Permit . CITY OF T MECHAN I CAL 4� DEVELOPMENT SERVICES PERMIT - 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 PERMIT S 8/977 -0312 2 DATE I5SUED: 08/28/97 PARCEL: 25102BD -01503 SITE ADDRESS...: 12740 SW PACIFIC HWY SUBDIVISION • FREWINGS ORCHARD TRACTS ZONING: C —G BLOCK • LOT •1 JURISDICTION: TIG CLASS OF WORK..:ALT FLOOR FURN • 0 EVAP COOLERS: 1 TYPE OF USE •COM UNIT HEATERS..: 0 VENT FANS...: 1 OCCUPANCY GRP..:M VENTS W/0 APPL: 1 VENT SYSTEMS: 0 STORIES • 0 BOILERS /COMPRESSORS HOODS • 0 FUEL TYPES 0 -3 HP • 0 DOMES. INCIN: 0 :ELC 3 -15 HP • 0 COMML. INCIN: 0 MAX INPUT: 0 BTU 15 -30 HP • 0 REPAIR UNITS: 0 FIRE DAMPERS ?..: 30 -50 HP : 0 WOODSTOVES..: 0 GAS PRESSURE...: 50+ HP • 0 CLO DRYERS..: 0 NO. OF UNITS AIR HANDLING UNITS OTHER UNITS.: 1 FURN < 100K BTU: 0 <= 10000 cfm: 0 GAS OUTLETS.: 0 FURN > =100K BTU: 0 > 10000 cfm: 0 Remarks : Carmichael's - Install swamp cooler and exhaust hood Owner: FEES CARMICHAELS type amount by date recpt 12740 SW PACIFIC HWY PRMT $ 26.50 JDA 08/11/97 97- 298151 TIGARD OR 97223 PLCK $ 6.63 JDA 08/11/97 97- 298151 5PCT $ 1.33 JDA 08/11/97 97- 298151 Phone #: Contractor: KALBERER FOOD SERVICE EQUIP KALBERER HOTEL SUPPLY CO 234 NW 5TH AVE $ 34.46 TOTAL PORTLAND OR 97209 Phone #: 503 -227 -1161 Reg #..: 000387 REQUI RED INSPECTIONS This pereit is issued subject to the regulations contained in the Mechanical Insp Tigard Municipal Code, State of Ore. Specialty Codes and all other Cooling Unt Insp applicable laws. All work will be done in accordance with Shaft Inspect i o n approved plans. This permit will expire if work is not started Hood Inspection within 180 days of issuance, or if work is suspended for more Fire Suppr Insp than 180 days. ATTENTION: Oregon law requires you to follow rules Duct Inspect ion adopted by the Oregon Utility Notification Center. Those rules are Final Inspection set forth in OAR 952 - 001-0010 through OAR 952 -001 -0080. You lay obtain copies of these rules or direct questions to OUNC by calling (503)246 -9187. e Issue By: 4 141 1 1041°-------- Permittee Signature: I,._,'.i At,/jam ++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + ++ + + + + + + + + + + + + + + + + ++ ++ Call 639 -4175 by 6:00 p.m. for inspections needed the next business day ++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + ++ + + + + + + + + + + + + + + + + + + +++ ' IN /!1/a7 City of Tigard IANICAL PERMI Plan , k/Rec. # � 13125 SW Hall Blvd. ` �PPLICATIO c1 Permit # fr ? --03e Tigard, OR 97223 ��� -r PE `)' �` (503) 639-417 9 — 6 -5(�- ilq 44 I Name of Development g escnption NOW �M 1_C l 5 Table 3A Mecham. ode QTY PRICE AMT d reu - -•�. i Job 4 D' W. • C C.- la 1) Permit Fee -0- -0- 10.00 Address r a e - ' 2 7 1. OR- ) ?3 2) Supplemental Permit 3.00 me or name of honoree.) Furnace to 100,000 BTU 1) incl. ducts & vents 6.00 Malang Address Phone urnace .1,111 : I + Owner 2) incl. ducts & vents 7.50 CdylSlate ja oor urnance 3) incl. vent 6.00 Name (or name of busmen) Suspended heater, wall heater CAP- tP- 1. \ 1 C)-1 AELJ S 4) or floor mounted heater 6.00 Malmg Address ` 1 Phone vent not inc. in Occupant I Z4b E \ PC. ( •lC,. (-ill/ 5) appliance permit 3.00 • lyISt.te Repair of heating, refrig. - rlC t is,:2:0 c)'. c3 22 a 6) cooling, absorption unit 6.00 Name Boiler or comp, heat pump, air cond. • l L 5 E 2 -2_1;cp 7) to 3 HP; absorp unit to 100K BTU 6.00 Maim Address Phone Boiler or comp, heat pump, air cond. LA S ��- 8) 3 -15 HP; absorp unit to 500K BTU 11.00 Contractor Gt bp Boiler or comp, heat pump, air cond. I .1■. b ` Sty � , 9) 15-30 HP; absorp unit .5-1 mil BTU 15.00 b ate stra on No. Bus. Tax No. :oi er or comp, eat pump, air con.. 10) 30-50 HP; absorp unit 1 -1.75 mil BTU 22.50 I hereby acknowledge that I have read this application, that the :oi er or comp, ea pump, air con.. information given is correct, that I am the owner or authorized 11) > 50 HP; absorp unit 1.75 mil BTU 37.50 agent of the owner, that plans submitted are in compliance with Air handling unit to State laws, that I arr. registered with the Construction Contractor's 12) 10,000 CFM 4.50 Board, that the number given is correct. (if exempt from State • it an• ing un registration, please give reason below.) 13) 10,000 CTM + 7.50 Non portable 14) evaporate cooler ( 4.50 -1 f, Vent fan connected • 15) to a single duct 1 3.00 1 ), 0 0 Ventilation system not j d / Cv• qui, 16) included in appliance permit 1 4.50 I t ,S 3 Sn ate. (.tuner or awn) te Hood served by L3E:D. - � L'" 1'C C.• 17) mechanical exhaust I 4.50 Lk. Describe won c new a Ilion a Mon repair ommercia or in.ustria to be done residential 0 non - residential 0 18) type incinerator 30.00 Existing use of T�e� Other i.e., woodstove, water building or property T� Jam. • 19) heater, solar, clothes dryers, etc. r iiii 4.50 i ij,ill' Proposed use of 20) Gas piping one to four outlets 2.00 building or property � 21) More than 4 -per outlet (each) 2.00 ( Type of fuel - oil 0 natural gas 1" • LPG 0 electric 0 NOTICE G Minimum Fee $25.00 SUBTOTAL " A 1 I PERMITS BECOME VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR 5% SURCHARGE (,, IF CONSTRUCTION OR WORK IS SUSPENDED OR • �i ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME PLAN REVIEW 25% OF SUBTOTAL ` pro!) AFTER WORK IS COMMENCED. . TOTAL • t ' Special Conditions Date issued by H:LLOGINtDSTSIMECHPMT 6/16/99 Activities for Case #: MEC97 -00312 • 2:14:11 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes • MECC007 Application received 8/11/97 JDA • PASS JD 8/18/97 • MECC008 Permit created 8/18/97 JSD PASS JD 8/18/97 MECC011 Routed to Plans Examiner 8/18/97 JSD PASS JD 8/18/97 MECC015 Reviewed Plans Routed to DSTS 8/25/97 RDP APPR RDP 8/26/97 MECC706 Mechanical lnsp 8/26/97 9/4/97 GS FAIL TLP 12/31/98 Day late, door locked no one there. MECC732 Hood Inspection 8/26/97 8/29/97 RB . FAIL TLP 12/31/98 Type 1 Hood: Mechanical contractor, Kalberer Manuf. 1. Seal joints of transitional duct above hood - make airtight. 2. Firestop ceiling above hood. 3. UL listed duct tape needed at joints (#181B FX type). 4. • Protect wood above roof to underside of jack. Pending submittal of revision for exhaust shaft construction: Steel vs: • wood studs. Fire suppression trip test ok, Todd 238 -5700, x170 report recd copy -OK MECC799 Final Inspection 8/26/97 2/17/98 RC FAIL JT 5114/98 1. Need brace on vent for lateral displacement. 2. Need • support for vent weight. 3. Need sediment trap in gas line at ' water heater. 5/14/98 letter sent to Carmichaels "call in for finals on MEC /BUP" Jeanne T. MECC016 DST Post - Review Completed 8/27/97 B PASS BON 8/27/97 MECCO50 (F) Ready to issue 8/27/97 B MEMO BON 8/27/97 Contractor needs business licensing. • MECC090 (F) Issue permit 8/28/97 B PASS DST . 8/28/97 MECC799 Final Inspection 12/31/98 TLP PASS TLP 12/31/98 MECC800 Case Finaled 12/30/98 TLP PASS J *H 1/3/99 • • Page 1 of 1 CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639-4175 Business Line: 639 -4171 91- 6.3k7 Date Requested - 1 " - 98 o AM PM BLD Location 0-740 0 4 ?- 1 t) / Wlt Suite ap dr — 03 ' Contact Person /0-4 •l./<_'l Ph &all- 0a4-3 PLM Contractor / Ph SWR 4 11N3114 Tenant/Owner CALM IG4ELS ELC Retaining Wall ELR Footing Access: Foundation FPS Cam" I Ftg Drain l SGN Crawl Drain Inspection Notes: Slab SIT �//���� � ' ' Post & Beam PAM C �(�(.r i € ,.,fi � ti/041"t — Ext Sheath /Shear She /Shear a /DR Framing � p� J S �� - �i1 � /� �7 Insulation , n (S / ! � 90 � :.f1�4r�( t� A/Lo 0 e () L1 / 9? Drywall Nailing �. Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof AIDA) �� (� �A,✓+a .J • 4 :J PART FAIL P' i ' BING , Post & Beam Under Slab (re•■■•----- Top Out J� Water Service 1 Sanitary Sewer ��� Rain Drains (��i" y — . J Final PAS FAIL Post & Beam /v // Rough In /C___ Gas Line [.v ` Sir s .es , Dampers `ir ~ART FAIL RICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk D /2/5 pg Inspector Other Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.