Loading...
Permit CITY OF TIGARD BUILDING PERMIT PERMIT #: BUP1999 -00486 .r DEVELOPMENT SERVICES DATE ISSUED: 11/29/99 r� 13125 SW Hall Blvd., Tigard, OR 97223 (503) 60 , . V ;. 1 SITE ADDRESS: 13050 SW PACIFIC HWY /G PARCEL: 2S102CB -02700 SUBDIVISION: FREWINGS ORCHARD TRACTS V// ZONING: C -G BLOCK: LOT: 020 /� RISDICTION: TIG REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: FPS FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 5N : sf N: S: E: W: OCCUPANCY GRP: B TOTAL AREA: sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 900.00 Remarks: Pyro chem kitchen hood system Owner: Contractor: ANTHONY CAPONE UNIVERSAL FIRE EQUIPMENT 13056 SW PACIFIC HWY 8049 SW CIRRUS DR TIGARD, OR 97223 BEAVERTON, OR 97008 Phone: 503 - 624 -6300 Phone: 641 -8702 Reg #: uC 86723 FEES REQUIRED INSPECTIONS Type By Date Amount Receipt Sprinkler Rough -In PRMT BON 11/18/99 $50.00 99- 319753 Sprinkler Final 5PCT BON 11/18/99 $4.00 99- 319753 FIRE DEB 11/29/99 $20.00 99- 320037 Total $74.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set fort 'n OAR 952 - 001 -0010 through OAR 952 - 001 -1987. You may obtain a copy of these rules or direc • -stions to OUNC by calling (503) 246 -1987. • Permitee _ Sig nat e: - ■ 1�- _ V Issue y: ! :GI , // . // i Call 63• -4175 by 7 p.m. for an inspection the next business day Fire Protection Permit Application Plan Check# - 4 CITY OF TIGARD Commercial or Residential Rec'd By 13125 SW HALL BLVD. Date Rec'd — .Z TIGARD, OR 97223 Print or Type Date to P.E. I : ' (503) 639 -4171, x. 304 Incomplete or illegible applications will not be accepted Date to DS ' -! Permit # N i Called 11 ' _q Job N. r e of Development/Project Type of System (Complete A or B as applicable) Address Addoss A.) Sprinkler Wet ❑ Dry ❑ ..1D 6 sLi, z ,9c1 Name Standpipes Owner Mailing • .dress Hazard Group 4. .. -L., Additional City/State Zip Phone Information Density IIEIINWIAOPM- - - oar . E' in Design Area �J Occupant Mailing Address K. Factor City/State Zip Phone A.1) Sprinkler Project Valuation $ Contractor Name B.) Fire Alarm (Sprinkler or a!, I V Pif 5 1 F e v F J u; p ol7� , C_., Alarm Company) Mailing Address ' Submittal Shall Include Battery Calculations YES ❑ Prior to permit We ' S C % rr D r. issuance, a City/State Zip Phone Individual Component YES ❑ copy r Cut Sheets of all licenses ✓i 0 4 ej 7c& 6 c0 -S' 7 0 Z. B.1) Fire Alarm Project Valuation $ are required if State Const. Cont. Board Lic.# Exp. Date expired in COT G Project Valuation Subtotal (A & or B) $ c� database O �7Z / // Name Permit fee based on valuation $ (see chart on back) 7c) Architect Mailing Address • �/o Surcharge $ 4 City/State Zip Phone FLS Plan Review 40% of Permit $ Describe work A.) New a''''—Addition 0 Alteration 0 Repair 0 TOTAL $ to be done: B.) Modification to sprinkler heads only: 1. 1 -10 heads= No plans required Plans required: Submit three sets of plans, including a vicinity map and 2. 11 += Plan review required the location of the nearest hydrant. I hereby acknowledge that I have read this application, that the information given is Number of sprinkler heads: correct, that I am the owner or authorized agent of the owner, and that plans submitted Additional Description of Work: are in compliance with Oregon State laws. P ro GA � €4.1 /i p s 3 t Signature of Owner/At - Date A.) In Existing Building TA ew Building ❑ ..iiM ` �� `/ -/ Z - `� `j Building 4 co tact Per pn arge 77 _ Z Data B.) Commercial IA Residential ❑ 29 t e Zv FOR OFFICE USE ONLY: No. of stories: Plat # Map/TL #: / Sq. Ft: - Notes Occupancy Class Type of Construction • is \dsts\fonns \firesupr.doc 7/2/99 12/09/1999 Activities for Case #: BUP1999 -00486 9:56:06 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes BUPC100 (F) Issue permit 11/29/1999 DEB DONE No Hold DEB 11/29/1999 BUPC005 Application received 11/12/1999 GEO RECD No Hold BON 11/18/1999 BUPC008 Permit created 11/18/1999 BON DONE No Hold BON 11/18/1999 BUPC012 Plans routed to Plans Examiner 11/18/1999 BON DONE No Hold BON 11/18/1999 ' BUPCO24 Plans Approved by CPE 11/19/1999 RDP DONE No Hold RDP 11/19/1999 BUPCO22 Plans Approved /Routed to DSTs 11/19/1999 RDP DONE No Hold RDP 11/19/1999 BUPC783 Sprinkler Rough -In 11/19/1999 11/19/1999 11/30/1999 TLP PASS No Hold TLP 12/01/1999 BUPC784 Sprinkler Final 11/19/1999 11/19/1999 11/30/1999 TLP PASS No Hold TLP 12/01/1999 BUPCO29 DST Post Review Completed 11/19/1999 BON DONE No Hold BON 11/19/1999 BUPC090 (F) Ready to issue 11/19/1999 BON DONE No Hold BON 11/19/1999 BUPA950 Case Finaled 12/09/1999 JMT DONE No Hold JMT 12/09/1999 Page 1 of 1 I Sanchez Taquer 11" x 14" exhaust HL-02 Duct T 1- tk— \ ---1 FL-A Pyro Chem PCL-240 UL -300 fire system I I I 1 Max. Flow Points 8 Heat Detection System Using 7 System Piped in 318" Black Pipe 1 6' Hood Chem Fuel Shut Off 314" Gas PCL -240 HL-11112 HL-R NL -R Valve i eV \ 1=> �� \\ Pull Station 5' on path \ of egress CITY OF TIGARD 0 Approved 3/4 " Gas Value Conditionally Approved pproved ( ); For only the work as described in: 4 Burner 36"grilltop PERMIT NO. &Pig- 90c's,( stove top Universal Fire Equipment Sanchez Taqueria See Letter to: Follow [ j: 8049 SW Cirrus Or. 13050 SW Pacific Hwy Attach ( j: Beaverton, OR 97008 Tigard, Or. 97223 Job Address: 1 ■vsb S�..J P. . L u CCB 1 56723 (503) 598.3487 By: 2 Date: to hi 191 (503) 641 -8702 Lupe Sanchez Greg Heath • ■