PRODUCT SPECIFICATIONS
fr2c1,
Goodman
Air Conditioning & Heating
GS(13
13 SEER
NIGH- EFFICIENCY
SPLIT SYSTEM
AIR CONDITIONER
E! Residential Commercial
WARRANTY ,,.
1 /z TO 5 TON
The GSC13 Split System Air Conditioner features the unique Goodmanc'sound control top designed for quiet operation.
In addition, the unit has an attractive louvered metal guard that protects the coil from damage plus a powder -paint
finish that provides premium durability and improved UV protection.
Standard Features Cabinet Features
• Energy- efficiency compressor • Unique Goodman' sound control top design
• Quiet condenser fan system • Steel louver coil guard
• Factory- installed liquid line filter dryer t • Heavy -gauge galvanized -steel cabinet
• Copper tube /aluminum fin coil • Attractive Architectural Gray powder -paint finish with 500-
• R -22 refrigerant- charged for 15' of refrigerant lines I hour salt -spray approval
• Brass liquid and suction service valves • When properly anchored, meets the 2001 Florida Building
with sweat connections Code unit integrity requirements for hurricane -type winds
• Contactor with lug connections
• Ground lug connection Accessories
• Anchor Bracket Kit
• ARI Certified; ETL Listed
• Anti -Short Cycle Kit
Air Handler and (oil Compatibilities • Hard -start Kit
• ARPF, ADPF, ARUF, AEPF — versatile upflow, horizontal or • Freeze Protection Kit
downflow air handlers; may be located in closets, utility • Liquid Line Solenoid Kit
rooms, attics, or basements • Outdoor Thermostat
• AWUF vertical wall- mounted electric heat air handlers
• ACNF ceiling- mounted electric heat air handlers
• MBR /MBE modular blower QA °9Y
• CA, CH, and CSCF indoor coils ,� A
' Qar 4L . �' v
SS - GSC13 www.good ma n mfg. com 5/07
Supersedes 2/07
PRODUCT SPECIFICATIONS
NOMENCLATURE
I GI I S I C I I 1 3 I I 036 I I h I I A I A I
Brand Name
G = Goodman (Standard Minor Revision
Feature Set Models) (not used for order
S = Goodman (High Feature entry or inventory
Set Models) management)
Product Category
S = Split Major Revision
(not used for order entry
Unit Type or inventory management)
C = Condenser R -22
X = Condenser R -410A Electrical
H = Heat Pump R -22 1 = 208/230 V, 1 Phase, 60 Hz
Z = Heat Pump R -410A SEER 2 = 220/240 V, 1 Phase, 50 Hz
13 = 13 SEER 3 = 208/230 V, 3 Phase, 60 Hz
14 =14 SEER 4= 460 V, 3 Phase, 60 Hz
16 = 16 SEER 5 = 380/415 V, 3 Phase, 50 Hz
Nominal Capacity
018= 1.5tons 048 =4 tons
024 = 2 tons 060 = 5tons
030 = 2.5 tons 090 = 7.5 tons
036 =3tons 120 =10 tons
042 = 3.5 tons
2 www.good ma n mfg.com SS -GSC13
PRODUCT SPECIFICATIONS
SPECIFICATIONS
GSC13- GSC13 GSC13 GSC13 GSC13 GSC13 GSC13 GSC13
0181 AA 0241A 0241C 0301A 0361A 0361B 0361C 0361D
Cooling Capacities
Nominal Cooling (BTU /h) 18,000 24000 24,000 30,000 36,000 36,000 36,000 36,000
Decibels 76 76 76 76 76 76 76 76
Compressor
RLA 6.2 7.7 10.4 9.7 12.2 12.5 11.2 12.2
LRA 35.0 40.0 54.0 49.0 73.0 73.0 68.0 73.0
Condenser Fan Motor
Horsepower 1/6 1/6 1/6 1/6 1/6 1/6 1/6 1/6
FLA 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
Refrigeration System
Liquid Valve Size ("0.D.) 3/ 3/4" /" /" 3/4" 3/ 3/ 3/
Suction Valve Size ( "O.D.) 3 /4" 3 /4" 3 /4" 3 /4' 3 /4" 3 /4' 3/4" 3/4"
Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat
Refrigerant Charge 95 99 102 123 125 125 120 125
Shipped with Orifice Size 0.055 0.059 0.059 0.065 0.074 0.071 0.074 0.074
Electrical Data
AC Volts 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230
Hz / Phase 60 Hz /1 60 Hz /1 60 Hz/1 60 Hz /1 60 Hz/1 60 Hz /1 60 Hz /1 60 Hz /1
Min. Circuit Ampacity' 9.3 11.2 14.6 13.6 16.8 17.1 15.5 16.8
Max. Overcurrent Device 15 15 20 20 20 30 20 25
Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253
Electrical Conduit Size 1 /3" or 3 /4" '/2' or %" �/2" or 3 /4" ' /2" or 3 /4" '/2" or 3 /4" ' /2" or 3 /4" 1 /2 or 3 /4" '/" or 3 /4"
Ship Weight (Ibs) 173 195 182 195 199 205 214 199
I Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
2 Must use time -delay fuses or HACR -type circuit breakers of the same size as noted
SS - GSC13 www.goodmanmfg.com 3
PRODUCT SPECIFICATIONS
DIMENSIONS
w
,y , IN .t'
3
� �'` `�."1���11,�1��
3 r �� gib
r 111
j I N' NI l ilt 1 11 11)
Z Itr i r iii, , fill '-"
f
Model Dimensions
WxDxH
GSC130181A 26 x 26 x 29%
GSC130241A 26 x 26 x 34%
GSC130241C 26 x 26 x 34%
GSC130301A 29 x 29 x 34%
GSC130361A 29 x 29 x 34%
GSC130361 BA 29 x 29 x 34%
GSC130361 CA 29 x 29 x 34
GSC130361 D 29 x 29 x 34%
GSC130361E 29x29x34%
GSC130363A 29 x 29 x 34%
GSC130421A 29 x 29 x 34%
GSC130481A 29 x 29 x 38'/4
GSC130483A 29 x 29 x 38%
GSC130484A 29 x 29 x 38%
GSC130601B 35'%x 35% x 38%
GSC130603A 35% x 35% x 38%
GSC130604A 35'/2 x 35% x 38%
,�_ s, ___.
SS -GSC13 www.goodmanmfg.com 5
PRODUCT SPECIFICATIONS
PERFORMANCE RATINGS (CONT.)
Cooling Capacity (BTU /h)
Condenser Indoor Model SEER' EER ARI #
Total Sensible
AC36 -XX 28,000 20,500 13 11.5 734698
ACNF30XX1A* 28,000 20,500 13 11.5 734815
ADPF304216A* 29,000 21,460 13 11.5 1038108
ADPF30421A* 29,000 21,500 13 11.5 734826
AEPF183016A* 29,000 21,460 14 12.2 1038109
AEPF18301A* 29,000 21,500 14 12.2 734732
AEPT030- 00 * -1* 29,000 21,500 14 12.2 734714
ARPF048- 00B -1* 29,000 21,500 13 11.5 734798
ARPF303016A* 29,000 21,460 13 11.5 1038110
ARPF30301A* 29,000 21,500 13 11.5 734886
ARPT042- 00 * -1* 29,000 21,500 13 11.5 734879
ARUF042- 00 * -1* 29,000 21,500 13 11.5 734889
ARUF182416A* 27,600 20,424 13 11.5 1038144
ARUF18241A* 27,600 20,424 13 11.5 1038143
ARUF303016A* 29,000 21,460 13 11.5 1038111
ARUF30301A* 29,000 21,500 13 11.5 734784
AWB36 -XX 28,000 20,500 13 11.5 734873
AWUF36XX1A* 28,000 20,500 13 11.5 734875
CA *F037 *2* +EEP 29,000 21,500 13 11.5 734718
CA *F037 *2 * +G *V80704B ** 29,000 21,500 14 12.2 734672
CA *F037 *2 * +G *V90704C ** 29,000 21,500 14 12.2 734651
CA *F037 *2 * +G *V950453B ** 29,000 21,500 14 12.2 734774
CA *F037 *2 * +G *V950704C ** 29,000 21,500 14 12.2 734902
CA *F037 *2 * +MBE1200 * * -1 29,000 21,500 14 12.2 734687
GSC13 CA *F042 *2* +EEP 29,000 21,460 13 11.5 879290
0301A*
CA *F3030 *6A* +EEP 29,000 21,500 13 11.5 734671
CA *F3030 *6A * +G *V80704B ** 29,000 21,500 14 12.2 734807
CA *F3030 *6A * +G *V90704C ** 29,000 21,500 14 12.2 736252
CA *F3030 *6A * +G *V950453B ** 29,000 21,500 14 12.2 734781
CA *F3030 *6A * +G *V950704C ** 29,000 21,500 14 12.2 734724
CA *F3030 *6A * +MBE1200 29,000 21,500 14 12.2 734816
CA*F3131*6A*+EEP 29,000 21,460 13 11.5 879204
CHPF030A2* +EEP 28,400 21,016 13 11.5 1002299
CHPF042B2* +EEP 29,000 21,500 13 11.5 734727
CHPF042B2 * +G *V80704B ** 29,400 21,800 14 12.2 734801
CHPF042B2 * +G *V90704C ** 29,400 21,800 14 12.2 734748
CHPF04282 * +G *V950453B ** 29,400 21,800 14 12.2 734726
CHPF2430B6A* +EEP 29,000 21,500 13 11.5 734900
CHPF2430B6A * +G *V80704B ** 29,400 21,800 14 12.2 734888
CHPF2430B6A * +G *V90704C** 29,400 21,800 14 12.2 734865
CHPF2430B6A * +G *V950453B ** 29,400 21,800 14 12.2 734666
CSCF3036N6A* +EEP 29,000 21,500 13 11.5 734814
CSCF3036N6A * +G *V80704B ** 29,000 21,500 14 12.2 734809
CSCF3036N6A * +G *V90704C ** 29,000 21,500 14 12.2 734728
CSCF3036N6A * +G *V9504536** 29,000 21,500 14 12.2 734794
H49F +EEP 29,000 21,500 13 11.5 734795
H49F +G *V80704B ** 29,000 21,500 14 12.2 734746
H49F +G *V90704C ** 29,000 21,500 14 12.2 734837
H49F +G *V950453B ** 29,000 21,500 14 12.2 734761
8 www.goodmanmfg.com SS -GSC13
PRODUCT SPECIFICATIONS
ACCESSORIES
Model Description GSC13 GSC13 GSC13 GSC13 GSC13 GSC13 GSC13
018 024 030 036 042 048 060
ABK -20 Anchor Bracket Kit • X X X X X X X
ASC -01 Anti -Shod Cycle Kit X X X X X X X
CSR -U -1 Hard -start Kit X X X X
CSR -U -2 Hard -start Kit X X X X
CSR -U -3 Hard -start Kit X X
FSKO1A Freeze Protection Kit 1 X X X X X X X
LSKO1A Liquid Line Solenoid Kit 2 X X X X X X X
OT18 -60A Outdoor Thermostat X X X X X X X
TX3N2 TXV Kit X X X X
TX5N2 TXV Kit X X X
• Contains 20 brackets; four brackets needed to anchor unit to pad
1 Installed on indoor coil
2 Field- installed, non - bleed, expansion valve kit — Condensing units and heat pumps with reciprocating compressors require the use of start-
assist components when used in conjunction with an indoor coil using a non -bleed thermal expansion valve refrigerant metering device or
liquid line solenoid kit.
/ \e
G oodman Goodman Manufacturing Company, L.P., reserves the right to discontinue,
or change at any time, specifications or designs without notice or without
/ incurring obligations.
Copyright O 2007 • Goodman Manufacturing Company, L.P. • Houston, Texas
Air Conditioning & Heating Printed in the USA.
20 www.good man mfg.com SS -GSC13