Loading...
Correspondence January 19, 2007 Deffenbaush & Associates Randall Riers 388 State St Suite 840 Salem, OR 97301 RE: GOODWILL INDUSTRIES Project Information Building Permit BUP2006 -00574 Construction Type: V -B Tenant Name: Goodwill Industries Occupancy Type: M /F1 Address: 13920 SW Pacific Hwy Building Area: 1 story, 21,653 sq ft The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition and 2004 Oregon Fire Code as amended by TVF&R. The following information is required in order to complete the review. FIRE LIFE AND SAFETY / GENERAL 1. The structural review was preformed by Miller Consulting Engineers . 2. Provide engineered design information on ceiling, partitions and soffit bracing showing components meet chapter 16 and ASCE 7 -02, or if using a tested and listed system provide framing and construction details along with listing and installation information. OSSC sec.106 3. Occupant count of the Fl appears o conflict with OSSC 1004. Please clarify occupant load and exit access path. OSSC sec. 106 4. Please clarify code section on sheet A0.2, sections noted conflict with current OSSC. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Val Henzel, Senior Plans Examiner January 10, 2007 Miller Consulting Engineers 9570 Barbur Boulevard Portland, OR 97219 RE: PERSONAL SERVICES CONTRACT Project Information Tenant Name: Goodwill Industries Occupancy Type: M Building Permit: Bup2006 -00574 Construction Type: 5B Address: 13920 SW Pacific HWY Stories: 1 To whom it may concern, Please review: the accompanying structural plans for compliance with the Oregon Structural Specialty Code, 2004 edition. Enclosed are full size plan sheets, structural calculations, geotechnical report and a copy of the, permit application. Assess your review fee based on 85% of the structural plan review fee per the Personal Service contract. Structural review fee: $3065.47 Please contact the applicant for review questions and copy the City of Tigard with all correspondence. If you need additional information, please contact me at (503)718 -2759 or E -mail me at m arkva,tigard. or. gov. Respectfully, Mark VanDomelen Plans Examination Supervisor • City of Tigard V t JOB NAME: Goodwill Industries CITY OF TIGARD • JOB ADDRESS: 13920 SW Pacific Hwy., Tigard, OR BUILDING DEPARTMENT DATE: March 13, 2007 13125 HALL BOULEVARD MCE Project No.: 070038 �q \ TIGARD, OR 97223 SHEET 1 OF 3 Tigard Building Permit BUP2006 -00574 STRUCTURAL PLAN REVIEW #4 FILE COPY Plans Dated 2/13/07 Calculations Dated 1/24/07 and 2/12/07 Shop Drawings Corr. Item Page No. Comments Code Section Made No. 2/9/07 1 Sheet A0.3 Clarify other items in reinforcement cell. 2104.1 Concrete Block MSJC 1.15.2 Item 8 2/9/07 2 Sheet A2.1 Clarify location of footings. 106.1.1 Grid 2 & B, C 2/9/07 3 Sheet A2.1 Clarify location of footings 106.1.1 Grid H & 4,5 2/9/07 4 Sheet A2.1 Clarify location of footings 106.1.1 Grid 1 & G, H. 2/9/07 5 Sheet A2.3; south Submit calculations and details for reduced 106.1.1 elevation at entry, west wall section at reveal. elevation, north elevation 4,13,14,16 and 17/A2.4; 4/A11.2 at entry 2/12/07 6 Sheet A2.3 Submit calculations and details for connections 106.1.1 Panel P -20 2/9/07 7 Sheet A2.3 Submit calculations for tie spacing. ACI Chapter 7 2/9/07 8 Details 11/A2.4 Submit calculations and details for 2 - #5 full 106.1.1 And 12/A2.4 height into panel above. 3/13/07 9 Detail 1/A4.3 Submit calculations and details for windows. 106.1.1 (shop drawing) 2/12/07 10 Detail 1,2,3,4,5/A4.4 Submit calculations and details for wall panels. 106.1.1 3/13/07 11 Sheet A5.3 Submit calculations and details for cladding. 106.1.1 (shop drawings) 2/9/07 12 Sheet A7.1 Submit calculations and note detail for support 106.1.1 Grid B to C at grid 1 to of TS 5 x 5 x 1/4 beams. 2 2/12/07 13 Sheet A7.1 Submit calculations and details for support of 106.1.1 Grid E masonry wall. • JOB NAME: Goodwill Industries CITY OF TIGARD JOB ADDRESS: 13920 SW Pacific Hwy., Tigard, OR BUILDING DEPARTMENT DATE: March 13, 2007 13125 HALL BOULEVARD MCE Project No.: 070038 TIGARD, OR 97223 SHEET 2 OF 3 Tigard Building Permit BUP2006 -00574 STRUCTURAL PLAN REVIEW #4 Plans Dated 2/13/07 Calculations Dated 1/24/07 and 2/12/07 Shop Drawings Corr. Item Page No. Comments Code Section Made No. 2/9/07 14 Sheet A7.1 Submit calculations and detail for W14 x 22 at 106.1.1 Grid H and 6 tilt -up wall corner. 2/9/07 15 Sheet A7.1 Clarify detail noted. 106.1.1 Detail 3/A7.2 Grid F to G and 1 to 2 2/9/07 16 Sheet A7.1 Clarify detail noted. 106.1.1 Detail 5/A6.2 Grid 5 and 1 2/9/07 17 Sheet A7.2 Clarify bolt spacing for erection bolts. 106.1.1 Details 4, 13/A7.2 2/9/07 18 Sheet A7.2 Clarify noted HTT and LTT anchor. 106.1.1 Detail 7/A7.2 2/9/07 19 Sheet A7.3 Submit calculations for horizontal loads and 106.1.1 Details 6, 12/A7.3 methods used to transfer loads to foundation. 2/12/07 20 Calculations Submit calculations for roof loads around 106.1.1 L -1 to L -11 raised entry area. 21 Special Inspection Special inspection per sheet A0.3. 1704 Sheet A0.3 1707 2/21/07 22 - General Submit one set of open -web steel joist and (Shop Drawings) girders shop drawings, which have been reviewed and initialed by the project engineer, to be filed with the City of Tigard before placement. 3/13/07 23 General Submit one set of miscellaneous steel shop (Shop Drawings) drawings, which have been reviewed and initialed by the project engineer, to be filed with the City of Tigard before placement. 2/21/07 24 General Submit one set of reinforcing steel shop (Shop Drawings) drawings, which have been reviewed and initialed by the project engineer, to be filed with the City of Tigard before placement. 3/13/07 - - JOB NAME: Goodwill Industries CITY OF TIGARD JOB ADDRESS: 13920 SW Pacific Hwy., Tigard, OR BUILDING DEPARTMENT DATE: March 13, 2007 13125 HALL BOULEVARD MCE Project No.: 070038 TIGARD, OR 97223 SHEET 3 OF 3 Tigard Building Permit BUP2006 -00574 STRUCTURAL PLAN REVIEW #4 Plans Dated 2/13/07 Calculations Dated 1/24/07 and 2112/07 Shop Drawings Corr. Item Page No. Comments Code Section Made No. 2/21/07 25 General Submit one set of steel decking shop drawings, (Shop Drawings) which have been reviewed and initialed by the project engineer, to be filed with the City of Tigard before placement. 26 General Approved resolution of the above items shall be incorporated into submittal plans before a permit will be issued. Submit four (4) sets of revised plans to the City of Tigard. • JOB NAME: Goodwill Industries CITY OF TIGARD ,, JOB ADDRESS: 13920 SW Pacific Hwy., Tigard, OR BUILDING DEPARTMENT DATE: February 21, 2007 13125 HALL BOULEVARD MCE Project No.: 070038 TIGARD, OR 97223 SHEET 1 OF 3 Tigard Building Permit BUP2006 -00574 • STRUCTURAL PLAN REVIEW #3 Plans Dated 2/13/07 Calculations Dated 1/24/07 and 2/12/07 Corr. Item Page No. Comments Code Section Made No. 2/9/07 1 Sheet A0.3 Clarify other items in reinforcement cell. 2104.1 Concrete Block MSJC 1.15.2 Item 8 2/9/07 2 Sheet A2.1 Clarify location of footings. 106.1.1 Grid 2 & B, C 2/9/07 3 Sheet A2.1 Clarify location of footings 106.1.1 Grid H & 4,5 2/9/07 4 Sheet A2.1 Clarify location of footings 106.1.1 Grid 1 & G, H 2/9/07 5 Sheet A2.3; south Submit calculations and details for reduced 106.1.1 elevation at entry, west wall section at reveal. elevation, north elevation 4,13,14,16 and 17/A2.4; 4/A11.2 at entry 2/12/07 6 Sheet A2.3 Submit calculations and d etails for connections 106.1.1 Panel P -20 2/9/07 7 Sheet A2.3 Submit calculations for tie spacing. ACI Chapter 7 2/9/07 8 Details 11/A2.4 Submit calculations and details for 2 - #5 full 106.1.1 And 12/A2.4 height into panel above. 9 Detail 1/A4.3 Submit calculations and details for windows. 106.1.1 (shop drawing) 2/12/07 10 Detail 1,2,3,4,5/A4.4 Submit calculations and details for wall panels. 106.1.1 ?(- 11 Sheet A5.3 Submit calculations and details for cladding. 106.1.1 (shop drawings) 2/9/07 12 Sheet A7.1 Submit calculations and note detail for support 106.1.1 Grid B to C at grid 1 to of TS 5 x 5 x 1/4 beams. 2 2/12/07 13 Sheet A7.1 Submit calculations and details for support of 106.1.1 Grid E masonry wall. JOB NAME: Goodwill Industries CITY OF TIGARD JOB ADDRESS: 13920 SW Pacific Hwy., Tigard, OR BUILDING DEPARTMENT DATE: February 21, 2007 13125 HALL BOULEVARD MCE Project No.: 070038 TIGARD, OR 97223 SHEET 2 OF 3 Tigard Building Permit BUP2006 -00574 STRUCTURAL PLAN REVIEW #3 Plans Dated 2/13/07 Calculations Dated 1/24/07 and 2/12/07 Corr. Item Page No. Comments Code Section Made No. 2/9/07 14 Sheet A7.1 Submit calculations and detail for W14 x 22 at 106.1.1 Grid H and 6 tilt -up wall corner. 2/9/07 15 Sheet A7.1 Clarify detail noted. 106.1.1 Detail 3/A7.2 Grid F to G and 1 to 2 2/9/07 16 Sheet A7.1 Clarify detail noted. 106.1.1 Detail 5/A6.2 Grid 5 and 1 2/9/07 17 Sheet A7.2 Clarify bolt spacing for erection bolts. 106.1.1 Details 4, 13/A7.2 2/9/07 18 Sheet A7.2 Clarify noted HTT and LTT anchor. 106.1.1 Detail 7/A7.2 2/9/07 19 Sheet A7.3 Submit calculations for horizontal loads and 106.1.1 Details 6, 12/A7.3 methods used to transfer loads to foundation. 2/12/07 20 Calculations Submit calculations for roof loads around 106.1.1 L -1 to L -11 raised entry area. 21 Special Inspection Special inspection per sheet A0.3. 1704 Sheet A0.3 1707 2/21/07 22 General Submit one set of open -web steel joist and (Shop Drawings) girders shop drawings, which have been reviewed and initialed by the project engineer, to be filed with the City of Tigard before placement. t c 23 General Submit one set of miscellaneous steel shop (Shop Drawings) drawings, which have been reviewed and initialed by the project engineer, to be filed with the City of Tigard before placement. 2/21/07 24 General Submit one set of reinforcing steel shop (Shop Drawings) drawings, which have been reviewed and initialed by the project engineer, to be filed with the City of Tigard before placement. NOTE: Reinforcing steel for footings and slab only. JOB NAME: Goodwill Industries CITY OF TIGARD JOB ADDRESS: 13920 SW Pacific Hwy., Tigard, OR BUILDING DEPARTMENT DATE: February 21, 2007 13125 HALL BOULEVARD MCE Project No.: 070038 TIGARD, OR 97223 SHEET 3 OF 3 Tigard Building Permit BUP2006 -00574 STRUCTURAL PLAN REVIEW #3 Plans Dated 2/13/07 Calculations Dated 1/24/07 and 2/12/07 Corr. Item Page No. Comments Code Section Made No. 2/21/07 25 General Submit one set of steel decking shop drawings, (Shop Drawings) which have been reviewed and initialed by the project engineer, to be filed with the City of Tigard before placement. 26 General Approved resolution of the above items shall (Shop Drawings) be incorporated into submittal plans before a permit will be issued. Submit four (4) sets of revised plans to the City of Tigard.