Permit CITY OF T MECHANICAL
Anta. ��� DEVELOPMENT SERVICES PERMIT
- . !+L ° = 1 13125 SW Hall Blvd., Tigard, OR 97223 (503) 6394171 PERMIT # • MEC98 - 0545
DATE ISSUED: 12/22/98
PARCEL: 2S102CB- 01805
SITE ADDRESS...: 10400 SW PARK ST
SUBDIVISION - ZONING: R -3.5
BLOCK ° LOT • JURISDICTION: TIG
CLASS OF WORK..:NEW FLOOR FURN • 0 EVAP COOLERS: 0
TYPE OF USE -COM UNIT HEATERS..: 0 VENT FANS...: 0
OCCUPANCY GRP..:E3 VENTS W/0 APPL: 0 VENT SYSTEMS: 0
STORIES • 1 BOILERS /COMPRESSORS HOODS • 0
FUEL TYPES 0 -3 HP • 3 DOMES. INCIN: 0
:GAS 3 -15 HP ° 0 COMML. INCIN: 0
MAX INPUT: 0 BTU 15 -30 HP : 0 REPAIR UNITS: 0
FIRE DAMPERS ?..: 30 -50 HP • 0 WOODSTOVES..: 0
GAS PRESSURE...: 50+ HP • 0 CLO DRYERS..: 0
NO. OF UNITS AIR HANDLING UNITS OTHER UNITS.: 0
FURN < 100K BTU: 0 <= 10000 cfm: 0 GAS OUTLETS.: 1
FURN > =100K BTU: 3 > 10000 cfm: 0
Remarks : Mechanical work for new children's day school facilty.
Owner: FEES
JUMBO FERNANDO type amount by date recpt
17549 OAK MEADOWS LANE PRMT $ 52.50 GEO 12/22/98 98- 311708
LAKE OSWEGO OR 97034 PLCK $ 13.13 GEO 12/22/98 98- 311708
SPCT $ 2.63 GEO 12/22/98 98- 311708
Phone #:
Contract or:
JOHN KLUNE
12370 SW DUCHILLY CT
$ 68.26 TOTAL
TIGARD OR 97224
Phone #: 639 -4359
Reg #..: 2 804
REQUIRED INSPECTIONS
This perait is issued subject to the regulations contained in the Gas Line Insp
Tigard Municipal Code, State of Ore. Specialty Codes and all other Mechanical Insp
applicable laws. All work will be done in accordance with Heating Lint Insp
approved plans. This permit will expire if work is not started Duct Inspection
within 180 days of issuance, or if work is suspended for sore S. D. Shut —down
than 180 days. ATTENTION: Oregon law requires you to follow rules Misc. Inspection
adopted by the Oregon Utility Notification Center. Those rules are Final Inspection
set forth in OAR 952 - 001-0010 through OAR 952- 001 -0080. You Nay
obtain copies of these rules or direct questions to OUNC by calling
(503)246 -9187.
Issue B ,4,-,,,,, Permittee Si nature: Ilir . ,-
++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++
Call 639 -4175 by 7:00 p.m. for inspections needed the next business day
++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++
S/ c- 1-s lt? C
Plan Check #
CITY OF TIGARD Mechanical Permit Application Recd By - _
13125 SW HALL BLVD. Commercial and Residential Date Recd
TIGARD, OR 97223 p4,0iti Date to P.E. / - 3 1g
(503) 639 -4171, x304 0i,% V\ Date to DST I - f /g14(W
Print or Type if Permit # 14£698 -D5
Incomplete or illegible applications will not be accepted
Called
Nye of Development/Project Description
/ i y h J JP / r7 l h `4. s Table 1A Mechanical Code Qty Price Amt
Job Street Address Suite# A) Permit Fee 10.00
Address /0 vol., �L4/ 4-A-14 Sr 1) Furnace to 100,000 BTU
including ducts & vents 3 6.00 � �
Bldg# City/State Zip 2) Furnace 100,000 BTU+
including ducts & vents 7.50
Name (or name of business) 3) Floor Furnace
Owner ,J ..,t a n Fa---x.--A-a--01?, including vent 6.00
Mailing Address 4) Suspended heater, wall heater
or floor mounted heater 6.00
/ 7 S L/9 al%d--dlll D 0-'5' L,✓ 5) Vent not included in appliance permit
City/State Zip !� Phone 3.00
L /2s a � ?6 -7c- CHECK ALL *Boiler Heat Air
Name (or name of business) THAT APPLY: or Pump Cond Qty Price Amt
/�
■ Comp
.;-e
C , c D P er : 6-[.. :j 6) <3HP;absorb unit to N
Occupant Mailing Address 100K BTU 3 6.00 /k
7) 3 -15 HP ;absorb unit
City /State Zip - Phone 100k to 500k BTU 11.00
8) 15 -30 HP; absorb
Contractor Name unit .5 -1 mil BTU 15.00
9) 30 -50 HP; absorb
J 7 Hri /I :...r'b unit 1 -1.75 mil BTU . 22.50
Prior to permit Mailing Address 10) >50HP; absorb unit
issuance, a copy / - 7 c' 51.,.. cii is c y C 7 i >1.75 mil BTU 37.50
of all licenses City/State Zip Phone 11) Air handling unit to 10,000 CFM
are required if / ; -J 4- 77 2 G 5 4.50
expired in COT Oregon Const. Cont. Board Lic.# Exp. Date 12) Air handling unit 10,000 CFM+
database 'Z'( P V/ 3 • ash _-;( 7.50
Architect Name 13) Non - portable evaporate cooler
�dt- Ti:" - U-, / /� Pf. Tbz!'i. vi_ e ' 4.50
M ailing Address 14) Vent fan connected to a single duct
or .r2 3.00
Z' 2-/ S/A/1/14■9 /5 / -4 '5 15) Ventilation system not included in
Engineer City/State Zip Phone appliance permit 4.50
p owi iL►+�I9 L 757/ 16) Hood served by mechanical exhaust
Describe work to be done: 4.50
17) Domestic incinerators
New % Repair 0 Replace with like kind: Yes 0 No O 7.50
Residential 0 Commercial 18) Commercial or industrial type incinerator
30.00
Additional information or description of work: 19) Repair units
4.50
20) Wood stove
4.50
21) Clothes dryer, etc.
• 4.50
Type of fuel: oil 0 natural gasfi LPG 0 electric 0 22) Other units
4.50
I hereby acknowledge that I have read this application, that the information 23) Gas piping one to four outlets
given is correct, that I am the owner or authorized agent of 2.00
the owner, that plans submitted are in compliance with Oregon State laws. 24) More than 4 -per outlet (each) / .50
Sign 2?f er /Agent 2 _ / Date - ��t
/ Minimum Permit Fee 525.00 SUBTOTAL qr i � // � 19
5% I
Contact Person Name Phone PLAN REVIEW 25% OF SUBTOTAL P� e . b�
--� Required for ALL commercial permits only b
O /.1 j et µ r' L� 6 3'y I-11 rq TOTAL
'State Contractor Boiler Certification required
"Residential A/C requires site plan showing placement of unit
I:Unechperm.doc rev 07/20/98
•
8/8/99 Activities for Case #: MEC98 -00545
3:19:11 PM
• Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MECC007 Application received . 12/1/98 JSD RECD DRA 12/3/98
MECC008 Permit created 12/3/98 DEB DONE DRA 12/3/98
MECC011 Routed to Plans Examiner 12/3/98 DEB DONE DRA 12/3/98 •
MECC014 Plan checked /Approved by P.E. 12/18/98 RDP APPR RDP 12/18/98
MECC015 Reviewed Plans Routed to DSTS 12/18/98 RDP APPR RDP 12/18/98
MECC012 Plan Review Ltr. to Ofc. Svcs. 12/3/98 12/3/98 RDP SENT RDP 12/3/98
MECC705 Gas Line Insp 12/18/98 12/31/98 RB PASS RB 12/31/98 340516 This inspection does
not include the mechanical
appliance installation. Do not
allow contact of gas line to
cooper water lines. Strap
termination of gas line in mech.
room.
MECC706 Mechanical Insp 12/18/98 2/17/99 RC PART ROC 2/17/99 BATH FANS APP.
MECC725 Heating Unt Insp 12/18/98 2/17/99 RC FAIL ROC 2/17/99 UNABLE TO INSPECT
• ' WITHOUT LADDER
MECC735 Duct Inspection 12/18/98 2/17/99 RC FAIL ROC 2/17/99 DUCT DISCONNECTED IN
ONE SPOT AND
UNINSULATED IN SEVERAL
PLACES
. MECC745 S.D. Shut -down 12/18/98 RDP 12/18/98
MECC750 Misc. Inspection 12/18/98 1/7/99 RC PASS ROC 1/8/99 Check osa requirements as
shown on plans VENT
APPROVED
MECC799 Final Inspection 12/18/98 5/6/99 RC FAIL AKJ 5/6/99 See BUP98 -00167 final
MECCO50 (F) Ready to issue 12/21/98 GEO PASS GEO 12/21/98
MECC090 (F) Issue permit 12/22/98 GEO PASS DST 12/22/98
MECC706 Mechanical Insp 2/22/99 RC FART ROC 2/22/99 SUPPORT B VENTS FOR
WEIGHT -1ST INSP. SECURE
• UNITS TO PLATFORM- 1ST
INSP. INSUL DUCTS 2ND
NOTICE
MECC755 «REINSPECTION» 2/22/99 RC 1500 ROC 2/24/99 2ND NOTICE FOR DUCT
• INSUL FEE WAS PAID 2 -22 -99
ON PERMIT BUP98 -0167
RECEIPT # 99- 312970
MECC725 Heating Unt Insp 2/25/99 RC FAIL ROC 2/25/99 NO ACCESS PROVIDED
MECC750 Misc. Inspection 3/3/99 RC FAIL ROC 3/3/99 SUPPORT B VENT 2ND
NOTICE
MECC710 Mechanical Insp 4/5/99 AKJ DONE • No Hold AKJ 4/5/99 Passed TLP
MECC799 Final Inspection 5/24/99 5/24/99 5/24/99 HAP . FAIL No Hold AKJ 5/24/99 Brace HWT Bvent back to roof
Page 1 of 2
8/8/99 Activities for Case #: MEC98 -00545
3:19:11 PM
• Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MECC799 Final Inspection 5/27/99 5/27/99 5/27/99 HAP PASS No Hold AKJ 5/27/99
MECC800 Case Fineled 5/27/99 AKJ DONE No Hold AKJ 5/27/99
•
Page2of2
CITY OF TIGARD BUILDING INSPECTION DIVISION
MST
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 C6,0 Gf
Date Requested 5 -3-1 -q q AM PM x 411110 9—y 3 fr T
Location I OL 1OO Piz Suite Qs/S
Contact Person OnV Y) Ph ? . .R / PLM
Contractor Ph SWR
= i ILD Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation F- FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab 5 i"r ?t ' tO!2 S'Z74 a44 SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
M' •
i • -
r' PART FAIL
P I MBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
KNIECHAN1 *L ?
Post & Beam 1 /U
Rough In VVV�
Gas Line
Smoke Dampers
n:•
PART FAIL
TRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk
5 Other Date ��7 Inspector • ita A E 4
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.