Plans r 1 /3/37 J /✓ac s y •cam /�9' q oa
' 338 - ROOF COVERING MATERIALS'
(T ROOF COVERING MATERIALS (TENT) t
ROOFING' SYSTEMS (TGFU) Continued ROOFING SYSTEMS (TGFU) — Continued
Top Coat "Thermo Super Prep" at 2 gal/sq. Surfacing: Texas Refinery Corp. "Aluminum Roof Coating" , 1 gal/sq.
Surfacing (Optional): No. 11 ceramic granules, embedded into wet top 7. Deck: C -15/32 Indine: 1/2
coating, 50 lb /sq. Existing Roof System: Class A asphalt glass fiber felt, smooth surfaced
2. Deck: NC Indine: 4 or gravel surfaced (gravel may be removed). Covered with:
Foam: "Thermo RS ", nom 1 -2 in. thick. Base Sheet: Type G2, mechanically fastened or adhered with hot roofing
Surfacing" Two coats "Super Prep II/TRS Topcoat" at 1 - 1 -1/2 gal/sq asphalt.
each coat. Mem vane: "TP-4" or "TP -4G" (modified bitumen), heat fused.
3. Deck: NC Incline: 3 Suri. 'ng: Karnak Chemical Corp. "Karnak No. 97 Fibrated Aluminum
Foam: Bustin Urethane "BUC 124 -3" or Urethane Contractors Supply & Asphalt Roof Coating ", 1 -1/2 gal/sq or Grundy Industries "al -MB Aluminum
Consulting "SBS II 3.0 ", 1 - 1 1/2 in. nom thickness. Roof Coating ", at 1 -1/2 gal/sq.
Surfacing: Two coats "Super Prep II/TRS Topcoat" at 1 - 1 -1/2 gal/sq
each coat. THOMAS K CHAFFEE CO R8763 (N)
4. Deck: NC Indine: 2 80 S BROW ST, EAST PROVIDENCE RI 02914
Foam: "Thermo RS ", 1 -2 in thick.
Base Coat "Thermo 202HS" at 1 -1/2 - 2 gal/sq. COLD APPLICATION SYSTEMS
Surfacing: "Super Prep II/TRS Topcoat" at 1 =2 gal/sq. Class B
1. D
5. Deck: NC Deck: C -15 32
Incline: 2 Base 3 layers T ype 15 asphalt organic - or asbestos felt base
B Sheets: Incline: 1 -1/2
Foam: IP Inc "1070", Stepan "9300 Series", Polythane "5200- 25/30 ", c
nom 1 -1/2 in. thick. sheet applied with cold cement "Fibrelast Roof Adhesive" at 1 gal/sq/layer.
•
Base Coat in. this at 1 -2 gal/sq. Surfacing: Glass fibered coating "Glastic Roof Resurfaces", 2 -1/2 gal/sq.
Surfacing: "Super Prep II", IRS Topcoat" at 1-2 gal/sq. No. 11 roofing granules embedded in wet coating at 60 lb /sq.
6. Deck: NC Incline: 3 COMBINATION NOT AND COLD SYSTEMS
Foam: IP Inc. "1070 ", Stepan "9300 Series" or Polythane "S200- 25/30 ", Class A
• nom 1 -1/2 in. thick. 1. Deck: C -15/32 Indine: 1
Surfacing: Two coats "Super Prep II/TRS Topcoat" at 1 -2 gal/sq/coat. Insulation: Perlite, 1 in. min, sprinkle mopped or mechanically fastened.
7. Deck NC Incline: 2 Ply Sheets: 4 layers Type 15 tar organic felt, hot mopped; followed by a
Foam: Burtin Corp. "BUC 124 -3 ", Stepan "9300 Series ", Polythane flood coat of hot roofing coal tar pitch.
"5200 - 25/30", 1 to 3 in. thick. Coating: 1 coat tar fibered coating "Fibrelast Roof Resurfacer TB" at 5 -7
Surfacing: Two coats "Super Prep II"/"TRS Topcoat" at 1 -2 gal/sq/coat. gal/sq.
Class B Surfacing: Gravel, at 400 lb /sq, embedded in wet coating.
1. Deck: C -1 2' • 2. Deck: C -15/32 Incline: 1
/ Incline: 1 Insulation: Perlite, 1 in. min, sprinkle mopped or mechanically fastened.
'Joints of plywood deck are caulked with "Super Prep II/TRS Coating" and
covered with Manniglas 1200 strips, 0.050 in. thick min. b y y Sheets: 4 layer Type 15 asphalt organic felt, hot mopped; followed
Foam: "Thermo RS ", 1 -1/2 in. nom . thickness by a flood coat of hot roofing asphalt
Surfacin .T wo coats. "Su er Pre II /TRS Topcoat" at 1 - 1 -1/2 Coating: 1 coat asphalt fibered coating "Fibrelast Roof Resurfacer 470
g' p p gal/sq LMP" at 5 -7 gal/sq.
each coat. Surfacing: Gravel, at 400 lb /sq, embedded in wet coating.
MAINTENANCE AND REPAIR SYSTEMS
Class A TOZAI ASPHALT ROOFING CONTRACTOR'S ASSOCIATION R9876 (N)
1. Deck C -15/32 Indine: 1 3 -11 -13 IWAMOTO -CHO CHIYODA -KU, TOKYO JAPAN
Existing Roof System: Class A, existing gravel must be maintained,
covered with: SINGLE PLY MEMBRANE SYSTEMS
Base Sheet (Optional): "Thermo -Glas Base, mechanically fastened. Class B —Fully Adhered
Ply Sheet Two plies "Thermo Polyester", applied with "Thermo #202 ", 1. Deck C-15/32 Incline: 1/2
3 -1/2 gal /sq/ply. Membrane: "Gumlon Base". (self- adhering modified bitumen).
Coating: "Thermo #202 ", 3 gal/sq. Surfacing: "Gumlon Cap" (self- adhering modified bitumen).
Surfacing: "Thermo Super Prep ", 2 gal/sq. '
2. Deck: NC Indine: 1 TREMCO INC R6692 (N)
Existing Roof System: Class A, B or C, covered with: 10701 SHAKER BLVD, CLEVELAND OH 44104
Base Sheet (Optional): "Thermo -Glas Base ", mechanically fastened. Mess otherwise indicated, the specified insulations may be used in
Ply Sheet Two plies "Thermo Polyester", applied with "Thermo #202 ", combination. Insulations may be mechanically attached, adhered with hot
3 -1/2 gal/sq/ply. roofing asphalt, "Thermastic", "Premium III" asphalt, "Premium IV" asphalt,
Coating: "Thermo #202, 3 gal/sq. Tremco Insulation Adhesive or FAS -N -FREE. Polytherm ply sheet may be
Surfacing: "Thermo Super Prep ", 2 gal/sq. replaced with Type G2 "Base Sheet" or Type G2 "BURmastic Glass Ply". '
3. Deck: NC Indine: No Limitation The insulation specified may be replaced with cellular concrete or lightweight
Existing Roof System: Class A, B or C BUR, covered with: concrete, 2 in. min or Pittsburgh Coming's "Foamglas", 1 in. min. For systems
Base Sheet Optional): One or more layers "Thermo Polyester", applied not utilizing a base sheet, a min 28 lb Type G2 base sheet shall be mechanically
with 3 -4 ga o Thermolastic 202 HS ". • red to the concrete b - . re e eu ' . . . ' •
Ply Sheet (Optional): One or more layers "Thermo Polyester", applied Unless of ensue indicated, "Premium III" asphalt, "Premium IV" asphalt or
with 3-4 gal/sq/pl of " er more 202 HS ". hot roofing asphalt may be used in place of "Thermastic". For systems where
Coating: "Thermolastic 202 HS" at 3 -5 gal/sq. insulations are "optional ", base a . bo o 1 " heets may i - mechanicall
Surfacing: "Thermolastic Super Prep II" or "Solar Shield" at 2-3-gal/sq. ry eney. Aloptional Rosin shee Type G2 base shee i : I 'mastic omposi e
4. Deck: NC Incline: Unlimited Ply" .
a added undemeat e required ply sheets. "Thermglass Plus" may
Insulation: UL Classified sprayed polyurethane foam, any thickness. be replaced by any UL Classified Type G1 ply sheet. "BURmastic Glass Pl or
Unless
Membrane: "202HS" at 4 gal/sq. Applied in 2 coats of 2 gal/sq/coat. sheet sh on n nc buit i le y' may be replaced by any UL Classified Type G2 base
Base Coat�"202H5" at 2 gal/sq with fine gravel, spread over wet coating Unless t ed, i only.
at 150 lb /sq. otherwise indicated, nsulation may be optional for all systems on
Surfacing: "Thermo Compound/Thermo #101 Concentrate" coating, mixed noncombustible decks only.
50 lb dry mix, 5 gal water and 1/2 gal concentrate. Applied at one sq per Unle otherwise indicated, G2 ply sheets may be replaced by Gl ply sheet for
s s ms
batch. all systems on noncombustible decks using Thermastic.
5. Deck C -15/32 Incline: 1 For the Cold Application System, the base ply may also be fully adhered with
Insulation: UL Classified sprayed polyurethane foam, an thickness. "Thermasti t o " Tremco Insulation Adhesive ". "BURmastic Glass Ply" may be
laced Membrane: "202HS" at 4 gal/sq. Applied in 2 coats of 2 gal/sq/coat re "Premium II "," Premium IV" or hot roofing asphalt may be used in place of
Base Coat"202H5" at 2 gal/sq with fine gravel, spread over wet coating "Thermastic". 150 lb/sq.
Unless otherwise indicated, joints in insulation must be offset 6 in. from
Surfacing: 'Thermo Compound/Thermo #101 Concentrate" coating, mixed joints in deck for combustible systems.
50 lb dry mix, 5 gal water and 1/2 gal concentrate. Applied at one sq per "BURmastic LV" is an acceptable alternate for "BURmastic".
batch. "Polarcote" and "Double Duty Aluminum LV" are acceptable alternates for
6. Deck: NC Indine: 1/4 "Double Duty Aluminum ".
Existing Roof Covering System: Class A, B or C. "Thermastic 50" and "Thermastic 100" are acceptable alternates for
Membrane: "TP-4" or "TP4G" (modified bitumen). "Thermastic".
LOOK FOR MARK ON PRODUCT
e .- - : s.
A �
Y
ROOF COVERING MATERIALS (TEVT) ROOF COVERING MATERIALS (TEVT) 339
I
, ROOFING SYSTEMS (TGF'U)— Continued ROOFING SYSTEMS (TGFU) — Continued
C "Tremprime WB" is an acceptable alternate for "Tremprime OD ". Surfacing: Gravel or slag.
Unless otherwise indicated, 1/2 in. to 1 in. thick wood fiber may be used over 9. Deck: C -3/4 Incline: 3
d polyisocyanurate insulation on noncombustible decks only. Insulation (Optional): Any UL Classified perlite, polyisocyanurate or
Unless otherwise indicated, crushed stone, nom 3/64 -3/8 in. at min 240 glass fiber, 3/4 in. min.
1 lb S. • : te. . • r - .o .1 . .. . ....I! ossification Ply Sheet: Three or more plies "Ply Type IV or VI" (Type G1), "G -2 or G -33
" colastic" and gravel (or crushed stone, nom 3/64 -3/8 in. at mm. 240 Base" (Type G2), adhered with hot roofing asphalt.
.s sq) may replace "BURmastic" and gravel in all systems. Surfacing: Gravel or crushed stone, 400 lbs /sq or crushed slag, 300
r • 1 min gyps' • .. • • 1 min) Georgia -Pacific lbs /sq, applied in a flood coat of hot roofing asphalt.
r "Dens -Deck ®" overlayment board may be used in any existing noncombustible 10. Deck: NC Incline: 1
deck Classification. When this is done, the resulting roofing system is Insulation (Optional): Any UL Classified perlite, polyisocyanurate or
acceptable for use over combustible (15/32 in. min) roof decks. The joints in glass fiber, 3/4 in. min.
i the gypsum board and overlayment board are offset 6 in. with the joints in the Ply Sheet: Three or more plies "Ply Type IV or VI" (Type G1), "G -2 or G -33
deck. Base" (Type G2), adhered with hot roofing asphalt.
"MB Composite Base Sheet" may replace "BURmastic Composite Ply" in any Cap Sheet: One ply "G -3 Cap ", adhered with hot roofing asphalt.
• Classification. 11. Deck: C -15/32 - Incline: 1/2
. "MB Glass Base Sheet" may replace "BURmastic Glass Pl or "BURmastic Insulation: Urethane, fiberglas or polyisocyanurate, 3 in. min covered
Composite Ply" in any Classification. with 1/2 in. thick wood fiber or perlite.
"Therm MB 2C6S" may replace "Therm MB 2C60" in any Classification. Ply Sheet: Two plies "Polytherm ", adhered with "Thermastic".
•
" Tremlastic S" may replace " Tremlastic" in any Classification. Ply Sheet: Two or more plies Type G1 "Thermglass Plus ", adhered with
' Type G2 "BURmastic 28 lb Base Sheet" may replace "BURmastic Glass Ply" or " Thermastic".
"BURmastic Composite Ply" in any Classification. Surfacing: Gravel, applied in a flood coat of " Thermastic".
"Trisotech G" or "Tapered Trisotech" may be used in any Classification which Class B
1 references the use of polyisocyanurate insulation. "Trisotech GP" and "Tapered 1. Deck: C -15/32 Incline: 1/4
i s Trisotech GP" may also be used in any Classification which references the use Insulation: Wood fiber or perlite 1 to 3 in. thick.
of polyisocyanurate insulation and, in addition, may be used in any Classi- Ply Sheet: Three or more plies Type G3 " Thermglas Plus ", adhered with
I fication which requires a • mineral or wood fiberboard coverboard over " Thermastic".
.i. polyisocyanurate insulation. These latter two products need no separate Surfacing: Gravel, applied in a flood coat of " Thermastic".
coverboard. 2. Deck: C -15/32 Incline: 1/4
ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Insulation: Glass fiber, perlite, urethane or polyisocyanurate, 1 -3 in.
-« Unless otherwise indicated, "BURmastic Composite Pl may be added as an thick, covered with 3/4 to 1 in. thick wood fiber.
optional base sheet to the following systems. Ply Sheet: Three or more plies Type G1 " Thermglas Plus", adhered with
Class A " Thermastic".
✓ 1. Deck: NC Incline: 3 Surfacing: Gravel, applied in a flood coat of " Thermastic".
Insulation (Optional): Urethane or polyisocyanurate, any thickness 3. Deck: C -15/32 Incline: 1/4 (see note)
covered with 1/2 to 1 in. thick wood fiber; wood fiber, perlite or glass Insulation: Glass fiber, perlite or wood fiber, 1 in. min; polyisocyanurate
'C fiber, any thickness. or polyurethane, 1 in. min, covered with 1/2 to 1 in. thick wood fiber.
? ; Ply Sheet Three or more plies Type Gi " Thermglas Plus ", adhered with Ply Sheet Three or more plies "Polythene ", adhered with " Thermastic".
" Thermastic". Surfacing: Gravel, applied into a flood coat of " Thermastic".
Surfacing: Gravel, applied in a flood coat of "Thermastic". Note: When glass fiber insulation is utilized, the incline may be
2. Deck: C -15/32 Incline: 1/2 /'' increased to 1/2 in. /ft.
Insulation: Urethane, fiberglas or polyisocyanurate, 1 in. min covered / 4. Deck: C -3/4 Incline: 3/4
with 3/4 to 1 in. thick wood fiber or perlite. Insulation (Optional): Any UL Classified perlite, polyisocyanurate or
Ply Sheet Three or more plies Type G1 " Thermglas Plus ", adhered with • glass fiber, 3/4 in. min.
"Thermastic". 1 Ply Sheet: Two or more plies "Ply Type IV or VI" (Type G1), "G -2 or G -33
Surfacing: Gravel, applied in a flood coat of " Thermastic". Base" (Type G2), adhered with hot roofing asphalt.
3. Deck: NC Incline: 3 . Cap Sheet: One ply "G -3 Cap ", adhered with hot roofing asphalt.
• Insulatfon(Optlonal): Glass fiber, perlite or wood fiber, unlimited Class C
thickness; polyisocyanurate or polyurethane, unlimited thickness, covered 1. Deck: C -15/32 Incline: 1/4
with 1/2 to 1 in. thick wood fiber. Insulation: Wood fiber, perlite, fiberglas, urethane or polyisocyanurate,
• Ply sheet Three or more plies "Polytherm ", adhered with "Thermastic". 1 to 3 in. thick, covered with 3/4 to 1 in. thick wood fiber.
Surfacing: Gravel, applied in a flood coat of "Thermastic". Ply Sheet: Three or more plies Type GS " Thermglas Plus ", adhered with
4. Deck: C -15/32 Incline: 1/4 "Thermastic".
Barrier Board: Gypsum board, 1/2 in. min. Surfacing: No. 11 Roofing granules, 60 lbs /sq, applied in a flood coat of
Insulation (Optional): 1 in. min wood fiber, glass fiber, perlite, - "Thermastic".
polyisocyanurate, covered with 1/2 to 1 in. wood fiber. 2. Deck: C -15/32 Incline: 1/4
Ply Sheet Three or more plies of "Polytherm ", adhered with "Thermastic". Insulation (Optional): Glass fiber, perlite or wood fiber, 3 -1/4 in. max;
Surfacing: Gravel, applied in a flood coat of " Thermastic". polyisocyanurate or polyurethane, covered with 1/2 to 1 in. thick wood
5. Deck: C -15/32 Incline: 1/4 fiber (3 -1/4 in. total).
Barrier Board: Gypsum board, 1/2 in. min. Ply Sheet: Three or more plies "Polythenm ", adhered with " Thermastic".
Insulation (Optional): Wood fiber, glass fiber, perlite, 1 in. max. Surfacing: No. 11 roofing granules, 60 lbs /sq, into flood coat of
Ply Sheet Three or more plies of "Polytherm ", adhered with " Thermastic". " Thermastic".
Suating: "Double Duty t Aluminum" coating 4 to 5 g3 / 3/4 g a
Surfacing: COAL TAR FELT SYSTEMS WITH HOT ROOFING COAL TAR PITCH
: "Double ty Alnum" coating at 34 gl/sq.
6. Deck: NC Incline: 1/4 Class A, B or C
Insulation (Optional): Wood fiber, glass fiber, perlite, 1 in. max. Hot roofing coal tar pitch, "ThermTar", for use with asphalt organic felts,
Ply Sheet Three or more plies of "Polytherm ", adhered with "Thermastic". asphalt reinforcements, coal tar organic felts or coal tar glass reinforcement ply
Coating: "Tremlastic" or "Tremlastic S ", 4 to 5 gal/sq. sheet systems.
Surfacing: "Double Duty Aluminum" coating at 3/4 gal /sq. COLD APPLICATION SYSTEMS
7. Deck: NC Incline: 1 -1/2 Class A
Insulation: Wood fiber, glass fiber, perlite or polyisocyanurate, 3 in. Unless otherwise indicated, the "Glassply" layers are adhered with Tremco
max. "BURmastic" at 2 -1/2 to 3 -1/2 gal/sq. The "Composite Ply" layers are adhered
Ply Sheet Three or more plies Type G1 ply sheet, adhered with with "BURmastic" at 2 to 3 gal/sq. As an alternate, the ply sheets may be
" Thermastic. adhered with "Thermastic", "Premium III" asphalt, "Premium IV" asphalt or hot
Coating: "Tremlastic", 4 to 5 gal/sq. roofing asphalt. A ply sheet may be replaced with one of more plies of Type G2.
Surfacing: Two coats "Polarcote FR ", 1 gal/sq /coat. 1. Deck: C -15/32 Incline: 2
8. Deck: C -15/32 Incline: 3 Insulation: Wood fiber, glass fiber or polyisocyanurate 1/2 to 1 -5/8 in.
Insulation (Optional): Pertite or glass fiber, 3/4 in. max or wood fiber, Ply Sheet: Three or more layers Type G2 "BURmastic Glass Pl
1 in. max. Coating: "BURmastic", 5 to 6 -1/2 gal/sq.
Base Sheet (Optional): Rosin. Surfacing: Gravel applied into wet coating.
Base Sheet 'Type G2 BURmastic Glass Ply". 2. Deck: NC Incline: 1 -1/2
Ply Sheet Two or more plies Type GI "Thermglass Plus ", adhered with Insulation: Wood fiber, glass fiber, perlite or polyisocyanurate, 3 in.
" Thermastic". max.
LOOK FOR MARK ON PRODUCT
r . . --
340 " . ROOF COVERING MATERIALS (TEVT) ROOF COVERING MATERIALS (TEVT)
ROOFING SYSTEMS (TGFU) - Continued ROOFING SYSTEMS (TGFU)- Continued
Ply Sheet Three or more Layers Type G2 "BURmastic Glass Ply." Ply Sheet Four or more plies "BURmastic Composite Ply."
Coating: " Tremlastic" pr " Tremlastic S ", 4 to 5 gal/sq. Coating: "BURmastic", 5 to 6 - 1/2 gal/sq.
Surfacing: Two coats "Polarcote FR ", 1 gal/sq /coat. Surfacing: Gravel, 500 lb /sq applied into wet coating. 30.
3. Deck: C -15/32 Incline: 1 17. Deck: NC Incline: 1/2 •
Insulation: Perlite, glass fiber or polyisocyanurate, 1 to 3 in. Insulation: Wood fiber, glass fiber, polyisocyanurate, 1 to 3 in.
Ply Sheet Three or more plies Type G2 "BURmastic Glass Ply'. Ply Sheet Three or more plies "BURmastic Composite Ply."
Coating: " Tremlastic", 4 to 5 gal/sq. Coating: "Tremlastic" or "Tremlastic S ", 4 to 5 gal /sq. .
Surfacing: Two coats "Polarcote FR ", 1 gal /sq coat. Surfacing: No. 11 roofing granules, 60 lb /sq.
4. Deck: C -15/32 Incline: 1/8 18. Deck: C -15/32 Incline: 1/6
Insulation (Optional): Wood fiber, glass fiber, perlite or polyisocyanurate, Insulation (Optional): Glass fiber, polyisocyanurate or polyurethane, 31.
any thickness. unlimited thickness.
Base Sheet (Optional): One ply Rosin or one ply Type G2. Base Sheet (Optional): 1 ply Rosin and /or 1 ply Type G2.
Ply Sheet: Four or more plies Type G2 "BURmastic Glass Ply ". Ply Sheet: Four or more plies "BURmastic Composite Ply".
Coating: "BURmastic", 5 to 6 -1/2 gal/sq. Coating: "BURmastic", 5 to 6 -1/2 gal/sq.
Surfacing: Gravel. 500 lbs /sq, applied into wet coating. Surfacing: Gravel, 500 lb /sq, applied into wet coating.
5. Deck: NC Incline: 1/2 19. Deck: NC Incline: 1/2 32.
Insulation: Wood fiber, glass fiber, polyisocyanurate or perlite, 3 in. Insulation (Optional): Glass fiber, wood fiber, polyurethane or
max. polyisocyanurate, 1/2 to 1 -5/8 in.
Ply Sheet: Three or more plies Type G2 "BURmastic Glass Ply". Ply Sheet: Three or more plies "BURmastic Composite Ply."
Coating: "Tremlastic" or " Tremlastic S ", 4 to 5 gal/sq. Coating: "Tremlastic" or " Tremlastic S ", 4 to 5 gal /sq.
Surfacing: No. 11 roofing granules, 60 lbs. /sq. Surfacing: "Double Duty Aluminum" coating at 3/4 gal/sq.
6. Deck: C -15/32 Incline: 1/2 20. Deck: NC Incline: 1/4
Insulation : Polyisocyanurate, 1 to 3 in. Insulation (Optional): Glass fiber, wood fiber, polyurethane or
Insulation (Optional): Perlite, 3/4 in. min. polyisocyanurate, 2 in. max. 33.
Ply Sheet: Three or more plies Type G2 "BURmastic Glass Ply". Ply Sheet: Three or more plies "BURmastic Composite Ply."
Coating: " Tremlastic" or " Tremlastic S ", 4 to 5 gal/sq. Coating: "Tremlastic" or " Tremlastic S ", 4 to 5 gal/sq.
Surfacing: No. 11 roofing granules, 60 lbs /sq. Surfacing: "Double Duty Aluminum" coating at 3/4 gal/sq.
7. Deck: NC Incline: 1/2 21. Deck: C -15/32 Incline: 1/4
Surfacing: "Liqui -Mat", 6 gal/sq. Insulation: Polyisocyanurate, 1 in. min.
8. Deck: C -15/32 Incline: 1/6 Ply Sheet: Three or more plies "BURmastic Composite Ply."
Insulation (Optional): Glass fiber, polyisocyanurate or polyurethane. Coating: "BURmastic", 5 to 6 -1/2 gal/sq.
Base Sheet (Optional): One ply rosin or one ply Type G2. Surfacing: Gravel applied into wet coating.
Ply Sheet: Four or more plies Type G2 "BURmastic Glass Pl , 22. Deck: NC Indine: 1/2
Coating: "BURmastic", 5 to 6 -1/2 gal/sq. Insulation: Polyisocyanurate, wood fiber, glass fiber, 2 in. max. 34.
Surfacing: Gravel 500 lb /sq, applied into wet coating. Base Sheet: One or more plies Type G2 adhered with "Thermastic".
9. Deck: NC - Indine: 1/2 Ply Sheet: Two or more plies "BURmastic Composite Ply".
Insulation (Optional): Glass fiber, wood fiber, polyurethane or Surfacing: "BURmastic", 5 to 6 -1/2 gal/sq .and graveL
polyisocyanurate, 1/2 to 1 -5/8 in. 23. Deck: C -15/32 Indine: 1/4
Ply Sheet: Three or more plies Type G2 "BURmastic Glass Ply". Base Sheet: One ply type G2 or "Burmastic Composite Ply", mechanically
Coating: " Tremlastic" or " Tremlastic S ", 4 to 5 gaL/sq. fastened. 35.
Surfacing: "Double Duty Aluminum" coating at 3/4 gal/sq. Insulation (Optional): Glass fiber or wood fiber, unlimited thickness;
10. Deck: NC Incline: 1/4 polyisocyanurate, any thickness, covered with 1/2 in. wood fiber.
Insulation (Optional): Glass fiber, wood fiber polyurethane or Ply Sheet: Three or more plies Type G2 "BURmastic Glass Ply".
polyisocyanurate, 2 in max. Coating: "BURmastic FR", 3 -1/2 gal/sq.
Ply Sheet: Three or more plies Type G2 "BURmastic Glass Ply". Surfacing: No. 11 Roofing Granules, 60 lbs/square.
Coating: " Tremlastic" or "Tremlastic 5 ", 4 to 5 gal/sq. 24. Deck: NC Incline: 1/4
Surfacing: "Double Duty Aluminum" coating at 3/4 gal/sq. Insulation: Polyisocyanurate, 2.3 in. max, covered with wood fiber, 1 in.
11. Deck: C -15/32 Incline: 1/8 max; glass fiber or wood fiber, any thickness.
Insulation (Optional): Glass fiber, polyisocyanurate or polyurethane, 2 Base Sheet: One ply G2, mechanically fastened or adhered with
in. max. , "Thermastic".
Base sheet (Optional): One ply Rosin or one ply Type G2. Ply Sheet: Two or more plies Type G2 "BURmastic Glassply" or "BURmastic
Ply Sheet: Three or more plies Type G2 "BURmastic Glass Ply ". Composite Ply".
Coating: " Tremlastic" or "Tremlastic S ", 4 to 5 gal/sq. Coating: " Tremlastic" or " Tremlastic S ", 4 to 5 gal/sq. 36 .
Surfacing: "Double Duty Aluminum" coating at 3/4 gal/sq or 2 coats of Surfacing: "Double Duty Aluminum Coating" at 3/4 gal/sq. c
"Polarcote FR" at 1 gal/sq/coat. 25. Deck: NC Incline: 3/4
12. Deck: C -15/32 Incline: 1/8 Insulation: Polyisocyanurate, unlimited thickness.
Insulation (Optional): Glass fiber, polyisocyanurate or polyurethane, Ply Sheet: Three or more plies Type G2 "BURmastic Glass Ply".
3 -1/4 in. max. Coating: "BURmastic", at 5 to 6 -1/2 gal/sq.
Base Sheet (Optional): One ply Rosin or one ply Type G2. Surfacing: Gravel applied into wet coating.
Ply Sheet Four or more plies Type G2 "BURmastic Glass Ply". 26. Deck: NC Incline: 1/2
Coating: "Tremlastic" or "Tremlastic 5", 4 to 5 gal/sq. Insulation: Wood fiber, glass fiber perlite or polyisocyanurate, unlimited 37.
Surfacing: "Double Duty Aluminum" coating at 3/4 gal/sq. thickness.
13. Deck: C -15/32 Incline: 1/4 Ply Sheet: Three or more layers of Type G2 "BURmastic Glass Pl
Insulation: Polyisocyanurate or glass fiber, unlimited thickness. Coating: " Tremlastic" or " Tremlastic 5 ", 4 to 5 gal /sq.
Ply Sheet: Three or more plies Type G2 "BURmastic Glass Ply'. Surfacing: Two coats "Polarcote FR ", 1 gal/sq/coat.
Coating: "BURmastic", 5 to 6 -1/2 gal/sq. 27. Deck: C -15/32 Incline: 1
Surfacing: Gravel applied into wet coating. Insulation: Perlite, glass fiber or polyisocyanurate, 1 to 3 in.
14. Deck: C -15/32 Incline: 2 Insulation (Optional): Wood fiber, 1 in. max. 38.
Insulation: Wood fiber, glass fiber, polyisocyanurate, 1/2 to 1 -5/8 in. Ply Sheet: Three or more plies Type G2 "BURmastic Glass Ply".
Ply Sheet: Three or more plies "BURmastic Composite Ply." Coating: " Tremlastic" or " Tremlastic 5 ", 4 to 5 gal /sq.
Coating: "BURmastic" at 5 to 6 -1/2 gal/sq. Surfacng: Two coats "Polarcote FR ", 1 gal/sq/coat.
Surfacing: Gravel applied into wet coating. 28. Deck: C -15/32 Incline: 1/2
15. Deck: NC Indine: 1 -1/2 Base Sheet: One ply Type G2 "BURmastic Glass Ply", mechanically
Insulation: Wood fiber, glass fiber, perlite or polyisocyanurate, 3 in. fastened.
max. Ply Sheet: Three or more plies Type G2 "Burmatic Glass Pl 39.
Ply Sheet: Three or more plies "BURmastic Composite Ply." Coating: " Tremlastic" or 'Tremlastic S ", 4 to 5 gal/sq.
Coating: " Tremlastic" or "Tremlastic S ", 4 to 5 gal/sq. .- _, Surfacing: Two coats "Polarcote ", 1 gal/sq/coat.
Surfacing: Two coats "Polarcote FR ", 1 gal/sq/coat 29 Deck: NC Incline: 3'
16. Deck: C -15/32 Incline: 1/8 Insulation: Polyisocyanurate, 1 -1/2 in. max, covered with 1/2 in. wood
Insulation (Optional): Wood fiber, glass fiber, perlite or polyisocyanurate, fiber; glass fiber or wood fiber, 2 in. max.
unlimited thickness. Ply Sheet: Three or more layers Type G2 "BURmastic Glass Ply".
Base Sheet (Optional): 1 ply Rosin and /or 1 ply Type G2. Coating: "BURmastic", 4 -1/2 to 5 -1/2 gal/sq. 40.
LOOK FOR MARK ON PRODUCT
.. i ROOF' COVERING MATERIALS (TEVT) ROOF COVERING MATERIALS (TEVT) 341
T „
ROOFING SYSTEMS (TGFU)— Continued ROOFING SYSTEMS (TGFU)— Continued
. , Surfacing: Crushed stone, nom 3/64 to 3/8 in., at min 240 Ibs /sq, Insulation: Polyisocyanurate, any thickness, covered with 1/2 in. wood
applied into wet coating. fiber.
30. Deck: NC Iodine: 4 Ply Sheet Three or more plies "BURmastic Composite Ply.
Primer: "Tremprime WB ". Coating: "BURmastic", 5 to 6 -1/2 gal/sq.
Base Coat "Tremlastic" or " Tremlastic 5' at 2 to 3 gal/sq. Surfacing: Gravel applied into wet coating.
s Ply Sheet: One or more plies of polyester fabric (not weighing more than Class B
1.6 lbs /sq), adhered with " Tremlastic" at 2 to 3 gal /sq. 1. Deck: C -15/32 Incline: 1/8
Top Coat " Tremlastic" or " Tremlastic 5' at 3 to 4 gal/sq. Insulation: Glass fiber, polyisocyanurate or polyurethane, 1 in. min.
Surfacing: Two coats of "Polarcote FR', 1 gal/sq /coat. Ply Sheet Three or more plies "BURmastic Composite Ply."
31. Deck: NC Indine: 1/4 Coating: ' Tremlastic" or " Tremlastic S ", 4 to 5 gal/sq.
Insulation: Wood fiber, glass fiber, petite or polyisocyanurate, unlimited Surfacing: "Double Duty Aluminum" coating at 3/4 gal/sq.
thickness. 2. Deck NC Incline: 1/2
Ply Sheet Two or more plies Type G2 "BURmastic Glass Ply". Insulation (Optional): Polyisocyanurate, glass fiber or wood fiber, 1 -1/2
j Coating: " Tremlastic" or " Tremlastic 5', 4 to 5 gal/sq. in. max.
k Surfacing: Two coats, "Polarcote °, 1 gal/sq/coat. Ply Sheet: Three or more plies Type G2 "BURmastic Glass Ply".
' 32. Deck C -15/32 Iodine: 1/2 Coating: "BURmastic FR", 3 -1/2 gal/sq.
Insulation (Optional): Glass fiber, polyisocyanurate or polyurethane, Surfacing: No. 11 Roofin. Granules, 60 lbs
r unlimited thickness. COMBINATION HOT AND COLD SYSTEMS
Base Sheet (Optional): One ply Rosin and /or 'one ply Type G2.
t Unless otherwise indicated, the base and bottom ply sheets may be
Ply Sheet Four or more plies "BURmastic Composite Ply'. mechanically fastened. Subsequent ,l s . . re adhered with "Therma
, . Coating: BURmastic", 5 to 6 -1/2 gal/sq.
I Surfacing: Crushed stone, nominal 3/64 to 3/8 in. at min 240 lbs /sq, 1 Deck: NC .�. •
ne: 2
applied into wet coating. , Insulation: Wood fiber pe i e or glass fiber, 1 in. max.
- 33. Deck: C -15/32 - Incline: Unlimited Base Sheet: Type 15 base sheet.
Vapor Barrier: One ply of rosin paper, mechanically fastened. Ply Sheet: Two or more plies Type 15.
Base Sheet: One ply "BURmastic Composite 'Ply", mechanically fastened. Coating: Glaze coat of hot,roofing asphalt.
Ply Sheet: Two 'plies "BURmastic Composite Ply", adhered with "Brirmastic' Coating: "Penefelt", 5 gal/sq or "Ecolastic", 9 gal /sq.
at 1 to 2 gal/sq. Surfacing: Gravel, applied into wet coating. •
' Coating: " Tremlastic" or " Tremlastic S' at `2 gal/sq with 150 lb /sq of 2. Deck: NC Incline: 1/4
■ crushed granite into wet coating. Insulation (Optional): Wood fiber, perlite , • or glass fiber, 2 in. max;
Surfacing: Neste Thermo's Thermo Compound/Thermo ij101 Concentrate" polyisocyanurate, 1 in., covered with 1/2 in. wood fiber.
coating, mixed 50 lb dry mix, 5 gal water and 1/2 gal concentrate, • Ply Sheet: Two or more plies Type G1 ply sheet.
applied at one sq/batch. .- Primer (Optional): "Tremprime QD", 1/8 gal/sq.
• 34. Deck: NC Iodine: 1/2
Coating: " Tremlastic" or " Tremlastic 5 ", 4 to 5 gal/sq.
.; . Base Sheet: One ply "BURmastic Composite Ply", mechanically fastened. Surfacing: "Double Duty Aluminum" coating, 3/4 gal/sq.
Ply Sheet Two plies "BURmastic Composite Ply", adhered with "BURmastic" 3. Deck NC Iodine: 2 -
*. ; at 1 to 2 gal/sq. Insulation (Optional): Wood fiber, petite, or glass.fiber, 2 in: max.
Coating: " Tremlastic" or " Tremlastic 5' at 4.to 5 gal/sq. Ply Sheet: Two or more plies Type Gl ply sheet.
• Surfacing: Two coats "Polarcote', 1 gal/sq/coat. Coating: "BURmastic",•.5 to 6 -1/2 gal/sq.
35. ,Deck: C -15/32 Incline: Unlimited Surfacing: Gravel applied into wet coating.
a ` ' Slip Sheet (Optional): One ply rosin, mechanically fastened. 4. Deck NC Iodine: 1
-- Insulation (Optional): Polyisocyanurate, wood fiber, urethane, perlite or Insulation: Glass fiber, wood fiber, perlite or composite, 2 -1/4 in. max.
glass fiber, any thickness. Ply Sheet Three or more plies Type Gi ply sheet.
. Barrier Board: Georgia Pacific "Dens -Deck ®", 1/4 in. thick, mechanically Coating: "BURmastic", 5 to 6 -1/2 gal/sq.
y " fastened.
urfadng: Gravel applied into wet coating.
.n Insulation (Optional): Polyisocyanurate, wood fiber, urethane, perlite or 4 . / , • C -15/32 • Indine: 1/2 :
glass fiber, any thickness. li / Insulation: Glass fiber or isocyanurate, 1/2 to 3 in.; 1 -1/2 in. perlite.
Ply Sheets: Three or more plies of "BURmastic Glass Ply" or "BURmastic -- Ply Sheet Three or more plies Type Gi Ply Sheet
Composite Ply', adhered with "BURmastic". Coating: BURmastic", 5 to 6-1/2 a
i Coating: " Tremlastic" or " Tremlastic S" at 4 to 5 gal/sq. •dg: applied into wet oattiingr " Tremla 4 to 5 gal/sq.
•- Su Two coats "Polarcote FR", 1 gal/sq/coat .. Deck NC Iodine: 1/4
36. Deck: C -15/32 Incline: 4 -1/2 Insulation (Optional): Wood fiber, perlite, glass fiber 3 in. max.
Insulation (Optional): Polyisocyanurate, glass fiber, wood fiber or Ply Sheet: Two or more plies of Type GS adhered with "Thermastic".
perlite, any thickness. Primer (Optional): 'Tremprime QD", 1/8 gal/sq.
Base Sheet: One ply "Therm MB LTD", inverted and mechanically fastened. Coating: "Tremlastik" or " Tremlastic S ", 4 to 5 gal/sq. -
s Ply Sheet: Three or more plies Type G2, 'BURmastic Composite Ply' or Surfacing: Two coats "Polarcote FR ", 1 gal/sq/coat.
"BURmastic Glass Ply', adhered with BURmastic". 7. Deck: NC Incline: 1/4
Coating: "Tremlastic" or " Tremlastic 5', 4 to 5 gal/sq. Insulation: Polyisocyanurate, 2.3 in. 'max, covered with 1/2 wood fiber;
Surfacing: Two coats "Firekote ", 1 gal/sq/coat. wood fiber or glass fiber, 2.3 in. max.
37. Deck: NC incline: 3 Base Sheet: One ply G2 adhered with hot roofing asphalt.
Insulation: Wood fiber, ,glass fiber, perlite or polyisocyanurate, 3 in. Ply Sheet: Two or more plies Type G2 adhered with "BURmastic' at 2 -1/2 •
max. to 3 -1/2 gal/sq.
Ply Sheet: Three or more plies Type G2 'BURmastic Glass Ply." Coating: " Tremlastic" or " Tremlastic S ", 4 to 5 gal/sq.
Coating: " Tremlastic", 4 to 5 gal/sq. Surfacing: "Double Duty Aluminum Coating" at 3/4 gal/sq.
s '3? Surfacing: Two coats "Polarcote FR ", 1 gal/sq/coat
( Deck: C -15/32 Indine: 1/2
' Surfacing: "Polarcote ", 1 gal/sq. � Base Sheet: One ply rosin, mechanically fastened.
a '' 38. Deck: NC 'Indine: 2 -1/2� Base Sheet: One ply Type G2, mechanically fastened.
s _j` In (Optional): Glass fiber, wood fiber', polyurethane or Ply sheet: Three or more plies Type G1 ply sheet adhered with
polyisocyanurate, any thickness. " Themmastic".
Ply Sheet: Three or more plies Type G2 "BURmastic Glass Ply or Coating: "BURmastic", 4 to 5 gal/sq.
j •• ;;. "BURmastic Composite Ply', adhered with "BURmastic". Surfacing: GraveL
Coating: " Tremlastic', 4 to 5 gal/sq• 9. Deck: C -15/32 • Indine: 1/2
' Surfacing: "Double Duty Aluminum ", 3/4 gal/sq. Base Sheet: One ply rosin, mechanically fastened.
•°' 39. Deck: NC • Indine: 5 Base Sheet: One ply Type G -2, mechanically fastened.
, ' Insulation (Optional): Glass fiber, wood fiber, polyurethane or Ply Sheet: Three or more plies Type GOne ply sheet adhered with
i- polyisocyanurate, any thickness. "Thermastic".
Ply Sheet: Three or more plies Type G2 "BURmastic Glass Pl or Coating: "BURmastic", 4 to 5 gal/sq.
"BURmastic Composite Pl adhered with "BURmastic". Surfacing: GraveL
l , Coating: " Tremlastic', .4 to 5 gal/sq. 10. Deck: NC Incline: 1
Surfacing: Two coats "Polarcote FR ", 1 gal/sq/coat Insulation: Polyisocyanurate, 1.2 in. max.
i , 40. Deck: C -15/32 Indine: 1/4• Insulation (Optional): Wood fiber overlay, 1 in. max.
LOOK FOR MARK ON PRODUCT •
•