Specifications ,re c 2 7 ? 2 S-cre '/
Single Ply Roofing Systems (TPO)
NAT JM TPO -45 ❑JM TPO 60
Johns Manville
•
Description Approvals
JM TPO -45 and TPO -60 are thermoplastic polyolefin (TP0) JM mechanically fastened and adhered TPO Roof Systems are
membranes reinforced with a polyester fabric, and designed for classified by UL (Underwriters Laboratories, Inc.) and FM
use in mechanically fastened and adhered roofing applications. Global (Factory Mutual).
Use
Energy and the Environment
JM TPO membranes can be installed in new, reroof (tear -off) Energy Star Pass Reflectivity: 0.78
and recover roof constructions. In recover construction, if the Title 24 Pass Reflectivity: 0.78 Emissivity: 0.87
existing roof is sound, the JM roof can eliminate the cost of LEED Reflectivity: 0.78 Emissivity: 0.90
disposing of the original roof. Recycled Content
Colors Post Consumer. 0% Post Industrial: 3 -5%
White, Grey and Tan Producing Locations: Tuscumbia, AL
Special colors are available with extended lead times. Results shown are for initial reflectivity and eminence for white membranes;
Minimum order quantities may apply. Contact your local JM values
emissivity e t values far Title 24
ested per ASTM E r per ASTM C 1371; LEE) emissivity
sales representative for additional information.
Installation
Standard Sizes
Because JM TPO membranes are thermoplastic, they can be
Color Width Length rolled out onto the roof substrate and easily welded into one
White 4 ft. (1.2 m) 100 ft. (30.5 m) homogeneous sheet using hot air welding procedures.
6 ft 2 in. (1.9 m) 100 ft. (30.5 m) JM TPO membranes can be mechanically attached or adhered
8 ft. (2.4 m) 100 ft (30.5 m) to the structural roof deck in accordance with FM Global
10 ft (3.0 m) 100 ft (30.5 m) requirements, building codes, published standard fastening
12 ft. 4 in. (3.8 m) 100 ft (30.5 m) patterns or adhesives recommendations.
Grey and 4 ft (1.2 m) 100 ft. (30.5 m) Refer to JM TPO Roofing Systems Guide Specifications, Detail
Tan 8 ft. (2.4 ml 100 ft (30.5 m) Drawings and Technical Bulletins for instructions.
JM TPO membranes meet or exceed all of the requirements of ASTM D 6878.
ASTM ASTM Typical ASTM ASTM Typical
'' pmti>"N "'ToM ... Minimum Values Property Test Method Minimum Values
Weight, Ibs /sq. ft. D 7 Brittleness Point, D 2137 -40 ( -40) -49 ( -45)
(kgs./sq. meter) Max., °F 1°C)
JM TP0-45 0.21 (1.03) Ozone Resistance D 1149 Pass
J TP0 -.0 0.29 (1.42) Properties
.After
ness, m. (mm) 1 751 0.039 (1.0) Heat s After
Af D 573/751 Pass
JM TPO-45 0.045 (1.1)
JMTPO -60 0.060(1.5) Breaking Strength, 225(1) 330(1.5)
Tolerance on Nominal D 751 +/- 10% +/- 10% Ibf(kN)
Thickness Elongation at Fabric Break, 13.5 25
Thickness Over Scrim, D 6878 0.012 (0.30) Min., %
in. (mm) Annex Al Tearing Strength 551.25) 15613)
JM TPO-45 0.015 (0.38) Ibf(kN)
JM TP0 -60 0.022 (0.56) Weight Change, +/ 1 -0.02
Breaking Strength, D 751 220 (979) 330 (1468) Max., Mass %
Ibf (N)
Field Seam Strength, 0 751 66 (294) 75 1330) Water Absorption, D 471 +/- 3 + 1.2
Ibf (N) Max, Mass %
Elongation at Break D 751 15 30 Water Vapor Permeance E 96 0.012
of Fabric % linear Dimension Change, D 1204 +/ - 1 -0.01
Tearing Strength, 0 751 55 (245) 156 (694) Max %
Ibf (N) Puncture Resistance, FTM 101C 200(890) 33711500)
Accelerated G 151/154 Pass Ibf (N) Method 2031
Weathering E
Refer to the Material Safety Data Sheet prior to using JM TPO. Material Safety Data Sheet is available by calling 800 - 659 -3103 or online
at www.jm,com.
IM ) ,1 - ''
a . oO - ��`
RS -8288 3.08
W A T o n v i n e II A I L VI I u n
Page 1 of 1
Jerome Madden
From: Mark Schick [mark @armpm.com]
Sent: Tuesday, October 16, 2007 6:25 PM
To: 'Jerome Madden'
Subject: RE: unit weights •
Unit Weights are as follows:
Suite A GP -1 614Ib
Suite A GP -2 550lb
Suite B GP -3 845Ib
Suite C GP-4 5971b -- S S 7 •
Suite D GP -5 5751b �- , p °�' r .nt /s W • F t-
Suite E GP-6 575lb r Vt P•+ V N i T 3
Suite G GP -7 5001b
Suite G GP-8 5001b Suite G Swap Cooler 1 1 751b V per 11
Suite G Swap Cooler 2 1 75Ib
Mark Schick
Property Manager
ARM Property Management
503452 -2115 Office
503 -452 -2139 Facsimile
mark@armpm.com
www.armp com
From: Jerome Madden [mailto :Jerome @maddenbaughman.com]
Sent: Monday, October 15, 2007 4:51 PM
To: mark @armpm.com
Subject:. unit weights
Mark, any chance of getting your mechanical contractor to verify the weights of the units on the old Payless?
Jerome
10/17/2007
TPO Product Information Page 1 of 1
"The name trusted,: roofing since 1906"
' au
MULE -HIDE � B..T - ' a■ , ' „ y . •
PRODUCTS ct
114 110 n fir.
" �, Learn more about this
Featured Project
Products ABOUT US CONTACT US PRODUCTS & SYSTEMS LINKS HOME SITE MAP
Specs TPO
Codes jat Twitrustaitut
Videos The "Affordable White Roof" — TPO Estimating Tips
Mule -Hide TPO Systems. Heat Weld FAQ's
Sales Reps TPO Accessories
Distributors
TPO Product Specifications
What's New Back
National Support • The performance of rubber with
heat - welded seams
Warranty • The weathering and low temperature flexibility of EPDM
Information with the superior seam strength of heat - weldable
membranes
Warranty Eligible • White membranes reflect sunlight and cool building
Contractor Login interior for energy savings.
• Wide sheets mean less seams and less labor compared to "
Disclaimer standard PVC sheets.
• More product on top of the scrim where you need it most
- one of the thickest top plies in the industry.
• Minimal shrinkage for watertight integrity you can count
on.
• Complete line of TPO Accessories such as Pre- fabricated
Pipe Boots and Pre -Cut Corners.
• Standard System Warranties and Membrane -Only Material Warranties.
• Mechanically Attached, Fully Adhered, and Self- Adhering System Specifications.
• Membrane meets or exceeds ASTM performance standards.
Reinforced TPO (white, gray, tan, other colors by special order)
.045 ", .060 ", & .080 "*
.Self-Adhering TPO (white) not available in .080
• Thermoplastic polyolefln based for superior strength
and weatherability
• Lightweight yet highly resistant to tears, impact, ;
punctures, & wind uplift
• Ideal for both new construction and
reroofing /restoration
• Reinforced membrane easily handles building
thermal expansion & contraction •
• Minimal shrinkage - ideal for mechanically attached or fully
adhered systems
• Environmentally friendly - no chlorine, recyclable
CRC
' r;
M O ,. W a 0 >; r>X rirR
MSCR Fi14 t
TPO Membrane is CRRC® Rated and Energy Star Listed.
TPO Estimating Tips
Heat Weld FAQ's
TPO Accessories
TPO Product Specifications
Back
http: / /www.mulehide.com/tpo /tpo.html 5/13/2008
Mule -Hide Products, Co., Inc. Page: 14
•
Underwriters laboratories (UL)
Roofing Systems - TPO
MAINTENANCE AND REPAIR SYSTEMS
The insulation and membrane are fastened to the deck with metal screws and discs. The
membrane laps are hot air welded.
CLASS A. B. AND C
7. Deck: C -15/32 Incline: 1/2
Existing Roof System: — Class A, B or C roofing system, to retain the existing
Classification, is covered with:
Slip Sheet: — One or more layers of the following - Lydall "Manniglas 1200" mat, 15 mil,
Atlas Roofing "FR -10" or "FR 50 ", Elk 'Versashield" or Type G2 base sheet, laid loosely.
Membrane: — "Mule -Hide TPO -c ", "Mule -Hide TPO -c Extra ", or "Sure -Flex PVC ",
mechanically fastened.
8. Deck: C -15/32 Incline: 3/4
Existing Roof System: — Class A, B or C roofing system, to retain the existing
Classification, is covered with:
Slip Sheet: — One or more layers of the following - Lydall "Manniglas 1200" mat, 15 mil,
Atlas Roofing "FR -10" or "FR 50 ", Elk 'Versashield" or Type G2 base sheet, laid loosely.
Membrane: — "Mule -Hide TPO -c (FR) ", mechanically fastened.
9. Deck: C -15/32 or NC Incline: 1
Existing Roof System: — Class A, B or C roofing, gravel to be maintained on gravel
built -up system, to retain the existing Classification, is cover with:
Insulation: — Owens Corning Specialty & Foam Products "Durapink ", 1 in. max.
Membrane: — "Mule -Hide TPO -c ", "Mule -Hide TPO -c (FR) ", "Mule -Hide TPO -c Extra ",
"Mule -Hide TPO -c Extra (FR)" or "Mule -Hide TPO -c Fleece Back ", mechanically
fastened.
10. Deck: C -15/32 Incline: See Note
Existing Roof System: — Class A, B or C roofing system, to retain the existing
Classification, is covered with:
Slip Sheet (Optional): — One or more layers Atlas Roofing "FR 50 ", Elk "VersaShield
Underlayment" or "VersaShield FB -2S ".
Membrane: — "Mule -Hide TPO -c ", "Mule -Hide TPO -c (FR) ", "Mule -Hide TPO -c Extra ",
"Mule -Hide TPO -c Extra (FR)" or "Mule -Hide TPO -c Fleece Back ".
Note: Max incline shall be in accordance with Classification established for the existing
roofing system, but can not exceed 1- 1/2:12.
11. Deck: C -15/32 Incline: See Note
Existing Roof System: — Any Class A, B or C roofing system, covered with:
Membrane: — "Mule -Hide TPO -c Fleece Back 100 or 115 Membrane ", adhered with
"Mule -Hide SP -100 Adhesive ".
Note: Max incline shall be in accordance with Classification established for the existing
roofing system, but can not exceed 1:12.
1195 Prince Hall Dr. P.O. Box 1057
Beloit, WI 53511 - 5481 608 - 365 - 3111 • Fax: 608 - 365 -7852 • Beloit, WI 53512 -1057
P acific
R oofing
C ompany
C
� 1
v�J
P.O. BOX 1728 • BEAVERTON, OR 97075 • (503) 647 -2894 • FAX 647 -7415
CCB# 41571
c7:�:c lc z cA
•
P acific
R oofing
C ompany
•
•
•
•
- 1
p
M
Y
l
P.O. BOX 1728 • BEAVER • N, OR 97075 • (503) 647 -2894 • FAX 647-7415.
CCB# 41571
PRODUCT DATA SHEET
MULE -HIDE TPO -c MEMBRANE
(Standard and FR)
PRODUCT DESCRIPTION
Mule- Hide's TPO -c Membrane is a polyester reinforced, .045" or .060 thick, polyolefin based, thermoplastic, heat -
weldable membrane. The Mule -Hide TPO -c membrane is also available in thicknesses of .072" and .080" (see TPO-c
EXTRA). It is used in mechanically attached and fully adhered roofing assemblies. It may also be used as flexible
membrane flashings for walls, curbs, etc, when installing TPO -c membrane roofing systems.
BASIC USES
The TPO -c membrane is used in mechanically attached and fully adhered roofing systems in new construction, reroofing
and recover (retrofit) applications. The system must be installed over an acceptable roof insulation or other suitable
substrate. See the Mule -Hide TPO Specifications Manual for complete specifications and details.
SPECIFICATIONS
Colors: White top /Black bottom (Standard)
(Special Order Top Colors) Tan and Gray.
Material: .045 -inch and .060 -inch (nominal) thick polyester reinforced thermoplastic
Sizes: Field Sheet — 8', 10' and 12' by 100'
Perimeter Sheet — 4' , 5' and 6' by 100'
Property after
Physical Properties Test Method Typical Values ASTM D -573 aging'
Unaged Sheet 28 days @ 240 °F
Thickness Tolerance on nominal, % ASTM D -751 ±10
Thickness over scrim, in. (mm) ASTM D -6878
45 — mil Optical Method 0.015 (0.381) ±10%
60 — mil (avg. of 3 areas) 0.020 (0.508) ±10%
225 (1.0) min. 45 -mil 225 (1.0) min.
Breaking Strength, lbf (kN) ASTM D -751 320 (1.5) typical 45 -mil 320 (1.5) typical
(Grab Method) 250 (1.1) min. 60 -mil 250 (1.1) min. 60 -mil
360 (1.6) min. 60 -mil 360 (1.6) 60 -mil
Elongation at break of fabric ASTM D -751 25 typical 25 typical
Tear Strength, lbf (N) 8 by 8 in. ASTM D -751 55 (245) min. 55 (245) min.
specimen (B Tongue Tear) 130 (578) typical 130 (578) typical
• •
Brittleness point, F° (C °) ASTM D -2137 0 46) al
Linear Dimensional Change +/- 0.5 max
(shrinkage), % after 6 hours @158° F ASTM D -1204 - 0.2 typical
•
(70° C)
Ozone resistance, 100 pphm, 168 ASTM D -1149 No cracks No cracks
hours
Resistance to water absorption
After 7 days immersion 158 °F (70 °C) ASTM D-471 4.0 max.
Change in mass, % 2.0 typical
Resistance to microbial surface ASTM D -3274
growth, rating (1 is very poor, 10 is no 9 -10 typical
gr ) 2 -yr s. Florida
Field seam strength, lbffin. (kN /m) ASTM D -1876 25 (4.4) min.
Seams tested in peel 60 (10.5) typical
Water vapor permeance, Perms ASTM E -96 0.10 max.
0.05 typical
Water Absorption ASTM D-471 0.7%
(a? 158 °F, 1 week
250 (1.1) min. 45 -mil
Puncture resistance, lbf (N) FTM 101C 325 (1.4) typical 45 -mil
Method 2031 300 (1.3) min. 60 -mil
350 (1.6) typical 60 -mil
Resistance to xenon -arc wearthering ASTM G -155 No cracks
Xenon -Arc, 17,640 kj/m total radiant 0.70 W /m No loss of breaking
exposure, visual condition at 10X 80 °C B.P.T. or tearing strength
'Aging conditions are 28 days at 240 °F (116° C) equivalent to 400 days at 176 °F (80 °C) for breaking strength,
elongation, tear strength, ozone and puncture resistance
2 Approximately equivalent to 14,000 hour exposure at 0.35 W /m i rradiance B.P.T. is black panel temperature
Form # PDS- TPO -01
Date 01/01/2006
MULE -HIDE PRODUCTS CO., INC.
P.O. Box 1057, Beloit, WI 53512 -1057 • 608/365 -3111 • Fax: 608/365 -7852
•
PRODUCT DATA SHEET
MULE -HIDE TPO -c MEMBRANE
(Standard and FR)
SYSTEM BENEFITS
• Wide window of weldability
• Outstanding puncture resistance
• Chlorine -free with no halogenated flame retardants
• Excellent low temperature impact resistance
• Excellent chemical resistance to acids, bases, restaurant oils and greases
• Plasticizer -free, does not contain liquid or polymeric plasticizer
• Exceptional resistance to solar UV, ozone and oxidation
• Low vapor permeance and water absorption
• Polyester reinforcing fabric which is resistant to degradation by bacteria, mildew and fungi
• TPO -c is 100% recyclable
CODE APROVALS
FM Class 1 - 90 and UL Class A classifications available. Contact Mule - Hide for other available rated assemblies.
INSTALLATION INSTRUCTIONS
(1) Approved insulation shall be mechanically attached with its largest dimensions perpendicular to the direction of the
membrane seams where possible. (2) For mechanically attached systems, perimeter sheets will be installed in an
approved pattern along all exterior roof edges. (2.a.) Mechanical fasteners and plates are installed in the seams of both
the perimeter sheets and field sheets, insulation and into the roof deck. Minimum penetrations for various decks are:
metal - 1/2 ", wood - 1 -1/2" and concrete - 1 -1/4" to 1 -1/2 ". Contact Mule -Hide for application over deck types not listed.
(3) For fully adhered systems, perimeter sheets are not required. (3.a.) The membrane is required to be mechanically
attached only at the base of all vertical surfaces, roof edges, and angle changes. (3.b.) The field of the roof is fully
adhered to the substrate with Mule -Hide TPO Bonding Adhesive. (4) For hot air welding, the membrane shall be
overlapped over the fasteners and hot air welded. All welded seams must be probed. (5) All details will be done in
accordance with Mule -Hide details. (6) On projects where a Mule -Hide Standard or Premium Warranty is requested, an.
authorized Mule -Hide representative shall inspect all completed work. This is only a brief summary and not the complete
specification. The Mule -Hide TPO Specifications, Details, Technical Bulletins, associated documents should be
thoroughly reviewed prior to starting any project.
SUPPLEMENTAL APPROVALS, STATEMENTS AND CHARACTISTICS:
1) TPO -c meets and exceeds the requirements of ASTM 06878 Standard Specification for Thermoplastic
Polyolefin Based Sheet Roofing
2) Radiative Properties for ENERGY STAR ®, Cool Roof Rating Council (CRRC) and LEED
TEST METHOD WHITE TAN GRAY
TPO -c TPO-c TPO-c
ENERGY STAR® initial solar reflectance Solar Spectrum 0.87 0.68 N/A
Reflectometer
ENERGY STAR® solar reflectance after 3 Solar Spectrum
years Reflectometer (after 0.83 0.64 N/A
cleaning)
CRRC initial solar reflectance ASTM C1549 0.79 0.66 0.26
CRRC solar reflectance after 3 years ASTM C1549 (uncleaned) Pending Pending Pending
CRRC initial thermal emittance ASTMC1371 0.90 0.89 .089
CRRC thermal emittance after 3 years ASTM C1371 (uncleaned) Pending Pending Pending
LEED' emittance ASTM E408 0.95 0.95 .095
Form # PDS- TPO -01
Date 01/01/2006
MULE -HIDE PRODUCTS CO., INC.
P.O. Box 1057, Beloit, WI 53512 -1057 • 608/365 -3111 • Fax: 608/365 -7852
PRODUCT DATA SHEET
MULE -HIDE TPO -c MEMBRANE
(Standard and FR)
An ENERGY STAR qualified low slop roof product must have an initial solar reflectance of at least 0.65 and a
3 -year aged solar reflectance of at least 0.50. Cleaning the aged roof surface is permitted by the ENERGY
STAR test protocol.
The Cool Roof Rating Council (CRRC) does not specify minimums for reflectance or emittance but they do
require specific protocols for testing and reporting. Cleaning of the aged roof surface is not permitted for
determination of radiative properties after 3 years.
A LEED "point" may be earned if a roof material is ENERGY STAR qualified and has a thermal emittance of at
least 0.90 as determined by ASTM E408.
3) TPO-c membranes conform to requirements of the U.S.E.P.A. Toxic Leachate Test (40 CFR part 136)
performed by an independent analytical laboratory.
4) TPO-c was tested for dynamic puncture resistance per ASTM D5635 -04 using the most recently modified
impact head. 45 -mil was watertight after an impact energy of 12.5 J (9.2 ft-lbf) and 60 -mil was watertight after
22.5 J (16.6 ft-lbf)
TECHNICAL SERVICES
Contact Mule - Hide Products Co., Inc. at 608/365 - 3111 for technical service information.
DISCLAIMER
The statements provided concerning the material shown are intended as a guide for material usage and are believed to be true and
accurate. No statement made by anyone may supersede this information, except when done in writing by Mule -Hide Products Co., Inc.
Since the manner of use is beyond our control, Mule -Hide does not make nor does it authorize anyone to make any warranty of
merchantability or fitness for any particular purpose or any other warranty, guarantee or representation, expressed or implied, concerning
this material except that it conforms to Mule- Hide's physical properties. Buyer and user accept the product under these conditions and
assume the risk of any failure, any injury of person or property (including that of the user), loss or liability resulting from the handling,
storage or use of the product whether or not it is handled, stored or used in accordance with the directions or specifications. Mule -Hide
must be notified in writing of any claims and be given the opportunity to inspect the complaint or failure before repairs are made.
Form # PDS- TPO -01
Date 01/01/2006
MULE -HIDE PRODUCTS CO., INC.
P.O. Box 1057, Beloit, WI 53512 -1057 • 608/365 -3111 • Fax: 608/365 -7852