March 7, 2005 •
T0507521. CTI
Permit No. 2002 -00369
FIELD INSPECTION REPORT
DATES COVERED: February 17, 2005
PROJECT: Toivo J Sepp Dental Office
ADDRESS: 16035 Pacific Highway — King City, OR
INSPECTOR: A. Ewing — COP#499, WABO #EWI629423, OBOA #169, ICBO#1060671 -88, -85
02- 17 -05: As requested, CTI representative was on site to inspect installation of epoxy . for
various holddowns. Epoxy specified was Simpson SET, but the epoxy provided was Unitex
Pro -Poxy 300 Fast (A/B) covered by ICBO ES -5000. Per phone conversation with structural
engineer, Tim Covert, this may be a problem with respect to critical minimum edge distances
and allowable values for tension. Contractor can send product info to engineer for review or get
this specific epoxy.
Also, some holes need to be drilled deeper and longer rods provided on the main floor.
"' CHECK ONE BOX ONLY "' YES NO
1. This is a preliminary inspection only. — OR —
2. The work inspected conforms to acceptance criteria listed above. If "No," the portions of the
work that are non - conforming items are clearly stated above and will be added to the NCL.
Remaining portions of the work, which are not preliminary in nature, are to be considered as ❑ ❑
conforming.
Our reports pertain to the material tested /inspected only. Information contained herein is not to
be reproduced, except in full, without prior authorization from this office.
If there are any further questions regarding this matter, please do not hesitate to contact this
office.
Respectfull submitted,
CARLS t TESTING, INC.
-s F. Hietpas
O • ,, rations Manager •
• /sab
cc: Toivo J Sepp '
City of Tigard Building Dept — Gary Lampella
Tim Covert PE