Loading...
Permit CI1YOFTIGARD A � r , DEVELOPMENT SERVICES BUILDING PERMIT 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639-0171 PERMIT S BUF 88 - 0431 DATE ISSUED: 10/01/98 PARCEL: 1S136CD -00200 SITE ADDRESS...: 11705 SW PACIFIC HWY #L SUBDIVISION • ZONING:C —G BLOCK • LOT • JURISDICTION:TIG REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION — CLASS OF WORK.:ALT FIRST • 8647 sf N: S: E: W: TYPE OF USE...:COM SECOND...: 0 sf PROTECT OPENINGS? TYPE OF C0NST.:5N .... 0 sf N: S: E: W: OCCUPANCY GRP.:M TOTAL . 8647 sf ROOF CONST: FIRE RET ?: OCCUPANCY LOAD: 248 BASEMENT.: 0 sf AREA SEP. RATED: STOR.: 0 HT: 0 ft GARAGE...: 0 sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD • 0 psf LEFT: 0 ft RGHT: 0 ft FIR SPKL: SMOK DET..: DWELLING UNITS: 0 FRNT: 0 ft REAR: 0 ft FIR ALRM: HNDICP ACC: BEDRMS: 0 BATHS: 0 IMP SURFACE: 0 PRO CORR: PARKING: 0 VALUE. $ : 75000 Remarks : Big 5 Sporting Goods TI - construct 1-hr storage separation wall upgrade restroous exit signs, exit ilium. A elec, leech and plbg permit is req'd. Also, a rack storage permit is req'd. Owner: FEES WYSE INVESTMENT SERVICES type amount by date recpt 200 MARKET STE 345 PRMT $ 358.00 JSD 10/01/98 98- 309639 PORTLAND OR 97201 5PCT $ 17.90 JSD 10/01/98 98- 309639 PLCK $ 232.70 JSD 10/01/98 98- 309639 Phone #: 294 -0400 FIRE $ 143.20 JSD 10/01/98 98- 309639 Contractor: NORTHWEST GENERAL CONTRACTORS 1328 NW KEARNEY PORTLAND OR 97209 Phone #: 222 -3834 $ 751.80 TOTAL Reg #..: 105412 -- REQUIRED ACTIONS or INSPECTIONS--- - This permit is issued subject to the regulations contained in the Framing Insp Tigard Municipal Code, State of Ore. Specialty Codes and all other F i r e wa l l Insp applicable laws. All work will be done in accordance with Gyp Board Insp approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001 -0010 through OAR 952 - 00101987. You .any obtain a copy of these rules or direct questions to OUNC by calling (503)246 -1987. Permittee Signatu < d By: !�! 401 +++++++++++++++++++++ + +++ +t+ ++++++ + + ++++++ ++ ++++++tt++++ ++ ' tt +++ +i ++++ + ++++ Call 639 -4175 by 7:00 p.m. for an inspection needed the next business day X6,0/ e CITY OF TIGARD Commercial Building Permit Application Recd By \ Date Recd (0 -d/ -4 / ' 13125 SW HALL BLVD. • Tenant Improvement Date to P.E. TIeARD, OR 97223 CI" C Date to DST /v /I / s9 4-v4. (503) 639 -4171 Permit # Print or Type Related S 9 �� �� Incomplete or illegible applications will not be accepted Called N e o o I Existing Building New Building ❑ Job Pi,,G! /. CAoss Ke"Ds rm.., Address Street Address Suite Building I ric5 emrl,'w , 1— Data kETos\ L Bldg # City /State Zip Existing Use of Building or Property: - 1 1 5 4 4.0 \ oe, g72: • 1Z6.- -F,, L - Name a Proposed Use of Building or Property: Property rty (At yst, I N u 1 `s�h� e,.it Sta.t■ c,dS Owner Mailing Address Suite I 200 in Re. )Cel 3 Lir No. Of Stones: City/State Zip Phone P O ' ( t D , O `7 j Z o j 2-9 y -O 1 /0® Sq. Ft. Of Project: Occupant Name . I O 006 1316- s SP t Cocos Occupancy Class(es) Name Contractor N &A.'. coo, .0c,. Type(s) of Construction Prior to permit Mailing Address Suite issuance, a copy , this project have a Fire Suppression System? of all licenses ] 3Z$ ()t*1 1<[z. Yes ❑ No) are required if City/State Zip Phone Americans with Disabilities Act (ADA) in C.O.T. ( ) database el Oe. /7 . Z2.2 7 Valuation X 25% = $ Participation Oregon Const. Cont. Board Lic.# Exp. Date Complete Accessibility Form 106 12, 3 Project $ Name Valuation 7,5; ©0 v Architect LA i pe N f R, / Pita c 4)7'12 Plans Required: See Matrix for number of sets to submit Mailing Address Suite on back 1833 \S °cio gt" City/State Zip Phone I hereby acknowledge that I have read this application, that the information 1 '8 13 given is correct, that I am the owner or authorized agent of the owner, and C71-.L Cktat ' GI\ 47 1 i lO 2N c- 60$6 that plans submitted are in compliance with Oregon State Laws. Engineer Name Signature of Owner/Agent Date Mailing Address Suite � v, / /INA�LIC 9 - 3 0- G� � (y Contact Pers a Name Phone City /State Zip Phone R0814 C_. lvo/Le s z-2. 3 g 311 FOR OFFICE USE ONLY Indicate type of work: New 0 Addition 0 Demolition 0 Map/TL# Land Use: Accessory Structure 0 Foundation Only 0 Alteration /` 1 Repair 0 Other 0 Notes: Description of work: 7:1*- TIF: ., Note: Site Work Permit Application must precede or accompany Building Permit Application r g6 I: \COMNEWTI.DOC (DST) 5/98 COMMERCIAL PLAN SUBMITTAL REQUIREMENT MATRIX '"".""""--"""" ".""""•:*:•:•:•:'• .supovising.::;eiectrtelaritefateiltilafffeiiiefit will be conducted Cit After plan revtew approval, Hans Examiner will contact the appitcant to request additional plan sets for disthbution purposes (Copy fr Contraotor "'"""""""'""""'""""'""'"' Washington County, Tualattn Valley Fire & Rescue) Total of KEY: SubmLtted • S (Private) 1 S = Site Work B (New or Add) 1 B = Building F (New or Add or Alt) 3 F = Fire Protection System M (New or Add or Alt) 1 M = Mechanical B & M (New or Add) 1 P = Plumbing P (New, Add, or Alt) 2 E = Electrical B & M & P (New or Add) 2 New = New Building E (New, Add, or Alt) 2 Add = Addition B & F & M & P & E 3 Alt = Alternation to Existing (New , Add) Building ............. ............ ............... ...... • ...... . . . 7.. . . . . . NOTES: ................................ I: \dsts\maxtrixl.doc 07/06/98 Oci29-98 04:40A adt 2133870858 P.01 •cp P ,A Security • Services, Inc, B 0 y'e q 3 f TELEFAX TRANSMISSION COVER PAGE DATE: FAX TO: C 7.? 97 FROM: DATA BASE DEPT-LAWN DALE FAX#310-725-2509 NUMBER OF PAGES: COMMENTS: - 5Paa, 0 &Arr H f S le)1 'Oct\ -- 29 - 98 04:40A adt 2133870858 P_02 Event History Display CS -007 CS # 8370120966 SIG 5 SPORTING GOODS #233 Dispatch Codes: 11705 S W PACIFIC HIGHWAY L_ As Of: 10/29/98 11:37 Zn/ ..Date.. ..Time.. Trans Acct Op Code Descr PIC /Com St 10/29/98 11:20:54 25 2000 RESTORE *L T ZONE COMMENT 125 FRONT MFA 10/29/98 11:20:52 25 45 FIRE - MANUAL PULL *B *1ST T ZONE COMMENT 125 FRONT MFA 10/29/98 11:20:04 LT 2000 RESTORE *L T ZONE COMMENT TELCO FAIL 10/29/98 11:20:00 9 2000 RESTORE, *L T ZONE COMMENT 109 STOCKROOM MFA 10/29/98 11:19:54 9 45 FIRE - MANUAL PULL *B *1ST T ZONE COMMENT 109 STOCKROOM MFA 10/29/98 11:19:40 LT 7663 LINE FAULT *A T ZONE COMMENT TELCO FAIL 10/29/98 11:18 :15 COMMENT ADW:LELAND ON TEST FOR FIRE INSP 10/29/98 11:18:15 ADW 4210 PLACE ON TEST CAT: 4 10/29/98 11:18:15 COMMENT 102998 1118* 102998 1500 N'ext, M'ore, P'rev #, D'isp, G'en, CW'indow • • • 4 actC29 -98 04:40A adt 2133870858 P.03 Event History Display CS -007 CS # B370120966 BIG 5 SPORTING GOODS #233 Dispatch Codes: 11705 S W PACIFIC HIGHWAY As Of: 10/29/98 11:37 , 'Zn/ ..Date.. ..Time,. Trans Acct. Op Code Descr PIC /Com St 10/29/98 11:36:52 LT 2000 RESTORE *L T ZONE COMMENT TELCO FAIL 10/29/98 11:36:11 LT 7663 LINE FAULT *A T ZONE COMMENT TELCO FAIL 10/29/98 11:24:51 19 2000 RESTORE *L T ZONE COMMENT 119 SALES SMOKE CNTR 10/29/98 11:24:49 19 54 FIRE - SMOKE DET *B *1ST T ZONE COMMENT 119 SALES SMOKE CNTR 10/29/98 11:23:36 35 2000.RESTORE , *L T ZONE COMMENT 135 SALES SMOKE S/E 10/29/98 11:23:34 35 54 FIRE - SMOKE DET *B *1ST T ZONE COMMENT 135 SALES SMOKE S/E 10/29/98 11:21:55 38 2000 RESTORE *L T ZONE COMMENT 138 SALES MFA S/W 10/29/98 11:21:51 38 45 FIRE - MANUAL PULL *B *1ST T ZONE COMMENT 138 SALES MFA S/W N'ext, M'ore, P'rev #, D'isp, G'en, CW'indow • • CITY OF TIGARD Date Rec'd: COMMERCIAL TENAJ IMO'ROVEMENT Rec'd By: APPLICATION /PLANS SUBMITTAL REQUIREMENTS Applicants: Please complete �r APPLICANT APPLICANT NAME: Pc r) D P.ES PHONE #: Zi-3g3 SITE ADDRESS: 1005 SW PAe.., Fvc- FAX # ZZZ -3s1 l 1. A. SITE PLAN (Fully dimensional, drawn to scale) labeled with: ❑ map & tax lot #, ❑ project name, ❑ site address, ❑ suite number ❑ zoning, ❑ applicant name, ❑ phone number. B. North Arrow. C. Scale (Any standard, architectural or engineering only). D. Street Names. 2. See Matrix on back of Application for number of plans required based on submittal type. ALL DETAILS LISTED BELOW SHALL BE INCORPORATED INTO THE PLANS A. FLOOR PLAN(S). B. WALL DETAIL. C. REFLECTIVE CEILING PLAN. D. SEISMIC BRACING DETAIL FOR SUSPENDED CEILING. E. SPECIFICATIONS & CALCULATIONS. F. ADA BARRIER REMOVAL WORKSHEET. G. DEPOSIT - BASED ON VALUATION OF PROJECT. CITY OF TIGARD 1:SFAPP.DOC (DST) 8/97 A • SUBJECT: ACCESSIBILITY BARRIER REMOVAL IMPROVEMENT PLAN REQUIREMENT: OREGON REVISED STATUTE (ORS) 447.241. (1) Every project for renovation, alteration or modification to affected buildings and related facilities shall be made to insure that the path of travel to the altered area and the restroom, telephones and drinking fountains are readily accessible to individuals with disabilities, unless such alterations are disproportionate to the overall alterations in terms of cost and scope. (2) Alterations made to the path of travel to an altered area may be deemed disproportionate to the overall alteration when the cost exceeds twenty-five percent (25 %). VALUATION of all renovation, alteration or modification being done excluding painting, wallpapering. [1] $ 7 0; 0 0 0 multiply: 25% Barrier removal requirement. .25 BUDGET FOR BARRIER REMOVAL [2] $ In choosing which accessible elements to provide under this section, priority shall be given to those elements that will provide the greatest access. Elements shall be provided in the following order: (a) Parking $ • (b) An accessible entrance: $ (c) An accessible route to the altered area: $ (d) At least one accessible restroom for each sex or a single unisex restroom: $ (e) Accessible telephones: $ (f) Accessible drinking fountains: and $ (g) When possible, additional accessible elements such as storage and alarms: $ TOTAL: Shall equal line 2 of value computation $ I OVER - THE - COUNTER (OTC) PERMIT COMMERCIAL ( STRUCTURAL) BUILDING PERMIT CHECKLIST DESCRIPTION OF PROJECT: ,e7I7J t /'i4 / rz r< • tips', ? L1,d / r . fr. e t e Yrl � Yd 6An f /EL t �' . I 11), f , f->(% �— l l Ltm 4 G ) / J L / v AP 4-e k 4 7_ l 1 c 7! L G/ T r� s 7G f� s /f �eY 07-1 7 T . CLASS OF WORK: - AL �' FLOOR AREAS: ez 7 EXTERIOR WALL CONSTRUCTION TYPE OF USE: ( FIRST SQ. FT. N: S: E: W: TYPE OF CONSTR: SECOND SQ. FT. PROTECT- OPENINGS ?: OCCUPANCY GRP: 017 tr THIRD SQ. FT. N: S: E: W: OCCUPANCY LOAD: e XLI TOTAL SQ. FT. ROOF CONSTR: FIRE RET: STOR: HT: FT: i BSMNT: SQ. FT. AREA SEP. RATED: . BSMNT ?: MEZZ ?: i GARAGE: SQ. FT. OCCU.SEP.RATED: FIRE FIRE SMOKE HANDICAP SPRINKLER: ALARM: DETECTOR: ACCESS: COMMERCIAL.. INSPECTION ACTIONS FEE MENU D'Q Foot/Found Post/Beam $ 33 P Permit Fee 7 Masonry Framing $ 2 -l7. Plan Review Insulation Shear Wall $ 1 7 5% State Surcharge 20 Firewall —7 Gyp Board $ I y 3 --- FLS Plan Review Suspended Ceiling Sprinkler Rough -in $ Add'I Permit Fee Sprinkler Final Fire Alarm $ Add'I FLS Pln Smoke Detector Approach /Sidewalk • $ Inspection Miscellaneous p Final • • $ MIS Fee po FOR OFFICE USE ONLY: TYPE OS USE OPTIONS (COM= commercial; CMS = commercial manufactured structure) CLASS OF WORK OPTIONS FOR ALL PERMITS (NEW =new; Add = addition; ALT= alteration; ACS= accessory;FND. foundation; OTR= other; DEM= demolition; REP= repair; FPS =fire protection system, NOTE: USE OTR FOR FENCES, RETAINING WALLS, DETACHED DECKS, SIGNS, AWNINGS, CANOPIES) I: \ovrcntr2.doc (DST) 4/97 OVER THE COUNTER (OTC) • (attachment to Submittal Criteria) SUBJECT: ACCESSIBILITY • BARRIER REMOVAL IMPROVEMENT PLAN REQUIREMENT: OREGON REVISED STATUTE (ORS) 447.241. (1) Every project for renovation, alteration or modification to affected buildings and related facilities shall be made to insure that the path of travel to the altered area and the restroom, telephones and drinking fountains are readily accessible to individuals with disabilities, unless such alterations are disproportionate to the overall alterations in terms of cost and scope (2) Alterations made to the path of travel to an altered area may be deemed disproportionate to the overall alteration when the cost exceeds twenty-five per -cent (25 %). THEREFORE; Each submittal for a building permit shall include this form providing the following information. [Excluding re- roofing, mechanical and electrical permit applications] VALUATION of all renovation, alteration or modification being done excluding painting, wallpapering. [1] $ 73 o multiply: 25% Barrier removal requirement. _ .25_ BUDGET FOR BARRIER REMOVAL [2] $ f 4e ? Sv The dollar amount of the BUDGET established on line (2) in the computation above shall be spent • providing the accessible elements in the following order. 1. An accessible route connecting the building to accessible pedestrian walkways, and the public way. $ (including but not limited to curb ramps, detectable warnings, marked crossings, ramps handrails and landings). 2. Not less than one accessible parking space. $ 60 o (including but not limited to adjacent access aisle, signs and curb ra connecting with the accessible route). 3. Accessible entry or entries. $ .(including but not limited to ramps, handrails, landings, door sill height, door width and door hardware). 4. An accessible interior route to the altered area. $ . (including but not limited to door -ways, maneuvering dearances, door hardware and. stairways). 5. At least one accessible restroom for each sex. $ l 6. At least one accessible telephone where public phones are provided. $ 7. When drinking fountains are required, fifty per -cent but I Se a not less than one shall be accessible. $ j 8. Additional accessible elements such as storage, reach. ranges, So v alarms, etc.. .TOTAL; Shale li 2 o Value Computation $ I e) cl is /otc4.doc(DST) • 3/7/00 Activities for Case #: BUP98 -00431 8:45:30 AM Assigned Hold Updated • Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes BUPC005 APPlication received • 10/1/98 JSD PASS JSD 10/1/98 BUPC008 Permit created 10/1/98 JSD PASS JSD 10/1/98 . BUPC012 Plans routed to Plans Examiner 10/1/98 JSD PASS JSD 10/1/98 BUPCO24 Plans Approved by CPE 10/1/98 JHF PASS JSD 10/1/98 BUPCO26 Approved Plans routed to DSTs 10/1/98 JHF OTC JSD 10/1/98 BUPC740 Framing Insp 10/7/98 RC FAIL. - ROC 10/9/98 1. NEED TO REROUTE OR . PROVIDE BACKING FOR EXISTING ELEC. 2. MECH. DUCTS PASSING THROUGH WALL MUST BE 26 GA. . METAL AND DAMPERED 3. PLASTIC ELEC CONDUIT WILL NEED TO BE PROTECTED . 4.INSUL ON • - COPPER PIPE MUST BE • • REMOVED WHERE PASSING . THROUGH WALL BUPC760 Gyp Board Insp 10/15/98 RC PART J'H 10/19/98 Store side of 1 -hour wall to bottom of trusses. BUPC802 Final Inspection 10/29/98 RC PASS J *H 11/2/98 mech, plmb, elec, and rack storage permit required. Check on these permits before building final. Jeanne T. SEE • LOG NOTES 110298/jh BUPC758 Firewall Insp 10/1/98 10/22/98 RC FAIL ROC 10/23/98 1. TAPE AND MUD MUST BE REMOVED FROM FIRE • CAULK FOR INSPECTION. 2. INSUL M,UST BE REMOVED FOR FIRECAULK INSPECTION. • BUPC100 (F) Issue permit • 10/1/98 JSD PASS , JSD 10/1/98 BUPC740 Framing Insp 10/15/98 10/14/98 RC PART J *H 10/15/98 Framing to bottom of truss. Need electrical mechanical inspector before framing. BUPC740 Framing Insp 10/21/98 10/21/98 RC FAIL J'H 10/21/98 1. Need electrical approval of bathroom walls. Storage side • of 1 -hr. wall taped without inspection. 2. Office wall covered without inspection. 3. • Replace insulation in ceiling. 4. Need inspection on ceiling grid before placing tile. 5. 1 -hour . walls above trusses covered without framing inspection. 6. Need maechanical inspection before setting tile. • Page 1 of 2 - 3/7/00 Activities for Case #: BUP98 -00431 8:45:30 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes BUPC760 Gyp Board Insp 10/21/98 10/22/98 RC • PART ROC 10/23/98 ALL WALLS EXCEPT • BATHROOM. OUTSIDE OF BATHROOM WALL ONE SIDE OF PLUMBING WALL TO 4' ONLY BUPC762 Susp Ceilng Insp 10/21/98 10/22/98 RC FAIL ROC 10/23/98 STRUTS AND SPLAYS MUST BE WITHIN 6' OF EVERY WALL SPLAYS MUST BE • TAUNT AND AT LEAST 45 DEGREE FROM VERT. OK TO PLACE TILES IN CEILING • EXCEPT WHERE NECCESSARY FOR INSPECTION. BUPC762 Susp Ceilng Insp 10/21/98 10/26/98 RC PASS J *H 10/27/98 BUPC740 Framing Insp 10/21/98 10/22/98 RC PART • ROC 10/23/98 ALL WALLS EXCEPT BATHROOM WALL BATHROOM WALL HAS NOT HAD PLUMBING APP. OK TO SHEETROCK BOTTOM 4'ON ONE SIDE ONLY. BUPC740 Framing Insp • 10/23/98 RC PASS J *H 10/23/98 bathroom framing BUPC740 Framing Insp 10/26/98 RC PASS J *H 10/27/98 BUPC070 HOLD FOR (Note in Action Memo) 11/6/98 JMT NOTE • JT 11/6/98 holding C /O, e1c98 -0619 has • not been approved. e-mail to • Chuck, please let me know when its approved. Jeanne T. • BUPA865 Request inspection research 2/14/00 JMT DONE No Hold JMT 2/14/00 e1c98 still not approved. second research request sent BUPC950 (F) Issue Cert. of Occupancy 10/28/98 RC DONE No Hold JMT 3/2/00 • • • Page2of2 - 02/14/2000 Activities for Case #: BUP98 -00431 3:51:06 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes BUPC005 Application received 10/01/1998 JSD PASS JSD 10/01/1998 BUPC008 Permit created 10/01/1998 JSD PASS JSD 10/01/1998 BUPC012 Plans routed to Plans Examiner 10/01/1998 JSD PASS JSD 10/01/1998 BUPCO24 Plans Approved by CPE 10/01/1998 JHF PASS JSD 10/01/1998 BUPCO26 Approved Plans routed to DSTs 10/01/1998 JHF OTC JSD 10/01/1998 BUPC740 Framing Insp 10/07/1998 RC FAIL ROC 10/09/1998 1. NEED TO REROUTE OR PROVIDE BACKING FOR EXISTING ELEC. 2. MECH. DUCTS PASSING THROUGH • WALL MUST BE 26 GA. METAL AND DAMPERED 3. PLASTIC ELEC CONDUIT WILL NEED TO BE • PROTECTED . 4.INSUL ON COPPER PIPE MUST BE REMOVED WHERE PASSING THROUGH WALL BUPC760 Gyp Board Insp 10/15/1998 RC PART J *H 10/19/1998 Store side of 1 -hour wall to bottom of trusses. BUPC802 Final Inspection 10/29/1998 PASS J *H 11/02/1998 mech, plmb, elec, and rack storage permit required. Check on these permits before building final. Jeanne T. SEE LOG NOTES 110298Tjh BUPC758 Firewall lnsp 10/01/1998 10/22/1998 RC FAIL ROC 10/23/1998 1. TAPE AND MUD MUST BE REMOVED FROM FIRE CAULK FOR INSPECTION. 2. INSUL M,UST BE REMOVED FOR FIRECAULK INSPECTION. BUPC100 (F) Issue permit 10/01/1998 JSD PASS JSD 10/01/1998 BUPC740 Framing Insp 10/15/1998 10/14/1998 RC PART J *H 10/15/1998 Framing to bottom of truss. Need electrical mechanical inspector before framing. BUPC740 Framing Insp 10/21/1998 10/21/1998 RC FAIL J *H 10/21/1998 1. Need electrical approval of bathroom walls. Storage side of 1 -hr. wall taped without inspection. 2. Office wall covered without inspection. 3. Replace insulation in ceiling. 4. Need inspection on ceiling grid before placing tile. 5. 1 -hour walls above trusses covered without framing inspection. 6. Need maechanical inspection before setting tile. • Page 1 of 2 "' )2/14/2000 Activities for Case #: BUP98 -00431 I t 7 5 Igaz 3:51:06 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes BUPC760 Gyp Board Insp 10/21/1998 10/22/1998 RC PART ROC 10/23/1998 ALL WALLS EXCEPT BATHROOM. OUTSIDE OF BATHROOM WALL ONE SIDE OF PLUMBING WALL TO 4' ONLY BUPC762 Susp Ceilng Insp 10/21/1998 10/22/1998 RC FAIL ROC 10/23/1998 STRUTS AND SPLAYS MUST BE WITHIN 6' OF EVERY WALL SPLAYS MUST BE TAUNT AND AT LEAST 45 DEGREE FROM VERT. OK TO PLACE TILES IN CEILING EXCEPT WHERE NECCESSARY FOR INSPECTION. BUPC762 Susp Ceilng Insp 10/21/1998 10/26/1998 RC PASS J *H 10/27/1998 BUPC740 Framing Insp 10/21/1998 10/22/1998 RC PART ROC 10/23/1998 ALL WALLS EXCEPT BATHROOM WALL BATHROOM WALL HAS NOT HAD PLUMBING APP. OK TO • SHEETROCK BOTTOM 4'ON ONE SIDE ONLY. BUPC740 Frami : sp 10/23/1998 RC PASS J'H 10/23/1998 bathroom framing BUPC740 -ming Insp 0/26/1998 RC PASS J *H 10/27/1998 BUPe 070 HOLD FOR (Note in Action Memo) 11/0. • •98 JMT NOTE JT 11/06/1998 holding C /O, e1c98 -0619 has not been approved. e-mail to • Chuck, please let me know . when its approved. Jeanne T. BUPA865 Request inspection research 02/14/2000 JMT DONE No Hold JMT 02/14/2000 eIc98 still not approved. second research request sent . 5 is IrvaL °` C tx pi it KJ% 0 ( • 5-k4ik5 . a. c 1 up 1 6r C't . '55oV' GobdS r I 9 Gb(ec 0 . t tc Page 2 of 2 I CITY OF TIGARD BUILDING INSPECTION DIVISION MST �p / 4-Hour Inspection Inspection Line: 639 -4175 Business Line: 639 -4171 A �, D �/ �`f� l �(� Date Requested lio -cl - q AM BLD Location // 05 65( i 4 Suite v MEC Contact Person � � X /IN // Ph � AM 4.- Contractor �lf /� Ph .0. � SWR UILDINGD Tenant/Owner ? ELC Retaining Wall ELR Footing Access: �� �, / / n Foundation ` fyk. a a 1 401 FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc OW PART FAIL - 1 MBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Q Other Date 4 a9 r O Inspector / Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.