Permit CITY OF TIGARD MASTER PERMIT l • • - COMMUNITY DEVELOPMENT Permit #: MST2012 -00096 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 05/22/2012 Parcel: 2S109DA15500 Jurisdiction: Tigard Site address: 15298 SW GREENRIDGE PL • Subdivision: ARLINGTON HEIGHTS NO.3 Lot: 74 Project: Arlington Heights No. 3, lot 74 Project Description: Installation of solar photovoltaic system BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $0.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Tubs /Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell- Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum <100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum > =100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 0 0 -200 amp: 0 0-200 amp: 0 W/ Svc or Fdr: 0 Ea addl 500 sf: 0 201 -400 amp: 0 201 -400 amp: 0 W/O Svc/Fdr: 0 Mfd Home /Feeder /Svc: 0 401 -600 amp: 0 401 -600 amp: 0 601 -1000 amp: 0 601 +amp- 1000v: 0 1000 +amp /volt: 0 ELECTRICAL - RESTRICTED ENERGY SF Residential Audio 8 Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R -3 0 Owner: Contractor: STONE BRIDGE HOMES LIVELIGHT ENERGY LLC Required Items and Reports (Conditions) 4230 GALE WOOD ST, STE 100 1750 SW 187TH AVE LAKE OSWEGO, OR 97035 BEAVERTON, OR 97006 PHONE: 503- 387 -7577 PHONE: 503- 690 -4402 FAX: 503- 690 -4399 Total Fees: $205.60 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issu. • or if work is suspended for more the 180 days. A - • _ : •regon law requires you to follow the rules adopted by the Oregon Utility Notificati• ' . r. Those rules are set forth in OAR I 952 -0• -0010 through O - 952 -00 -0090. You may obtain a copy of the rules or direct questions to OUNC by calling 50 , :' • 1.800.332.2344. ' Iss =d By: 'i �� Permittee Signature: ,.1 Call 503.639.4175 by 7:00 a.m. for the next available Inspecti o ate. This permit card shall be kept In a conspicuous place on the job site until completion of the project Approved plans are required on the job site at the time of each Inspection. Building Permit Application Y i r , Residential , i �4.3 FoR 01. FIti.. tick ' ON'1.1 City Tigard Rece of Ti and ,J Permit No.: H , , /a- 6 � p , Date /B : S • _ 13125 SW Hall Blvd., Tigard, OR 97223 MAY — g plan Revie ' C Phone: 503.718.2439 Fax: 503.598.1960 Date/B : , �IM �llin Other Permit: Inspection Line: 503.639.4175 �, Date Ready /B : la See Page 2 for Internet: www.tigard- or.gov CITY Notified/Method /2 1►J Supplemental Information RFJiLD1NC D : 0 /-1 Al/91# TYPE OF WORK REQUIRED DATA: 1- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ® Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ® 1- and 2- family dwelling ❑ Commercial/industrial Valuation: $2000 ❑ Accessory building ❑ Multi - family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 15298 SW Greenridge Place New dwelling area: square feet City/ State/ZIP: Tigard OR 97223 Garage/carport area: square feet Suite/bldg. /apt. no.: Project name: 10916 Stonebridge Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. 2.040 kW Solar PV installation Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER I ❑ TENANT Number of stories: Name: Jim Delmore Type of construction: Address: 4230 Galewood St. #100 Occupancy groups: City/State/ZIP: Lake Oswego OR 97035 Existing: Phone: ( ) Fax: ( ) New: 0 APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* Business name: LiveLight Energy (Please refer to fee schedule) Structural plan review fee (or deposit): Contact name: Molly Wadley FLS plan review fee (if applicable): Address: 1815 NW 169 Place ste 4020 City/ State/ZIP: Beaverton OR 97006 Total fees due upon application: Phone: (503) 690 -4366 I Fax: : (503) 690 -4399 Amount received: E -mail: molly @livelightenergy.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof -top mounted Photo Voltaic Solar Panel System. Business name: LiveLight Energy Submit two (2) sets of roof plan with connection details and fire department access, along with the 2010 Oregon Address: 1815 NW 169th Place ste 4020 Solar Installation Specialty Code checklist. City/State/ZIP: Beaverton OR 97006 Permit Fee (includes plan review $180.00 and administrative fees): Phone: (503) 690 -4366 Fax: (503) 6904399 State surcharge (12% of permit fee): $21.60 CCB lie.: 187491 Total fee due upon application: $201.60 Authorized signature: I1 I ` ' This permit application expires if a permit is not obtained ,'' • ,I within 180 days after it has been accepted as complete. Print name: Matthew Hall I Date: 5 -8-12 * Fee methodology set by Tri- County Building Industry Service Board. I:\Building\Permits\BUP- RESPermitApp.doc 02/24/2011 440 -4613T(I 1/02 /COM/WEB) Building Permit Application Checklist One- and Two -Family Dwelling FOR orFice: USE ONLY Received City of Tigard Date/By: Received Permit No.: Up/ u 1 3125 SW Hall Blvd., Tigard, OR 97223 Associated permits: C Phone: 503.718.2439 Fax: 503.598.1960 24- Hour Inspection Line: 503.639.4175 0 Electrical 0 Plumbing 0 Mechanical T l G A I: D Internet: www.tigard- or.gov ❑ Other: TI -IE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Y'e's No N/A 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ 2 Zoning. Flood plain, solar balance points, seismic soils designation, historic district, etc. ❑ ❑ El 3 Verification of approved plat/lot. El ❑ 4 Fire district approval required. Name of district: . ❑ ❑ El 5 Septic system permit or authorization for remodel. Existing system capacity . ❑ ❑ El 6 Sewer permit. El ❑ El 7 Water district approval. ❑ ❑ IZI 8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ ❑ El 9 Erosion control ❑ plan ❑ permit required. Include drainage -way protection, silt fence design and location of catch- ❑ ❑ El basin protection, etc. 10 3 Complete sets of legible plans. Must be drawn to scale, showing conformance to applicable local and state ® ❑ ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full -size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. I I Site/plot plan drawn to scale. The plan must show lot and building setback dimensions; property corner elevations (if ® ❑ ❑ there is more than a 4 -ft. elevation differential, plan must show contour lines at 2 -ft. intervals); location of easements and driveway; footprint of structure (including decks); location of wells /septic systems; utility locations; direction indicator; lot area; building coverage area; percentage of coverage; impervious area; existing structures on site; and surface drainage. 12 Foundation plan. Show dimensions, anchor bolts, any hold -downs and reinforcing pads, connection details, vent size ® ❑ ❑ and location. 13 Floor plans. Show all dimensions, room identification, window size, location of smoke detectors, water heater, ❑ ❑ furnace, ventilation fans, plumbing fixtures, balconies and decks 30 inches above grade, etc. 14 Cross section(s) and details. Show all framing- member sizes and spacing such as floor beams, headers, joists, sub- ❑ ❑ floor, wall construction, roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing, roofing, roof slope, ceiling height, siding material, footings and foundation, stairs, fireplace construction, thermal insulation, etc. 15 Elevation views. Provide elevations for new construction; minimum of two elevations for additions and remodels. ❑ El Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full -size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing (prescriptive path) and/or lateral analysis plans. Must indicate details and locations; for non El ❑ prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor /roof framing. Provide plans for all floors/roof assemblies, indicating member sizing, spacing, and bearing El ❑ locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ systems, see item 22, "Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ over 10 feet long and/or any beam/joist carrying a non - uniform load. 20 Manufactured floor /roof truss design details. ❑ ❑ El 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas- piping schematic is required ❑ ❑ for four or more appliances. 22 Engineer's calculations. When required or provided, (i.e., shear wall, roof truss) shall be stamped by an engineer or ❑ ❑ architect licensed in Ore:on and shall be shown to be ap plicable to the . ro'ect under review. JURISDICTIONAL SPECIFICS 23 Three (3) site plans are required for Item 11 above. Site plans must be 8 -1/2" x 11" or 11" x 17 ". 0 ❑ ❑ 24 Two (2) sets each are required for Items 16, 19, 20 and 22 above. ❑ ❑ 25 Building plans shall not contain red lines or tape -ons. "Mirrored" building plans will not be accepted. ® ❑ ❑ 26 "Reversed" building plans must meet criteria outlined in the Permit & System Development Fees document. 0 ❑ ❑ 27 "Drawn to scale" indicates standard architect or engineer scale. ® ❑ El 28 Site plan to include tree size, type and location per approved project street tree plan (if applicable), and City of Tigard ❑ ❑ Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations, driplines, ❑ ❑ and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services' Sensitive Area Pre - Screening Site Assessment form is required for all building additions, ❑ ❑ El including decks, patio covers (over non - impervious surface) and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. 1:\Building\Permits\BUP- RESPermitApp.doc 02/24/2011 440 -4613T(I 1/02 /COM/WEB) City of Tigard Building Division ' - 13125 SW Hall Blvd, Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 TI GARD Inspection Line: 503.639.4175 www.tigard - or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof - Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 7 2 ('ru -tomr /44._ City: % ri b ()j Zip:1/ zL Z Owner's Name: joi,\ Pd Date: G _ _Tv__ Contractor's Name: (iv -ll,4 6j7 CCB #: 41((9) Design Parameters of the Property /Structure If "Yes ", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? E' loo OSSC or ORSC for design requirements. Is the wind exposure �es If "Yes ", qualifies for Wind Exposure "C" or less? ❑ N the prescriptive path. Installations on detached Is the Ground Snow single /two - family Load 70 psf or less? dwelling/single /two- If "Yes ", qualifies for family townhomes [OX'es the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf r less? structures other than If "Yes ", qualifies for Yes the prescriptive path. above ❑ No I: /Building/ Forms /PhotoVoltaic- Checklist.docx Is the construction Type of material wood and doe Yes If "Yes ", qualifies for the construction qualify Construction ❑ No the prescriptive path. as "conventional light frame" construction? Is the spacing 24 inches or less? Pre - engineered trusses. []Yes If "Yes ", qualifies for the rescri tive path. P P P ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. vs If "Yes ", qualifies for the prescriptive path. ❑ No Is the combined weight Er Yes of the PV modules and If "Yes ", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes If "Yes ", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Ingle layer If roofing material is Roofing Check the type of of wood one of the three types material roofing material shingle /shake checked, qualifies for Mix. two layers the prescriptive path. [ omposition shingle. Is the roof mounted El /Yes es Connections of solar assembly the solar assembly connected to roof If "Yes", qualifies for framing or blockin ❑ No the prescriptive path. to the roof g g directly? 2 I: /Building/ Forms /Photovoltaic- Checklist.docx ❑ Yes If "Yes ", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If "Yes ", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? . If "Yes ", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel is less than 18 inches, . nanels? 18 inches or less qualifies for the inches prescriptive path. Minimum #10 at 24 inches o /c? Size and spacing of If "Yes ", qualifies for • fastener? El Yes the prescriptive path. ❑ No is the roof decking of WSP min. '' /2" thickness, ❑ Yes decking connected to If "Yes ", qualifies for framing members ❑ No the prescriptive path. w /min. 8d nails @ 6"/12" o /c? • Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the r , / If "Yes ", qualifies for solar modules module to the roof L1� Yes the prescriptive path. surface. ❑ No 3 I: /Building/ Forms /PhotoVoltaic - Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: 46-V (p)pf /6 1 Model Number: 4 ivt ,, 4 Listing Agency: 4 I: /Building/ Forms /PhotoVoltaic - Checklist.docx