Correspondence • 64 August 14, 2003 CITY OF TIGARD Jason Ellis • OREGON Town & Country Heating Inc. 6101 NE 127 Avenue, Suite 200 Vancouver, WA 98682 RE: MECHANICAL EQUIPMENT @ COIN METER LAUNDRY Project Information Mechanical Permit: MEC2003 -00411 Construction Type: VN Tenant Name: Coin Meter Laundry Occupancy Type: B Address: 11945 SW Pacific Highway Occupant Load: NA Area: NA Stories: 1 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2002 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99- 01) 1999 edition. The submitted plans are approved subject to the following. 1. The unit is identified as providing 2000 cfrn. Smoke detectors shall be installed in return air systems with a design capacity greater than 2000 cfrn. Upon activation, the smoke detector shall shut down the air distribution system. Smoke detectors shall be connected to a fire alarm system and shall activate an audible and visible alarm at a constantly attended location. 606.2, 606.4 & 606.4.1 OMSC 2. Each appliance shall be provided with a shutoff valve separate from the appliance. The shutoff valve shall be located within six feet of the appliance served. Access shall he provided to the shutoff valve. C409.5 OMSC • :::::: • • 3. Equipment and appliances regulated by this code requiring electrical c :i ons • • • ••• • • shall have a positive means of disconnect in accordance with the Electrical code. • • 301.7 OMSC • • • • . 4. Appliances shall be accessible for inspection, service, repair or replaceple withotit•• removal of permanent construction. 306.1 OMSC •• •• 5. Manufacturer's installation instructions shall be available on the jobsite at the t inspection. 304.1 OMSC • • •• • • •••• • 6. Condensate from cooling coils or evaporators shall be collected and discharged to an approved plumbing fixture or disposal area. 307.1 OMSC 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 • 7. Appliances installed on roofs or elevated structures exceeding 16 feet in height shall be provided with a permanent means of access grade or floor leveL 306.5 OMSC Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. • When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and cessing the documents. Respect y, ;, 3 ian clock, • Se.' • r Plans Examiner .... • • • . •••• • .• • • • • • • .. • . • •• .•.. • • • • • • •• • • •• •• • • •••• • • •••• • • . : .• •• • ... . . . •..• • • • .•.. • • • • •. .. •• • • •••• Lc : c,0 r July 31, 2003 Jason Ellis Town & Country Heating Inc. 6101 NE 127 Avenue, Suite 200 • Vancouver, WA 98682 RE: MECHANICAL EQUIPMENT @ COIN METER LAUNDRY Project Information Mechanical Permit: MEC2003 -00411 Construction Type: VN Tenant Name: Coin Meter Laundry Occupancy Type: B Address: 11945 205-SW S m Duo Occupant Load: NA • Area: NA t N-4.41-40 Ia3 Stories: 1 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2002 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99- 01) 1999 edition. The following information is required prior to issuance of a Mechanical Permit. . 1. Provide structural calculations and a roof framing plan for review to determine the adequacy of the existing structure to support additional loading imposed by the new mechanical units. 2. Permanent equipment supported by the structure, 400 lbs and over, shall have their attachments designed in accordance with formulas in section 1632 of the Oregon Structural Specialty Code. Provide details for the attachments. 3. Appliances installed on roofs or elevated structures exceeding 16 feet in height shall be provided with a permanent means of access grade or floor level. 306.5 OMSC clarify roof height. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. • • Respectfully, • Brian Blalock, Senior Plans Examiner