Loading...
Correspondence S o o aoad, Cornelius • , • le <f) r\ 0 ÷ k,o9 • 503 - 709 -9653 • PC ' 0 4 0 " F-- 9)) November 3, 2006 n City of Tigard Building Division 13125 SW Hall Blvd. Ti•ard, OR 9722 Reference: CHC Enterprises Project No. 06069 Permit No.BUP2006.530, issued 11/1/06 Subject: • rrection to Plans Dear Building Division: Refer to attached, revised Code Summary for the above referenced project. I corrected a typographical error. Previously the Code Summary indicated that the building was sprinklered. It is not sprinklered and does not need to be to meet provisions of the building code. The revised attached Code Summary correctly identifies the building as not having sprinkler coverage. Please contact me if you have any questions or require additional information. Thanks. Yours truly, Robert C. Simpson ogt Robert Simpson Architect, PC Copies: Will Coffee, CHC Enterprises Alan Volm, Pacific Crest Structures Enclosure: Code Summary File: C: \ My Documents \ Work \ 2006 \ 06069 \ LTigerdl .doc Applicable Code: 2004 OSSC Non - seperaed Use Building Construction type: V -B No. of stories in building: 1 (no basement) Total floor area of building: 2,269 sf Building occupancy groups: B Basic tabular area: 19,000 sf Frontage increase: W =30 If= 100((173.5/280) - 0.25)(30/30) =37 Allowable area: Aa =19 ,000 +(19,000(37)/100) +0 = 26,030 sf Occupancy load: 23 oc. Fire resistive ratings: Partitions Sprinkered building: No Plumbing fixture requirement: Water closets: B: 23/25 =0.9 Lavatories: B: 23/40 =0.6 Plumbing Fixtures provided: Water closets: 2 Lavatories: 2 A11 Code Summary