Loading...
Correspondence MU LVANN ; Y ; G 2 TRANSMITTAL DESIGN AT wO TO City of Tigard, Building Division DATE 06.24.04 ATTN Brian Blaylock PROJECT Safeway #1478 PHONE (503) 639 -4171 • 15570 SW Pacific Hwy FAX (503) 598 -1960 PROJECT NUMBER 03- 1624.01 FROM Stasi Perrigo NUMBER OF PAGES Including Cover Page CC file, Safeway Inc., Kendall Const. SEND VIA Hand Deliver RE Safeway #1478 Interior Remodel - New Minor Entry Canopy 0 Z 1 g i W iv I W _ QTY DESCRIPTION 1 o o °� 31 W M 1 0 yr w =.e 04 Mw 6C 1 AS I #5 (8 %z" x 11") X X X 2 Full Sized Sheets (A1.1, A2.2, A5.1, A5.2, S1.1, S2.1, S2.2, X X X S2.3, E0.1, E2.1) 2 Structural Calculations, 06.18.04 NOTES Brian, Here are more revisions to BUP2003- 00677. Please note, Dan Salvey from our office met with Morgan Tracy at the Planning Counter last week. Morgan indicated he would sign off on the exterior revision when it was in to you for review. Please do not hesitate to contact me if you have any questions, Thank you, Stasi Perrigo Project Manager MulvannyG2 Architecture 601 SW Second Ave. Portland Or, 97204 (503)223 -8030 • (971) 223 -0723 (971)223 -0748 fax • Privileged and confidential Information: the information In this document is Intended only for the use of the above named recipient. Any wrongful review, dissemination, distribution or copying of this communication Is strictly prohibited. If errors occur in transmission, or enclosures are not as noted, please notify us at once. 503., . .6Q1 SW,'SECONI Avt NUE I SU1 I PORTLAND Oli'.1 97204 S03.223 8361 : 'MulvaonyG2.com ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS OWNER:' ARCHITECT: CONSULTANT: ❑ CONTRACTOR: FIELD: ❑ OTHER: This document has important legal consequences; consultation with an attorney is encouraged with respect to its completion or modification. PROJECT: Safeway #1478 ARCHITECT'S SUPPLEMENTAL INSTRUCTION NO.:05 OWNER: Safeway Inc. 13600 SE Eveyln St ISSUE DATE:06.21.04 Clackamas, Or 97015 ARCHITECT'S PROJECT NO:03- 1624 -01 TO: Kendall Construction 17436 SE Kendall Ct. ARCHITECT:MulvannyG2 Architecture Portland, OR 97236 • CONTRACT DATED: CONTRACT FOR: Interior POC Remodel The work shall be carried out in accordance with the following supplemental instructions issued in accordance with the Contract Documents without change in the Contract Price or the Contract Time. Proceeding with the work in accordance with these instructions indicates your acknowledgement that there will be no change in the Contract Sum or the Contract Time. Description: Architectural: Add new canopy over Minor Entry Doors Electrical: Add Electrical and Lighting at Minor Entry canopy Structural: New steel canopy structure New Columns to support canopy Attachments: A1.1 Floor Plan 06/23/04 A2.2 Exterior Elevations 06/23/04 A5.1 Reflected Ceiling Plan 06/23/04 A5.2 Reflected Ceiling Details 06/23/04 S1.1 Foundation Plan 06/18/04 S2.1 Roof Framing Plan 06/18/04 ,S2.2 Roof Framing Details 06/18/04 S2.3 Roof Framing Details 06/18/04 E0.1 One -LLine Diagram 06/15/04 E2.1 Electrical Lighting Plan 06/15/04 • • ISSUED BY: fr -SiCit{r.) c�rp, s�,:� 1 --tb Signature Name and Title Vim. ELT MA4. MoLvokra i ' ErZ I crua • • •