Permit CITY OF TIGARD DEVELOPMENT SERVICES BUILDING PERMIT PERM I T # • BUP97 -0514 13125 SW Hall Blvd., Tigard, 0R 99722 (5 6 -4 DATE ISSUED: 07 / 01 / 98 PARCEL: 2S115BA -00600 SITE ADDRESS...: 16105 SW PACIFIC HWY SUBDIVISION • ZONING:R -12 BLOCK • LOT • JURISDICTION:KIN REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION — CLASS OF WORK.:NEW FIRST • 14007 sf N:1HR S:1HR E:1HR W:1HR TYPE OF USE...:COM SECOND...: 14007 sf PROTECT OPENINGS? TYPE OF C0NST.:5 -1HR 14007 ...: 0 sf N: S: E: W: OCCUPANCY GRP.:R1 TOTAL : 28014 sf ROOF CONST: FIRE RET ?: OCCUPANCY LOAD: 255 BASEMENT.: 0 sf AREA SEP. RATED: STOR.: 0 HT: 0 ft GARAGE...: 0 sf OCCU SEP. RATED:1HR BSMT ?:N MEZZ ?:N READ SETBACKS REQUIRED FLOOR LOAD • 50 psf LEFT: 0 ft RGHT: 0 ft FIR SPKL:Y SMOK DET..:Y DWELLING UNITS: 0 FRNT: 0 ft REAR: 0 ft FIR ALRM:Y HNDICP ACC:Y BEDRMS: 0 BATHS: 0 IMP SURFACE: 0 PRO CORR:Y PARKING: 0 VALUE. $ : 2400377 Remarks : New construction of a 73 unit motel Owner: FEES KCM ASSOCIATES LLC type amount by date recpt 10895 SW FIFTH PLCK $ 3693.95 DRA 10/31/97 97- 300588 BEAVERTON OR 97005 FIRE $ 2273.20 DRA 10/31/97 97- 300588 PRMT $ 6185.50 B 03/25/98 98- 304392 Phone #: 643 -5721 5PCT $ 309.28 B 03/25/98 98- 304392 FIRE $ 201.00 B 03/25/98 98- 304392 Contractor: PLCK $ 326.63 B 03/25/98 98- 304392 SUPER ONE INC PRMT $ 229.00 DEB 07/01/98 98- 306967 10950 SW 5TH PLCK $ 148.85 DEB 07/01/98 98- 306967 STE 150 Additional fees not shown here BEAVERTON OR 97005 Phone #: 643 -5721 $ 13470.46 TOTAL Reg #..: 000571 -- REQUIRED ACTIONS or INSPECTIONS--- - This permit is issued subject to the regulations contained in the Foot /Found Insp Slab Insp Tigard Municipal Code, State of Ore. Specialty Codes and all other Foot /Found Insp Masonry Insp applicable laws. All work will be done in accordance with Foot /Found Insp Masonry Insp approved plans. This permit will expire if work is not started Foot /Found Insp Framing Insp within 180 days of issuance, or if work is suspended for more Foot/Found Insp Roof n a i l n g Insp than 180 days. ATTENTION: Oregon law requires you to follow the Foot/Found Insp Insulation Insp rules adopted by the Oregon Utility Notification Center. Those Foot /Found Insp Shear Wall Insp rules are set forth in OAR 952-001 -0010 through OAR 952- 00101987. R e i n f Steel Insp Gyp Board Insp You many obtain a copy of these rules or direct questions to OUNC Slab Insp Su s p Ce i l n g Insp by calling (503)246 -1987. Slab Insp Reinforced concr Slab I Structural mason Slab nsp Smoke detector i /� ' Permittee Signature: / a.1i...1.lI.1 e� Issued y. 1 Call 639 -4175 by 7:00 p.m. for an inspection needed the next business day +++++++++++++++++++++++++++++++++++++++++++++++ + ++ + + + + + ++ + ++ + + + + + + + + + + + + + + + + ++ C` Building Permit Application OF TIGARD Commercial Buildin Pit A licati Rec'd Bel • 13125 SW HALL BLVD. Tenant Improvement TIGARD, OR 97223 / it Date Recd '/ " Date to P.E. r a , , (503) 639 -4171 Date 1 y -P Permit it l�it.Ap 17 0 �' /�/ Print or Type Related WR# Incomplete or illegible applications will not be accepted Called — — -- Name of Development/Project Existing Building ❑ New Building ❑ Job Best Western Address Street Address Suite Building 16105 SW PAC. Hwy Data Bldg # City /State Zip Existing Use of Building or Property: King City, OR 9/22 Name Property KCM Associates L.L.C. Proposed Use of Building or Property: Owner Mailing Address Suite 10895 SW Fifth No. Of Stories: City /State Zi Phone 3eaverton, 01� 97005 643 -5421 Sq. Ft Of Project Occupant Name • Occupancy Class(es) Name Contractor Super One, Inc . Type(s) of Construction Prior to permit Mailing Address Suite issuance, a copy 10950 SW F i t h 150 Will this project have a Fire Suppression System? of all licenses Yes ❑ No, are required if City/State Zi p Phone expired in C.O.T. 3eaverton , OR 9700_3 Americans with Disabilities Act (ADA) database 643-5721 Valuation X 25% - Participation Oregon Const. Cont. Board Licit Exp. Date Complete Acces ill \ orm 57193 06/02/00 Project $ �. Name Valuation 37) 5 S Architect Plans Required: See Matrix for number of sets to submit Mailing Address Suite 2- on back City/State Zip Phone I hereby acknowledge that I have read this application, that the information given is correct, that I am the owner or authorized agent of the owner, and Engineer Name that plans submitted are in compliance with Oregon State Laws. Robert Race Signature of Owner /Agent Date Mailing Address Suite 444 W. 78th St. Contact Person Name Phone 3?uomington zi 55 4S i l ne ; 800) 747 -8971 FOR OFFICE USE ONLY Indicate type of work: New 0 Addition 0 Demolition 0 Accessory Structure 0 Foundation Only 0 Alteration 0 Map/TL# I Land Use: Repair 0 Other O Notes: Description of work: TIF: . Note: Site Work Permit Application must precede or accompany Building Permit Application I: \COMNEWTI.DOC (DST) 5/98 r .. COMMERCIAL PLAN SUBMITTAL REQUIREM r :.::. :: >> :: . : ::.::. �::: �. �::: : : ::: :::: ::: :::: .: : ::. :::::::: P! �::.::....:::: 1::. �::::::: ::..�:::.:::::::::.:�:��::37:. in�:::AD W ..: ::::::::. .. ;. ........... :: v: .t :.::: :..:: ::?•i :' ?i:! ? {: {•i:,i.,i: ..r........: y::.v:: : :: 4 :•: $ii: ?. } "r: { {n; :: !: , i i ... ? . ; } v : .... ........... .. « u and :::a. # +ca ts : : . .;. i; : 'i' : .;. f......,. :.: a . ::.:.:. ' { '?: : ':{i:'«: >:<::: >:::<: :::::.:.: IpA.�iii ■ 0aIl eu a r ::t : >: : :.. .::.:. : ?: ii:•::.:ii:.iii::::i:.i: ?.i:. :... €e a emk ee::: a . ::.:.::.:::::::::::::.::: ::::::+.:::::::: i:. i:.> .:: ::::.:::::.:: :::::::::.:::?:. �:::::. �:::::::::::::: �:::::::.{.;::::: �::: :: :::: :::::: ::::::::::: � ....... ... � . � �n. the ...ti ?:: Y is n { :.. ..... . . . :: .::: .:::..::. :.:::. :?::.:: •.:i { :.f ' {: '•ii: ii:�i: { ?i:.: :4: }i: i }? iii <::: ?: {:: }Y .. X {.i iii: ii }iii? ^i: ^i: {.i: $iii %J ?y DISTRIBUTION TO PLANS OUT TO DST EXAMINERS (Note a.) TYPE OF SUBMITTAL TOTAL CPE PPE EPE CPE PPE EPE SITE 1 1 — — 3 (j,o,u) — — B (New or Add) 1 1 — — 3 (j,o,w) _ _ F (New or Add or Alt.) 3 3 — — 3 (j,o,f) M (New or Add. or Alt) 1 1 — — 2 6, — — B M (New or Add) 1 1 — — 3 (j,o,w) — — P (New, Add. or Alt) 2 — 2 — — 2(j,o) — B & M & P (New or Add.) 2 1 1 — 3 (j,o,w) 2(j,o) — E (New, Add, or Alt) 2 — — 2 _ — 2(j,o) B M& P& E (New, Add) 3 1 1 1 3 (j,o,w) 2(j,o) 2 (j,o) .............:......... :. �:.: ��:. 8.:::. 1'.. ��t :::.:.:::::.:. r..:........ .....r:::.:? ?.::.:::...:.. r....................r...... r.: .;:i.::::..,..........:.:....r. �,........... .......... ........::::.: r :. i r.... r....:: r..::::.::. ii{ i:. i:. i. �:::::::..:. �:::. �:: .....:r ............... +...... {j.....�.::::.� :'.: {.::.:. iii.:: ..... .... ......... r.....r... i.:::'i. >... :......... . :..:: ::...: r:.::...: .,. ..:::::.........� : :::::1:::::24:40 <� > {..:::..ri.�;. . .. .`r ........... r.... «: v: � :. �v : ? . :•r.•. :w::••: w�n.. . «:. � ..... :.? iiiii ''{= ij:•:}i�`:;iiii::+i+ :: fi« �v: - .: �... r...r ..... r. r.:.... ....r.:..r........ •. • ......r ...r:...:.. .......... .:•:• . . :::::.. :..:.... 8:• .. '�: is '.: ; { ?; ., . :: r:.:':. :v::.v::. ;:: r . y n ; . � {.::: v :::::... :............v .. ..� .�, . � :•i }iii: ^:4i: :..: �.. .... �. ��Mr. '�(T� ......................... .. .. ..:. ......... ......... .. n:... •_. :: rf.:v:. ::::4i:ti?�i�.:::: ?•rv::: w: :;:. :..n .. .:::.:'• :: :.. '� '.: i ...... ...... .... ... ......... :W . �4fL ...... ..:.. :......... r. r.. .... n......... .. ..... � ::...:: ... . ... .......... ..... r....... .... : :ii i '•? : i: ��: is :i -�:�� :��: •r�:ti�:: .............� ....: ...... ..... .. �::v: v:v: � . nv :•.�::.v: •. . .. .. ii ii::y j;:i:i ':;:: = ..,...., ....... r.........:..?:. �:::::::::::: rr::...:...?.:: r..:<.:{.:. iiiii:.:: �.: ::�.::.:.::............. ....... . . . ... . . . .. �i ........ KEY: NOTES: a. Before returning to DST, Plans examiner gets appropriate • =Job B = BUP number of revised plans from applicant, stamps and o = Office M = MEC completes, updates and adds actions. f = Fire P = PLM .::..: .. u E ELC es rya .( :::.' ..i ?. ti •: {.:.. , :..::.....: { {. 9.:: { {: :: ?.i ;::.?:.:: :::::::::::: .:.:::.::; ? «;: ? {:: F: .::.::: < ::::> : . ;:::: >'i::ii:::: >:. >:, w Wash. County F FPS c. FPS • a new permit category set as for fire sprinklers and fire alarms. d. Effective August 15, 1997, Tualatin Valley Fire and Rescue no longer requires a set of approved plans to be forwarded to their office. Exception, continue to forward a copy of approve fire sprinkler and fire alarm plans with calculations. I:lmatrix.Doc OVER - THE - COUNTER (OTC) PERMIT COMMERCIAL ( STRUCTURAL) BUILDING PERMIT CHECKLIST DESCRIPTION OF PROJECT: nrn f f �, a-! p A ,,7 /1 e FO e ,c r ,r q w/ • .L t t� •r //. *i4 I-/ /,f G n 7 )- '& (-3( 1r),`f 6c6 y CLASS OF WORK: .7 ` FLOOR AREAS: C/A. i EXTERIOR WALL CONSTRUCTION TYPE OF USE: 'v P . FIRST SQ. FT. N: S: E: W: TYPE OF CONSTR: SECOND SQ. FT. PROTECT OPENINGS ?: OCCUPANCY GRP: a- THIRD SQ. FT. N: S: E: W: OCCUPANCY LOAD: NA TOTAL SQ. FT. ROOF CONSTR: FIRE RET: STOR: HT: FT: i BSMNT: SQ. FT. i AREA SEP. RATED: BSMNT ?: MEZZ ?: GARAGE: SQ. FT. OCCU.SEP.RATED: I I FIRE FIRE SMOKE HANDICAP SPRINKLER: ALARM: DETECTOR: ACCESS: COMMERCIAL INSPECTION ACTIONS FEE MENU V • Foot/Found Post/Beam $ Z 2 4 Permit Fee Masonry Framing $ 1 1IeP ) Plan Review Insulation Shear Wall $ / I 5% State Surcharge Firewall Gyp Board $ 9 / FLS Plan Review Suspended Ceiling Sprinkler Rough -in $ Add'I Permit Fee Sprinkler Final Fire Alarm $ Add'I FLS Pln Smoke Detector Approach /Sidewalk $ Inspection Miscellaneous , Final $ MIS Fee L( )9b • 9 v FOR OFFICE USE ONLY: TYPE OS USE OPTIONS (COM= commercial; CMS = commercial manufactured structure) CLASS OF WORK OPTIONS FOR ALL PERMITS (NEW =new; Add = addition; ALT = alteration; ACS= accessory;FND- foundation; OTR= other; DEM= demolition; REP= repair; FPS =fire protection system, NOTE: USE OTR FOR FENCES, RETAINING WALLS, DETACHED DECKS, SIGNS, AWNINGS, CANOPIES) I: \ovrcntr2.doc (DST) 4/97 CITY OF TIGARD A ? A, 1 BUILDING PERMIT ,� DEVELOPMENT SERVICES PERMIT # ° BUP97 -0514 � # 13125 SW Ha11 Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 03/25/98 PARCEL: 26115BA -00600 SITE ADDRESS...: 16105 SW PACIFIC HWY SUBDIVISION • ZONING: BLOCK • LOT JURISDICTION:KIN REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION — CLASS OF WORK.:NEW FIRST • 14007 sf N:1HR S:1HR E:1HR W:1HR TYPE OF USE...:COM SECOND...: 14007 sf PROTECT OPENINGS? TYPE OF CONST.:5 -1HR 14007 ...: 0 sf N: S: E: W: OCCUPANCY GRP. :R1 TOTAL : 28014 sf ROOF CONST: FIRE RET ?: OCCUPANCY LOAD: 255 BASEMENT.: 0 sf AREA SEP. RATED: STOR.: 3 HT: 0 ft GARAGE...: 0 sf OCCU SEP. RATED:1HR BSMT ?:N MEZZ ?:N READ SETBACKS REQUIRED FLOOR LOAD • 50 psf LEFT: 0 ft RGHT: 0 ft FIR SPKL:Y SMOK DET.. :Y DWELLING UNITS: 0 FRNT: 0 ft REAR: 0 ft FIR ALRM:Y HNDICP ACC:Y BEDRMS: 0 BATHS: 0 IMP SURFACE: 0 PRO CORR:Y PARKING: 0 VALUE. $ : 2400377 Remarks: New construction of a 73 unit motel Owner: FEES KCM ASSOCIATES LLC type amount by date recpt 10895 SW FIFTH PLCK $ 3693.95 DRA 10/31/97 97- 300588 BEAVERTON OR 97005 FIRE $ 2273.20 DRA 10/31/97 97- 300588 PRMT $ 6185.50 B 03/25/98 98- 304392 Phone #: 643 -5721 5PCT $ 309.28 B 03/25/98 98- 304392 FIRE $ 201.00 B 03/25/98 98- 304392 Contractor: PLCK $ 326.63 B 03/25/98 98- 304392 SUPER ONE INC 10950 SW 5TH STE 150 BEAVERTON OR 97005 Phone #: 643 -5721 $ 12989.56 TOTAL Reg #..: 000571 REQUIRED INSPECTIONS This permit is issued subject to the regulations contained in the Foot /Found Insp Smoke detector i Tigard Municipal Code, State of Ore. Specialty Codes and all other Re i n f Steel Insp Appr/ s d w l k Insp applicable laws. All work will be done in accordance with Slab Insp Misc. I n s p e ct i o n approved plans. This permit will expire if work is not started Masonry Insp within 180 days of issuance, or if work is suspended for more Framing Insp than 188 days. ATTENTION: Oregon law requires you to follow the Roof n a i l n g Insp rules adopted by the Oregon Utility Notification Center. Those Insulation Insp rules are set forth in OAR 952 -N1-0910 through OAR 952-09101987. Shear Wa 11 Insp You many obtain a copy of these rules or direct questions to OUNC Gyp Board Insp by calling (503)246 -1987. Susp Ceilng Insp Reinforced concr Structural mason via . . (141ANILIP--- Permittee Signature: �y �ti�,�/ Issued By: - + + + + + + + + + + + + + + + + + + ++ + + ++ ++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ Call 639 -4175 by 7:00 p.m. for an inspection needed the next business day +++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ 1 i • CITY OF TIGARD C omm ercial Building Permit lc , Redd By _/ 13125 SW HALL BLVD. New Construction and Additions • /�� Date Reed 3i 9 -� TIGARD, OR 97223 ��, V Date to P.E. / /- s -a- (503) 63,9 -4171 Date to DST Permit ax ) j 7 ft ,f,„r Print or Type Related SWR it %N% Incomplete or illegible applications will not be accepted Called Job Name of Development/Project Best Western Address Street Address Suite Existing Building 0 New Building b 16105 S.W. Pacific H Bldg * I City /State Zr Building King City, OR "9 7224 Property Name Data KCM Associates LLC Existing Use of Building or Property: Owner Mailing Address Suite 10895 S.W. Fifth Vacant lot City /State Zip Phone Beaverton, OR 97005 643 -5721 Proposed Use of Building or Property: Name KCM Associates LLC 73 Unit motel Occupant Mailing Address Suite No. Of Stories: • 10895 S.W. Fifth 3 City /State Zip Phone Beaverton, OR 97005 643 -5721 Sq. Ft. Of Project Name 42,022 Super One, Inc. Occupancy Class(es) Contractor Mail A ddress suite 109 S .W. Fifth 150 R -1 (Prior to issuance City/State Phone Type(s) of Construction a copy of all Zip �'Pr 41* V -1 Hour licenses are required if Will this project have a Fire Suppression System? expired in C.O Beaverton, OR 97005 543 -5721 Yes XX - No data base) Oregon Const. Cont. Board Licit Exp. Date Project 54. (. t 42vv o ? t 1 7 S t itef,�s 57193 6 /9g Valuation $ 2,200,000.00 ,„,,, Iq ,� ` � Z ,, S z Name Americans with Disabilities Act (ADA) Architect Charles C. Hagel Valuation X 25% = $ Participation Z4 oa 1 3 ■ ? Mailing Address Suite Complete Accessibility Form 11580 S.W. 67th Plans Required: • See Matrix for number of sets to submit City/State Zip Phone on back Tigard, OR 97224 20 -3825 Engineer Name Fuller Design & Engineering I hereby acknowledge that I have read this application, that the information Mailing Address Suite given is correct. that I am the owner or authorized agent of the owner, and 2323 S.W. Iowa Street that plans submitted are in compliance with Oregon State Laws. City/State Zip Phone Portland, OR 97201 Signature of Owner/Agent Date indicate type of work: New to Addition 0 Demolition o 10/29/97 Accessory Structure 0 Fou ndation Only 0 Alteration 0 Contact Person Name Reoair 0 Other 0 Phone Andrew A. Ilg 643 -5721 Description of work: New construction of a 73 unit motel FOR OFFICE USE ONLY Map/rUt I Land Use: Notes: Parks: Estimated 0 of Employees TIP: 1 r dote: Site Work Permit Application must precede or accompany Building - ' ?ermitAppliction / / , N l /- 3 � 3 `'LS ? � 73 -.v + :\COMNEW.DOC (DST) 8/97 c / C!� 7, /S COMMERCIAL PLAN SUBMITAL 4 REQUIREMENT MATRIX . Applicant DSTs to Plans Examiner Plans Examiner to DSTs Initial No. Plans required to complete Plans Routing (processing (see note a.) Submitted TYPE OF SUBMITTAL ;::`::TOTAL;:';:; CPE PPE EPE CPE PPE EPE SITE ifig. ; ry >.01 : — — — — B (New or Add) — — 3 (j o w ) — — — ;.;..: >: :: ;:.: F (New or Add or Alt.) 3 3 (j,o, f) �'?��l; <r< < -- M Yi i:: . (New or Add. or Alt) ,,;: { < >; >;<;; 1 - - 2 (j,o) — — <:;: .;..: . I - - 3 V w) 'B & M New or Add �::;..,,:�'.;;•; — P (New, Add. or Alt) >F r> — 2 — -- — B & M & P (New or Add.) ' .: ' ° ` .: ' — 3 o w 2 0 — Y l .if: r li �;: : :;:m r 4 r /G: �7 , ) �, ) f:r E (New, Add, or Alt) . r ' JI W a i !4 — — — — 2(j,o) L B M & P & E Add) N: 1 1 1 3 (j,o.w) _(j,o) 2 (j,o) B or B & M (Alt) ;: ? : :` : < ` 1 — -- 2 ' o -- U� ) — B & M &I' Alt `` <<' > >! >'<> 1 2 — (j,o) — B & M& P &EAlt ::::::::::::::::::::::::::: 1 1 1 2 ' 2 ( ) V ,o ) U,o) 2 (j,o) NOTES: KEY: a. The applicant will be requested to submit the correct number of j = Job B = BUP revised plans plans when all plan review issues have been o = Office M = MEC resolved. f = Fire P = PLm u = USA E = ELC b : Shaded ;areasdesignares:uutaalsu6m0a : re uirements::::::::_ :.;<;: ::; w = Wash. County F = FPS h:vnatrie.Ooe Page No. 1 CASE HISTORY FOR CASE NO.: BUP97 -0514 BEST WESTERN 16105 SW PACIFIC HWY' 01/08/99 • • Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent . Done Done Date By BUPC005 Application received / / / / 10/31/97 • RECD DRA 11/05/97 BON BUPC008 Permit created / / / / 11/05/97 DONE . B 11/05/97 BON BUPCO10 Check for prcl. restrict. / / / / 11/05/97 King City must check parcel MEMO B 11/05/97 BON restrictions. • BUPC012 Plans routed to Plans Examiner / / / / 11/05/97 SENT B 11/05/97 BON BUPC015 Plan Review Ltr. to Ofc. Svcs: 11/17/97 / / 11/17/97 12/30/97 - Sent third letter on PEND RDP 02/23/98 RDP revisions to Arch. Also spoke with Fuller the Engineer on his calcs for the building - The figures are not correct. He will recheck these and send new sheets. 2/23/98 Sent revised letter on this date for the still outstanding isuues. • BUPCO26 Approved Plans routed to DSTS 11/17/97 / ,/ 03/24/98 SENT RDP 03/24/98 BON �_ • .BUPCO29 DST Post Review Completed / / / / 03/24/98 DONE B 03/24/98 BON BUPC090 (F) Ready to issue_ • / / / / 03/24/98 Rosie at City of King City okayed PASS B 03/24/98 BON release of permits.. 'Contractor expired in our database. • • BUPC100 (F) Issue permit / / / / 03/25/98 PASS B 03/25/98 CTR BUPC105 (F) Reprint Permit / / / / . 07/01/98 Reprinted for the revision of the DONE DEB 07/01/98 DRA keystone wall & fence. BUPC705 Foot /Found Insp 11/17/97 / / 04/23/98 Special Inspection required. PASS TLP 04/27/98' TLP Note: Exterior footings 1 -10 approved. ufer ground not shown to me at this time.:.. BUPC705 Foot /Found Insp / / / / 04/28/98 Stem wall on Line C & H from 1 -10 on FAIL RC 04/29/98 DGW • Line 1 from C to D and F to H. No hold -downs at this inspection. No • address posted. BUPC705 Foot /Found Insp 04/29/98 / / 04/09/98 cancelled by contractor request. CANC RC 04/29/98 J *H - BUPC705 Foot /Found Inep 04/29/98 / / 05/05/98 All perimeter footings approved. PASS RC 05/05/98 J *H Elevator base rebar to be verified by special inspector. Ufer stubup painted white - approved in exterior footing. BUPC705 Foot /Found Insp. / / / / 05/12/98 APPROVED EXCEPT FOR DRI.VETHRU AT SOUTH PART RC 05/12/98 J *H END Page No. 2 CASE HISTORY FOR CASE NO.: BUP97 -0514 • BEST WESTERN 16105 SW PACIFIC HWY 01/08/99 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By BUPC705 Foot /Found Insp / / / / 06/08/98 1. All footings must be below the frost FAIL RC 06/09/98 J *H line. 2. Provide engineer's report on rebar placement, concrete and bolt placement. 3. Concrete placed without inspection. 4. Do not backfill• until above corrections are complete and approved. BUPC705 Foot /Found Insp / / / / / / Inspection for keystone wall & 6' fence. 07/01/98 DRA BUPC716 Reinf Steel Insp 11/17/97 / / 06/09/98 engineer calls for *4 hoops 8" oc horiz. FAIL RC 06/10/98 ROC not ready insp. terminated due to contractor verbal abuse. do not place concrete. BUPC725 Slab Insp 11/17/97 / / 05/22/98 1. Need engineer's approval of epoxy FAIL RC 05/22/98 J *H hold -down attachment on interior HT22's. 2. If electrical permit is not issued by pour time, the electrical room must be blocked out from grid 11 to 17 and from E5 to H. 3. Not ready to inspect. DO NOT PLACE CONCRETE. BUPC725 Slab Insp / / / / 05/27/98 1. Need to resubmit plans showing FAIL RC 05/27/98 J *H engineering for prefabricated panels and for attachment to site built components. Specify holddowns and any connection between the prefab areas and site built. 2. Plans need to be submitted to State Of Oregon Building Codes Division for approval. 3. Do not place concrete for slab until plans have been approved and inspected by Washington County. BUPC725 Slab Insp / / / / 05/29/98 Slab & forms: PASS RC 06/24/98 J *H Remainder of footing and slab for main building. Slab for pool & spa not ready - Lifer approved. • BUPC725 Slab Insp / / / / 06 /05 /98'Approval for lobby area with mono pour PART RC 06/05/98 J *H footing. • BUPC725 Slab Insp / / / / 06/10/98 Slab /pier - footings pads on L. Rebar PASS RC 06/11/98 J *H for columns on .05 • Page No. 3 CASE HISTORY FOR CASE NO.: BUP97 -0514 BEST WESTERN 16105 SW PACIFIC HWY 01/08/99 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By • BUPC727 Masonry Insp 11/17/97 / / 07/29/98 rebar for blk sound wall at rear of prop PASS GS 07/30/98 GES BUPC727 Masonry Insp / / / / / / Inspection for keystone wall & 6' fence. 07/01/98 DRA BUPC727 Masonry Insp / / / / 10/05/98 PERIODIC VENEER INSP PART GS 10/05/98 GES BUPC727 Masonry Insp 10/13/98 / / 10/05/98 GS 10/13/98 J *H BUPC740 Framing Insp 11/17/97 / / / / Sheets 3 - 6 - and 7 have been revised. 06/03/98 RDP Be sure the approved plans you look at say "REVISED" BUPC740 Framing Insp • / / / / 08/25/98 BEHIND TUBS ONLY {LEAVE TOP OPEN FOR PART RC 08/25/98 ROC FIREBLOCK INSP. BUPC740 Framing Insp 08/26/98 / / 08/26/98 Alternate for plastic pipe penetrations NOTE RDP 08/26/98 RDP UL- WL2078 approved. Copy to Ron Church has been supplied. • BUPC740 Framing Insp / / / / 09/04/98 INSPECTION TERMINATED !!!! Too many PART RB 09/04/98 RB violations noted, ie. Draft stopping at 100 foot intervals in corridor, Elevator framin -ok, except check sprinkler detail fbr shaft area- none installed at this time, enclose all fixtures at rated ceiling (pool area) - ALSO, verify w /electrical engineer if enclosure will be adequate for high heat unit- shut -off when too hot, etc. • • • • • Page No. 4 CASE HISTORY FOR CASE NO.: BUP97 -0514 BEST WESTERN 16105 SW PACIFIC HWY 01/08/99 Action Description Req/ Schd/ End/ Action Notes' Disp By Update Upd Code Sent Done Done Date By BUPC740 Framing Insp / / / / 09/11/98 1st floor framing: FAIL GS 09/15/98 J *H 1. Suite #124 mech not complete - duct . • fans to 18 -inch min. above 2nd floor - ALL UNITS. 2. Put floor bath fan shafts. 3. Room 130 strap top plate, corridor wall, also room 132, 103. 4. Ledger under stair jacks at B -15. 5. Shaft for HW tanks not in. 6. Repair cut plate in sprinkler room. 7. Tenant laundry, ceiling not in. 8. Strap from t- valley lumber for pool roof trusses. • 9. Hurricane clips and end of pool trusses. 10. Box around speaker, fixture, meeting room, exercise room BFSK. 11. Public bathroom vent shaft needs to extend into soffet (no plastic plumbing). SOFFITS: 12. Attic access for carport (soffits okay, pass) combustion air for main laundry, check for hi -low supply cut sheet on sprinkler pipe (plastic). 13. Low voltage (wash co) looks to be 1 -hr. rated min. BUPC740 Framing Insp / / / / 09/14/98 See SHEAR & MISC. THIS DATE: PART GS 09/15/98 J *H 1ST FLOOR FRAMING APPROVED. OK TO INSULATE. BUPC740 Framing Insp 09/17/98 / / 09/16/98 2nd & 3rd floor framing: FAIL GS 09/17/98 J *H 1. Vent exhaust fan in stairways. 2. Reinforce ceiling joist room 226. 3. Fire caulk back to back electrical boxes. • 4. Firestop gray low voltage cables, top plate room 218. 5. Flat stud room 219. 6. Vent bath fans room 211, 213. 7. Repair joist room 208. Mechanical failed, soffets at rear of building not ready. • Page No. 5 CASE HISTORY FOR CASE NO.: BUP97 -0514 BEST WESTERN '16105 SW PACIFIC HWY 01/08/99 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By • ---- - -- ------ -- --- BUPC740 Framing Insp 09/17/98 / / 09/18/98 3rd floo wall framing okay, roof framing PART GS 09/20/98 J *H failed. Several lateral bracing missed (marked on truss details at job site). BUPC740 Framing Insp / / / / 09/28/98 repair floor joists cut for plm FAIL GS 10/01/98 GES BUPC740 Framing Insp / / / / 09/28/98 laterial bracing on roof trusses FAIL GS 10/01/98 GES BUPC740 Framing Insp / / / / 09/29/98 excluding roof PASS GS 10/01/98 GES BUPC740 Framing Insp / / / / 10/05/98 DROPED CEILING SUITE 224 PART GS 10/05/98 GES BUPC740 Framing Insp / / / / 10/16/98 soffets in lobby and pool area pass PART GS 10/16/98 GES BUPC742 Roof nailng Insp 11/17/97 / / 07/16/98 missed nailing thru -out • FAIL RB 07/16/98 RB BUPC742 Roof nailng Insp / / / / 07 /30 /98.canopy only PASS RC 07/30/98 ROC BUPC742 Roof nailng Insp / / /. / 07/30/98 lobby -pool not ready FAIL RC 07/30/98 ROC BUPC742 Roof nailng Insp / / / / 07/20/98 Upper roof only (3rd story) PART RC 07/30/98 J *H BUPC742 Roof nailng Insp 08/02/98 / / 07/31/98 Exterior gable ends approved. Roof over PART RC 08/02/98 J *H pool & lobby nailing approved. BUPC750 Insulation Insp 11/17/97 / / / / All exterior glass shall have a shading 09/22/98 J *H coefficient of 0.57 BUPC750 Insulation Insp / / / / 09/22/98 Insulation on interior shear walls first PART GS. 09/22/98 J *H floor: pass. ■ Insulation pool area interior walls: 1) replace fallen insulation, 2) insulate sides of skylights (fail), 3) vapor barrier oh ceiling (fail). BUPC750 Insulation Insp / / / / 09/28/98 all 3 floors PASS GS 10/01/98 GES 3 BUPC757 Shear Wall Insp 11/17/97 / / 07/01/98 exterior sheathing and interior PART TLP 07/08/98 TLP sheathing and interior sheathing nailing only no anchors approved • • Page No. 6 CASE HISTORY FOR CASE NO.. BUP97 -0514 BEST WESTERN 16105 SW PACIFIC HWY 01/08/99 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By BUPC757 Shear Wall Insp / / / / 07/13/98 Not Ready !!!! FAIL RB 12/17/98 GES Special Inspection Report required for epoxy of HD's SPEC FINAL INSP BY BRAUN I•NTERTEC REC Fps 121798] BUPC757 Shear Wall Insp / / / / 09/14/98 FRAMING APPROVED, FRAMING & EXT. SHEAR PART GS 09/15/98 J *H NOTES: 1. Support bottom of stair jacks (leave one gyp board off for inspection. • 2. Shaft for HW tanks not in '(needs to be left off for now). • SEE MISC. INSPECTION THIS DATE. • BUPC757 Shear Wall Insp / / / / 09/28/98 PART GS 10/01/98 GES BUPC757 Shear Wall Insp / /, / / 10/06/98 INTERIOR SHEAR COMPLETED ALSO, 1ST LAYER PASS GS 10/14/98 J *H • CEILING IN LOBBY. BUPC757, Shear Wall Insp / / / / 10/06/98 Ceilings in lobby, pass PASS GS 10/14/98 J *H BUPC758 Firewall Insp / / / / 07/13/98 Gyperete prep- ok (PREP FOR SHOWERS) PART RB 07/13/98 RB BUPC758 Firewall Insp / / / / 07/13/98 See gyp. inspection this date- prep PART RB 07/13/98 RB only- no gyp installed yet. Add studs where missed. BUPC758 Firewall Insp / / / / 07/21/98 all exterior walls except soffitt and PASS RC 07/29/98 DGW gable ends BUPC758 Firewall Insp 08/02/98 / / 07/31/98 Exterior gable ends approved, roof over PASS RC 08/02/98 J *H pool & lobby nailing. BUPC758 Firewall Insp / / / / 08/25/98 1ST LAYER ON SOFFITT EXCEPT BACK FROM PASS RC 08/25/98 ROC 1.25 TO 15.75. BUPC758 Firewall Insp / / / / 08/13/98 Soffits at exterior driveway area only PART RC 08/26/98 J *H approved. BUPC760 Gyp Board Insp 11/17/97 / / 08/04/98 Notching or boring in bearing walls FAIL RC 08/04/98. ) *H cannot exceed 25% or 7 /Bths -inch in a 3 1/2 -inch stud. 40% in non - bearing walls. All joints in firewall not on framing members must be firecaulked. • Page No. 7 CASE HISTORY FOR CASE NO.: BUP97 -0514 BEST WESTERN • 16105 SW PACIFIC HWY 01/08/99 • Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By BUPC760 Gyp Board Insp / / / / 07/13/98 Prep work behind showers. PART RB 07/13/98 RB Obtain plumbing approval at walls with plumbing. Insulate walls as needed; a given at location of showers. • BUPC760 Gyp Board Insp / / / / 07/28/98 exterior gyp.- called for gable ends- FAIL RB 07/28/98 RB incompleted. Interior shower compartments- remove drywall on plumbing wall, as to view stud supports for upper floors. Plumbing cover already approved by TLP- viewed card on site. • All fasteners shall be rated for 1 -hr wall. Also, provide adequate nailing as per Code specs for attachment of gypsum. Nails= 8" walls & 7" ceilings. BUPC760 Gyp Board Insp / / / / 08/12/98 BOTH LAYERS ON SOFFITT ON 17 FROM B TO H PART RC 08/12/98 ROC ,ON H FROM17 TO 15.5, ON B FROM 17 TO 15.75 NOTE: BOTH SHEETROCK BROKE ON SAME FRAMING MEMBER AT CORNER OF B & 15.75. BUPC760 Gyp Board Insp / / / / 08/19/98 Need fireblock & insulation before FAIL RC 08/19/98 J *H sheetrock. BUPC760 Gyp Board Insp / / / / 08/20/98 Fireblocking not completed. FAIL RC 08/20/98 J *H BUPC760 Gyp Board Insp / / / / 09/04/98 EXHAUST VENT SHAFTS: PART RB 09/04/98 RB 1015 am- first layer ok 1210 pm- second layer- missed- nailing at 8" oc- minimal. SHOWER COMPARTMENTS: • Nail drywall 8" oc at all perimeters /12" oc in field. BUPC760 Gyp Board Insp / / / / 09/22/98 Exterior gyp sheathing on rear soffets PART GS 09/22/98 J *H (pass). BUPC760 Gyp Board Insp / / / / 10/01/98 FIRST LAYER CEILING 3RD FL, EXCEPT CORR PART GS 10/01/98 GES AND STAIRS Page No. 8 CASE HISTORY FOR CASE NO.. BUP97 -0514 BEST WESTERN 16105 SW PACIFIC HWY 01/08/99 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent . Done Done Date By BUPC760 Gyp Board Insp / / / / 10/05/98 FIRST LAYER 3rdFL CORR LID PART GS 10/05/98 GES BUPC760 Gyp Board Insp / / / / 10/06/98 1st layer lobby lid PART GS 10/06/98 GES BUPC760 Gyp Board Insp / / / / 10/08/98 first layer pool area lid PART GS 10/08/98 GES BUPC760 Gyp Board Insp / / / / 10/09/98 FAIL canopy.lid not ready PART GS 10/09/98 GES BUPC760 Gyp Board Insp / / / / 10/14/98 1. 2nd floor walls approved. PART RC 10/15/98 J *H 2. 3rd floor walls & ceiling except • stair & storage room lids placed parralell to framing members. Either block and rescrew or replace perpendicular. 3. 2nd floor lid in storage room parralell to frame members. BUPC760 Gyp Board Insp / /. / / 10/12/98 1st layer ® canopy PASS GS 10/15/98 J *H BUPC760 Gyp Board Insp / / / / 10/21/98 walls and first layer cell in lobby and PASS GS 10/21/98 GES pool rms BUPC760 Gyp Board Insp / / / / 10/22/98 1st fl gypbd pass PART GS 10/23/98 GES BUPC762 Susp Ceilng Insp 11/17/97 / / 12/01/98 1ST AND 2ND FL CORRIDORS PART GS 12/01/98 GES obtain listed assembly for use at bundled cables penetrating firewalls slack wires for recessed can lights • OK TO COVER EXCEPT AT ABOVE LOCATIONS BUPC762 Susp Ceilng Insp / / / / 12/03/98 1st and 2nd fl pass except at cable PART GS 12/03/98 GES penetrations in firewall BUPC763 Reinforced concrete final rept 11/17/97 / / 12/17/98 REC GS 12/17/98 GES BUPC771 Fire - proofing final.report / / / / 07/13/98 Fire protection appears to be adequate PART RB 07/13/98 RB with minor bare spots... Submit Final Fire - Proofing Report from Special Inspector. BUPC786 Smoke detector insp 11/17/97 / / / / 11/17/97 RDP BUPC790 Appr /sdwlk Insp 11/17/97 / / / / N/A 07/28/98 RB BUPC792 Misc. Inspection 11/17/97 / / 07/13/98 Engineering keystone wall w/ CMU block PART RB 07/13/98 RB wall installed above. Greater than 4 -feet. PERMIT REQUIRED- Free - standing w/ no retaining. Maintain 2' footing and rebar req'mts. Page No. 9 CASE HISTORY FOR CASE NO.: BUP97 -0514 • BEST WESTERN 16105 SW PACIFIC HWY 01/08/99 Action Description Reg/ Schd/ End/ 'Action Notes Disp By Update Upd Code Sent Done Done Date By BUPC792 Misc. Inspection / / / / 07/23/98 FOOTING FOR MASONRY SOUND WALL APP. PASS RC 07/23/98 ROC NEED GEOGRID INSP. BEFORE PAVING. BUPC792 Misc. Inspection / / / / 07/28/98 Revise plans as per height of wall at N. PART RB 07/28/98 RB corner- in excess of 20 -feet for approximately 27 -feet each wall. Plans note 11 -feet w/ 5 -feet max at lower level w/ 6 -feet upper level, and 10" off -set between walls. Contour lines identify 8 -feet from top of wall to base of wall. Existing 20 -feet BUPC792 Misc. Inspec ;ion / / / / 08/28/98 2ND LAYER ON2ND FLOOR SOFFITT EXCEPT PASS RC 08/28/98 ROC BACKOF BLDG FROM 1.25 - 15.75 BUPC792 Misc. Inspection / / / / 08/28/98 ELEVATOR SHAFT FRAMING FAIL RC 08/28/98 ROC 1. PLACE STUDS WHERE CUT FOR PLUMBING 2. STRAP WALLS WHERE CUT FOR PLUMBING. 3. FIREBLOCK PLUMBING, WIRES, HOLES AND CRACKS AT EACH FLOOR /CEILING AND WALL PENETRATIONS BUPC792 Misc. Inspection / / / / 09/15/98 PART GS 09/15/98 J *H BUPC792 Misc. Inspection / / / / 09/14/98 1. Renail lid 2 places (marked). PART GS 09/15/98 J *H 2. Public bathroom vent shaft not ready. BUPC792 Misc. Inspection / / / / 09/24/98 construction change of vent fan chases, PASS GS 09/24/98 GES see letter and drawing in file from Chris Baker [USG], stamped by Jim Harris • arch. BUPC792 Misc. Inspection / / / / 10/01/98 RC CHANNEL 2ND FL WALLS AND CEILING PART GS 10/01/98 GES RC CHANNEL 1ST FL CEILINGS PASS. BUPC792 Misc. Inspection ' / / / / 10/01/98 DRAFT STOP COVERINGS IN ATTIC PASS PASS GS 10/01/98 GES BUPC792 Misc. Inspection /. / / / 11/03/98 draft stop in soffets in motel laundry PASS GS 11/04/98 GES • • Page No. 10 CASE HISTORY FOR CASE NO.: BUP97 -0514 BEST WESTERN 16105 SW PACIFIC HWY 01/08/99 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done • Date By BUPC792 Misc. Inspection / / / / 12/16/98 Received Special Inspection Report (not NOTE JH 12/23/98 J *H marked as final summary and showing wrong address). Report from Braun Intertec shows work in accordance with plans for Concrete and Reinforcing and Epoxy Anchors. Routed to file 122398/jh BUPC802 Final Inspection 11/17/97 / / / / No final or occupancy permit without 10/14/98 J *H approval by King City Manager. The applicant has chosen to pay their TIF fee prior to final. Please require written authorization from King City BUPC802 Final Inspection / / / / 01/06/99 PART (1ST FL AND SITE; address, FAIL GS 01/06/99 GES HCparking as discussed, final summary letters, glass at pool does not meet shadding coe of .57 submit energy calks for tradeoff, retest of some strobes, adjust closures rms. 100, 107, mens bthrm, laundry shute, double doors need astric and possibly coordinaters, max space beneth doors; single 3/8 ", double 1/4 ", HC signagemaids bth door, make • guests laundry sink accessable, need cleanout and seal around pipe at wall in contintal brfks kitchen BUPC802 Final Inspection / / / / 01/07/99 PART 2nd and 3rd fls; adjust closures FAIL GS 01/07/99 GES doors 324, 318, 204, 234 seats for HC tubs laundry shuts access doors are listed for horiz assembly, provide documentation approving vertical application also spring closures req. BUPC802 Final Inspection / / / / 01/08/99 bld final approved pending final PASS GS 01/08/99 JT approval from king city 1/8/99 King City approval letter received. Jeanne T. BUPC950 (F) Issue Cert. of Occupancy / / / / 01/08/99 01/08/99 JT CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 - L Business Line: 639 -4171 7 U 5.` UP Date Requested ( ? Vt. l AM PM "B4, 7 8, (> t_ L 5 Location I (� ( S- i Suite MEC 7 - a y3 6 Contact Person Ph r I OD-42 2 Q •PeiVF 9 g'- n l 7 7 Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT 9 7- cape, Y Post & Beam Ext Sheath /Shear Int Sheath/Shear Framing Insulation • Drywall Nailing � Firewall - / 1 • _ / Fire Sprinkler . Fire Alarm Susp'd Ceiling , �.�i� : �.� Roof (� Misc: S � - _ e . .�� _• _Or — -a . - i 'PLUMBING / Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART., FAIL ECHANIC Post & Beam Rough In Gas Line Smo e Dampers Ji • PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final A� PART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date / — `� / c� Inspector Ext Other ASS PART FAIL DO NOT REMOVE this inspection record from the job site.