Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Correspondence (9)
• . City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 August 22, 2008 RE: ISSUANCE OF SITE PERMIT T I GARD Project Information Project Name: Burgerville Construction Type: 5B Building Permit: BUP2008 -00244 Occupancy Type: A -2 Address: 12785 SW Pacific Hwy. Occupant Load: 80 Alan Armstrong, The Building Division has completed the review of the project listed above. The project has not been released by either the Planning Division or the Engineering Division at the time of this letter, so the Building Permit cannot be issued. If you have questions please contact Maris Buxton © 503 - 718 - 2453. The date of this letter begins the 180 day time limitation in accordance with Section 105.3.2 of the State of Oregon, Structural Specialty Code, 2007 'edition. If the permit has not been issued within the time limitations referenced in section 105.3.2, the work shall be considered abandoned, and the - plans will be expired. • Respectfully, i an Nelson Senior Plans Examiner (503)718 -2436 • dann @tigard -or.gov • Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 • j d white 6ERGERI Englneers Inc. Land Use Planning • Natural Resources • Public Involvement August 18, 2008 Dan Nelson Senior Plans Examiner • City of Tigard • 13125 SW Hall Boulevard Tigard, Oregon 97223 Re: Plan Revisions for Burgerville (BUP2008- 00244) JDW Project #VAJDW- 08-301 Dear Mr. Nelson: On August 5, 2008, we received your letter outlining the results of the plan review for the above - referenced permit. The City's comments regarding the original plans are below (in italicized font). They are followed by how the issue has been addressed in the revised plan set. 1) Construction requirements for suspended ceiling systems are found in the Oregon Building Codes Division website under Statewide Code Interpretations dated 4/20/2007. (see interpretations(structural) at www.bcd.oregon.gov) The code is now referenced on the plans which are consistent with the applicable standards. Drawings 4 and 6 on sheet A 504 indicate the proposed method. 2) A public facilities improvement permit is required for overflow infiltration basin. A public facilities improvement permit is being provided as part of today's submittal. A narrative regarding the overflow infiltration basin is provided as part of the revised plan set. 3) Please provide complete code summary for this tenant improvement. The complete code summary for the proposed improvement is included on sheet A 001 of the revised plan set. 4) Provide details for blocking, strap, and attachment for drag strap at roof. Details regarding blocking, drag strap, and attachment for the drag strap to the roof are included on sheet S 102. 5) A site permit is required for this project. A site permit application was provided on August 11, 2008 and was assigned Case # SIT2008- 00017. 6) Provide details of rear exit door showing door opener at gate. • 1111 Main Street • Suite 300 • Vancouver, Washington 98660 • Ph: 360.823.6100 • Fax: 360.823.6101 • www.jdwhite.com 700 NE Multnomah Street • Suite 900 • Portland. Oreaon 97232 • Ph: 503.872.4100 • Fax: 503.872.4101 • 11 Mr. Dan Nelson • Re: Plan Revisions for Burgerville (BI P2008- 00244) August 18, 2008 Page 2 The rear exit door swing was changed and panic hardware is indicated on sheet A 103 in the revised plan set. 7) An electrical permit and plan review will be required for this project. A separate electrical permit and plans will be submitted at a later date as a deferred submittal. 8) A site utilities permit is required for this project. A site utilities permit has or will be provided prior to issuance of the building permit. 9) Please provide design for seismic attachment of cistern. The design for the seismic attachment of the cistern is indicated on sheets S 101 and S 102 on the revised plan set. In addition, the attached letter of August 13, 2008 from Catena Consulting Engineers contains additional information. 10) Provide roof design and calculations for seismic and vertical loads from new HVAC Roof Pac's. Details regarding roof design and calculations for seismic and vertical loads from new HVAC roof pac are included in the revised plan set at sheet S 102 and in the revised structural details and calculations attached. 11) Provide construction details for connection of 5 1/8x12 GLB to 8x8 HSS column. Construction details regarding connection of 5 1/8x12 GLB to 8x8 HSS column are included in the revised plan set at sheet S 505. As indicated above, we have addressed or will address all of the items listed in the August 5, 2008 plan review letter. In addition, the lighting energy form is attached. If you have any questions or need additional information, please contact Alan Armstrong at 503.731.5909. Thank you for your assistance. Sincerely, CEi2 / ck- ao Fool Brian Carrico, AICP Senior Planner C: Alan Armstrong Attachments: One original wet - stamped set and two copies of revised building plans PFI permit and narrative August 13, 2008 letter from Catena Consulting Engineers regarding structural plan check comments Lighting energy form • • .. City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 August 5, 2008 U RE: TENANT IMPROVEMENT T I GARD Project Information Building Permit: BUP2008 -00244 Construction Type: 5 -B Address: 12785 SW Pacific Hwy. Occupancy Type: A -2 Area: 2860 Sq. Ft. Stories: 1 Name: Burgerville Sprinklers: No The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2007 edition; 2007 Oregon Fire Code. Please respond to conditions below. 1) Construction requirements for suspended ceiling systems are found in the Oregon Building Codes Division website Statewide Code Interpretations dated 4/20/2007. (see interpretations {structural} at www.bcd.oreion.gov) 2) A Public Facilities 'Improvement Permit is required for overflow infiltration basin. • 3) Please provide complete code summary for this tenant improvement. 4) Provide details for-=blocking, strap, and attachment for drag strap at roof. 5) A Site Permit is required for this project. 6) Provide details of rear exit door showing door opener at gate. 7) An Electrical Permit and Plan 'Review will be required for this project. 8) A Site Utilities P ermit is required for this project. 9) Please provide design for seismic attachment of cistern. 10)Provide roof design and calculations for seismic and vertical loads from new HVAC Roof Pac's. 11)Provide construction-details for connection of 5 1/8x12 GLB to 8x8 HSS column. When. responding, provide an itemized letter stating in what way each numbered issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the enclosed. City of Tigard, Letterof Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Res • ec ul r Dan Nelson Senior Plans Examiner (503) 718 -2436 . dann ©tigard -or.gov Phone: 503.639.4171 • Fax: 503.684.7297 . • www.tigard - or.gov • TTY Relay: 503.684.2772 , ■ • Community Development Building Plans Route Slip To: PermitCoordinator (PC) Date Routed: /is BY: diI a ( Project Name: Building Permit #: (3 12 2CZ Site Work Permit #: Land Use Case #: M At D2C0G Goo ( Engineering Case #: Building plans meet conditions of approval: � ' Planning (initials): l' A� c , Date: -.9 Engineering (initials) f Date: PC returns plans to: Notes: Reel wood. Ash - 1 , 1 pa ,(CL4 5 I a 4- Kiks 4 b-e a- I Gory_ l(r.(P.S CcE C,Mtttit ' - S(X- FCP-- \ - 5 kt, Fr- - MBE (L.Hoc - SPRA 'si k-c - ter./ - Sc. t TD . - 6- rt c u3& - OD 07 FE MI - c �� t(