Plans r /45795- 6'033 3 /690 1/ ✓ ' Special Conditions /Provisions: 1. All work shall conform to City of Tigard, Oregon, Standards and Specifications. Note the attached Drawings and Details. 2. Notify City Inspector Letha Thomas ( #639 -4171) 24 hours before starting any work. 3. Access -to and egress -from parcels of land adjacent to the work area shall be maintained at all times. Pedestrian safety shall be provided for by the contractor at all times. 4. Removal /replacement work and damage repair work shall be promptly initiated and P completed to the City's satisfaction. No work shall be considered complete until it is accepted by the City. The City reserves the right to cause testing and certification of work or repairs to be performed, to the City's satisfaction, at permittee's expense. 5. Erosion control shall be provided for by the contractor. p 6. ORS 757.541 -571 applies (pre- notification for location of underground facilities, etc.). 7. It is the sole responsibility of the permit holder to provide for proper right -of -entry (and /or easements) prior to starting work. Proof of right - of - entry (and /or properly executed easements) shall be provided to the City. The City shall in no way be construed to be liable for the permit holders failure to obtain or provide for proof of right -of -entry (or easements). 8. 1 9. A sewer connection permit is required to be obtained from the City's Building Division prior to connecting to the City's sewer system. 10. Utility relocations, modifications or repairs, which may be necessary, shall be performed in a timely manner at the permittee's expense. 1 dj/spec- con.sop S I O -� . G ,. `' I 103952 � 0a10 123 D0 Ia - o , 0 �') — -- _ma=r- . �.: >-. s / S. W. .. o� d \ o 4..,43 12330 0 0 43 F S L' <" *e; �O J ST s a ,, �° �/ / 3 4 0 ° �° �' O 'y � O ' y 23 1 0 O O 12390 0 � 0 0 9 , \ p `L � o C) 1 4 12 0 0 °- ° p `1. O � Ss/O F /24 `24 ' ° ° O - 0 . , O \ ■ ., 10 ' I �L ° m I N \ p � 1 2430. o rn sZs O r, �h ■∎ ° ' /, o 12 a I , �t, /2q o 0 �p2 -p \° , Q 60 ° /2C 12500 O o / . 12505 / 24 90 — _ \0 0 O N O � ,� / > / ?s F�,� aoK S\ — h � , s ��` I /2 / \ p� 2S s /? 2$00 / c' SS I /e, ,5',. O / S /2 �• S / ,5-_, 2 S SS L ° , S'9 C /2 O �o I /2,5s, ? F' / 6'3 4,Q. '�K., 0 i \\-\. \ oi) /2. / an' ti co /? 12 300 / -� P �, Z , / 2$ , �,� o \p Q u s /2 / S T � /2 s s o a s s , `° � , ,h s g f t' , 9' 12b3 / / �° h ° �O � /,` V . ,�`O 2 �s 266 0' °� � � \ p a y / c / *� \ /? \ `L 2 6 9s / ? ° O \ per \�� yP s 12 700 X 3 3' , / ? T �� ° / s o w" �-;L /� /� ,sS 30 I ° O `� j 6 ' ' , <</ / 2? 19 ,ti0 oft 12 300 �' / ?� � I , /` 's s /2 s o �� • y 2 , O O > ( ' /2 / ? ? O ' re /r35, "S ��� 62 0 26 3 ?O � o � ° 9 -aP /2 /,"..9 � � O� a 6 4 4 �'a of O I O "O / ' ti /29 ( / t► 12 900 � fi g% D I S T. 23J , /2A 3 0 I V I / 2 u' „,..,:s. ( / /`�O / %. 13000 o a °`' �`� a ,r n O 3 ° S I. O Z ' � �� � ; 'l � ,.? S OS F MS j %19/,,\ / 3 0 0,70 I S _%• < .-r a r� /3 b SKETCH: c A Rc r L _3 : ‘1.1°P. r I I I ; 1ZocS � S,uJ. uJNCK 1C ISfl M 14 sr t ------ I 4,1 r` \" Li a I r I _Z FARcr I_ 2 tJ ;( J 7 1 ■ f, 1 l 'i 1 _ c. .1.. .AL- . I S\N wAl1<1'Ns 4 vc , . N ,,,,h) MEW BUILDING SEWER PIPE, SIZE AS SPECIFIED I' Ii aI ., . - 1 i PLANT FABRICATED TEE FITTING ON SEWERS 18" AND SMALLER. BACKFILL 2X4 FIELD TAP ON EXISTING SEWERS AGAINST PLUG TO AND NEW SEWERS LARGER THAN THAN 18„ 1 s PREVENT PLUG I BLOWOEF & SECURE 2X4 IN PLACE WITH — TRENCH BACKFILL. SEWER M PLAN I -OR LATERAL 1 .1 EXTEND AT LEAST GROUND 12" ABOVE SURFAC ` SURFACE MINIMUM SLOPE FOR . 6" PIPE : 0.010, FOR 0', 4" PIPE = 0.020. -.a- • CONNECTION MARKER : MAGNETIC TAPE —S s GREEN ./BLACK LETTERS (WASTEWATER) GRE EN w /BLACK LETTERS (STORM DRAIN) `— 0 PLUG it. . wood I 11011111111 3/4 -O PIPE ZONE MATERIAL t'P L• .... SUPPORT TEE WITH AS SPECIFIED .ss��l'- vo, . BEDC4 N G GRAVEL, MNNIMUM 2' 0" WIDE S I DE BUILDING SEWER . Yin 4 Unified s. of Want t«,� DWg. No. 300 Co il 0 PVC SADDLE (TEE) I I � STRAP RETAINER RIDGES I i ' EN - 1 RUBBER GASKET L \\ �_ J l-�_ / -+ SEWER PIPE- \ ST ' N = STEEL STRAP ,.. A .:�__SS S __� x PVC SADDLE SHALL BE ASTM 3034 SDR 35 I PVC COMPOUNDS SHALL BE ASTM D1784 WITH CELL CLASS OF 12454 -B /C OR 12364 -C II ALL ELASTOMERIC SEALS (RUBBER GASKETS) SHALL BE ASTM F477 I STAINLESS STEEL BANS SHALL BE 300 SERIES, FULL 9/16" WIDTH BAND, 5/16' SHOULDERED HEX HEAD, SLOTTED SCREW AND IS CADIUM PLATED, CARBON STEEL. * INSERTION HOLE SHALL BE CORE DRILLED. PVC GASKETED t ' .1 ' , " f . ••,,".7.411.°1 t gewerag nmed e SADDLE ..ter agenCY DRAWING N0. 350 F A , I. COMPLETE RUBBER SLEEVE 1;MH3) AS CMSEGMENT OLDS � j� LT IN PLACE. • 2. STAINLESS STEEL BAND (9/16" SERIES 300) 1 ��i8 SECURES UPPER HALF OF RUBBER SLEEVE TC THE PVC HUB. • 3. PVC HUB (ASTM 3034 SDR 35) DRIVE INTO CENTER OF RUBBER SLEEVE AFTER SLEEVE IS PLACED IN HOLE. 3 ............... 1 •i�ii i1T :, c 2 V /f r z %: i&r# • CONCRETE PIPE ' ' ' ', • NOTE: ALL INSERTA —TEE HOLES SHALL BE MACHINE DRILLED. \ ,Nt:Z= unified INSERTTEE y r , -. DRAWING NO 360 MIN. 3" A.C. IN 2 Lk I S STREET AREAS I OUT OF STREE i AREAS SAW CUT I 6 EXISTING SECTI• � II: 11 - 11 - �%% RESURFACING =11=11=1 _ 1 :; / / 11::11= • •••• • •. ••..-.--.• • - 11-11. . 1 ° 0 o ° ° ° ° ° o 0 0 0 ° • / /II 0000 000 000 O ° O O / / 0 o° o // ° ° / / 0 0 0 / ° CLASS e ° > 4 / J1 4[ L BACKFILL ° f- CLASS A 11 =11= BACKAIJ 2" - 0" 0 o ° o _ 11. o O 0 ° 0 • ° 00 / //j d 0 0 0 0 // w 0 3/4" - 0 "1 ° 0 0 0 / w C GRANULAR BACKFILL ° ° ° o ° o o / /// L I11:! :I1. : Q /// 11 ° a o ° ° ° /// V II: 1 :11:= ° o o ° o / / IL =II: ° , -11= -IIn 0 to a 0 s ▪ • • = :11 -11: • • • • . 1111 a :r • • • • • . • • PIPE BASE BACKFILL IN STREET AREAS 1. IF S/W IS AGAINST CURB, ALL ROCK TO BACK OF S/W. 2. IF S/W IS NOT AGAINST CURB, FILL ROCK 2' BACK FROM CURB. PIPE BEDDING AND BACKFILL DETAILS REFERENCE APPROVED BY DRAWN BY CITY OF Tl GARD 14-406 (MOO.) CAB OREGON SCALE DATE DWG. FILE N. T.S 7 - .t DETARS\P1P ®ID.DWC • GENERAL NOTES 1. TRAFFIC SIGNS TO BE 48" X 48" MEAD Tp " p BLACK ON ORANGE. 1O0' 2. NO COLLECTOR STREET LANE CLOSURES MIN. OR LOCAL STREET CLOSURES DURING I THE FOLLOWING TIME PERIODS: arc Loc --i- O "2` 7:30 - 8 :30 A.M. 100' I 4:30 - 5:30 P.M. MIN. a„oan AHEAD O 3. THE CITY'S STANDARD SPECIFICATION -' '20-'A FOR TRAFFIC CONTROL IS "MANUAL 100' ON UNIFORM TRAFFIC CONTROL MIN. DEVICES FOR STREETS AND HIGHWAYS', U.S. DEPT. OF TRANSPORTATION, 1 I FLAGGER I FHUA, 1988 EDITION. g 100' 4. ACTUAL SIGN PLACEMENT TO BE o MIN. I • • 50' MIN. ADJUSTED IN FIELD. DO NOT REDUCE z ■ BELOW MINIMUMS WITHOUT CITY 12' ■- • -1 APPROVAL. MIN. I ■ J 5. THE CITY RESERVES THE RIGHT TO ADD TO ■ 1 < OR MODIFY TRAFFIC CONTROL REQUIREMENTS I '■ MIN N AS MAY BE NECESSARY TO EH LCT1VELY CONTROL TRAFFIC AND TO ENSURE PUBLIC I FLAGGER I o CZ SAFETY. ( < 6. NO LANE CLOSURES WITHIN 200 FEET OF 100 I A TRAFFIC SIGNAL WITHOUT PRIOR CITY MIN. o APPROVAL p M i3 �7A 100' MIN. LEGEND O cow LAME � 120-4 O TRAFFIC SIGN 100' MIN. ® CONSTRUCTION ZONE ( O 1 o TRAFFIC CONES OR APPROPRIATE DELINEATION DEVICE. A TRAFFIC CONTROL .u.1 TYPICAL DETAIL REFERENCE I APPROVED BY 1 DRAWN BY CITY OF TIGARD CAA OREGON � DATE DWG FOE N.T.S. 7 -9 -93 ,k DET/TRAFCONT.DWG