Loading...
Plans E Lco�3 - � /1 ,/� , Z • r INTERIOR MOTIVES.. - .. P.,.. � o O Z w. LOAD > >n gz 0 > GENERAL LIGHTING LOAD H p OFFICE - `•: 0 - SF X .'...3.00 VA / SF = 0 VA T220 -3(a) W CV LL 0 COMMON AREAS SF X :' VA / SF = 0 VA U ce 0 Z ROOF . SF X 0.50 VA / SF = 0 VA W H 0 RETAIL 8,000' SF X '-.:3:00 VA / SF = 24,000 VA V j . . 't.; SF X • '0:50 VA / SF = 0 VA m SF X ':"0.50 VA / SF = 0 VA 8,000 TOTAL SF TRACK LIGHTING ': 20 FT X 150VA / 2FT = 6,750 VA 220 -12(b) EXT. LIGHTING 200 VAX I - . .,. ''' ,4IFIXTURES = 800 VA SIGN LIGHTING -1 - ,200 VA (1200VA MIN.) = 1,200 VA 220- 3(b)(6) SHOW WINDOWS : 110 FT X 200VA / FT = 22,000 VA 220- 3(b)(7)(b) TOTAL LIGHTING LOA . = 54,750 VA DEMAND FACTOR = 125% 230- 42(a)(1) TOTAL LIGHTING DEMAND = 68,438 VA RECEPTACLE LOAD -' . ' 0 ‘ I SF X ,, , ,1.00 VA / SF = 0 VA T220 -3(a) RECEPTACLES 409 REC. X 180VA / REC. = 73620 VA MULTIOUTLET FT X 180VA / 5 FT = 0 VA 220- 3(b)(8)(a) MULTIOUTLET FT X 180VA / FT = 0 VA 220- 3(b)(8)(b) TOTAL RECEPTACLE LOAD = 73,620 VA FIRST 10KVA X 100% = 10,000 VA T220 -13 RAMAINING VAX 50% = 31,810 VA TOTAL DEMAND LOAD = 41,810 VA SPECIAL LOADS CONT? ":..5 GAS PACKS X :. 11,520 VA . 'N;,: = 57,600 VA 1 WATER HEATER X •: 4,500 VA 'N.'. = 4,500 VA 0 VA X VA N = 0 VA 62,100 VA LARGEST BETWEEN HEATING AND A/C LOAC HEAT I�..� ,. T. • IVA NCI IVA = 0 VA 220 -15, KVA = KW LARGEST MOTOR LOAD I •: IVA X 25% = 0 VA 220 -14 PHASES LOAD SUMMARY GENERAL LIGHTING AND RECEPTACLE LOAD = 68,438 VA RECEPTACLE LOAD = 41,810 VA SPECIAL LOADS = 62,100 FIXED APPLIANCE LOAD = VA LARGEST BETWEEN HEATING AND NC LOAD = 0 VA _ LARGEST MOTOR = 0 VA TOTAL LOAD = 172,348 VA TOTAL AMPS AT I 2081 VOLT I 3I PHASE = 478 A 3/26/03 MultlFamlly_load_calc.xls ' I l r . • CITY: O ° TIGARD ELECTRICAL PERMIT APPLICATION /REQUEST QTY COST TOTAL Service or Feeders: Plan Review is required.if: 200 amps or less . 3 " $80.30 $240.90 (Check all boxes that apply) 201 to 400 amps : -' :1.. ' $106.85 $106.85 401 to 600 amps $160.60 $0.00 Service over 225 amps 601 to 1000 amps • $240.60 $0.00 System over 600 volts nominal over 1000 amps or volts $454.65 $0.00 Health care facility Reconnect only I -. - $66.85 $0.00 Hazardous location x Feeders 225 amps or more Temp Services or Feeders: Manf'd Structure or RV park 200 amp or less $66.85 $0.00 201 to 400 amps $100.30 $0.00 ,401 to 600 amps _:`s': $133.75 $0.00 Over 601 amps or 100 volts - use service or feeder rates e Branch Circuits: x Please check here if any Each - purchased witli: :59_ • I $6.651 $392.35 boxes above are checked service or feeder (This will calculate plan review charges) First branch circuit without: :1 $46.85 $0.00 service or feeder purchase \ ,� $6.651 $0.001 "J \U (Each additional circuit ht _`;:��- •;�, � M - Outline lighting $53.40 $0.00 Limited energy < <it -- $75.00_ $0.00 Total $740.10 v State Surcharge $59.21 \ y v \ Plan Review $185.03 Please see Jennifer for fire alarm quote TOTAL PERMIT COST $984.33 Job #: 90249 Estimator: Collin Cedergreen 1 Address: Interior Motives 11875 S.W Pacific HwyTigard, Or PM : Ken Dale Descri tion • Permit Request Date: Lighting Retail Store Permit Needed By: Property Owner Information: Interior Motives 12172 S.W Garden PL Tigard, OR 97223 •