Correspondence • ` b; khy,4 April 16, 2004 CITY OF TIGARD OREGON Martin D. Sommers Sommers Enterprises PO Box 21086 Keizer, OR 97307 RE: MECHANICAL EQUIPMENT @ AUTO QUICKLUBE Project Information Building Permit: MEC2003 -00713 Construction Type: VN Tenant Name: Quicklube Occupancy Type: B /S3 Address: 13545 SW Pacific Highway Occupant Load: 17 Area: 3799 Sq Ft Stories: 1 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2002 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99- 01) 1999 edition. The submitted plans are approved subject to the following. Special Inspection: Special inspection is required for Epoxy Bolts and Structural Welding. The special inspection agency of record shall furnish inspection reports to the Engineer of Record, Havlin G. Kemp, the General Contractor, Sommers Enterprises. and the City of Tigard, Building Division, attention Hap Watkins. All discrepancies shall be . brought to the immediate attention of the general contractor for correction. The special inspector shall submit a final signed report stating whether the work requiring special • inspection was, to the best of the inspector's knowledge, in conformance with the approved plans and specifications and the applicable workmanship provisions of the Oregon Structural Specialty Code, Section 1701.3. 1. Ductwork shall be supported in accordance with Sheet Metal & Air Conditioning Contractors National Association, Inc. (SMACNA) 2. Each appliance shall be provided with a shutoff valve separate from the appliance. The shutoff valve shall be located in the same room and within six feet of the appliance served. Access shall be provided to the shutoff valve. C409.5 OMSC 3. Equipment and appliances regulated by this code requiring electrical connections shall have a positive means of disconnect in accordance with the Electrical Code. 301.7 OMSC • 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 - J 4. Appliances serving different areas of a building other than where they are installed shall be permanently marked in an approved manner that uniquely identifies the appliance and the area it serves. 304.10 OMSC 5. Condensate from cooling coils or evaporators shall be collected and discharged to an approved plumbing fixture or disposal area. 307.1 OMSC 6. Smoke detectors shall be installed in return air systems with a design capacity greater than 2000 cfm. Upon activation, the smoke detector shall shut down the air distribution system. Smoke detectors shall be connected to a fire alarm system and shall activate an audible and visible alarm at a constantly attended location. 606.2, 606.4 & 606.4.1 OMSC 7. Appliances shall be accessible for inspection, service, repair or replacement without . removal of permanent construction. 306.1 OMSC 8. Manufacturer's installation instructions shall be available on the jobsite at the time of inspection. 304.1 OMSC Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC • When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and .. ssing the documents. Respe ma . Jock Se »Plans Examiner AI Sommers Enterprises Distributors of Shenandoah Waste Oil Furnaces PO Box 21086 — Keizer, Oregon 97307 PH: 503 - 393 - 5315 Fax: 503 �+ Toll Free 1- 866 - 373 -HEAT RECEIVED To: Brian Blalock/ City of Tigard APR a d 2004 From: Brian Pfaff/ Sommers Enterprises CITY OF TIGARD RE: Tigard Quick Lube, Mechanical Equipment BUILDING DIVISION Building Permit #: MEC2003 -00713 In reply to: Letter from January 2, 2004 concerning plan review. (Attached letter) Please find enclosed all information/drawings required for you review for the issuance of the mechanical Permits. 1. Structural calculations and details for attachment/anchorage of roof mounted AC -1 attached. 2. We have eliminated all appliances on the roof within 10 feet of roof edge, so no guard will be necessary. Please refer to revised drawings submitted. 3. Details and calculations for the structural support of unit F -1 attached. A second unit (F -2) has been added to revised drawings. A second structural support will be installed for this second unit (F -2). The details and calculations apply to both structural supports. Please refer to revised drawings submitted. 4. Detail 1/M2 has been revised and supmitted. Please refer to revised drawings submitted. 5. Equipment cut sheets are attached. ( yjf f torivsrf (ft -oz) — c rr $Nm, 713 fr -v' 6. Valuation for the project: $17,725.00 Sing= ely, J n P ff Sommers nterprises