Loading...
Specifications 4 ^ . ' ' i i . ' I. I ,: ,_ Y , 0 4 DESIGN, INSTALLATION, 0 MAINTENANCE & RECHARGE • MANUAL a •i r• • r • l I : • • e lil 4111.... • RECEIVED • 1.2385 REV. A SEP o s 2001 • I V EI EX KP GOOF TIC O P mben 0 ._� -. _ B UIL IINGOW1810N 0 o Ag:;M s . ' /1'o EST,AU RANT 0 FIRE SUPPRESSION SYSTEM 0 O , TESTED AND LISTED BY 0l UNDERWRITERS LABORATORIES 0 TO UL STANDARD 300 and UNDERWRITERS LABORATORIES OF CANADA 0 ULC /ORD 1254.6 -1995 0 . 0 1 AMEREX CORPORATION OFFICE COPY 0 Post Office Box 81 0 Trussville, Alabama 35173 -0081 0 Phone: (205) 655 -3271 Fax: (205) 655 -5112 i e -mail: sales @amerex - fire.com web page: •www.amerex- fire.com 0 No part of this manual may be reproduced or transmitted in any form or an means electrical or 1 P Y Y Y 0 • mechanical, including photocopying or by any storage and retrieval system without the expressed , permission in writing from Amerex Corporation. I ' A Factory Trained and Authorized Distributor must perform the installation and service of any Amerex KP Restaurant Fire Suppression System in strict accordance with this manual.' r I. 1 0. -'' , Prinfpd in U.S.A. Octgber 2003 MM #12385A- 10/2003 • , $ . • 0 110 1P- WO (3611411 0006 1/411000-1/4114-1/4110-4110411WW 1 E - ‘ , _ ,,, .. • .. AMEREX KP RESTAURANT SYSTEM NOZZLE APPLICATION CHART r CI y. m Nozzle P/N Flow Width Length Min. Max. N' A • Points Height Height , ': Deep Fat Fryer - without Drip Pan - 13729 - 2 19 % in 19 in 36 in 48 in. _ Deep Fat Fryer- with Drip Pan 13729 2 19 Y4 in. 25 3/8 in. 36 in. 48 in. Deep Fat Fryer - with Drip Pan Low Proximity 2 -11982 2 1 in. 25 3/8 in. 17 %z in.. 36 in. I. Range - Single Burner 11984 _ Y 18 in. 18 in. 20 in.' . 42'-in. Range - Two Burner 11982 ' 1 14 in. 28 in. 44 in. 48 in. Range -Two Burner 11982 1 . •.12 in. 24 in. 36 in 50 in. - Range - Four Burner 14178 2 24 in. 24 in. 18 in. 50 in. c. Wok 11982 _ 1 14 -24 dia. 4 -7 depth 40 in. 50 in. - 1 _=. Griddle 11982 1 30 in. 36 in.' 30 in. 48 in. _Griddle 13729 2 L 30 in. 42 in 38 in -• 50 in. - Griddle 14178 2 30 in. 48 in: 15 in. - 50`in: , ' - Y � Upright Broiler 2 -11984 1 30 Y in 28 % in a� __ - , 5 Charbroiler (Lava Rock) 11983. 1 Y 24 in," 24, in 18 in 4416• - ', Charbroiler (Gas Radiant & Electric Radiant) 11982 1 24 - in. 24 -in 18 in = 481n.. _:' Natural & Mesquite Charcoal Charbroiler 11983 1 'YZ 24 in.- 28%2 in • 16 in ,' > 42 m `` K - 3 3` g Mesquite Chips & Chunks Charbroiler . : :11.983 ' 1_'/z . i, 24 ins _- 28 Y z in. 16 in 7 - 48(in - `-: Mesqu Log Charbroiler - " - �' ;� •. - � 11983 ^ 1�Yz �24.in_�• _ �28% in.. 19 in. 44:in'` � .r � � - - t'' Flow _ - Length _ _ 1 _, - Plenum ., , N Widt g - PIN - Wi Points , Single BankN -Bank ' i - _ :- `- ',`11982. 1 4 ft. 10 ft. - 0 - Duct - - - Nozz <= Flow Max. Diameter Length Max. 3 ,: - • ;. ` Perimeter Diagonal - v. Rectangular '� . ' . _ ;16416 • ; 1 ' 50 in. - a .. • �• "` . Unlimited .18.8 -in. Circular I Q i �.' : i q 16416 ?' 71` 1 7 - • 16 in Unlimited - - N Rectangular It 1 o c ' ,, is 2.:1 083 - 3 100 in - Unlimited 37.2 in. 8 CirculaF 1-" i E ' ; �;, __ 2- 11983 - ,3 - :32 in Unlimited - D Rectangular ^ r. : tL -: T •`.. 3 -11983 - 4 % - 150 in - Unlimited 55.9 in. P' - CD Circular ', j ; - i ; , o _; . , L. i _ _. C 3-11983 4 Y - - 48 in Unlimited - = 4 ' 01 w r s _ Protection Is not limited to the Item listed.. on this chat Modulizing larger appliances is an acceptable practice. V is ,. ` , See your Amerex KP Manual for additional information. , August. 2004 • Section 3 Design 'Page 3 — 22 • Amerex KP Wet Chemical System (EX 4658). 4 • KP DISTRIBUTION PIPING - 6 DESIGN LIMITS FOR ALL CYLINDER SIZES When designing a KP system to protect a kitchen containing a Fryer, Wok or Range, the following MINIMUM TOTAL SYSTEM PIPING must be used in accordance with the chart below: 6 MINIMUM PIPING REQUIREMENTS 0 • MINIMUM MINIMUM TOTAL MINIMUM FLOW APPLIANCE LINEAR FEET EQUIVALENT FEET POINTS PER SYSTEM Z 6.5 • 10 2 0 cc - • Wok 9 22.1 6 0 ` co 7 16.4. 4 Lb 0 y ° L) SUPPLY LINE LIMITATIONS: 0 A ,.,Ag/ vi All pi .e and fittings running from the distributor block or the discharge fittin • to the first tee. Sj MAXIMUM 0 '' CYLINDER LINEAR FEET MAX.QTY. MAX. QTY. MAX. QTY. 0 N71.1 FLOW POINTS PIPE SIZE OF PIPE TEES ELBOWS BUSHINGS (5 1( ' KP275 = 8 .3/8 . ' 20 1 5 0 KP375 ° = 11 . 3/8 OR 1/2 25 1 5 1 - 0 KP600 = 18 1/2 25 • " . . 1 5, 2 . 0 2 -KP375 = 22 1/2 . 30 2 7 2 ,; NOTE: 1. Use 3/8" supply line only when all piping is to be 3/8" pipe. 2. The supply line has a maximum vertical rise above the distributor of 10 feet. 0 SUPPLY BRANCH LINE (including last nozzle branch) LIMITATIONS: A All pipe and fittings leaving the first splitting tee in the system and ending with the last nozzle in the last branch line. While the last nozzle branch is included in the piping limitations for the supply branch line, the limitation pipe size and maximum length) for nozzle branch lines apply to this portion of the supply branch line. 4 CYLINDER MAX. MAX. MAX. QTY. A FLOW MAX. FEET OF MAX. FEET OF QTY. QTY. REDUCING POINTS PIPE SIZE PIPE STRAIGHT PIPE SPLIT TEES ELBOWS BUSHINGS 0 KP275 = 8 3/8 20 25 • 7 8 0 KP375 = 11 3/8 OR 1/2 27 30 . 10 . 8 2 KP600 = 18 AS NOTED 35' - 3/8" OR 1/2" 50'- 3/8" PIPE ONLY 14 8 . 2 4 2KP375 =22 AS NOTED 40' of 'h" . 45 of 1 /2" 18 8 ' 0 4 *30' of 3/8" ( *30' of 3/8" NOTE: 1. In a single 3.75 Gallon Straight Pipe; System, 5' of pipe may be transferred from the supply line to the supply branch line. . . 0 * 2. The use of 3/8" pipe with two manifold KP375s is only permitted when the SUPPLY LINE length is equal to or less than 20'. NOZZLE BRANCH LINE LIMITATIONS: 0 All pipe and fittings leading from the supply branch tee to a system nozzle. CYLINDER FLOW TOTAL LINEAR MAX. QTY. MAX. QTY. MAX. QTY. POINTS PIPE SIZE FEET OF PIPE TEES ELBOWS BUSHINGS • KP275 = 8 3/8 . 32 ' 5 10 0 0 KP375 = 11 ` . 3/8 OR 1/2 32 8 12 11 , 0 KP600 = 18 ' 3/8 32 11 18 ' 15 2 -KP375 = 22 3/8 32 18 18 ' 20 MAX. PER NOZZLE BRANCH 7 3 6 . 4 GENERAL SYSTEM LIMITATIONS: ' • • . . f 1. No ' /Z" pipe nozzle branches shorter than 12" long. ' � f 2. Nozzle types may not be mixed on any nozzle branch line and a maximum of 4 flow points. 1 /,') '1 A 3. The discharge fitting, distributor and distribution hose are not to be included in any calculations. 4. No mixing of pipe sizes is allowed within pipe categories. Example: if•one nozzle branch is to be 'A" pipe then all 0 ,, :`•.4. 1 must be 'A" pipe. /" pipe for nozzle branch lines is allowed only in. an 11 flow point system. .c.r,,; ='.. 5. Duct nozzle has a maximum vertical rise above the supply branch line of 4'0 ". . 0 r Q ly SN ® • , • October-2003 Section 3 Design Page 3 � - '1 : \ Amerex KP Wet Chemical System (EX 4658) ® GRIDDLE PROTECTION — ® c SINGLE FLOW POINT NOZZLE (P /N 11982) / [. I 6 - The Amerex griddle nozzle (P /N 11982) has one flow ,F , � -± '. (91 cm) _48. � �r � ,; point and will protect a griddle surface of 36 inches r , 0 wide cm). - ( ) x 30 inches deep ( 76 cm ) The nozzle ar melt, .. =<'_ ; -4. ,-,,,. 6 must be located along the perimeter of the appliance ' � A 30° min. • and within a vertical height range from 30" to 48° (76 `��' — 122. cm) above the surface of the appliance. The , aiming point for the nozzle is the °point of intersection" of a straight line from the nozzle location `� to the center of the appliance, with an 11" (28 cm) ® square, generated about the center point of the • 36" max. ill 111quere I griddle. Cam on 4 . of Griddle cent Note: Maximum & minimum. heights must be measured from the tip of nozzle 4 9 , 6 to the surface of the appliance. j j ill QII lP 48" 11" Square Centered . Perimeter of Griddle 1/ 30" • on Griddle Center 1 / ,��� 11" square centered 0 1111111111 on griddle center i • 4 Point 6 Pal of Intersection aM POINT i \ Nozzle Location IS 0 ti ® GRIDDLE PROTECTION — . V tt-.';, MULTIPLE SINGLE FLOW POINT NOZZLES (P /N 11982) 90' max. `- -,,,, ' "` ; - :, `' .. r rt"'; , 0 Multiple Amerex griddle nozzles (P /N 11982 — ,, fi — 3fr one flow point) may be used to protect a griddle -Ai,. ' , • surface area greater than 30 inches (76 cm) X 36 , 0 inches (91 cm). The griddle must be divided into 38° � `� Q ' modules for single nozzle coverage and the / 0 nozzles located and aimed for each module as Tr teas 39 ' r 11•Scere 0 indicated for single nozzle coverage. � , Cantered an ade� ttod�us i 11" square centered .. v on griddle center Perimeter of Griddle ■ /Modules IFNI'��� Note: Maximum & minimum heights \ i i must be measured from the tip of i i 1111511111 nozzle to the surface of the appliance. i i 8" # \ Point of Intersection I zzle Location AIM POINT for nozzle , 11" square centered protecting this module on griddle center y • • i I iL _..rte._ �_ __ t , I October 2003 - Section 3 Design Page .3=10 • i Amerex KP,.Wet,Chemical-System (EX 4658) i 1 • FOUR (4) BURNER RANGE PROTECTION • � i TWO (2) FLOW POINT NOZZLE (P /N 14178) The Amerex 4 burner range nozzle (P /N 14178) has two (2) flow points l ' and will protect a range surface area of 24" x 24" (61 x 61 cm). The center I to center distance between burners must not exceed 12 inches. The - �-• 1 nozzle must be located 18 — 50" (46 -: 127 cm) above the range surface '- and centered between the burners. The nozzle is aimed straight down at ∎�410 i the center of the appliance. I VD° d 1 NOTE: Maximum and minimum I � / heights must be measured from the tip of nozzle to the surface of the appliance. 1 i RANGE PROTECTION — MULTIPLE NOZZLES (P /N i 14178) - For ranges that have a surface area exceeding the capabilities of a single nozzle, multiple nozzles must be used provided that the surface area of the range is divided into equally sized modules. Each module must be equal to or less than 24" x 24" (61 x 61 cm). 7 '. — �` I + y I . NOTE: When using this nozzle to protect a two 50 MAX ♦ ' 4, ■ ` e (2) burner range the aiming point is where an' 4,, - 8.50" radius from the center of each burner (` crosses one another 18 MI * IP O ON '' i ti � 14',.,0 l o d . Syr .... '_ � o re WOK PROTECTION SINGLE FLOW POINT NOZZLE (PIN 11982) i The Amerex appliance plertt p nozzle (P /N 11982) 024- i has one flow point and will protect a wok with ++. dimensions between a minimum diameter of 14" (36 U111. ,i{, I . cm) and a maximum diameter of 24" (61, cm) ii inclusive. The wok must have a height dimension between a minimum of 4" (10 cm) and a maximum of 7" (18 cm) inclusive. The nozzle must be centered . Min. Size over the center of the wok and located at a height Max. Size between 40 " (102 cm) and 50" ( cm) from the . -1 ?gm rmam p bottom of the inside of the wok and aimed at the center of the wok. .. Aim Point . ___ 50" max- ft • . Ne 40" max- i 4 . • • October 2003 Section 3 Design Page 3— 6 . Amerex KP Wet Chemical System (EX 4658) FRYER PROTECTION (FULL VAT) TWO FLOW POINT NOZZLE (P /N 13729) .\-- MAXIMUM 'AREA: 19% in. (50 cm) x 25 -3/8 in. (65 cm) Including drainboard interface area 19% in. (50 cm) x 19 in. (48 cm) not including drainboard interface area The Amerex fryer nozzle (P /N 13729) uses two flow points and will protect a full vat fryer. If the fryer does not include a drainboard, the maximum fryer • dimensions for single nozzle coverage are 19" x 19W (48 x 50 cm) and the • maximum protected area is 2.53 ft (2350 cm If the fryer does contain a • drainboard the maximum fryer dimensions for single nozzle coverage are 25- b S ---1- 8" 3/8" . x 19W (65 x 48 cm) and the maximum protected area is 3.44 •ft (3195 cm However, the maximum hazard area must not exceed 19" x 19 1 I 36° W (48 x 50 cm). The nozzle must be located along or anywhere within the protected area. Nozzle heights must be within 36 to 48 inches (91.44 • WM — 121.92 cm) above the appliance surface and aimed to the center of the . i • hazard area of. the appliance: , $ �, b�aae�bam • Note: Maximum & minimum heights must be 00 � (above droprob°tederoa) �\ fi r measured .vertically from the tip of ;: . ?, nozzle to the top of the appliance. I r AIM POOR J 0 ENT �F HAZARD ARIA) i .•••• � ` O. , # FULL VAT FRYER 93' 38 WITH DRAINBOARD EU i VAT FRYER . WITHOUT DRABOARQ ' M LOW PROXIMITY APPLICATION IC FRYER PROTECTION (FULL VAT) - TWO (2) SINGLE FLOW POINT NOZZLE (P /N 11982) MAXIMUM AREA: 19% In. (50 cm) X 25 3 /8'in. (65 cm) (including drainboard interface area) • 19 in. (50 cm) x 19 in. (48 cm) (not including drainboard interface area) I A pair of Amerex single flow point nozzles FULL VAT FRYER (P /N 11982) will protect a full vat fryer. The WITH DRAINBOARD I nozzles must be used in pairs located on the perimeter of the appliance, 1 /2 " back from the NOZZLE IEO' APART inside edge of the appliance and within a 36" zone extending 6" in both directions of the I center of the hazard. The nozzles are to be . c• located 180° apart (directly across from one • 4 ", 17 vz \ , , 19 h" r another). They are to be aimed at a point 3" '. " below the top of the appliance and directly / below the opposing nozzle. If the fryer does MYING POINT , I not include a drainboard, the maximum fryer ��` � � ; ,,; �;;;` ( dimensions are 19W x 19" (50 x 48 cm) and '.;..1 the maximum protected area is 2.53 ft (2530 I cm 2 ). If the fryer does contain a drainboard, -..-:, I the maximum fryer dimensions are 25 3/8" x 19 12" (65 x 50 cm) and the maximum I protected area is 3.44 ft (3195 cm �,' I 25 -3/8" • However, the maximum hazard area must MAX not exceed 19 1 /2 " x 19" (50 x 48 cm). The 1 nozzle's height must be within 17W to 36" 1 ' • (45 - 92 cm) above the appliance surface. ( 1 ' ( • 1 I 0 • 1 i October 200 Sectioh 3 Design ' Pade 3 =;5 ' Amerex. KP Wet Chemical System (EX 46,58) (,� PLENUM PROTECTION 1 PLENUM PROTECTION LIMITATIONS - 1 SINGLE FLOW POINT NOZZLE (P /N 11982) • i 1 1 The Amerex appliance, plenum nozzle (P /N 11982) is capable of protecting plenums up to 10 feet (3.048m) 0 long with either a single inclined filter bank or a "V" bank filter arrangement. The filter height cannot exceed , .,. 24 inches (60.96 cm). Each plenum nozzle uses one flow point. The nozzle must be positioned 4 inches (10.16) maximum from the wall, aimed horizontally and positioned down 1/3 the filter height from the top of 1 the filter. li "V" Bank Protection Single Bank Protection :1 +/3 FLTER HEIGHT - - � DOWN FROM THE I MD mime FOsER. + ■ . CENTERED MINE 7/3 FILTER HEIGHT 14, ; Y BANK Nr -- r FROM ® ITHETOPOF' THE FILTER. ' "'I ON CENTER •� _ BETWEEN SIDE WALL I L AND FILTER 1 I 40' 0 • 0 / Mil) rol lb 1 �� NOmETI BE 6 l ' ` FROM 6ND WALE lgPy A I NOaLETO BE 111 . . CENTEREDDImE FROM END WALL. Y RAMC - CENTERED ON THE '11,:W FILTER fp h le 10 FT, lif PLENUM PROTECTION — MULTIPLE NOZZLES (3.05m) �. , Plenums exceeding 10 feet (3.048 m) in length may be 10 FT. '" I MP protected by using multiple plenum nozzles. Each nozzle must (3'os ` be protecting an area of no more than 10 feet in length. / i 6 Nozzles may be .positioned facing each other or facing the ill same direction as long as the entire plenum area is being 4,_ covered. Nozzles may not face in opposite directions from a it common tee. -N, IA i \ - - - - . - . iPPI . • Fa - Itfr *7- OP II 10 Y . ' October 2003. - Section 3 Design PageF3} =1 • Amerex KP Wet Chemical :System._ (EX '4658) , 0 1 DUCT PROTECTION • III DUCT PROTECTION LIMITATIONS It SINGLE NOZZLE (P /N 16416) 0 The Amerex duct nozzle (P /N 16416) is listed to protect restaurant cooking ducts of unlimited length up to 50 ✓ perimeter inches (127 cm) or 16 diameter inches (40.6 cm) using one nozzle. The nozzle has one flow point and must be centered within the duct, placed 2 - 8 inches (5.08 - 20.32 into the duct opening and aimed ® at the center of the cross section of the duct. ® NOTE: In no case shall the diagonal ✓ dimension of the duct exceed 18.8 inches . r without additional duct nozzles. 0 OF VERTICAL DUCT � D _ _ • —� O F HORIZONTAL DUCT A AIM POINT 16" D1A. MAX. D D C VERTICAL / HORIZONTAL DUCT. �� ` • TR ' 41 __ Special Note: For ducts with vertical /horizontal transitions reference the diagram above with respect to nozzle aim. 2" 8" ,.., '- TRANSITION LIMITATIONS - SINGLE NOZZLE (P /N 16416) ` ■ A transition is a section found on some exhaust systems between the hood and the duct. One Amerex duct nozzle (P /N 16416) will protect a transition at the point where the transition is 50 perimeter inches (127 cm) or less or a diameter of 16 inches (40.6 cm) or less. The nozzle has one flow point and must be placed in the center of the opening at the point where the perimeter inches are 50 (127 cm) or less or e,....... ' ' where the diameter inches are 16 (40.6 cm) or less and aimed at the center of the cross section on the duct. Additional duct protection is not required when using this method. � UCi ' JC1 N 1 � P N � n �N � ' 1 4 ,M.0010 " it 1 . 41 q a, ) iii _., , . . ,.. „ . , , . , ,. . ,. ..., . ,,,4 Silver Palace Restaurant. • �E 14455 S W Pacific Hwy Tig SeruiceSp� azd,.OR 97224 • . . _ - „a. �.a.�.m+ . (503) 620 -3536 Contractors # 162825 • ' . , 17675 SW Farmington # 118 • . Beaverton, OR 97007 {503} 848 -2345 • ' p,c,: -. _ cxcl y . n; . 4 ._ C H 3e L i,_ ea: - • . {a.l 1 7 1 - ,oh V �V • i _ Silver Palace Restaurant FIRE 14455 S W Pacific Hwy S eruiceSpus Tigard, OR 97224 „ you Safety ,, as h . _ (503) 620 -3536 Contractors # 162825 17675 SW Farmington # 118 Beaverton, OR 97007 {503} 848 -2345 • } `6 air Galia _ _Nie- - - �N , D)_ _ _ _I. o 6 I I ` I _ I I �� oi�1?s .. � N_ou!�S !N �g .,.. f . �/p� l j ,� e f � t e. . , f v� . a �f �J O_ 1 4IN 1�o. ri iq a.:. I 4 , FAN 1 . i_ „ P11r�1 :_ r _1 r r 13 a� ig 1. 801. mss . . V V V a : n _, i , . . . zb Q K \do \ F �r To ,\,\t,. \1 , ._ . , W yk :. w ok .v,l vJQ . � w 7able, - j$ %IA OA la , - /-1-_" - „ .. ,, 2 - 131X