.0 40BNE024 -3 • 58.0 47.0 40BNE0303 58.0 48.0 40BNE036-3 _ 65.0 48.0 5 ' Physical data INDOOR HIGH WAIL UNITS 4 1 COOUNG AND HEAT PUMP MODELS UNIT 40BNB018 40BNB024 40BNB030 40BNB036 40BNE018 40BNE024 40BNE030 40BNE036 NOMINAL CAPACITY (Tons) 1.5 2.0 2.5 3.0 1.6 2.0 2.5 3.0 • OPERATING WEIGHT (lb) 27.5 27.5 44.0 83.0 27.5 27.5 44.0 83.0 MOISTURE REMOVAL (ptslhr) 5 7 8 8 5 7 8 8 REFRIGERANT TYPE R -22 R -22 R -22 R -22 R -22 R -22 R -22 R -22 METERING DEVICE Capillary Capillary Capillary Capillary Capillary Capillary Capillary Capillary CHARGE (Ib) NOTE 1 3.1 3.8 4.7 8.0 3.1 3.8 4.7 8.0 INDOOR FAN (Direct Drive) High — CFM 726 726 860 950 726 726 860 950 Med — CFM 565 565 730 770 565 565 730 770 Low — CFM 484 484 580 620 484 484 580 620 Motor Horsepower 1 /10 1 /e 1 /e 1 /6 1 /10 1/0 I/O 1/0 REFRIGERANT LINES Connection Ty Flare Flare Flare Flare Flare Flare Flare Flare Liquid Line (In.) e 1 /4 od 3 /e od 3 /e od 3 /e od 1 /4 od 3 /e od 3 /e od 3 /e od Vapor Line (in.) 1 /2 od 6 /e od 5 /e od 3 /4 od 1 /2 od 6 /e od shod 3 /4 od Max Length, Lift & Drop (ft) 130/66/66 130/66/66 130/66/66 130/66/66 130/66166 130/66/66 130/66/66 130/66/66 CONDENSATE DRAIN Outside Dia (In.) 5 /e Dia 5 /a Dia 5 /a Dia 5 /e Dia 5 /a Dia 5 /6 Dia 5 /e Dia 5 /e Dia CONTROLS (Microprocessor) Remote (Wireless UR) Yes Yes Yes Yes Yes Yes Yes Yes Freeze Protection Yes Yes Yes Yes Yes Yes Yes Yes Defrost Method WA N/A N/A N/A Demand Demand Demand Demand Warm Start N/A N/A N/A N/A Yes Yes Yes Yes Auto Changeover N/A N/A N/A N/A Yes Yes Yes Yes Auto Restart Yes Yes Yes Yes Yes Yes Yes Yes Diagnostics Yes Yes Yes Yes Yes Yes Yes Yes Timer Mode (Start/Stop) 24 Hr 24 Hr 24 Hr 24 Hr 24 Hr 24 Hr 24 Hr 24 Hr Test Mode Yes Yes Yes Yes Yes Yes Yes Yes Dehumidification Mode Yes Yes Yes Yes Yes Yes Yes Yes Fan Speeds H/M/UAuto H /M/UAuto H/M/UAuto H/M/UAuto H/M/UAuto H/M/UAuto H/M/UAuto H/M/IJAuto Control Voltage 24v 24v 24v 24v 24v 24v 24v 24v System Voltage 208/230v 208/230v 208/230v 208/230v 208/230v 208/230v 208/230v 208/230v AIR SWEEP Horizontal Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Vertical Manual Manual Manual Manual Manual Manual Manual Manual FINISH White - White White White White White White White NOTES: 1. Units are shipped with a full factory charge in the outdoor unit based on 25 ft of refrigerant lines. 2. See Application Data section for long line lengths. 3. See matching outdoor unit for line lengths. 4. Capillary in outdoor unit. 6 • OUTDOOR UNITS , V ( / , COOLING ONLY MODELS UNIT 38BNB018 38BNB024 38BNB030 38BNB038 38BNE018 38BNE024 38BNE030 38BNE036 NOMINAL CAPACITY (Tons) 1,5__. 2.0 2.5 3.0 1.5 2.0 2.50 3.0 OPERATING WEIGHT (lb) C143 187 198 198 143 187 198 198 REFRIGERANT TYPE R -22 R -22 R -22 R -22 R -22 R -22 R -22 R -22 METERING DEVICE Cap Tube Cap Tube Cap Tube Cap Tube Cap Tube Cap Tube Cap Tube Cap Tube CHARGE (lb) 3.1 3.8 4.7 8.0 3.1 3.8 4.7 8.0 OUTDOOR FAN CFM High/Low 1,000/830 2,400/2,050 2,750/1,830 2,455/1,660 1,000/830 2,400/2,050 2,750/1,830 2,455/1,660 Horsepower 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 REFRIGERANT UNES Connection Type Flare Flare Flare Flare Flare Flare Flare Flare Liquid Line (In.) 1 /4 od 3 /8 od We od We od '/4 od We od 3 /8 od We od Vapor Une (n. 1 /2 od 5 /e od 5 /e od 3 /4 od 1 /2 od 5 /8 od 5 /e od 3 /4 od Max Length (ft) 130 130 1 130 130 130 130 130 t Max U 66 66 66 66 66 66 66 66 Max Drop (ft) 66 66 66 66 66 66 66 66 COMPRESSOR Manufacturer Bristol Copeland Copeland Copeland Bristol Copeland Co eland Copeland Model H25B18QABC ZR24K3 ZR30K3 ZR36K3 H29B18UABC ZR24K3 ZR30K3 ZR36K3 Type Recip Scroll Scroll Scroll Recip Scroll Scroll Scroll OIl Charge (oz) 35.0 38.0 42.0 42.0 35.0 38.0 42.0 42.0 Heater Yes No No No Yes No No No Accumulator Yes Yes Yes Yes Yes Yes Yes Yes CONTROLS Control Voltage 24 v 24 v 24 v 24 v 24 v 24 v 24 v 24 v System Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Defrost Method N/A N/A N/A N/A Demand Demand Demand Demand FINISH Off White Off White Off White Off White Off White Off White Oft White Off White NOTES: 1. Available in 208/230v, single -phase only. 2. Unit shipped with full factory charge. 7 - . • • 00 • ` UNIT r A B C 0 E F WEIGHT j+' 4o�1018' - 21 / II 1/8 11 (i2 7] te 8] 27. 5' KB] \ \\\\\\ ������\\\\\\\ \ \ \ \ \ \ \\\ \ \ \ \ \ \ \\\\ \ \ \ \ \ \��� \ \� � \, \ y - 42 178 11 T/8 7 1/2 35 1/4 5/8 3/8 27.5 LB 3 15/16 [100] MIN ' 4004024 . [1070] [290] [190] [895] [15.8] C9.53 [12.5 Kg] 1 — - ■� :NOTES. - - - - 1. DIME)61016 IN INCHES, [ ]ARE IN MILLIIETF1t5 - DO NOT SCALE, I in C12] 2. DIRECTION OF AIR FLOW. \ \ I i 3. REFRIGERANT, DRAIN AND.POWER.CONNECTIONS MAY BE MADE REAR (LEFT OR RIGHT), � J -- I! .1.-,t.._ - . LEFT SIDE, RIGHT SIDE, OR BOTTOM LEFT. REFRIGERANT ACCESS HOLE MAY BE \ \ \ �f • POSITIONED ANYWHERE ALONG BOTTOM EDGE AT !EIGHT SHOWN (FOR REAR CONNECTICW . 4. ING BRACKET PROVIDES CO .875 DIA. HOLES TO ALLOW 1/2" CONWIT \ 3 1S/16 (1001 MIN. 11 13/16 \ Q. 1300) MIN. \ Immo 'TOP VIEWI MINIMUM CLEARANCE FOR SERVICE AND AIR FLOW WALL SLEEVE 00000 00000 3.0 RI DIA C76] FOR REFGERANT. DRA POWER AND SIGNAL LINES / 3 � INLET AIR r/ 1 IR FILTERS KNOCKOUT FOR RIGHT SIDE �I� (OPEN COVER FOR ACCESS) ' R I G H T SIDE VIEWI REFRIGERANT DRAIN, POWER FRONT VIEWI AND SIGNAL LINES I _ EVAPORATOR COIL DRAIN 0.625 (15.81 OD % T I FLEX STIC) y MALE BARB CONNECTION G'LASTIC) memo AIR SUCTION L] E CONNECTION 3 1 - I E MALE FLARE 1n y1` I I • LIQUID L) I CONNECTION EF TI I 11 - DRAIN TRAY O iii u`y X660] O 25 ' o o ' 'liii .. . mat =OM COOLING A-. 0 i AUTO AIRSWEEP LOUVER UNIT OUTLI` '1 I" ,,* - "A" INFRARED REMOTE SENSOR — "C" } HEATING KNOCKOUT FOR LEFT SIDE INDOOR FAN MOTOR 'p' 3 REFRIGERANT DRAIN. POWER _ _(78] y AND SIGNAL LINES i - - ILEFT SIDE VIEWI _ o 0 O IT T -I r T t r 1 _ 1 D O I 1 1 0 o ' / CONNECTION ' ' 1 ; ' I I ' ; I- I I ' I ( 1 1 I CS, O 1 1 , 1 /2 �� 1 I J �__L ` 138, _ � 11 I r ?• 111111111 1 1 l • ::; • :. : BLOWER EL ' _ _ _ _ _ _ _. INDOR AIR - - - CO 15 3/8 I BOTTOM V 1 EW I KNOCKOUT FOR BOTTOM cn (381] O REFRIGERANT DRAIN POWER ANb SIGNAL LINES MOUNTING 3 . 0 DIA BRACKET !MOUNTING BRACKET DETAIL! [72] (NOTE .3) ,v