Permit CITY OF TIGARD MECHANICAL PERMIT ,-: ,A.g) 1 1 1 1 DEVELOPMENT SERVICES IT• ME -0436 41 13125 SW Hall Blvd., Tigard, OR 97223 (503)639-4171 DATE S SUED: 03/25/98 PARCEL: 2S115BA -00600 SITE ADDRESS...: 16105 SW PACIFIC HWY SUBDIVISION • ZONING: BLOCK • LOT • JURISDICTION: KIN CLASS OF WORK..:NEW FLOOR FURN : 0 EVAP COOLERS: 0 TYPE OF USE •COM UNIT HEATERS..: 0 VENT FANS...:77 OCCUPANCY GRP..:R1 VENTS W/0 APPL: 5 VENT SYSTEMS: 0 STORIES • 3 BOILERS /COMPRESSORS HOODS : 0 FUEL TYPES 0 -3 HP • 2 DOMES. INCIN: 0 :GAS 3 -15 HP - 0 COMML. INCIN: 0 MAX INPUT: 1500000 BTU 15 -30 HP • 0 REPAIR UNITS: 0 FIRE DAMPERS ?..: Y 30 -50 HP • 0 WOODSTOVES..: 0 GAS PRESSURE...: M 50+ HP • 0 CLO DRYERS..: 4 NO. OF UNITS AIR HANDLING UNITS OTHER UNITS.: 4 FURN < 1O0K BTU: 2 <= 10000 cfm: 2 GAS OUTLETS.: 1 FURN > =1O0K BTU: 1 > 10000 cfm: 0 Remarks : New construction of a 73 unit motel - This permit does not include the pool area heater and ancilliary requiresents. Owner: FEES KCM ASSOCIATES LLC type amount by date recpt 10895 SW FIFTH PRMT $ 334.50 B 03 /25/98 98- 304393 BEAVERTON OR 97005 PLCK $ 83.63 B 03/25/98 98- 304393 5PCT $ 16.73 B 03/25/98 98- 304393 Phone #: Contract or: LARRYS HEATING LARRY E SOUTHARD 4818 NW 139TH LOOP $ 434.86 TOTAL VANCOUVER OR 98685 Phone #: 360- 574 -9334 Reg #..: 63575 REQUIRED INSPECTIONS This permit is issued subject to the regulations contained in the Gas Line Insp Tigard Municipal Code, State of Ore. Specialty Codes and all other Mechanical Insp applicable laws. All work will be done in accordance with Heating Unt Insp approved plans. This peruit will expire if work is not started Shaft Inspection within 180 days of issuance, or if work is suspended for sore Duct Inspect ion than 180 days. ATTENTION: Oregon law requires you to follow rules Fire Damper Insp adopted by the Oregon Utility Notification Center. Those rules are S. D. Shut —down set forth in OAR 952- 001 -0010 through OAR 952 -001 -0080. You way Misc. I n s p e ct i o n obtain copies of these rules or direct questions to OUNC by calling Final Inspection (503)246 -9187. Issue By: Permittee Signature: i, /�.I /jt�/ ++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ Call 639 -4175 by 7:00 p.m. for inspections needed the next business day ++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ I 77 7 Plan Che - CITY OF TIGARD Mechanical Permit Application Recd B a I , 13125 SW HALL BLVD. Commercial and Residential Date Recd 1 - 3 - , - TIGARD, OR 97223 Date to P.E. - - -"1 (503) 639 -4171, x304 Date to DST Z Print or Type Permit # U. J'_' I J • Called -Ytb l - Ili. Incomplete or illegible applications will not be accepted f „ Name of Development/Project Description Best Western Table 1A Mechanical Code OT( PRICE AMT Job Street Address Suites A) Permit Fee -0- -0- 10.00 Address 16105 SW Pacific Hwy Bldg# Oih'gSta;q y d 97224 1.) Furn t 100 BTU 6.00 King l; 2 12.00 including ducts & vents Name (or name of business) 2.) Furnace 100,000 BTU+ 7.50 Owner KCM Associates LLC including ducts & vents 1 7.50 • Mailing Address 3.) Floor Furnace 6.00 10895 SW Fifth including vent cityrstate Z - Phone 4.) Suspended heater, wall heater 6.00 Beaverton, OR 97005 643 -5421 or floor mounted heater Name (or name of business) 5.) Vent not included in appliance permit 3.00 Same as Owner 5 15.00 Occupant Mailing Address 6.) Boiler or comp, heat pump, air cond. 2 6.00 12.00 • to 3 HP; absorb unit to 100K BUT" Cityistate Zip Phone 7.) Boiler or comp, heat pump, air cond. 11.00 3-15 HP: absorb unit to 500K BTU" Contractor Name r 8.) Boiler or comp, heat pump, air cond. 15.00 (Prior to Larry's Heating -OA S i k t 15-30 HP: absorb unit5-1 mil BTU" issuance Mailing Address 9.) Boiler or comp, heat pump, air cond. 22.50 applicant 14116 NW 29th Court 30-50 HP; absorb unit 1- 1.75mil BTU" • must provide all gttyiStats Zip Phone 360 10.) Boiler or camp, heat pump, air cond. 37.50 contractor ancouver, , WA 98685 574 -9334 > 50 HP; absorb unit 1.75 mil BTU" license Oregon Const Cont Board Licit Exp. Date 11.) Air handling unit to 10,000 CFM 2 4.50 • 9.00 information 63575 for COT COT Business Tax or Metro it Exp oats 12.) Air handling unit 10,000 CFM 7.50 database). 702 K.C. 6/30/98 Architect Name 13.) Non - portable evaporate cooler 4.50 Charles C. Hagel Or Mailing Address 14.) Vent fan connected to a single duct 3.00 11580 SW 67th . • 77 231.00 Engineer Cayrslate Zip Phone 15.) Ventilation system not included in 4.50 Tigard, OR 97224 620 -3825 appliance permit Describe work NewX Addition 0 Alteration 0 Repair 0 16.) Hood served by mechanical exhaust 4.50 to be done Residential 0 Non - residential 0 Additional Description of work 17.) Domestic incinerators 7.50 New Construction - 73 Unit Motel 18.) Commercial or industrial type 30.00 • Incinerator • Existing use of 19.) Repair units 4.50 building or property Vacent Lot 20.) Wood stove 4.50 Proposed use of 73 Unit Motel 21.) Clothes dryer, etc. 4.50 building or property . 22.) Other units 4,50 Type of fuel - oil 0 natural gas 0 LPG 0 electric 0 23.) Gas piping one to four outlets 2.00 I hereby acknowledge that I have read this application, that the 24.) More than 4 -per outlets (each) .50 information given is correct, that I am the owner or authorized agent of the owner, that plans submitted are in compliance with Oregon State . SUBTOTAL / laws. 89 Signature of Owner /Agent Date 'SUBTOTAL �� VI P.'6 50 Andrew A. I1 g g344-*QA07 5 %SURCHARGE / 1 Contact Person Name Phone PLAN REVIEW 25% OF SUBTOTAL 113 7 .13 I TOTAL 1 4N.41038 ', . 4 .6 insist' echpmt.doc (rev 9 'Minimum permit fee is 525 + 5% surcharge "Residential NC requires site plan showing placement of unit • Page No. 1 CASE HISTORY FOR CASE NO.: MEC97 -0436 BEST WESTERN • 16105 SW PACIFIC HWY • 01/08/99 Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By • • MECC007 Application received / / / / 11/03/97 RECD DRA 11/05/97 BON MECC008 Permit created / / / / 11/05/97 DONE B 11/05/97 BON MECC011 Routed to Plans Examiner / / / / 11/05/97 SENT B 11/05/97 BON MECCO15 Reviewed Plans Routed to DSTS / / / / 02/11/98 APPR RDP 02/11/98 RDP MECC016 DST Post - Review Completed / / / / 02/11/98 DONE B 02/11/98 BON MECC016 DST Post- Review Completed / / / / 03/24/98 DONE B 03/24/98 BON MECCO20 HOLD FOR / / / / 02/11/98 This permit can only be issued in HOLD RDP 03/24/98 BON conjunction with the building permit. ?s see Bob P MECCO50 (F) Ready to issue / / / / 03/24/98 Rosie at City of King City okayed PASS B 03/24/98 BON release of permits. Contractor not in our database. MECC090 (F) Issue permit / / / / 03/25/98 PASS B 03/25/98 CTR MECC705 Gas Line Insp 02/11/98 / / 07/08/98 Line to 2 water heaters, 3 dryers, pool PASS RC 07/22/98 J *H heater and 1 roof unit. (Note: Permit specfifies that pool • heater is not included.) MECC706 Mechanical Insp 02/11/98 / / 09/16/98 not ready FAIL GS 09/17/98 J *H MECC725 Heating Unt Insp 02/11/98 / / 01/05/99 PASS GS 01/05/99 GES MECC731 Shaft Inspection 02/11/98 / / / / done w/ frame and gyp insps 01/05/99 GES MECC735 Duct Inspection 02/11/98 / / / / duct inspections were done at the same PASS GS 12/30/98 GES • time as wall and ceiling framing • inspections were done and passed in stages as work progressed • MECC740 Fire Damper Insp 02/11/98 / / 12/30/98 N/A GS 12/30/98 GES MECC745 S.D. Shut -down 02/11/98 / / / / 02/11/98 RDP MECC750 Misc. Inspection 02/11/98 / / 01/04/99 canceled per jt by pager FAIL GS 01/04/99 GES MECC799 Final Inspection 02/11/98 . / / 01/05/99 1.HVAC above pool;cond drain, support FAIL GS 01/05/99 GES • gas pipe at elbow, need to test sd shutdown if over 2000 cfm • 2.exter generator;mech protection, shutoff valve within 3' of equipt, drip leg, pipe support, 3.support gas pipe at wtr htrs MECC799 Final Inspection / / • / / 01/08/99 PASS GS 01/08/99 GES MECC800 Case Finaled / / / / 01/08/99 01/08/99 JT • • CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 - L Business Line: 6394171 ll UP ' 7C Date Requested g L�, AM PM 7'g - b L G 5 Location l (o /0 S Suite Q MEC } 7--e, 4 /3 Contact Person Ph '7 c eD_ gyp - 9 T- n l 7 7 Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT 97— � / Post & Beam Ext Sheath /Shear Int Sheath/Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler . / - Fire Alarm Susp'd Ceiling Roof / Misc: aga PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART_ FAIL MECHANIC Post & Beam Rough In Gas Line Smo e Dampers Ji PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASk PART FAIL IC Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date Other / ` Inspector Ext PART FAIL DO NOT REMOVE this inspection record from the job site.