Loading...
SGN2012-00077 1111 CITY OF TIGARD SIGN PERMIT 16 Permit #: SGN2012 -00077 COMMUNITY DEVELOPMENT Date Issued: 05/11/2012 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2421 Parcel: 1S135AB01003 Jurisdiction: Tigard Name of Business: Red Lobster Business Address: 10330 SW GREENBURG RD Applicant/Agent: Robbins, Ty Work Description: Wall sign - Lobster Permanent: Yes Freestanding: No Freeway: No Temporary: Wall: Yes Electronic: No Billboard: No Balloon: No Banner: No A- Board: No Sign Dimensions: 3'4 "x7'2" Total Sign Area: 23.89 Wall Area: 2709 Wall Face (Direction): Sign Height: 17 ft. Projection From Wall: 4 in. Illumination: Internal Materials: Aluminum /acrylic Electrical Permit Required: Yes Building Permit Required: Total Permit Fee: $165.00 Conditions: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon sign shall expire 10 days from validity date. Approved By: "V 1 Permittee Signature: L�C{f1�1 CITY OF TIGARD RECEIPT 111 'V 1 l l 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 TIGARD Receipt Number: 186694 - 05/11/2012 CASE NO. FEE DESCRIPTION REVENUE ACCOUNT NUMBER PAID SGN2012 -00077 Sign Permit 100 - 0000 -43115 $144.00 SGN2012 -00077 Sign Permit - LRP 100 - 0000 -43117 $21.00 Total: $165.00 PAYMENT METHOD CHECK # CC AUTH. CODE ACCT ID CASHIER ID RECEIPT DATE RECEIPT AMT Check 279631 HWATKINS 05/11/2012 $165.00 Payor: North American Signs, Inc Total Payments: $165.00 Balance Due: $0.00 Page 1 of 1 IN City of Tigard . . Sign Permit Application TIGARD ... .. ..:i.•rz+,m.. _.wz 3 't t•, v r• 4�,. s ....4r< ...awe Y'.i GENERAL INFORMATION Name of Development /Project Site Red Lobster FOR STAFF USE ONLY / N Do a -- x'700 7 7 Address Street Address Permit No.: Location 10330 SW Greenburg Rd Suite /Bldg. # City/State Zip Approved By: . Tigard, OR 97223 Date: 9/ ii ii-- Name Receipt #: / b le b 9 L i- Knickerbocker Properties, Inc. Map /TL #: i- j'r 5 1/1 0t Property � ��� I Owner Mailing Address Suite Zoning. 235 Montgomery St 16th Floor Allowable Total Area: 1 1 /� City/State Zip Phone San Francisco, CA 94104 503- 412 -4800 Tenant or Name Electrical Permit Required? 'Yes ❑ No Business Red Lobster Building Permit Required? ❑ Yes ©�No Name Rev. 7/1/11 Vancouver Sign Group is \curpin \ masters \land use applications \ sign permit app.doc Sign Contractor Mailing Address Suite 2600 NE Andresen Rd 50 City/State Zip Phone REQUIRED SUBMITTAL ELEMENTS Vancouver, WA 98661 360 - 693 -4773 (Note: applications will Jun be accepted Oregon Const. Cont. Board License # Exp. Date without the required submittal elements) 63951 01 / 2 4 / 2 014 ❑ Completed Application Form Proposed g Permanent ❑ Freestanding ❑ Freeway ❑ 2 copies of site /plot plan, drawn to scale Sign ❑ Temporary ❑ Roof ❑ Electronic (Check all that (3 copies, if a building permit is required) © apply) Wall ❑ Other size requirement: 81/2" x 11 ", or 11" x 17" ❑ 2 copies of elevations, drawn to scale El New sign? ❑ Alter to existing sign? (3 copies, if a building permit is required) Sign Dimensions: 3 ' - 4 u x 7 1_2 tt size requirement: 81/2" x 11", to 24" x 36" Total Sign Area (sq. ft.): 23.89 ❑ $165.00 Fee (Permanent sign, any size) Si Data Total Wall Area (sq. ft.) . 88 a n ❑ $52.00 Fee (Temporary sign, any type) g" 2709 (Complete all Direction Wall Faces (circle one): items in this NOTES: section) N © E W NE NW SE SW Height to top of sign (feet): 1 9 I - 6 » • Wall signs do not need to be drawn to scale, but Projection From Wall (inches): 4 tt must include dimensions of wall face and sign Materials: placement. aluminum/acrylic • Wall signs do not require site /plot plans. Will sign have illumination? g Yes ❑ No ♦ Freestanding signs over 6 ft. required a building Type: © Internal ❑ External permit. Are there any existing freestanding or wall signs at this location, including wall signs that overlap a tenant space? ©Yes El No 4 If "yes ", a list or diagram of all sign dimensions and square (OVER FOR SIGNATURES) footage must also be submitted. see sign packet for this info City of Tigard I 13125 SW Hall Blvd., Tigard, OR 97223 I 503- 718 -2421 I www.tigard - or.gov I Page 1 of 2 APPLICANTS: To consider an application complete, you will need to submit ALL of the REQUIRED SUBMITTAL ELEMENTS as described on the front of this application in the "Requited Submittal Elements" box. NOTE: Person specified as "Applicant" shall be designated "Permittee" and shall provide financial assurance for work. * When the owner and the applicant are different people, the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s) must sign this application in the space provided on the back of this form or submit a written authorization with this application BY SIGNING BELOW, THE APPLICANT(S) SHALL CERTIFY THAT: ♦ If the application is granted, the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. ♦ All of the above statements and the statements in the plot plan, attachments, and exhibits transmitted herewith, are true, and the applicants so acknowledge that any permit issued, based on this application, and may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application, including the policies and criteria, and understands the requirements for approving and denying the application. I hereby acknowledge that I have read this application, that the information given is correct, that I am the owner or authorized agent of the owner, and that plans submitted are in compliance with the City of Tigard. SIGNATURES of each owner of the subject property are required. Y , 2 7_ /4 licant Signature Date Signature of Owner /Agent Date Ty Robbins 574 - 232 - 4474 Contact Person Name Phone No. City of Tigard I 13125 SW Hall Blvd., Tigard, OR 97223 I 503- 639 -4171 I www.tigard- or.gov I Page 2 of 2 '� RECEIVED SITE ENHANCEMENT SERVICES, INC. MAY 1 1 2012 CITY OF TIGARD PLANNING /ENGINEERING We, Darden Restaurants (GMRI, Inc.), hereby authorize Site Enhancement Services, acting as agent for Darden Restaurants (GMRI, Inc.), to proceed with the sign permit request for Red Lobster located at 10330 SW Greenburg Rd., Tigard, OR 97223. We have reviewed the proposed sign changes and authorize Site Enhancement Services to move forward with the sign permit process and any /all issues regarding signage. Corporate Representative's Name: Randy Calvanelli Representative's Signature: . C Company Name: Darden Restaurants (GMRI, Inc.) 1000 Darden Center Drive Orlando FL 32837 Phone Number: 407.458.8109 Position: Design Project Manager Date: Sig /l 2-- T e oregoing in , tr , ment was ackgowled before m is y of 44-- , 20 / LBy ! /f1 A/ L who is ersonalqknown to me or who has produced as identification. Signature o Notary Public gyp:, KELLY SOLOMON i *: "' r * . MY COMMISSION N EE 171433 W....wwie EXPIRES: February 20, 2016 gip; ,hit` Bonded Thru Notary Public underwriters 6001 NI M I'? PARKWAY, SOU'I'1I BEND, INDIANA 46628 TEE. 1.800.599.8121 FAX 574.237.6166 Existing: 14" x 7 -0" Awning Letters: 8.17 SF each (Qty 2) Site Plan O Proposed: 3'-4" x 7' -2" Critter: 23.89 SF Store #0457 O Proposed: 18" x 12-9 15/16" Channel Letters: 19.24 SF O Existing: 36" x 13-0" Channel Letters on Raceway: 54 SF (with 17 SF Critter) Proposed: 30" x 21' -3 13/16" Channel Letters: 53.29 SF ' i '5/4. 1 Existing: 3' -8 3/4" x 8' -5" Monument at 7-4" OAH: 31.39 SF i i i i el ■ O .� 7 r ,- 1 / t Proposed: 3' -0 1/2" x 8' -4" Monument at 6-5" OAH: 25.35 SF � , , — , , IIE Existing: 1' -10" x 1'-0" Parking Sign at 7'-0" OAH: 1.83 SF ._ V �' /n yl y„ D U ° ' 7t '\ • O Proposed: Replacement Logo on Parking Sign: 1.83 SF w .# • / r --- • , ....„9" . ..........., - ,c.....04 .,„.. C --\ .\ i B -- 7 —, - – r• ' , . i - . ,, .4 4//, 4 • e 4%d ,, # 14., . - s , 1. ,,,, ., , . j I E \ \\ \ \ \ \ \ \ \\' V\ \ \ \`, . . _ , ; .. ,i. . ,is Illg . r•r i 4*. , - -. -,, , , , iriti ' / a / ;- SE S) Ph: 1.800.599.7696 Fax 1.574.237.6166 www.siteenhancementservces.com Page 2 of 12 Existing: Approx. 8.17 SF Letters on Awning Sides � o ; - ni ti Front Elevation , CITY OF TIGARD ` Store #0457 p Et ' . ,.-, , Approved [ 14 �� l . a , Conditionally Approved I I R r "i! .1'::. PERMIT NO. ' described W) J 7 7 sa r.. J —= — �' See Letter to Follow 7 I j — .. 1 a Attach [ j _._ 106 , ,,.� Job Addr $s: / 7 •7,D 4u) 5; I .2114 e wY5 72-I r F �t � .... � , .'' iv, , By Date: i, / /'y 109' -5 1 /2" . « 17' .allb.... I _srr..._ _.n■rn■n■■.._ • I ■mumm r ■...■.■..■. .nonnnuonnu.._ nnna0000■P•• _ • MMIIMOMSOMOMMOSUOL_ ii uooarunouon ..r .. Zo i •I FRE FISH . -. LIM SITS, ,: il•- i - •il- •iii- •ir• i� =1 i 9 M v .. . ► �..RR� � , L U r � nou onnuro _ CO N i u.o.uu r ' : I I......000O.�.■..■.. EIO...i.. .O.ur■■... - - tD -• _VIII - niraill"Limnilailin ...111111111"."1111 I ............... _ ,II� ' ► _1111.. II I= IMI E T IIIIIIIIII _, (•I 11111,1 III III II ;��j'r ` -�l �i •i I ®_ = I ejt 4a •∎ �1";; Ts re •1 l rte I t•s 41 r MA' ir(.+ .w era Say - .L_- . kQoce. �:�� ,r. I I I I ► ►r b e��1 ►s° jai - ►�► �� �ai ►M ►�i ��i �• - .. �o -. �I� QS: Ih!:.�G�;::� - .� Scale: 1/16 " =1' 7 -2" fi ' ' 4"):41111111111111111110 . , • ' / ..... a .!T kk _ 03 10°411111111 in- - 1 14 5/8" , . A 24 Square Foot Critter (Internally LED Illuminated Cabinet) . ii - , ai �! -: Utilized Square Footage: 23.89 , // /�.� 1 /// j/ / ,1 Scale: Y2' " =1' _ "'N l-- 1/ \\\_\_\ \AA \ \V'„,A4,A \V',' \ / �i 7J Ph. 1.800. 599 7696 Fax. 1 . 574. 237 .6166 wwwx,teenhancementservlces.com Page 3 of 12 RL- SIG- 86CRITTER -LED _ 7' -2" GENERAL SPECIFICATIONS SPECIAL NOTES 1 CRITTER (REMOTE) CONSTRUCTED OF ALUMINUM BACKS BUILDING FASCIA TO BE HARDI -PLANK CEDAR SHAKE SIMULATION CRITTER: W/ ALUMINUM RETURNS EXTERIOR PRECOAT MATTE BLACK SO IT WILL BE UNEVEN SURFACE. ADJUST LETTERS TO WHERE THE 063" ALUM BACKS INTERIOR WHITE, W/ 1 " BLACK TRIM CAP ON A .177 CLEAR IMPACT MODIFIED FACES ARE ALL ON THE SAME PLANE. ACRYLIC FACE W/ 1st SURFACE DIGITAL PRINT APPLIED. ` 0��" RETURNS W/ REMOTE POWER SUPPLIES, W/ L.E.D WHITE MINI MAX ILLUMINATION. AND TO USE SILICONE CAULK FOR ALL PENETRATIONS. 3' -4" ELECTRICAL REQUIREMENTS KEY THESE AREAS Total: 3.0 Amps ° � i r e. ARE OPEN ■ 1 -120V, 20A Circuits Req'd „ DIGITAL GRAPHICS ALL BRANCH =UM SHALL ee DEDICATED To I SUPPLIED BY MIRATEC RL- SIG- 86CRITTER -LED 23.8 SQ FT. SIGNS N SHALL NO BESHAR (COLOR FORMULA'S BY OTHERS) LOADS. NOTE: DIGITAL GRAPHIC WILL ALWAYS Mil SCALE: 3/4" TO 1'-0" HAVE THE BLACK BORDER AROUND COMPLETE LOGO ANY TIME PRINTED. Tetrp LED Systems MATERIAL ESTIMATE t t 011572 -03 4" - ••• s+Kau INSTRUCTIONS s c n$ TE OM agile ROCCO MN ONO wrNi►1 .vg m CUSTOM% N1iQRMATtON ,.1-N 1 1 ILL-0i. Tl iio MN' waerra••• .1111111 HARDY PLANK FASCIA n 4 1.110 Swami, "�""'""'"" se P4 PLYWOOD BACKING V'''" . 40 @ HEIGHT 1 , v - .�,,..Ij 0 0-0 `41144-1.. 2 X 4 WOOD STUD WALLS I tensertt I e: remove po ' cuipp a II a DRYWALL( WHERE APPLICABLE) —' f SOICUCt 1.1 Go ),.' /a t % i c i rik, i, (7 a ±""'� e 'a'"'� It E L.E.D. POWER SUPPLIES � `,.......... - - IN U.L. TRANSFORMER BOXES �+�►• �� k r: ••. : 4eEA► l tMratae nubs• M f t A T,,i, CODE COMPLIANT ELECTRICAL HOUSINGS & WIRING METHODS /04 - O RL- SIG- 86CRITTER -LED IMPACT MODIFIED ACRYLIC 177 CLEAR / 0 .. r,..., tt.,.s. t" ""'" _ a......t " '""""mo.`'r " o so imi. two., a..' I.* ` """.." W/ 1st SURFACE DIGITAL GRAPHIC !' AEfh on FACE or Np JT 3 0 Amps la 1.8 watts 000 So Ft 0 00 watt.S/Sq Ft . I r • x «t..•R • NO evemplicarama a..t o- 00 -- • -_ CUT OFF SWITCH (LOCKABLE) — 11 No fl et ^v u resrd w fun ac-r s waea w `a a•� P trr .r,. "+. : sae - :... -. . t «t ., , ..t.•,.,�, .�, " �.'�« �.»..�.:,,.., �..., ...�x. TOGGLE BOLT OR OTHERS AS PER II MUNICIPALITIES REQUIREMENTS � •tt�,ra► � � � � � -�� _�* � , �� �� ;.� � �...�,�," � W/ SILICONE @EACH PENETRATION s ;,., aw <: t.'."++.x a =43c- a.r.. ,. y -.dr», -, . _• tf.+n..�+.� .a* , - -_ r , .-wa -,. ..... .a-aR _ I n unmm�unun r w ■ .. .....:,.,..� t » t »m. ..•.. .•..�.,........ neler,mc� RPV G.EO PERO TILEN II 9 „_ • • �, A, x„� AO trait r �•s =� ;' � , au..,; A+ Drwg # : 01 1572 -03 i Systems ! l * . t Lumination i na n t ...t ,I •. . .r .4..a1 a Tetra LED S y x t e 1 1 1 s , y • , — BLACK 1" TRIM CAP CUSTOMER TO PROVIDE: Notes: Certain electrical components of signs wi fall prematurely it signs are not shut -on fur a period of time, once, each day. For best performance, WEEP HOLES 2 PER LETTER (For New / Remodel Construction) ADEQUATE BEHIND THE WALL BACKING AND ACCESS AS REQUIRED TO INSTALL we recommend signs to be connected to an automatic controling device such as an Energy Management System, Time Clock or Photo CM that W/ WEEP HOLE COVERS SIGNAGE. CUSTOMER TO FORWARD COPY OF FINAL APPROVED SIGNAGE DRAWINGS TO BUILDING SITE CONTACT will automatically shut -off the sign for a period of time, each day. Failure to do so will cause damage to the electrical components of the sign and will void the warranty. SUSPENDED CEILING SO THAT THESE PROVISIONS CAN BE MADE DURING CONSTRUCTION AND PRIOR TO SIGN INSTALLATION. Some dimming devices will also adversely affect sign electrical components, causing failure. Any dimming of the sign without consultation (WHERE APPLICABLE) ALL BRANCH (PRIMARY ELECTRICAL SERVICE) CIRCUITS & FINAL CONNECTION TO EACH SIGN (WITHIN 5 FT.) TO BE BY CERTIFIED ELECTRICIAN: with Federal Heath Sign Co. will void the warranty. A. Al branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit). INSTALLER IS RESPONSIBLE FOR: SECTION D ETAI L B. Sign circuits must not be shared with other loads such as lighting, air conditioning, and other equipment C. Property sized ground wire that can be traced back to the breaker panel must be provided. • PROVIDING AND INSTALLING ALL COMPONENTS REQUIRED TO RUN SECONDARY WIRING (CONNECTORS, GTO CONDUIT, D. Number and size of circuits for each sign to meet Federal Heath Sign's requirement. ETC.) TO BE DETERMINED BY LOCAL CODE AND SITE CONDITIONS. SCALE: 1 - 1/2" TO 1' - • PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS. • SEALING BUILDING PENETRATIONS WITH SIUCONE TO PREVENT MOISTURE PENETRATION @ EXTERIOR LOCATIONS.. RL-SIG- 86CRITTER -LED Page 8 of 12