Loading...
Correspondence „6-f,e, 76p — CITY OF TIGARD OREGON March 4, 1997 G.A. Bently Construction Inc _ PO Box 363 Gresham OR 97030 RE: Certificate of Occupancy, Carl's Jr Restaurant, 15520 SW Pacific Hwy, Tigard OR The City of Tigard has granted Occupancy as of February 24, 1997. See the following copy of the approved building inspection. This final inspection notice serves as the Temporary Certificate of Occupancy, until which time we are able to process the Certificate of Occupancy. The Certificate of Occupancy will be mailed to the property owner as soon as possible. Given our current workload level, this could take a couple of months. If you have any questions, please feel free to call me. Sincerely, Jeanne Temple Building Division 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Tigard: CARL'S JR. Second Plan Review LP Job No. 96522.061 City No. BUP 96 -0469 MEC 96 -0096 SIT 96 -0036 SEPTEMBER 27, 1996 ROBERT R. KLAS EKA ARCHITECTS AND PLANNERS P.C. 6775 SW 111TH, SUITE 20 BEAVERTON, OR. 97008 Linhart Peterson Powers Associates (LP has completed re- review of the following documents. These documents were reviewed only for their conformance to the City of Tigard building regulations and the State of Oregon Specialty Codes, 1996 Edition. This review does not include interior plumbing, electrical or fire sprinkler and fire alarm modifications. These shall be submitted and reviewed by the City of Tigard. Architectural Drawings sealed by Registered Architect Robert R. Klas, Sheets: T -S; L -1 through L3; A -1, through A -13; R -1, R -2; K -1 through K -8. Structural Drawings sealed by Professional Engineer Michael Coronel, Sheets: S -1 through S -5. Structural Calculations sealed by Professional Engineer Michael Coronel, Sheets: (12) pages. Mechanical Drawings sealed by Professional Engineer Tai Funatake, Sheets: M -1 through M -5 Civil Site Drawings sealed by Professional Engineer Timothy McGuire, Sheets: C -1 through C -5. Site Plumbing Drawings sealed by Professional Engineer Tai Funatake, Sheets:P -1, P -2. PROJECT INFORMATION 15520 SW PACIFIC HWY. TIGARD, OR 97223 OCCUPANCY GROUP: A -3/B CONSTRUCTION TYPE: V -N STORIES: 1 FLOOR AREA: 3,045 SQ. FT. OCCUPANT LOAD: DINING - 92 KITCHEN - 6 PLAY AREA - 43 TOTAL OCCUPANT LOAD 141 LINHART PETERSEN POWERS ASSOCIATES V IA 3855 -3 Wolverine Street NE • Salem, OR 97305 (503) 371 -2212 • FAX: (503) 371 -3853 Tigard - CARL'S JR. LP RECOMMENDS THE ISSUANCE OF THE BUILDING AND MECHANICAL PERMITS FOR THIS PROJECT. GENERAL COMMENTS 1. Sheet T -1 identifies this building as a Group M Occupancy under Project Data. Group M Occupancies are occupancies for the display and sale of merchandise. Please revise this sheet to correctly identify the building as a mixed occupancy A-3/B. Response: Revised cover sheet submitted and approved. Status: Resolved. Please submit plans to the Washington County Health Department for review and approval. A final inspection shall be conducted by this agency prior to occupancy. Response: Per the applicant, this is in process. Status: Resolved. 2. The prefabricated walk -in coolers shall be approved by the Prefab Structures Section of the Oregon Building Codes Division and shall bear their approved insignia. Section 1704 O.S.S.C. Response: Per the applicant, this is in process. Status: Resolved. SITE REVIEW COMMENTS No comments. FIRE & LIFE SAFETY COMMENTS 3. Detail 16 on Sheet A -6 identifies the 1 -Hour fire- resistive shaft construction as using U.L. #510. Please note that this assembly is a proprietary system and is required to be constructed with the gypsum materials listed in the U.L. Directory. Please submit a copy of this listing for attachment to the plans. Response: Listing has been submitted and approved. Status: Resolved. 4. The occupant load shall be posted in a conspicuous place on an approved sign near the main exit of the dining area. Section 1002.3 O.S.S.C. Response: Per the applicant, the occupant load will be posted. Status: Resolved. STRUCTURAL COMMENTS 5. No comments 2 Tigard - CARL'S JR. 6. MECHANICAL COMMENTS 7. Please submit the gas piping plans for all gas appliances for our review. Please include pipe sizes and the overall developed length of the gas piping. Response: Plans submitted and approved. Status: Resolved. 8. The suspended ceiling grid shall be of 1 -Hour fire- resistive construction if the Type I hoods are within 18 inches of the ceiling and shall be flashed with a minimum 22 gage steel or with materials conforming to 1 -Hour fire0resistive construction. Section 508.4 O.M.S.C. Response: The ceiling has been changed to conform to this requirement. Status: Resolved. 9. Upon completion and before final approval of the installation, a performance test shall be made to verify the rate of airflow and proper operation of the Type I hood and duct systems. The permittee shall furnish the necessary test equipment and devices required to perform the tests. Section 508.10 O.M.S.C. Response: Status: ACCESSIBILITY /CHAPTER 31 COM MENTS 10. The van accessible parking space shall have an additional sign marked "Van Accessible" mounted below the required sign. Section 1104.1 O.S.S.C. Response: Revised details submitted and approved. Status: Resolved. ENERGY C ONSERVATION CO MMENTS 11. No comments. If we can be of further service to you, please call us at 371 -2212. Respectfully, LINHART PETERSEN POWERS ASSOCIATES C•7 / Gary Lampella Building & Mechanical Inspector /Plans Examiner c: David Scott, Building Official 3 E KA ARCHITECTS & PLANNERS, P.C. Robert R. Klas AIA, CSI 6775 S.W. 111th Avenue - Suite 20 Beaverton, Oregon 97008 PH: (503)644 -4222 FAX: (503)644 -6567 RIECJEI[VED JOB MEMO: RRK/kr SEP 1 9 1996 LINHART PETERSEN POWERS ASSOCIATES PROJECT NAME: Carl's Jr. Restaurant - Tigard, OR PROJECT NUMBER: 96 -13 DATE: 13 September 1996 SUBJECT: City Plan Check # BUP96 -0469 DISTRIBUTION: City Of Tigard Building Department (2) Linhart- Peterson - Powers and Associates (1) Gene Snyder (1) Tom Oly (1) The following is in response to plan check from Linhart- Peterson - Powers and Associates dated September 12, 1996: Item 1: Sheet T -1 - occupancy has been changed to A3 /B. Item 2: Project has been submitted to Washington County Health Department for approval. Item 3: The prefabricated walk -in has been submitted for approval to the prefab structure section of the Oregon Building Codes Division. See enclosed approval. Item 4: UL 510 listing is enclosed. Item 5: An approved sign indicating maximum occupant load in the dining room will be located as directed by the Fire Marshall prior to or during a final walk through with the Fire Marshall for approval. Item 6: See enclosed letter from Mech. Engineer, MFIA, dated 9/13/96. Item 7: The suspended ceiling has been changed to construction and flashed with 22 gauge steel. See enclosed Sheet A -13. Item 8: Specifications require the contractor to perform a test to verify that the airflow and operation of the type 1 hood and duct systems complies with code and owner's requirements. Item 9: This site plan indicates that the left handicap parking space is van accessible. Detail 19 on sheet A2 (enclosed) is revised to indicate that the sign in front of the space will be installed accordingly. We assume this completes all requirements for Fire, Life and Safety, and structural approval for permit. We understand that mechanical, plumbing, and electrical submittals for permit were made at the same time as these construction documents were submitted. We further understand that the subcontractors for these trades will be required to pick up these permits in person. Please let us know if there are any questions to be responded to as soon as you can. 9 -12 -1996 10:41AM FROM P. 2 Tigard: CARL'S JR. First Plan Review LP Job No. 96522.061 City No. BUP 96 -0469 MEC 96 -0096 SIT 96 -0036 SEPTEMBER 12, 1996 • ROBERT R. KLAS EKA ARCHITECTS AND PLANNERS P.C. 6775 SW 111TH, SUITE 20 • BEAVERTON; OR. 97008 LP (Linhart Peterson Powers Associates) has completed review of the following documents. These documents were reviewed only for their conformance to the City of Tigard building regulations and the State of Oregon Specialty Codes, 1996 Edition. This review does not include mechanical, plumbing, electrical or fire sprinkler and fire alarm modifications. These shall be submitted and reviewed by the City of Tigard. Architectural Drawings sealed by Registered Architect Robert R. Klas, Sheets: T -S; L -1 through L3; A -1, through A -13; R -1, R -2; K -1 through K -8. Structural Drawings sealed by Professional Engineer Michael Coronel, Sheets: S -1 through S -5. Structural Calculations sealed by Professional Engineer Michael Coronet, Sheets: (12) pages. Mechanical Drawings sealed by Professional Engineer Tai Funatake, Sheets: M -1 through M -5 Civil Site Drawings sealed by Professional Engineer Timothy McGuire, Sheets: C -1 through C-5. Site Plumbing Drawings sealed by Professional Engineer Tai Funatake, Sheets:P - 1, P - 2. PROJECT INFORMATION 15520 SW PACIFIC HWY. TIGARD, OR 97223 OCCUPANCY GROUP: A -3B CONSTRUCTION TYPE: V -N STORIES: 1 FLOOR AREA: 3,045 SQ. FT. OCCUPANT LOAD:. DINING - 92 KITCHEN - 6 PLAY AREA - 43 TOTAL OCCUPANT LOAD 141 LXNIIART PETERSEN POWERS ASSOCIATES tiplAv 3855 -3 Wolverine Street NE • Salem, OR 97305 (503) 371 -2212 • FAX: (503) 371 -3853 9 -12 -1996 1 0 : 42AM FROM P. 3 Tigard - CARL'S JR. LP DOES NOT RECOMMEND THE ISSUANCE OF THE BUILDING PERMIT FOR THIS PROJECT SUBJECT TO THE FOLLOWING ITEMS: GENFR AI, COMMENTS 1. Sheet T -1 identifies this building as a Group M Occupancy under Project Data. Group M Occupancies are occupancies for the display and sale of merchandise. Please revise this sheet to correctly identify the building as a mixed occupancy A -31B. 2. Please submit plans to the Washington County Health Department for review and approval. A final inspection shall be conducted by this agency prior to occupancy. 3. The prefabricated walk -in coolers shall be approved by the Prefab Structures Section of the Oregon Building Codes Division and shall bear their approved insignia. Section 1704 O.S SITE E, F.W CO MENTS No comments. FIRE &LIFE SAFETY COQ 4. Detail 16 on Sheet A -6 identifies the 1 -Hour fire - resistive shaft construction as using U.L. #510. Please note that this assembly is a proprietary system and is required to be constructed with the gypsum materials listed in the U.L. Directory. Please submit a copy of this listing for attachment to the plans. 5. The occupant load shall be posted in a conspicuous place on an approved sign near the main exit of the dining area. Section 1002.3 O.S.S.C. STRUCTURAL COMMENTS 6. No comments )1 ANICA COMMENTS 7. Please submit the gas piping plans for all gas appliances for our review. Please include pipe sizes and the overall developed length of the gas piping. 8. The 'suspended ceiling grid shall be of 1 -Hour fire-resistive construction if the Type I hoods are within 18 inches of the ceiling and shall be flashed with a minimum 22 gage steel or with materials conforming to 1 -Hour fireOresistive construction. Section 508.4 O.M.S.C. 2 9 -12 -1996 10:42AM FROM P.4 • Tigard - CARL'S JR. 9. Upon completion and before final approval of the installation, a performance test shall be made to verify the rate of airflow and proper operation of the Type I hood and duct systems. The permittee shall furnish the necessary test equipment and devices required to perform the tests. Section 508.10 O.M.S.C. ACCESSIBILITY /CHAPTER 31 COMMENTS 10. The van accessible parking space shall have an additional sign marked "Van Accessible" mounted below the required sign. Section 1104.1 O.S.S.C. ENFRGY_CONSERV*TION COMMENTS 11. No comments. If we can be of further service to you, please call us at 371 -2212. Respectfully, LINHART PETERSEN POWERS ASSOCIATES 6'‘p P rfri4 Gary Lampella Building & Mechanical Inspector /Plans Examiner c: David Scott, Building Official • • • 3