Loading...
SGN2012-00080 CITY OF TIGARD SIGN PERMIT Permit #: SGN2012 -00080 COMMUNITY DEVELOPMENT Date Issued: 05/11/2012 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2421 Parcel: 1S135AB01003 Jurisdiction: Tigard Name of Business: Red Lobster Business Address: 10330 SW GREENBURG RD Applicant/Agent: Work Description: Wall sign - Permanent: Yes Freestanding: Yes Freeway: No Temporary: Wall: No Electronic: No Billboard: No Balloon: No Banner: No A- Board: No Sign Dimensions: 3'x8'4" Total Sign Area: 25 Wall Area: Wall Face (Direction): Sign Height: 6.5 ft. Projection From Wall: in. Illumination: Internal Materials: Aluminum /acrylic Electrical Permit Required: Yes Building Permit Required: Yes Total Permit Fee: $165.00 Conditions: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon sign shall expire 10 days from validity date. Approved By: Permittee Signature: CITY OF TIGARD RECEIPT ! 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 TIGARD Receipt Number: 186698 - 05/11/2012 CASE NO. FEE DESCRIPTION REVENUE ACCOUNT NUMBER PAID SGN2012 -00080 Sign Permit 100 - 0000 -43115 $144.00 SGN2012 -00080 Sign Permit - LRP 100 - 0000 -43117 $21.00 Total: $165.00 PAYMENT METHOD CHECK # CC AUTH. CODE ACCT ID CASHIER ID RECEIPT DATE RECEIPT AMT Check 279631 HWATKINS 05/11/2012 $165.00 Payor: North American Signs Total Payments: $165.00 Balance Due: $0.00 Page 1 of 1 City of Tigard Sign Permit Application TIGARD Application GENERAL INFORMATION Name of Development /Project FOR STAFF USE ONLY Site Red Lobster Address/ Street Address Permit No.: e `%`/ !%t) /? — ,1 2 G OZ.? Location 10330 SW Greenburg Rd Suite /Bldg. # City/State Zip Approved By: 7 r S� /!/ Tigard, OR 97223 Date: //� / //Z Name Receipt #: , v k / S Property Knickerbocker Properties, Inc. Map /TL #: 5 ' I ,�^ 14 �-) l d U- Owner Mailing Address Suite Z on i ng: // L / � 235 Montgomery St 16th Floor Allowable Total Area: -7 U 9 /: Cit Zip Phone San Francisco, CA 94104 503- 412 -4800 Tenant or Name Electrical Permit Required? Yes ❑ No Business Red Lobster Building Permit Required? tomes ❑ No Name Rev. 7/1/11 is \curpin \ masters \land use applications \sign permit app.doc Vancouver Sign Group Sign Contractor Mailing Address Suite 2600 NE Andresen Rd 50 City/State Zip Phone REQUIRED SUBMITTAL ELEMENTS Vancouver, WA 98661 3 6 0- 6 9 3 - 4 7 7 3 (Note: applications will g9/ be accepted Oregon Const. Cont. Board License # Exp. Date without the required submittal elements) 63951 _ 01/24/2014 ❑ Completed Application Form Proposed ® Permanent ® Freestanding ❑ Freeway ❑ 2 copies of site /plot plan, drawn to scale Sign ❑ Temporary ❑ Roof ❑ Electronic (3 copies, if a building permit is required) (Check all that ❑ Wall ❑ Other t » 11", 11" 17" apply) size requirement: 8 /� x 11 , or 11 x 17 ❑ 2 copies of elevations, drawn to scale © New sign? ❑ Alter to existing sign? (3 copies, if a building permit is required) Sign Dimensions: 3 , -0: x S, _4° 784 size requirement: 81/2" x 11", to 24" x 36" Total Sign Area (sq. ft.): ..#f�r z 0)4' ❑ $165.00 Fee (Permanent sign, any size) Sign Data Total Wall A ft.) ❑ $52.00 Fee (Temporary sign, any type) (Complete all Direction Wall Faces (circle one): N/A • N OTES items in this . section) N S E W NE NW SE SW Height to top of sign (feet): 6 t _ 6 ti • Wall signs do not need to be drawn to scale, but Projection From Wall (inches): 1q /p, must include dimensions of wall face and sign placement. Materials: aluminum/acrylic ♦ Wall signs do not require site /plot plans. Will sign have illumination? © Yes ❑ No • Freestanding signs over 6 ft. required a building Type: © Internal ❑ External permit. Are there any existing freestanding or wall signs at this location, including wall signs that overlap a tenant space? © Yes ❑ No If "yes ", a list or diagram of all sign dimensions and square (OVER FOR SIGNATURES) footage must also be submitted. see sign packet for this info City of Tigard I 13125 SW Hall Blvd., Tigard, OR 97223 I 503- 718 -2421 I www.tigard - or.gov I Page 1 of 2 APPLICANTS: To consider an application complete, you will need to submit ALL of the REQUIRED SUBMITTAL ELEMENTS as described on the front of this application in the "Required Submittal Elements" box. NOTE: Person specified as "Applicant" shall be designated "Permittee" and shall provide financial assurance for work. * When the owner and the applicant are different people, the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s) must sign this application in the space provided on the back of this form or submit a written authorization with this application BY SIGNING BELOW, THE APPLICANT(S) SHALL CERTIFY THAT: • If the application is granted, the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in the plot plan, attachments, and exhibits transmitted herewith, are true, and the applicants so acknowledge that any permit issued, based on this application, and may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application, including the policies and criteria, and understands the requirements for approving and denying the application. I hereby acknowledge that I have read this application, that the information given is correct, that I am the owner or authorized agent of the owner, and that plans submitted are in compliance with the City of Tigard. SIGNATURES of each owner of the subject property are required. V27-/2 App ant Signature Date Signature of Owner /Agent Date Ty Robbins 574 - 232 - 4474 Contact Person Name Phone No. City of Tigard I 13125 SW Hall Blvd., Tigard, OR 97223 I 503- 639 -4171 I www.tigard - or.gov I Page 2 of 2 f „.. S RECEIVED SITE ENHANCEMENT SERVICES, INC MAY 1 12012 CITY OF TIGARD PLANNING /ENGINEERING We, Darden Restaurants (GMRI, Inc.), hereby authorize Site Enhancement Services, acting as agent for Darden Restaurants (GMRI, Inc.), to proceed with the sign permit request for Red Lobster located at 10330 SW Greenburg Rd., Tigard, OR 97223. We have reviewed the proposed sign changes and authorize Site Enhancement Services to move forward with the sign permit process and any /all issues regarding signage. Corporate Representative's Name: Randy Calvanelli Representative's Signature: 6-t41 Company Name: Darden Restaurants (GMRI, Inc.) 1000 Darden Center Drive Orlando FL 32837 Phone Number: 407.45 8.8109 Position: Design Project Manager Date: Sig ii 2- T e in tr ment was ackn e wldg bbef�orre m his who of l/ , 20 /By — �� �u,� �y AJ is personall known to me or who has produced as identification. / i Signature o Notary Public , = . filiA KELLY SOLOMON I s !a■ MY COMMISSION # EE 171433 �� . EXPIRES: February 20, 2016 %?; of ;! ' Bonded Thru Notary Public Underwriters API. 6001 NIM'FZ PARKWAY, SOUTH BEND, INDIANA 46628 TEL. 1.800.599.8121 FAX 574.237.6166 Existing: 14° x T-0" Awning Letters: 8.17 SF each (Qty 2) Site Plan O Proposed: 3'-4" x7-2" Critter: 23.89 SF Store #0457 O Proposed: 18" x 12' -9 15/16" Channel Letters: 19.24 SF Existing: 36" x 18'-0" Channel Letters on Raceway: 54 SF (with 17 SF Critter) O Proposed: 30" x 21' -3 13/16" Channel Letters: 53.29 SF ' t� ' / / Existing: 3' -8 3/4" x 8' -5" Monument at T -4" OAH: 31.39 SF / f / ' \ , v O s \ ° _ . ,., ,-. Proposed: 3'-0 Y2 " x 8'-4" Monument at 6' -5" OAH: 25.35 SF \Jr, c 77' e't , lit, � :- 2K is ,, ..,r 4 10. Existing: 1' -10" x 1' •0" Parking Sign at 7-0" OAH: 1.83 SF isi) iii 4ly Proposed: Replacement Logo on Parking Sign: 1.83 SF , - v IL ---- -- C " •ice► i . B -- i S , D _ 'k .. , — i i . ,,a,,, 7/ti, ofi , i 0 - t _ E \\0\\\ \\ \\\ \i, \'\\,. e Vr . r r ,� ti '-1.r % SE) Ph: 1.800.599.7696 Fax:1.574.237.6166 ww wsiteenhancementsenaces.co m Page 2 Of 12 Monument Overlay Store #0457 o See page 2 for sign location �" } el , ► ' ' P a it i r a m ; � 1 < • a.,�r t ■ se .. • -"' • + lam • • . , mZ ?ma t � a .. • f f p ' %11- ..c , V f p 4 '. , to O. 0 : e . V lotill,' V- ; :- ---... \---. _ - go of a 0', 0 1 M ER a __ ._. __.\ t FRESH FISH • LIVE LOBSTER = M Existing: •.— — � w - . -�,,. ••• - ._ LW ..low 411s• ----- 3'-8 3/4" x 8' -5" at T -4" OAH • .J ,,o 4th.n 31.39 SF - v _ - _ t b I ■ . . ... _ ." ^ Ai . . ' 'J p , 11111111 1 i, \ ' „ . t 5r- t Orr .: lPtsi N ; •: : 4 1.!. , ,:, INIF411411 f $ , # ,,,, • , 4 '' . " • . : els lib s ,, , .,. i ii _ . . , . impearis _ v r - • I 40 .14 S Ste/ Ph: 1 800 599 7696 Fax 1 .574.237.666 www.siteenhancementservices.com Page 6 of 12 Illumination details required from sign manufacturer. RL- SIG -M25 -PPCL -LED CUSTOMER TO PROVIDE: (For New / Remodel Construction) ADEQUATE BEHIND THE WALL BACKING AND ACCESS AS REQUIRED TO INSTALL SIGNAGE. CUSTOMER TO FORWARD COPY OF FINAL APPROVED SIGNAGE DRAWINGS TO BUILDING SITE CONTACT 8' -4" SO THAT THESE PROVISIONS CAN BE MADE DURING CONSTRUCTION AND PRIOR TO SIGN INSTALLATION. ALL BRANCH (PRIMARY ELECTRICAL SERVICE) CIRCUITS & FINAL CONNECTION TO EACH SIGN (WITHIN 5 FT.) TO BE BY CERTIFIED ELECTRICIAN: 2' 11 1 /z" A. All branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit). 2' /z" Radius B. Sign circuits must not be shared with other loads such as lighting, air condfioning, and other equipment. C. Properly sized ground wire that can be traced back to the breaker panel must be provided. D. Number and size of circuits for each sign to meet Federal Heath Sign's requirement. /� _ deviation from the above recommendations may result in: f <<r� 1 - ,� '� ,._5 Total: TBD Amps - TS Any 1. Damage to or improper operation of the sign(s). � _ r '- i 2. Delays and additional costs. 1 -120V, 20A Circuvs Req'd 3 1 /2 AL LBRAN CHCIRCU"SSHALLBEDEDICATEDTO Notes: Certain electrical components of signs will fail prematurely if signs are not shut -off for a period of time, once, each day. For best performance, SI ` A. IB7f:lI0W GROUND lq G GROU AND NEUTRAL) A T SHALL S(IN B E E we recommend signs to be connected to an automatic controlling device such as an Energy Management System, Time Clock or Photo Cell that will automatically shut -off the sign for a period of time, each day. Failure to do so will cause damage to the electrical components of the sign and '� Q :i: will void the warranty. L= ft Is TO Br [MIT Pier ruarnL+r Some dimming devices will also adversely affect sign electrical components, causing failure. Any dimming of the sign without consultation QD FRESH FISH • LIVE LOBSTER e° - 3 with Federal Heath Sign Co. will void the warranty. • MANUFACTURING WILL PROVIDE A STUB PIPE WITH SIGN INSTALLER IS RESPONSIBLE FOR: L J CABINETS ONLY IF O.A.H. (CABINET + STUB PIPE) DOES NOT • PROVIDING AND INSTALLING ALL COMPONENTS REQUIRED TO RUN SECONDARY WIRING (CONNECTORS, GTO CONDUIT, 4 1 .9 " EXCEED !' -T MAXIMUM SHIPPING HEIGHT RESTRICTIONS. ETC.) TO BE DETERMINED BY LOCAL CODE AND SITE CONDITIONS. 25.35 SF ALL SUPPORTING STEEL, INCLUDING STUB PIPE, If NOT INCLUDED WmICABINET, • PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS. Scale: 1/2" = 1' TO BE SHIPPED TO INSTALLATION SITE BY AN OUTSIDE SUPPLIER OR BY THE INSTALLATION CONTRACTOR, AS DETERMINED BY PROJECT MANAGEMENT. • SEALING BUILDING PENETRATIONS WITH SILICONE TO PREVENT MOISTURE PENETRATION @ EXTERIOR LOCATIONS.. NOTE: UPON CUSTOMER ACCEPTANCE, FEDERAL HEATH ENGINEERING DEPT. WILL PROVIDE, FABRICATION DRAWINGS COLOR KEY AND ENGINEERED SEAL DRAWINGS IF REQUIRED. "MAIN CABINET" ® DIGITAL GRAPHICS THIS DRAWING IS FOR PRESENTATION ONLY CONSTRUCTED W/ CONVENTIONAL CONSTRUCTION METHODS OF I SUPPLIED BY: MIRATEC ANGLE IRON & ALUMINUM SKIN FOR FACE & SIDES. MI (COLOR FORMULAS BY OTHERS) INTERIOR SUPPORT STEEL TO BE DETERMINED !- 1 (WHITE) - WHITE .177 ACRYLIC # 2447 ALL OF THE CABINET TO BE PAINTED (BLACK SATIN FINISH) I. BLACK (SPRAYLAT - JET BLACK RAL 9005 SATIN) "CRITTER" CRITTER LOGO OF CHANNEL LETTER CONSTRUCTION TO BE ATTACHED 8' -4" TO CABINET FACE. .- THESE AREAS ', 4" r __ 2 ' -O " 4" CRITTER FACE OF CLEAR IMPACT MODIFIED ACRYLIC 4 0 �,` t . ARE OPEN W/ 1st SURFACE DIGITAL GRAPHIC APPLIED. TO HAVE A 1" BLACK TRIM CAP ADDED. ' ....— �� INTERIOR ILLUMINATION OF WHITE MINI MAX L.E.D. MODULES W/ POWER SUPPLY O " EXTERIOR TO BE PRECOAT MATTE BLACK INTERIOR WHITE. NOTE: DIGITAL GRAPHIC WILL ALWAYS , "RED LOBSTER" HAVE THE BLACK BORDER AROUND � D T L O B S TE "RED LOBSTER " OF CHANNEL LETTER CONSTRUCTION TO BE ATTACHED COMPLETE LOGO ANY TIME PRINTED. M R �( )> TO CABINET FACE. — MAIN CABINET: .090 "ALUM. En FRESH FISH -LIVE LOBSTER FACE OF # 2447 WHITE .177 ACRYLIC AND TO HAVE A 1" BLACK TRIM CAP ADDED. CHANNEL LTRS & CRITTER: Fc -Q— -- — ,-- INTERIOR ILLUMINATION OF GE MINI -MAX WHITE L.E.D. MODULES W/ POWER SUPPLY .063" ALUM BACKS i, EXTERIOR TO BE PRECOAT MATTE BLACK INTERIOR WHITE. .040" RETURNS ' "FRESH FISH LIVE LOBSTER." "FRESH FISH - LIVE LOBSTER " =.� r .. I � PILL BOX STYLE CABINET 4" DEEP TO BE ATTACHED TO CABINET FACE. i : _ - , f - - ` " RETURN OF: .063 ALUM, & FACE TO BE OF .125 ALUM COPY IS ROUTED _ OUT AND BACKED W/ #2447 WHITE .177 ACRYLIC. THIS FACE TO ATTACH `, .. -- " TO THE RETURNS "SHOE BOX INSERT STYLE, AND USE C.S. SCREWS THRU THE RETURNS & INTO INTERIOR WELDED 1" LIP ON BACK OF FACE. ( FOR SERVICE) NO BAFFLES IN ANY OF ILLUMINATION W/ GE WHITE MINI MAX L.E.D.'s. W/ POWER SUPPLIES. THE LETTERS. EXTERIOR PAINT TO MATCH PRECOAT MATTE BLACK INTERIOR WHITE. RL- SIG -M25 -PPCL -LED "ELEVATION" "SIDE VIEW" NOTE: FOUNDATION & SUPPORT STEEL: TO BE DETERMINED SCALE: 3/8" to 1' - 0" RL- SIG -M25 -PPCL -LED Page 11 of 12