Permit CITY OF TIGARD
DEVELOPMENT SERVICES BUILDING PERMIT
PERM I T # • BUP97 -0514
13125 SW Hall Blvd., Tigard, 0R 99722 (5 6 -4 DATE ISSUED: 07 / 01 / 98
PARCEL: 2S115BA -00600
SITE ADDRESS...: 16105 SW PACIFIC HWY
SUBDIVISION • ZONING:R -12
BLOCK • LOT • JURISDICTION:KIN
REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION —
CLASS OF WORK.:NEW FIRST • 14007 sf N:1HR S:1HR E:1HR W:1HR
TYPE OF USE...:COM SECOND...: 14007 sf PROTECT OPENINGS?
TYPE OF C0NST.:5 -1HR 14007 ...: 0 sf N: S: E: W:
OCCUPANCY GRP.:R1 TOTAL : 28014 sf ROOF CONST: FIRE RET ?:
OCCUPANCY LOAD: 255 BASEMENT.: 0 sf AREA SEP. RATED:
STOR.: 0 HT: 0 ft GARAGE...: 0 sf OCCU SEP. RATED:1HR
BSMT ?:N MEZZ ?:N READ SETBACKS REQUIRED
FLOOR LOAD • 50 psf LEFT: 0 ft RGHT: 0 ft FIR SPKL:Y SMOK DET..:Y
DWELLING UNITS: 0 FRNT: 0 ft REAR: 0 ft FIR ALRM:Y HNDICP ACC:Y
BEDRMS: 0 BATHS: 0 IMP SURFACE: 0 PRO CORR:Y PARKING: 0
VALUE. $ : 2400377
Remarks : New construction of a 73 unit motel
Owner: FEES
KCM ASSOCIATES LLC type amount by date recpt
10895 SW FIFTH PLCK $ 3693.95 DRA 10/31/97 97- 300588
BEAVERTON OR 97005 FIRE $ 2273.20 DRA 10/31/97 97- 300588
PRMT $ 6185.50 B 03/25/98 98- 304392
Phone #: 643 -5721 5PCT $ 309.28 B 03/25/98 98- 304392
FIRE $ 201.00 B 03/25/98 98- 304392
Contractor: PLCK $ 326.63 B 03/25/98 98- 304392
SUPER ONE INC PRMT $ 229.00 DEB 07/01/98 98- 306967
10950 SW 5TH PLCK $ 148.85 DEB 07/01/98 98- 306967
STE 150 Additional fees not shown here
BEAVERTON OR 97005
Phone #: 643 -5721 $ 13470.46 TOTAL
Reg #..: 000571
-- REQUIRED ACTIONS or INSPECTIONS--- -
This permit is issued subject to the regulations contained in the Foot /Found Insp Slab Insp
Tigard Municipal Code, State of Ore. Specialty Codes and all other Foot /Found Insp Masonry Insp
applicable laws. All work will be done in accordance with Foot /Found Insp Masonry Insp
approved plans. This permit will expire if work is not started Foot /Found Insp Framing Insp
within 180 days of issuance, or if work is suspended for more Foot/Found Insp Roof n a i l n g Insp
than 180 days. ATTENTION: Oregon law requires you to follow the Foot/Found Insp Insulation Insp
rules adopted by the Oregon Utility Notification Center. Those Foot /Found Insp Shear Wall Insp
rules are set forth in OAR 952-001 -0010 through OAR 952- 00101987. R e i n f Steel Insp Gyp Board Insp
You many obtain a copy of these rules or direct questions to OUNC Slab Insp Su s p Ce i l n g Insp
by calling (503)246 -1987. Slab Insp Reinforced concr
Slab I Structural mason
Slab nsp Smoke detector i
/� '
Permittee Signature: / a.1i...1.lI.1 e� Issued y.
1
Call 639 -4175 by 7:00 p.m. for an inspection needed the next business day
+++++++++++++++++++++++++++++++++++++++++++++++ + ++ + + + + + ++ + ++ + + + + + + + + + + + + + + + + ++
C` Building Permit Application OF TIGARD Commercial Buildin Pit A licati Rec'd Bel • 13125 SW HALL BLVD. Tenant Improvement
TIGARD, OR 97223 / it Date Recd '/ " Date to P.E. r a , , (503) 639 -4171
Date 1 y -P
Permit it l�it.Ap 17 0 �' /�/
Print or Type Related WR#
Incomplete or illegible applications will not be accepted Called — — --
Name of Development/Project Existing Building ❑ New Building ❑
Job Best Western
Address Street Address Suite Building
16105 SW PAC. Hwy Data
Bldg # City /State Zip Existing Use of Building or Property:
King City, OR 9/22
Name
Property KCM Associates L.L.C. Proposed Use of Building or Property:
Owner Mailing Address Suite
10895 SW Fifth
No. Of Stories:
City /State Zi Phone
3eaverton, 01� 97005
643 -5421 Sq. Ft Of Project
Occupant Name •
Occupancy Class(es)
Name
Contractor Super One, Inc . Type(s) of Construction
Prior to permit Mailing Address Suite
issuance, a copy 10950 SW F i t h 150 Will this project have a Fire Suppression System?
of all licenses Yes ❑ No,
are required if City/State Zi p Phone
expired in C.O.T. 3eaverton , OR 9700_3 Americans with Disabilities Act (ADA)
database 643-5721 Valuation X 25% - Participation
Oregon Const. Cont. Board Licit Exp. Date Complete Acces ill \ orm
57193 06/02/00 Project $ �.
Name Valuation 37) 5 S
Architect Plans Required: See Matrix for number of sets to submit
Mailing Address Suite 2- on back
City/State Zip Phone I hereby acknowledge that I have read this application, that the information
given is correct, that I am the owner or authorized agent of the owner, and
Engineer
Name that plans submitted are in compliance with Oregon State Laws.
Robert Race Signature of Owner /Agent Date
Mailing Address Suite
444 W. 78th St. Contact Person Name Phone
3?uomington zi 55 4S i l ne
; 800) 747 -8971
FOR OFFICE USE ONLY
Indicate type of work: New 0 Addition 0 Demolition 0
Accessory Structure 0 Foundation Only 0 Alteration 0
Map/TL# I Land Use:
Repair 0 Other O Notes:
Description of work:
TIF: .
Note: Site Work Permit Application must precede or accompany Building
Permit Application
I: \COMNEWTI.DOC (DST) 5/98
r
..
COMMERCIAL PLAN SUBMITTAL
REQUIREM
r :.::. :: >> :: . :
::.::. �::: �. �::: : : ::: :::: ::: :::: .: : ::. :::::::: P! �::.::....:::: 1::. �::::::: ::..�:::.:::::::::.:�:��::37:. in�:::AD W ..: ::::::::.
.. ;. ........... :: v: .t :.::: :..:: ::?•i :' ?i:! ? {: {•i:,i.,i: ..r........: y::.v:: : :: 4 :•: $ii: ?. } "r: { {n; :: !: , i i ... ? . ; } v : .... ........... ..
« u and :::a. # +ca ts : : . .;. i; : 'i' : .;. f......,. :.: a . ::.:.:. ' { '?: : ':{i:'«: >:<::: >:::<:
:::::.:.: IpA.�iii ■ 0aIl eu a r ::t : >: : :.. .::.:. : ?: ii:•::.:ii:.iii::::i:.i: ?.i:.
:... €e a emk ee::: a . ::.:.::.:::::::::::::.:::
::::::+.:::::::: i:. i:.> .:: ::::.:::::.:: :::::::::.:::?:. �:::::. �:::::::::::::: �:::::::.{.;::::: �::: :: :::: :::::: ::::::::::: � ....... ... � . � �n. the
...ti ?:: Y is n { :.. ..... . . . :: .::: .:::..::. :.:::. :?::.:: •.:i { :.f ' {: '•ii: ii:�i: { ?i:.: :4: }i: i }? iii <::: ?: {:: }Y .. X {.i iii: ii }iii? ^i: ^i: {.i: $iii %J ?y
DISTRIBUTION TO PLANS OUT TO DST
EXAMINERS (Note a.)
TYPE OF SUBMITTAL TOTAL CPE PPE EPE CPE PPE EPE
SITE 1 1 — — 3 (j,o,u) — —
B (New or Add) 1 1 — — 3 (j,o,w) _ _
F (New or Add or Alt.) 3 3 — — 3 (j,o,f)
M (New or Add. or Alt) 1 1 — — 2 6, — —
B M (New or Add) 1 1 — — 3 (j,o,w) — —
P (New, Add. or Alt) 2 — 2 — — 2(j,o) —
B & M & P (New or Add.) 2 1 1 — 3 (j,o,w) 2(j,o) —
E (New, Add, or Alt) 2 — — 2 _ — 2(j,o)
B M& P& E (New, Add) 3 1 1 1 3 (j,o,w) 2(j,o) 2 (j,o)
.............:.........
:. �:.: ��:. 8.:::. 1'.. ��t :::.:.:::::.:. r..:........ .....r:::.:? ?.::.:::...:.. r....................r...... r.: .;:i.::::..,..........:.:....r. �,........... .......... ........::::.: r
:. i
r.... r....:: r..::::.::. ii{ i:. i:. i. �:::::::..:. �:::. �:: .....:r ............... +...... {j.....�.::::.� :'.: {.::.:. iii.:: ..... .... ......... r.....r... i.:::'i. >...
:......... .
:..:: ::...: r:.::...: .,. ..:::::.........� : :::::1:::::24:40 <� > {..:::..ri.�;.
. .. .`r ........... r.... «: v: � :. �v : ? . :•r.•. :w::••: w�n.. . «:. � ..... :.? iiiii ''{= ij:•:}i�`:;iiii::+i+ :: fi« �v: -
.: �... r...r ..... r. r.:.... ....r.:..r........ •. • ......r ...r:...:.. .......... .:•:•
. . :::::.. :..:....
8:• .. '�: is '.: ; { ?; ., . :: r:.:':. :v::.v::. ;:: r . y n ; . � {.::: v :::::... :............v
.. ..� .�, . � :•i }iii: ^:4i: :..:
�.. .... �. ��Mr. '�(T� ......................... .. .. ..:. ......... ......... .. n:... •_. :: rf.:v:. ::::4i:ti?�i�.:::: ?•rv::: w: :;:. :..n .. .:::.:'• :: :.. '� '.: i
...... ...... .... ... ......... :W . �4fL ...... ..:.. :......... r. r.. .... n......... .. ..... � ::...:: ... . ... .......... ..... r....... .... : :ii i '•? : i: ��: is :i -�:�� :��: •r�:ti�::
.............� ....: ...... ..... .. �::v: v:v: � . nv :•.�::.v: •. . .. .. ii ii::y j;:i:i ':;:: =
..,...., ....... r.........:..?:. �:::::::::::: rr::...:...?.:: r..:<.:{.:. iiiii:.:: �.: ::�.::.:.::............. ....... . . . ... . . . .. �i ........
KEY:
NOTES:
a. Before returning to DST, Plans examiner gets appropriate
• =Job B = BUP
number of revised plans from applicant, stamps and o = Office M = MEC
completes, updates and adds actions. f = Fire P = PLM
.::..: ..
u E ELC
es rya .(
:::.' ..i ?. ti •: {.:..
, :..::.....: { {. 9.:: { {: :: ?.i ;::.?:.:: :::::::::::: .:.:::.::; ? «;: ? {:: F: .::.::: < ::::> : . ;:::: >'i::ii:::: >:. >:, w Wash. County F FPS
c. FPS
• a new permit category set as for fire sprinklers and fire alarms.
d. Effective August 15, 1997, Tualatin Valley Fire and Rescue no longer requires a set of
approved plans to be forwarded to their office.
Exception, continue to forward a copy of approve fire sprinkler and fire alarm plans with
calculations.
I:lmatrix.Doc
OVER - THE - COUNTER (OTC) PERMIT
COMMERCIAL ( STRUCTURAL) BUILDING PERMIT CHECKLIST
DESCRIPTION OF PROJECT: nrn f f �, a-! p A ,,7 /1 e
FO e ,c r ,r q w/ • .L t t� •r //.
*i4 I-/ /,f G n 7 )- '& (-3( 1r),`f 6c6 y
CLASS OF WORK: .7 ` FLOOR AREAS: C/A. i EXTERIOR WALL CONSTRUCTION
TYPE OF USE: 'v P . FIRST SQ. FT. N: S: E: W:
TYPE OF
CONSTR: SECOND SQ. FT. PROTECT OPENINGS ?:
OCCUPANCY GRP: a- THIRD SQ. FT. N: S: E: W:
OCCUPANCY LOAD: NA TOTAL SQ. FT. ROOF CONSTR: FIRE RET:
STOR: HT: FT: i BSMNT: SQ. FT. i AREA SEP. RATED:
BSMNT ?: MEZZ ?: GARAGE: SQ. FT. OCCU.SEP.RATED:
I I
FIRE FIRE SMOKE HANDICAP
SPRINKLER: ALARM: DETECTOR: ACCESS:
COMMERCIAL INSPECTION ACTIONS FEE MENU
V • Foot/Found Post/Beam $ Z 2 4 Permit Fee
Masonry Framing $ 1 1IeP ) Plan Review
Insulation Shear Wall $ / I 5% State Surcharge
Firewall Gyp Board $ 9 / FLS Plan Review
Suspended Ceiling Sprinkler Rough -in $ Add'I Permit Fee
Sprinkler Final Fire Alarm $ Add'I FLS Pln
Smoke Detector Approach /Sidewalk $ Inspection
Miscellaneous , Final $ MIS Fee
L( )9b • 9 v
FOR OFFICE USE ONLY:
TYPE OS USE OPTIONS (COM= commercial; CMS = commercial manufactured structure)
CLASS OF WORK OPTIONS FOR ALL PERMITS (NEW =new; Add = addition; ALT = alteration; ACS= accessory;FND- foundation;
OTR= other; DEM= demolition; REP= repair; FPS =fire protection system, NOTE: USE OTR FOR FENCES, RETAINING
WALLS, DETACHED DECKS, SIGNS, AWNINGS, CANOPIES)
I: \ovrcntr2.doc (DST) 4/97
CITY OF TIGARD
A ? A, 1 BUILDING PERMIT
,� DEVELOPMENT SERVICES PERMIT # ° BUP97 -0514 � # 13125 SW Ha11 Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 03/25/98
PARCEL: 26115BA -00600
SITE ADDRESS...: 16105 SW PACIFIC HWY
SUBDIVISION • ZONING:
BLOCK • LOT JURISDICTION:KIN
REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION —
CLASS OF WORK.:NEW FIRST • 14007 sf N:1HR S:1HR E:1HR W:1HR
TYPE OF USE...:COM SECOND...: 14007 sf PROTECT OPENINGS?
TYPE OF CONST.:5 -1HR 14007 ...: 0 sf N: S: E: W:
OCCUPANCY GRP. :R1 TOTAL : 28014 sf ROOF CONST: FIRE RET ?:
OCCUPANCY LOAD: 255 BASEMENT.: 0 sf AREA SEP. RATED:
STOR.: 3 HT: 0 ft GARAGE...: 0 sf OCCU SEP. RATED:1HR
BSMT ?:N MEZZ ?:N READ SETBACKS REQUIRED
FLOOR LOAD • 50 psf LEFT: 0 ft RGHT: 0 ft FIR SPKL:Y SMOK DET.. :Y
DWELLING UNITS: 0 FRNT: 0 ft REAR: 0 ft FIR ALRM:Y HNDICP ACC:Y
BEDRMS: 0 BATHS: 0 IMP SURFACE: 0 PRO CORR:Y PARKING: 0
VALUE. $ : 2400377
Remarks: New construction of a 73 unit motel
Owner: FEES
KCM ASSOCIATES LLC type amount by date recpt
10895 SW FIFTH PLCK $ 3693.95 DRA 10/31/97 97- 300588
BEAVERTON OR 97005 FIRE $ 2273.20 DRA 10/31/97 97- 300588
PRMT $ 6185.50 B 03/25/98 98- 304392
Phone #: 643 -5721 5PCT $ 309.28 B 03/25/98 98- 304392
FIRE $ 201.00 B 03/25/98 98- 304392
Contractor: PLCK $ 326.63 B 03/25/98 98- 304392
SUPER ONE INC
10950 SW 5TH
STE 150
BEAVERTON OR 97005
Phone #: 643 -5721 $ 12989.56 TOTAL
Reg #..: 000571
REQUIRED INSPECTIONS
This permit is issued subject to the regulations contained in the Foot /Found Insp Smoke detector i
Tigard Municipal Code, State of Ore. Specialty Codes and all other Re i n f Steel Insp Appr/ s d w l k Insp
applicable laws. All work will be done in accordance with Slab Insp Misc. I n s p e ct i o n
approved plans. This permit will expire if work is not started Masonry Insp
within 180 days of issuance, or if work is suspended for more Framing Insp
than 188 days. ATTENTION: Oregon law requires you to follow the Roof n a i l n g Insp
rules adopted by the Oregon Utility Notification Center. Those Insulation Insp
rules are set forth in OAR 952 -N1-0910 through OAR 952-09101987. Shear Wa 11 Insp
You many obtain a copy of these rules or direct questions to OUNC Gyp Board Insp
by calling (503)246 -1987. Susp Ceilng Insp
Reinforced concr
Structural mason
via . . (141ANILIP---
Permittee Signature: �y �ti�,�/ Issued By: -
+ + + + + + + + + + + + + + + + + + ++ + + ++ ++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++
Call 639 -4175 by 7:00 p.m. for an inspection needed the next business day
+++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++
1
i •
CITY OF TIGARD
C omm ercial Building Permit lc , Redd By _/
13125 SW HALL BLVD. New Construction and Additions • /�� Date Reed 3i 9 -�
TIGARD, OR 97223 ��, V Date to P.E. / /- s -a-
(503) 63,9 -4171 Date to DST
Permit ax ) j 7 ft
,f,„r Print or Type Related SWR it
%N% Incomplete or illegible applications will not be accepted Called
Job Name of Development/Project
Best Western
Address Street Address Suite Existing Building 0 New Building b
16105 S.W. Pacific H
Bldg * I City /State Zr Building
King City, OR "9 7224
Property Name Data
KCM Associates LLC Existing Use of Building or Property:
Owner Mailing Address Suite
10895 S.W. Fifth Vacant lot
City /State Zip Phone
Beaverton, OR 97005 643 -5721 Proposed Use of Building or Property:
Name
KCM Associates LLC 73 Unit motel
Occupant Mailing Address Suite No. Of Stories:
•
10895 S.W. Fifth 3
City /State Zip Phone
Beaverton, OR 97005 643 -5721 Sq. Ft. Of Project
Name 42,022
Super One, Inc. Occupancy Class(es)
Contractor Mail A ddress suite
109 S .W. Fifth 150 R -1
(Prior to issuance City/State Phone Type(s) of Construction
a copy of all Zip �'Pr 41* V -1 Hour
licenses are
required if Will this project have a Fire Suppression System?
expired in C.O Beaverton, OR 97005 543 -5721 Yes XX - No
data base)
Oregon Const. Cont. Board Licit Exp. Date Project 54. (. t 42vv o ? t 1 7 S t itef,�s
57193 6 /9g Valuation $ 2,200,000.00 ,„,,, Iq ,� ` � Z ,, S z
Name Americans with Disabilities Act (ADA)
Architect Charles C. Hagel Valuation X 25% = $ Participation Z4 oa 1 3 ■ ?
Mailing Address Suite Complete Accessibility Form
11580 S.W. 67th Plans Required: • See Matrix for number of sets to submit
City/State Zip Phone on back
Tigard, OR 97224 20 -3825
Engineer Name
Fuller Design & Engineering I hereby acknowledge that I have read this application, that the information
Mailing Address Suite given is correct. that I am the owner or authorized agent of the owner, and
2323 S.W. Iowa Street that plans submitted are in compliance with Oregon State Laws.
City/State Zip Phone
Portland, OR 97201 Signature of Owner/Agent Date
indicate type of work: New to Addition 0 Demolition o 10/29/97
Accessory Structure 0 Fou ndation Only 0 Alteration 0 Contact Person Name
Reoair 0 Other 0
Phone
Andrew A. Ilg 643 -5721
Description of work:
New construction of a 73 unit motel FOR OFFICE USE ONLY
Map/rUt I Land Use:
Notes:
Parks: Estimated 0 of Employees TIP:
1
r
dote: Site Work Permit Application must precede or accompany Building - '
?ermitAppliction / / , N l /- 3 � 3
`'LS ? � 73 -.v
+ :\COMNEW.DOC (DST) 8/97 c / C!� 7, /S
COMMERCIAL PLAN SUBMITAL 4
REQUIREMENT MATRIX .
Applicant DSTs to Plans Examiner Plans Examiner to DSTs
Initial No. Plans required to complete
Plans Routing (processing (see note a.)
Submitted
TYPE OF SUBMITTAL ;::`::TOTAL;:';:; CPE PPE EPE CPE PPE EPE
SITE ifig. ; ry >.01 : — — — —
B (New or Add) — — 3 (j o w ) — — —
;.;..: >: :: ;:.:
F (New or Add or Alt.) 3 3 (j,o, f)
�'?��l; <r< < --
M Yi i:: .
(New or Add. or Alt) ,,;: { < >; >;<;; 1 - - 2 (j,o) — —
<:;: .;..: . I - - 3 V w)
'B & M New or Add �::;..,,:�'.;;•; —
P (New, Add. or Alt) >F r> — 2 — -- —
B & M & P (New or Add.) ' .: ' ° ` .: ' — 3 o w 2 0 —
Y l .if: r li �;: : :;:m r 4 r /G: �7 , ) �, )
f:r
E (New, Add, or Alt) . r ' JI W a i !4 — — — — 2(j,o)
L B M & P & E Add) N: 1 1 1 3 (j,o.w) _(j,o) 2 (j,o)
B or B & M (Alt) ;: ? : :` : < ` 1 — -- 2 ' o --
U� ) —
B & M &I' Alt `` <<' > >! >'<> 1 2 — (j,o) —
B & M& P &EAlt ::::::::::::::::::::::::::: 1 1 1 2 ' 2
( ) V ,o ) U,o) 2 (j,o)
NOTES: KEY:
a. The applicant will be requested to submit the correct number of j = Job B = BUP
revised plans plans when all plan review issues have been o = Office M = MEC
resolved. f = Fire P = PLm
u = USA E = ELC
b : Shaded ;areasdesignares:uutaalsu6m0a : re uirements::::::::_ :.;<;: ::; w = Wash. County F = FPS
h:vnatrie.Ooe
Page No. 1 CASE HISTORY FOR CASE NO.: BUP97 -0514
BEST WESTERN
16105 SW PACIFIC HWY'
01/08/99
•
•
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent . Done Done Date By
BUPC005 Application received / / / / 10/31/97 • RECD DRA 11/05/97 BON
BUPC008 Permit created / / / / 11/05/97 DONE . B 11/05/97 BON
BUPCO10 Check for prcl. restrict. / / / / 11/05/97 King City must check parcel MEMO B 11/05/97 BON
restrictions.
•
BUPC012 Plans routed to Plans Examiner / / / / 11/05/97 SENT B 11/05/97 BON
BUPC015 Plan Review Ltr. to Ofc. Svcs: 11/17/97 / / 11/17/97 12/30/97 - Sent third letter on PEND RDP 02/23/98 RDP
revisions to Arch. Also spoke with
Fuller the Engineer on his calcs for the
building - The figures are not correct.
He will recheck these and send new
sheets. 2/23/98 Sent revised letter on
this date for the still outstanding
isuues.
•
BUPCO26 Approved Plans routed to DSTS 11/17/97 / ,/ 03/24/98 SENT RDP 03/24/98 BON
�_ • .BUPCO29 DST Post Review Completed / / / / 03/24/98 DONE B 03/24/98 BON
BUPC090 (F) Ready to issue_ • / / / / 03/24/98 Rosie at City of King City okayed PASS B 03/24/98 BON
release of permits..
'Contractor expired in our database.
•
•
BUPC100 (F) Issue permit / / / / 03/25/98 PASS B 03/25/98 CTR
BUPC105 (F) Reprint Permit / / / / . 07/01/98 Reprinted for the revision of the DONE DEB 07/01/98 DRA
keystone wall & fence.
BUPC705 Foot /Found Insp 11/17/97 / / 04/23/98 Special Inspection required. PASS TLP 04/27/98' TLP
Note: Exterior footings 1 -10 approved.
ufer ground not shown to me at this
time.:..
BUPC705 Foot /Found Insp / / / / 04/28/98 Stem wall on Line C & H from 1 -10 on FAIL RC 04/29/98 DGW
• Line 1 from C to D and F to H. No
hold -downs at this inspection. No
•
address posted.
BUPC705 Foot /Found Insp 04/29/98 / / 04/09/98 cancelled by contractor request. CANC RC 04/29/98 J *H
- BUPC705 Foot /Found Inep 04/29/98 / / 05/05/98 All perimeter footings approved. PASS RC 05/05/98 J *H
Elevator base rebar to be verified by
special inspector. Ufer stubup painted
white - approved in exterior footing.
BUPC705 Foot /Found Insp. / / / / 05/12/98 APPROVED EXCEPT FOR DRI.VETHRU AT SOUTH PART RC 05/12/98 J *H
END
Page No. 2 CASE HISTORY FOR CASE NO.: BUP97 -0514 •
BEST WESTERN
16105 SW PACIFIC HWY
01/08/99
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
BUPC705 Foot /Found Insp / / / / 06/08/98 1. All footings must be below the frost FAIL RC 06/09/98 J *H
line.
2. Provide engineer's report on rebar
placement, concrete and bolt placement.
3. Concrete placed without inspection.
4. Do not backfill• until above
corrections are complete and approved.
BUPC705 Foot /Found Insp / / / / / / Inspection for keystone wall & 6' fence. 07/01/98 DRA
BUPC716 Reinf Steel Insp 11/17/97 / / 06/09/98 engineer calls for *4 hoops 8" oc horiz. FAIL RC 06/10/98 ROC
not ready insp. terminated due to
contractor verbal abuse.
do not place concrete.
BUPC725 Slab Insp 11/17/97 / / 05/22/98 1. Need engineer's approval of epoxy FAIL RC 05/22/98 J *H
hold -down attachment on interior HT22's.
2. If electrical permit is not issued by
pour time, the electrical room must be
blocked out from grid 11 to 17 and from
E5 to H.
3. Not ready to inspect. DO NOT PLACE
CONCRETE.
BUPC725 Slab Insp / / / / 05/27/98 1. Need to resubmit plans showing FAIL RC 05/27/98 J *H
engineering for prefabricated panels and
for attachment to site built components.
Specify holddowns and any connection
between the prefab areas and site built.
2. Plans need to be submitted to State
Of Oregon Building Codes Division for
approval.
3. Do not place concrete for slab until
plans have been approved and inspected
by Washington County.
BUPC725 Slab Insp / / / / 05/29/98 Slab & forms: PASS RC 06/24/98 J *H
Remainder of footing and slab for main
building.
Slab for pool & spa not ready - Lifer
approved.
•
BUPC725 Slab Insp / / / / 06 /05 /98'Approval for lobby area with mono pour PART RC 06/05/98 J *H
footing.
•
BUPC725 Slab Insp / / / / 06/10/98 Slab /pier - footings pads on L. Rebar PASS RC 06/11/98 J *H
for columns on .05
•
Page No. 3 CASE HISTORY FOR CASE NO.: BUP97 -0514
BEST WESTERN
16105 SW PACIFIC HWY
01/08/99
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
•
BUPC727 Masonry Insp 11/17/97 / / 07/29/98 rebar for blk sound wall at rear of prop PASS GS 07/30/98 GES
BUPC727 Masonry Insp / / / / / / Inspection for keystone wall & 6' fence. 07/01/98 DRA
BUPC727 Masonry Insp / / / / 10/05/98 PERIODIC VENEER INSP PART GS 10/05/98 GES
BUPC727 Masonry Insp 10/13/98 / / 10/05/98 GS 10/13/98 J *H
BUPC740 Framing Insp 11/17/97 / / / / Sheets 3 - 6 - and 7 have been revised. 06/03/98 RDP
Be sure the approved plans you look at
say "REVISED"
BUPC740 Framing Insp • / / / / 08/25/98 BEHIND TUBS ONLY {LEAVE TOP OPEN FOR PART RC 08/25/98 ROC
FIREBLOCK INSP.
BUPC740 Framing Insp 08/26/98 / / 08/26/98 Alternate for plastic pipe penetrations NOTE RDP 08/26/98 RDP
UL- WL2078 approved. Copy to Ron Church
has been supplied.
•
BUPC740 Framing Insp / / / / 09/04/98 INSPECTION TERMINATED !!!! Too many PART RB 09/04/98 RB
violations noted, ie. Draft stopping at
100 foot intervals in corridor, Elevator
framin -ok, except check sprinkler detail
fbr shaft area- none installed at this
time, enclose all fixtures at rated
ceiling (pool area) - ALSO, verify
w /electrical engineer if enclosure will
be adequate for high heat unit- shut -off
when too hot, etc.
•
•
•
•
•
Page No. 4 CASE HISTORY FOR CASE NO.: BUP97 -0514
BEST WESTERN
16105 SW PACIFIC HWY
01/08/99
Action Description Req/ Schd/ End/ Action Notes' Disp By Update Upd
Code Sent Done Done Date By
BUPC740 Framing Insp / / / / 09/11/98 1st floor framing: FAIL GS 09/15/98 J *H
1. Suite #124 mech not complete - duct .
• fans to 18 -inch min. above 2nd floor -
ALL UNITS.
2. Put floor bath fan shafts.
3. Room 130 strap top plate, corridor
wall, also room 132, 103.
4. Ledger under stair jacks at B -15.
5. Shaft for HW tanks not in.
6. Repair cut plate in sprinkler room.
7. Tenant laundry, ceiling not in.
8. Strap from t- valley lumber for pool
roof trusses.
• 9. Hurricane clips and end of pool
trusses.
10. Box around speaker, fixture, meeting
room, exercise room BFSK.
11. Public bathroom vent shaft needs to
extend into soffet (no plastic
plumbing).
SOFFITS:
12. Attic access for carport (soffits
okay, pass) combustion air for main
laundry, check for hi -low supply cut
sheet on sprinkler pipe (plastic).
13. Low voltage (wash co) looks to be
1 -hr. rated min.
BUPC740 Framing Insp / / / / 09/14/98 See SHEAR & MISC. THIS DATE: PART GS 09/15/98 J *H
1ST FLOOR FRAMING APPROVED.
OK TO INSULATE.
BUPC740 Framing Insp 09/17/98 / / 09/16/98 2nd & 3rd floor framing: FAIL GS 09/17/98 J *H
1. Vent exhaust fan in stairways.
2. Reinforce ceiling joist room 226.
3. Fire caulk back to back electrical
boxes.
• 4. Firestop gray low voltage cables, top
plate room 218.
5. Flat stud room 219.
6. Vent bath fans room 211, 213.
7. Repair joist room 208.
Mechanical failed, soffets at rear of
building not ready.
•
Page No. 5 CASE HISTORY FOR CASE NO.: BUP97 -0514
BEST WESTERN
'16105 SW PACIFIC HWY
01/08/99
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
•
---- - -- ------ -- ---
BUPC740 Framing Insp 09/17/98 / / 09/18/98 3rd floo wall framing okay, roof framing PART GS 09/20/98 J *H
failed.
Several lateral bracing missed (marked
on truss details at job site).
BUPC740 Framing Insp / / / / 09/28/98 repair floor joists cut for plm FAIL GS 10/01/98 GES
BUPC740 Framing Insp / / / / 09/28/98 laterial bracing on roof trusses FAIL GS 10/01/98 GES
BUPC740 Framing Insp / / / / 09/29/98 excluding roof PASS GS 10/01/98 GES
BUPC740 Framing Insp / / / / 10/05/98 DROPED CEILING SUITE 224 PART GS 10/05/98 GES
BUPC740 Framing Insp / / / / 10/16/98 soffets in lobby and pool area pass PART GS 10/16/98 GES
BUPC742 Roof nailng Insp 11/17/97 / / 07/16/98 missed nailing thru -out • FAIL RB 07/16/98 RB
BUPC742 Roof nailng Insp / / / / 07 /30 /98.canopy only PASS RC 07/30/98 ROC
BUPC742 Roof nailng Insp / / /. / 07/30/98 lobby -pool not ready FAIL RC 07/30/98 ROC
BUPC742 Roof nailng Insp / / / / 07/20/98 Upper roof only (3rd story) PART RC 07/30/98 J *H
BUPC742 Roof nailng Insp 08/02/98 / / 07/31/98 Exterior gable ends approved. Roof over PART RC 08/02/98 J *H
pool & lobby nailing approved.
BUPC750 Insulation Insp 11/17/97 / / / / All exterior glass shall have a shading 09/22/98 J *H
coefficient of 0.57
BUPC750 Insulation Insp / / / / 09/22/98 Insulation on interior shear walls first PART GS. 09/22/98 J *H
floor: pass.
■ Insulation pool area interior walls: 1)
replace fallen insulation, 2) insulate
sides of skylights (fail), 3) vapor
barrier oh ceiling (fail).
BUPC750 Insulation Insp / / / / 09/28/98 all 3 floors PASS GS 10/01/98 GES
3
BUPC757 Shear Wall Insp 11/17/97 / / 07/01/98 exterior sheathing and interior PART TLP 07/08/98 TLP
sheathing and interior sheathing nailing
only no anchors approved
•
•
Page No. 6 CASE HISTORY FOR CASE NO.. BUP97 -0514
BEST WESTERN
16105 SW PACIFIC HWY
01/08/99
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
BUPC757 Shear Wall Insp / / / / 07/13/98 Not Ready !!!! FAIL RB 12/17/98 GES
Special Inspection Report required for
epoxy of HD's
SPEC FINAL INSP BY BRAUN I•NTERTEC REC
Fps 121798]
BUPC757 Shear Wall Insp / / / / 09/14/98 FRAMING APPROVED, FRAMING & EXT. SHEAR PART GS 09/15/98 J *H
NOTES:
1. Support bottom of stair jacks (leave
one gyp board off for inspection. •
2. Shaft for HW tanks not in '(needs to
be left off for now).
• SEE MISC. INSPECTION THIS DATE. •
BUPC757 Shear Wall Insp / / / / 09/28/98 PART GS 10/01/98 GES
BUPC757 Shear Wall Insp / /, / / 10/06/98 INTERIOR SHEAR COMPLETED ALSO, 1ST LAYER PASS GS 10/14/98 J *H
• CEILING IN LOBBY.
BUPC757, Shear Wall Insp / / / / 10/06/98 Ceilings in lobby, pass PASS GS 10/14/98 J *H
BUPC758 Firewall Insp / / / / 07/13/98 Gyperete prep- ok (PREP FOR SHOWERS) PART RB 07/13/98 RB
BUPC758 Firewall Insp / / / / 07/13/98 See gyp. inspection this date- prep PART RB 07/13/98 RB
only- no gyp installed yet.
Add studs where missed.
BUPC758 Firewall Insp / / / / 07/21/98 all exterior walls except soffitt and PASS RC 07/29/98 DGW
gable ends
BUPC758 Firewall Insp 08/02/98 / / 07/31/98 Exterior gable ends approved, roof over PASS RC 08/02/98 J *H
pool & lobby nailing.
BUPC758 Firewall Insp / / / / 08/25/98 1ST LAYER ON SOFFITT EXCEPT BACK FROM PASS RC 08/25/98 ROC
1.25 TO 15.75.
BUPC758 Firewall Insp / / / / 08/13/98 Soffits at exterior driveway area only PART RC 08/26/98 J *H
approved.
BUPC760 Gyp Board Insp 11/17/97 / / 08/04/98 Notching or boring in bearing walls FAIL RC 08/04/98. ) *H
cannot exceed 25% or 7 /Bths -inch in a 3
1/2 -inch stud. 40% in non - bearing
walls. All joints in firewall not on
framing members must be firecaulked.
•
Page No. 7 CASE HISTORY FOR CASE NO.: BUP97 -0514
BEST WESTERN •
16105 SW PACIFIC HWY
01/08/99
•
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
BUPC760 Gyp Board Insp / / / / 07/13/98 Prep work behind showers. PART RB 07/13/98 RB
Obtain plumbing approval at walls with
plumbing.
Insulate walls as needed; a given at
location of showers.
• BUPC760 Gyp Board Insp / / / / 07/28/98 exterior gyp.- called for gable ends- FAIL RB 07/28/98 RB
incompleted.
Interior shower compartments- remove
drywall on plumbing wall, as to view
stud supports for upper floors.
Plumbing cover already approved by TLP-
viewed card on site. •
All fasteners shall be rated for 1 -hr
wall. Also, provide adequate nailing as
per Code specs for attachment of gypsum.
Nails= 8" walls & 7" ceilings.
BUPC760 Gyp Board Insp / / / / 08/12/98 BOTH LAYERS ON SOFFITT ON 17 FROM B TO H PART RC 08/12/98 ROC
,ON H FROM17 TO 15.5, ON B FROM 17 TO
15.75
NOTE: BOTH SHEETROCK BROKE ON SAME
FRAMING MEMBER AT CORNER OF B & 15.75.
BUPC760 Gyp Board Insp / / / / 08/19/98 Need fireblock & insulation before FAIL RC 08/19/98 J *H
sheetrock.
BUPC760 Gyp Board Insp / / / / 08/20/98 Fireblocking not completed. FAIL RC 08/20/98 J *H
BUPC760 Gyp Board Insp / / / / 09/04/98 EXHAUST VENT SHAFTS: PART RB 09/04/98 RB
1015 am- first layer ok
1210 pm- second layer- missed- nailing at
8" oc- minimal.
SHOWER COMPARTMENTS:
• Nail drywall 8" oc at all perimeters /12"
oc in field.
BUPC760 Gyp Board Insp / / / / 09/22/98 Exterior gyp sheathing on rear soffets PART GS 09/22/98 J *H
(pass).
BUPC760 Gyp Board Insp / / / / 10/01/98 FIRST LAYER CEILING 3RD FL, EXCEPT CORR PART GS 10/01/98 GES
AND STAIRS
Page No. 8 CASE HISTORY FOR CASE NO.. BUP97 -0514
BEST WESTERN
16105 SW PACIFIC HWY
01/08/99
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent . Done Done Date By
BUPC760 Gyp Board Insp / / / / 10/05/98 FIRST LAYER 3rdFL CORR LID PART GS 10/05/98 GES
BUPC760 Gyp Board Insp / / / / 10/06/98 1st layer lobby lid PART GS 10/06/98 GES
BUPC760 Gyp Board Insp / / / / 10/08/98 first layer pool area lid PART GS 10/08/98 GES
BUPC760 Gyp Board Insp / / / / 10/09/98 FAIL canopy.lid not ready PART GS 10/09/98 GES
BUPC760 Gyp Board Insp / / / / 10/14/98 1. 2nd floor walls approved. PART RC 10/15/98 J *H
2. 3rd floor walls & ceiling except
• stair & storage room lids placed
parralell to framing members. Either
block and rescrew or replace
perpendicular.
3. 2nd floor lid in storage room
parralell to frame members.
BUPC760 Gyp Board Insp / /. / / 10/12/98 1st layer ® canopy PASS GS 10/15/98 J *H
BUPC760 Gyp Board Insp / / / / 10/21/98 walls and first layer cell in lobby and PASS GS 10/21/98 GES
pool rms
BUPC760 Gyp Board Insp / / / / 10/22/98 1st fl gypbd pass PART GS 10/23/98 GES
BUPC762 Susp Ceilng Insp 11/17/97 / / 12/01/98 1ST AND 2ND FL CORRIDORS PART GS 12/01/98 GES
obtain listed assembly for use at
bundled cables penetrating firewalls
slack wires for recessed can lights •
OK TO COVER EXCEPT AT ABOVE LOCATIONS
BUPC762 Susp Ceilng Insp / / / / 12/03/98 1st and 2nd fl pass except at cable PART GS 12/03/98 GES
penetrations in firewall
BUPC763 Reinforced concrete final rept 11/17/97 / / 12/17/98 REC GS 12/17/98 GES
BUPC771 Fire - proofing final.report / / / / 07/13/98 Fire protection appears to be adequate PART RB 07/13/98 RB
with minor bare spots... Submit Final
Fire - Proofing Report from Special
Inspector.
BUPC786 Smoke detector insp 11/17/97 / / / / 11/17/97 RDP
BUPC790 Appr /sdwlk Insp 11/17/97 / / / / N/A 07/28/98 RB
BUPC792 Misc. Inspection 11/17/97 / / 07/13/98 Engineering keystone wall w/ CMU block PART RB 07/13/98 RB
wall installed above. Greater than
4 -feet. PERMIT REQUIRED- Free - standing
w/ no retaining.
Maintain 2' footing and rebar req'mts.
Page No. 9 CASE HISTORY FOR CASE NO.: BUP97 -0514
• BEST WESTERN
16105 SW PACIFIC HWY
01/08/99
Action Description Reg/ Schd/ End/ 'Action Notes Disp By Update Upd
Code Sent Done Done Date By
BUPC792 Misc. Inspection / / / / 07/23/98 FOOTING FOR MASONRY SOUND WALL APP. PASS RC 07/23/98 ROC
NEED GEOGRID INSP. BEFORE PAVING.
BUPC792 Misc. Inspection / / / / 07/28/98 Revise plans as per height of wall at N. PART RB 07/28/98 RB
corner- in excess of 20 -feet for
approximately 27 -feet each wall.
Plans note 11 -feet w/ 5 -feet max at
lower level w/ 6 -feet upper level, and
10" off -set between walls.
Contour lines identify 8 -feet from top
of wall to base of wall. Existing
20 -feet
BUPC792 Misc. Inspec ;ion / / / / 08/28/98 2ND LAYER ON2ND FLOOR SOFFITT EXCEPT PASS RC 08/28/98 ROC
BACKOF BLDG FROM 1.25 - 15.75
BUPC792 Misc. Inspection / / / / 08/28/98 ELEVATOR SHAFT FRAMING FAIL RC 08/28/98 ROC
1. PLACE STUDS WHERE CUT FOR PLUMBING
2. STRAP WALLS WHERE CUT FOR PLUMBING.
3. FIREBLOCK PLUMBING, WIRES, HOLES AND
CRACKS AT EACH FLOOR /CEILING AND WALL
PENETRATIONS
BUPC792 Misc. Inspection / / / / 09/15/98 PART GS 09/15/98 J *H
BUPC792 Misc. Inspection / / / / 09/14/98 1. Renail lid 2 places (marked). PART GS 09/15/98 J *H
2. Public bathroom vent shaft not ready.
BUPC792 Misc. Inspection / / / / 09/24/98 construction change of vent fan chases, PASS GS 09/24/98 GES
see letter and drawing in file from
Chris Baker [USG], stamped by Jim Harris
•
arch.
BUPC792 Misc. Inspection / / / / 10/01/98 RC CHANNEL 2ND FL WALLS AND CEILING PART GS 10/01/98 GES
RC CHANNEL 1ST FL CEILINGS PASS.
BUPC792 Misc. Inspection ' / / / / 10/01/98 DRAFT STOP COVERINGS IN ATTIC PASS PASS GS 10/01/98 GES
BUPC792 Misc. Inspection /. / / / 11/03/98 draft stop in soffets in motel laundry PASS GS 11/04/98 GES
•
•
Page No. 10 CASE HISTORY FOR CASE NO.: BUP97 -0514
BEST WESTERN
16105 SW PACIFIC HWY
01/08/99
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done • Date By
BUPC792 Misc. Inspection / / / / 12/16/98 Received Special Inspection Report (not NOTE JH 12/23/98 J *H
marked as final summary and showing
wrong address). Report from Braun
Intertec shows work in accordance with
plans for
Concrete and Reinforcing and Epoxy
Anchors. Routed to file 122398/jh
BUPC802 Final Inspection 11/17/97 / / / / No final or occupancy permit without 10/14/98 J *H
approval by King City Manager. The
applicant has chosen to pay their TIF
fee prior to final. Please require
written authorization from King City
BUPC802 Final Inspection / / / / 01/06/99 PART (1ST FL AND SITE; address, FAIL GS 01/06/99 GES
HCparking as discussed, final summary
letters, glass at pool does not meet
shadding coe of .57 submit energy calks
for tradeoff, retest of some strobes,
adjust closures rms. 100, 107, mens
bthrm, laundry shute, double doors need
astric and possibly coordinaters, max
space beneth doors; single 3/8 ", double
1/4 ", HC signagemaids bth door, make
•
guests laundry sink accessable, need
cleanout and seal around pipe at wall in
contintal brfks kitchen
BUPC802 Final Inspection / / / / 01/07/99 PART 2nd and 3rd fls; adjust closures FAIL GS 01/07/99 GES
doors 324, 318, 204, 234
seats for HC tubs
laundry shuts access doors are listed
for horiz assembly, provide
documentation approving vertical
application also spring closures req.
BUPC802 Final Inspection / / / / 01/08/99 bld final approved pending final PASS GS 01/08/99 JT
approval from king city
1/8/99 King City approval letter
received. Jeanne T.
BUPC950 (F) Issue Cert. of Occupancy / / / / 01/08/99 01/08/99 JT
CITY OF TIGARD BUILDING INSPECTION DIVISION
MST
24 -Hour Inspection Line: 639 -4175 - L Business Line: 639 -4171 7 U 5.`
UP
Date Requested ( ? Vt. l AM PM "B4, 7 8, (> t_ L 5
Location I (� ( S- i Suite MEC 7 - a y3 6
Contact Person Ph r I OD-42 2 Q •PeiVF 9 g'- n l 7 7
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT 9 7- cape, Y
Post & Beam
Ext Sheath /Shear
Int Sheath/Shear
Framing
Insulation • Drywall Nailing �
Firewall - / 1 • _ /
Fire Sprinkler .
Fire Alarm
Susp'd Ceiling , �.�i� : �.�
Roof (�
Misc:
S � - _ e . .�� _• _Or — -a . - i
'PLUMBING /
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART., FAIL ECHANIC
Post & Beam
Rough In
Gas Line
Smo e Dampers
Ji • PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
A� PART FAIL
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk Date / — `� / c�
Inspector Ext
Other
ASS PART FAIL DO NOT REMOVE this inspection record from the job site.