Plans /3 / Product 38YCC (60 Hz) Carrier` Data 10 SEER Heat Pump ® HEATING & COOLING 38YCC Sizes 018 thru 060 The 38YCC Outdoor Section of Split- System Heat Pumps is designed for quiet, reliable heating during the winter and cooling during the summer. With SEER ratings up to 11.5 and HSPF from 6.8 to 7.6, this heat pump system provides economy of operation through energy conservation when used with components designated by the manufacturer. The 38YCC recovers ' _ heat for indoor comfort from outdoor air � - during the heating season and, by automatically reversing the refrigerant system, removes indoor heat and excess I humidity during the cooling season. r - -- All models are listed with UL (U.S. and Canada), CEC, and ARI. I I III FEATURES I •. • I (( Electrical Range — All sizes of the I II I 38YCC are offered in single phase 208- I I (I 230v. The 38YCC 030 through 060 I I I I ( models are offered in 208/230v 3 phase and 38YCC 036 through 060 are offered I I Ili in 460v 3 phase. I I Size Range — The 38YCC is available in 7 nominal sizes from 018 through 060 I I I 1 to meet the needs of residential and light I I commercial applications. Compressor — Designed specifically I for heat pump duty, with energy I I ( efficiency during heating and cooling operation. Each compressor is hermetically sealed against contamination to assure long life and dependable performance; compressors are also externally mounted on rubber isolators for quiet operation. For improved serviceability, all models are equipped with a compressor terminal plug. Continuous compressor operation is approved down to -30 °F (- 34.4 °C) in the heating mode, and down to 55 °F Copyright 2004 Carrier Corporation Form 38YCC -8PD • Physical data UNIT SIZE . ' • • 018 024 030 036 042 ' .048 060 1 • SERIES 34/35 34/35 34/35, 52 33, 56, 66/ 34, 57, 67/ 32, 56, 66/ 32, 56, 66/ 34, 55, 65 36, 59, 69 34, 57, 67 34, 57, 67 OPERATING WT (Lb) 127 143 157/153 185/176 197/195 219 237 COMPRESSOR Scroll Type Reciprocating Reciprocating Scroll REFRIGERANT R -22 Control Piston Charge (Lb) @ 15 ft 4.25/4.69 I 4.63/4.75 I 5.19/5.63 6.38 1 7.88 9.25/9.38 I 10.25/10.50 CONDENSER FAN Propeller Type, Direct Drive Air Discharge Vertical Air Oty (CFM) 1700 I 1700 2500 3000 3000 3300 3300 Motor HP 1/12 1/12 1 Motor RPM (60 Hz) 1100 1100 I 11 5 11 I 11 11 I 11 CONDENSER COIL Fins o per In. Ft) 9. 9.11 I 12.42 14.8 I 18.5 22.40 I 2 550 Circu I CONNECTION (In. ID) Sweat (38YCC) Vapor 5/8 I 5/8 I 3/4 3/4 I 7/8 7/8 I 7/8 Liquid . 3/8 REFRIGERANT TUBES* (In. OD) Vapor (0-50 Ft Tube Length) 5/8 5/8 3/4 3/4 7/8 7/8 1 -1/8 Vapor (Max Diameter for Long -Line Applications) 3/4 I 3/4 I 7/8 7/8 I 1 -1/8 1 -1/8 I 1 -1/8 L iquid (0-50 Ft Tube Length) 3/8 L iquid (For Long -Line Applications) • Tube sizes are for lengths up to 50 ft. For lengths over 50 ft horizontal and/or 20 ft vertical differential, consult Long -Line Application Guideline. NOTE: See unit Installation Instructions for proper Installation. METERING DEVICE UNIT OUTDOOR INDOOR SIZE SERIES PISTON PISTON* 018 34/35 42/40 55/52 024. 34, 35 • 49 63 030, . 34, 35, 52 55 70 036. 33, 56, 66 61 76 036 • V 34, 55, 65 57 70 042 34, 36, 57, 59, 67, 69 63 78 048 32, 56, 66/34, 57, 67 73/70 88/86 1 060 - 32, 34, 56, 57, 66, 67 76 96 'Piston listed is for any approved coil combination. CHARGING SUBCOOLING (TXV -TYPE EXPANSION DEVICE) UNIT ' REQUIRED SIZE- SERIES SUBCOOLING ( °F) 018-34/35 , 12/14 I - 024 -34/35 12/10 •. - 030 -35/52 12/8 L 036{33, 36, 66) 12 - 036{34,55,65) - . , ° 14 042 16 . 048 -32, 56, 66/34, 57, 67 10/15 060 10 3 Y.t A so 3 AIR DISCHARGE ...6--- M --al AIR IN AIR DISCHARGE . : I Y # FIELD POWER SUPPLY CONN N . I //// 7 /3 -IN. DIA HOLE WITH O //// /�/ = `O — -- 14B -IN. DIA KNOCKOUT mom I "I AND 1 3 /8 -IN. DIA 0 . N ` ' ■ - ` � /� � `! `` KNOCKOUT r. , ,> i % J K 'ti ■ Fl ELD CONTROL SUPPLY N / �L �• ♦ 1 1 AIR IN CONN T/ - 1N. DIA AIR � � / ^ s -- - ' L ��■ e I 3 /8 -IN. IN D---'1'.1A 1111�� \ \ \tf;+��Jllll�'�llll B ittI HOLE . %. � /1 � 1I 3 W TIEDOWN �� . `......./'' �� t' iiy '-„ KNOCKOUTS N.' ♦ i !B -IN. DIA LIOUIO � � \ . (2) PLACES ' ■ I LINE CONN ' ` 0 I V I 1113111111. c. � C7 AIR DISCHARGE E I + 2 � /8 AIR IN _ I F D DIA VAPOR LINE CONN 1 G NOTES: H 1. Allow 30 in. clearance to service side of unit, 48 In. above unit, 6 in. on one side, 12 In. on remaining side, and 24 in. between units for proper airflow. . 2. Minimum outdoor operating ambient In cooling mode Is 55 °F (unless low ambient control is used) max. 125 °F. 3. Maximum outdoor operating ambient in heating mode is 66 °F. 4. Series designation is the 13th position of the unit model number. 5. Center of gravity B. A97045 , i DIMENSIONS (IN.) MOUNTING t . UNIT SIZE, Series Cnera rIsrtetlee A B C D E F G H J K L M N P PAD (Square) 38YCC018' 4, 5 1 Phase 22 -1/2 25-15/16 3 -3/16 5/8 3 -11/16 18-1/8 19-3/4 21.5/8 14-3/8 18 -7/8 22 -1/16 11 5 12 22 -1/2" 38YCCO24'_ 4, 5 1 Phase 22 -1/2 25 -15/16 3.3/16 5/8 3.11/16 18-1/8 19-3/4 21.5/8 14-3/8 18-7/8 22 -1/16 10 5 13 22 -1/2" i 38YCCO30 2 3 Phase 22 -1/2 33 -15/16 3- 3/16 3/4 3 -11/16 18-1/8 19-3/4 21.5/8 14-3/8 18-7/8 22 -1/16 12 -1/2 12 14 22 -1/2" 38YCCO3ol. 5 1 Phase 22 -1/2 33-15/16 3 -3/16 3/4 3 -11/16 18-1/8 19-3/4 21.5/8 14-3/8 18 -7/8 22 -1/16 12 -1/2 12 14 22 -1/2" 38YCCO36 : 3, 4 1 Phase 30 27- 15/16 3 -3/16 3/4 • 6-1/2 23-1/2 27 -1/4 29-1/8 20 26-3/8 29-9/16 16-3/4 . 15 12 30" ( 38Y.CCO36: 5, 8 3 Phase 30 27 -15/16 3- 3/16 3/4 6 -1/2 23-1/2 27 -1/4 29-1/8 20 26-3/8 29 -9/16 16-3/4 15 12 30" 38YCC042.; 4 1 Phase 30 33 -15/16 3 -1/4 7/8 6-1/2 23-1/2 27 -1/4 29-1/8 20 26-3/8 29 -9/16 15 15-3/4 13 -1/2 30" i- 38.Y,CC042• 6 1 Phase 30 31- 15/16 3-1/4 7/8 6.12 23-1/2 27 -1/4 29-1/8 20 26-3/8 29-9/16 15 15-3/4 13 -1/2 _ 30" 381',CC042; 7, 9 3 Phase 30 33 -15/16 3 -1/4 7/8 6-1/2 23-1/2 27 -1/4 29-1/8 20 26-3/8 29-9/16 15 15-3/4 13-1/2 30" 38YCC048'1 2, 4 1 Phase 30 39 -15/16 - 3 -1/4 • 7/8 6-1/2 23-1/2 27 -1/4 29-1/8 20 26-3/8 29-9/16 15 15-3/4 15-1/2 30" (:38YCC048 8, 7 3 Phase 30 39 -15/16 3 -1/4 7/8 6-1/2 23-1/2 27 -1/4 29-1/8 20 26-3/8 29-9/16 15 15-3/4 15-1/2 30" ( 38YCC060 2, 4 1 Phase 30 ' 39 -15/16 3 -1/4 7/8 6-1/2 23-1/2 , 27 -1/4 29.1/8 20 26-3/8 29 -9/16 13-3/4 15-5/8 15 30" 38YCC060 6, 7 3 Phase 30 39- 15/16 3-1/4 7/8 6-1/2 23-1/2 27 -1/4 29-1/8 20 26-3/8 29.9/16 13 -3/4 15-5/8 15 30"