Plans nee. q 9'- GZoyp ITEM NO.
s
ENTMA T i TM MODELS
ECO -CWE -CBP without Exhaust Duct Fire Damper ❑
AA
l ti "I 1•: N I S ECO -SWE -CBP with Exhaust Duct Fire Damper ❑
PORTLAND, OREGON • 1- 503 - 691 -2511 SELF COMPENSATING VENTILATOR
1-1 +1+ UL LISTED AT
Pl>.5---711 MINIMUM
260 CFM PER
LINEAL FOOT
Air Curtain By Pass
Make Up Air.
Model CBP. I I 1 ' I % . 6 . 4 4 -'.-- % '%.' . - % - . . % - - - - - - - - - - - - — - - - - - -- si% I il I % %I I I II I IN I I ■- - - - - - - "
(O i UL LISTED / WO '
.r: 0 FILE # MH 12660,
MI 0 MH 12532
•
EQUIPMENT SPECIFICATIONS Ventilator to have following standard features:
U.L Listed vapor proof globe type incandescent
To be Model ECO- -CBP wall mounted, self light fixtures on 3' centers, interwired to
compensating ventilator with integral make -up air chamber, junction box.
complying with NFPA -96, bearing NSF approval and U.L. Aluminum baffle grease extractors.
t - listing as manufactured by VENTMATIC SYSTEMS, INC.
Ventilator to have following options:
Item to be long x wide x deep in Stainless steel baffle grease extractors.
section(s) as per drawing. Unit(s) constructed of 18 U.L. Listed recessed incandescent light fixtures on
gauge, stainless steel with external seams and joints welded 4'-0' centers, interwired to junction box.
liquid tight. All exposed surfaces are to be polished to the U.L. Listed recessed fluorescent light fixtures on
original finish. 6' -0" center, interwired to junction box.
110 Volt light switch. Surface mount in stainless
Unit(s) to have U.L. classified baffle grease extractors, steel
mounted in stainless steel frame with removable stainless Surface Volt fan
mount in n stainless switch
steel chasefor exhaust and supply.
Su.
steel grease cup and trough. Unit to have factory installed Insulated supply plenum.
high duct collar(s). 3" rear air space.
3" top air space.
Front of ventilator to incorporate internal supply air chamber. 3' side air space. Left Right
Supply collar to include fire damper(s). Side skirts (insulated) (single skin).
Fascia panels, on side(s) to a
high ceiling.
Exhaust Fire Damper. .
MECHANICAL REQUIREMENTS
EXHAUST REQUIREMENTS: SUPPLY REQUIREMENTS:
Total CFM required. Total CFM required.
Total exhaust collar(s) @ .75' S.P. each. Total supply (ollars) @ .50' S.P. each.
( ) x collar(s) size @ CFM each. ( ) x collar(s) size @ CFM each.
L
Y S T E M S
A93 1
i
MODELS
ECO -CWE -CBP without Exhaust Duct Fire Damper ❑
ECO -SWE -CBP with Exhaust Duct Fire Damper ❑
E764PBT SUPPLY WV
CCLLAR F IRE DAMPER
B
T.,,,,,,,,,,,,,
.0" . s . to
# k E .
• roki me k
k
r • # .0 . '
c o
j[ I VS REM /MU 8 QP
*.. 1 +o Ms+.. or wuc.
TT Ton+
- ` DIR CURTAIN
i
DISCHARGE
CBP
INCLUDED AS STANDARD: _ 3/16" HOLES
1/4" APART ON STRGG REO
UNIT - 18 GA S/S CONSTRUCTION ALL EXPOSED CENTERS
SURFACES. FABRICATED TO COMPLY WITH
NFPA -96 WITH SEAMS. AND EXTERNAL JOINTS
CONTINUOUSLY WELDED LIQUID TIGHT. BEARING
NSF APPROVAL AND U.L. LISTING.
GREASE EXTRACTORS - ALUMINUM U.L CLASSIFIED
BAFFLE TYPE GREASE EXTRACTORS MOUNTED IN t- ® s°
S/S FRAME. C Daum
.n.
GREASE CUP - S/S REMOVABLE.
DUCT COLLAR(S) - FACTORY INSTALLED 4' HIGH, OPTIONS
SUPPLY DUCT TO INCLUDE FIRE DAMPER. SS EXTRACTORS 3' REAR AIR SPACE PANEL
LIGHT(S) - U.L. LISTED VAPOR PROOF GLOBE TYPE INCANDESCENT LIGHTS 7 TOP AIR SPACE
• INCANDESCENT LIGHT FIXTURES ON 36" CENTERS. FLUORESCENT LIGHTS 3' SIDE AIR SPACE
INTERWIRED TO J -BOX. 110V LIGHT SWITCH L R
VENTILATOR CAPTURE DEPTH SHOULD OVERHANG 110V FAN SwrrCH SIDE SKIRTS
COOKING EQUIPMENT 12' ON EXPOSED SIDES AND FASCIA FILLER PANEL INSULATED SUPPLY PLENUM
FRONT TO SATISFY MOST CODES AND TO ASSURE r
PROPER CAPTURE OF COOKING VAPORS. EXHAUST FIRE DAMPER
- MECHANICAL REQUIREMENTS
EXHAUST REQUIREMENTS: SUPPLY REQUIREMENTS:
Total CFM required. Total CFM required.
Total exhaust collar(s) @ .75' S.P. each. Total supply collar(s) @ .50" S.P. each.
( ) x collar(s) size @ CFM each. ( ) x Supply collar(s) size @ CFM each.
LENGTH WIDTH DEPTH For double battery cooking fines two (2) ventilators back to back (with back filler
A B C Panels if required) can be used.
Exhaust velocity, Minimum 1500 FPM, Maximum 2500 FPM
PROJECT:
LOCATION:
VENTMAT Y S T E M S -
2 SUBMITTED BY: I DATE: A93
AIR VOLUME CHART U.L. LISTED AND U.L. CLASSIFIED
WALL MOUNT EXHAUST CANOPIES AND VENTILATORS
SECTION LENGTHS
s.
Length In Feet 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0
Min. Exhaust CFM 1040 1170 1300 1430 1560 1690 1820 1950 2080
*Collar Dimension 12x8 12x9 12x10 12x10 12x11 12x12 12x13 12x14 12x15
Supply CFM 800 900 1000 1100 1200 1300 1400 1500 1600
*Collar Dimension 8x15 8x17 8x19 8x21 8x22 8x26 8x28 8x31 8x34
SECTION LENGTHS
Length in Feet 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Min. Exhaust CFM 2210 2340 2470 2600 2730 2860 2990 3120 3250
'Collar Dimension 12x15 12x16 12x17 12x18 12x19 12x21 12x22 12x23 12x24
Supply CFM 1700 1800 1900 2000 2100 2200 2300 2400 2500
'Collar Dimension 8 x 36 8 x 38 2 -8 x 17 2 -8 x 19 2 -8 x 20 2 -8 x 21 2 -8 x 22 2 -8 x 22 2 -8 x 25
SECTION LENGTHS
Length in Feet 13.0 13.5 14.0
NON - CANOPY HOODS
MM. Exhaust CFM 3380 3410 3540
Feet Exhaust Collar
'Collar Dimension 12 x 25 12 x 26 12 x 27
4.0 1040 7x 12
Supply CFM 2600 2700 2800
4.5 1170 7 x 14
'Collar Dimension 2 -9 x 23 2 -9 x 24 2 -9 x 25
5.0 1300 7x 16
5.5 1430 7 x 18
Ventilator Hoods up to 10'0 ", exhaust collars can be 6.0 1560 7 x 20
placed Left to Right at any location in the hood.
-- Ventilator hoods 10'1" up to 14'0" with one exhaust 6.5 1690 7 x 22
duct, the exhaust duct collar must be placed no 7.0 1820 7 x 24
more than 24" Left or Right to the center of the z 7.5 1950 7 x 26
hoods. W
J
D 8.0 2080 7 x 28
o
The above collar dimensions may vary to = 8.5 2210 8 x 25
accomodate each building structure, collar size >- 9.0 2340 8 x 27
must be able to move the required volume of air at a.
the correct velocity. Minimum exhaust velocity 1500 a 9.5 2470 8 x 28
FPM, maximum 2500 FPM. z 10.0 2600 8 x 30
Double the CFM's for island type exhaust ventila- z • 10.5 2730 8 x 32
tors. 11.0 2860 9 x 29
11.5 2990 9 x 30
12.0 3120 9 x 31
12.5 3250 9 x 32
13.0 3380 10 x 30
13.6 3410 10 x 31
14.0 3540 10 x 32
Minimum 260 CFM/Linear Foot Exhaust
S
A93 PORTLAND, OREGON • 1- 503 - 691 -2511