Loading...
Permit r • �sZ r PERMIT #: BUP1999 -00261 - 13125 ���4 . DEVE PMENT r S o ERV IICES 639 -4171 DATE ISSUED: 09/27/1999 SITE ADDRESS: 11705 SW PACIFIC HWY* PARCEL: 1S136CD 00100 SUBDIVISION: t� I1,�. ZONING: C - BLOCK: LOT: ` JURISDICTION: TIG REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: ALT FIRST: 1,870 sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 5 - HR : sf N: S: E: W: OCCUPANCY GRP: M TOTAL AREA: sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: 45 BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: N SMOK DET:N DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : N HNDICP ACC:Y BEDRMS: BATHS: IMP SURFACE: PRO CORR: N PARKING: VALUE: IN 21Q;490 ......../ Remarks: Commercial TI. Owner: Contractor: WYSE INVESTMENT SERVICES PYRAMID DEVELOPMENT & CONSTRUC 200 SW MARKET ST STE 345 13217 NE 54TH PL PORTLAND, OR 97201 BELLEVUE, WA 98005 Phone: 294 -0400 Phone: 425 -861 -6990 Reg #: LIC 124929 FEES REQUIRED INSPECTIONS Type By Date Amount Receipt Electrical Permit Required PLCK DEB 01/09/199, $110.83 99- 316228 Plumbing Permit Required Framing Insp FIRE DEB 01/09/199 $68.20 99- 316228 Gyp Board Insp PRMT KJP 09/23/199. $170.50 99- 318562 Final Inspection 5PCT KJP 09/23/199 $8.53 99- 318562 (additional fees not listed here) Total $608.06 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -1987. You may obtain a copy of these rules or direct questions to OUNC by calling (503) 246 -1987. Permitee Si • atu ��L/' , �_ : f ice .. -- IsuedBy: / iJ '� - (12.-41/1-4 Call 639 -4175 by 7 p.m. for an inspection the next business day O4/99 1101' 14:11 FAX 503 5 911 1960 CITY OF' TIGARD 071 - ti O F TIGARD Commerc Building Permit Application Plan Check # _e 6 c X125 SW HALL BLVD. Tenant Improvement Recd By . TIGARD, Of;: 97223 Date Rec'd . CO / — 99 (503) ' 3y -4171 Date to P.E. (/ �lY _ Date to DST 7,4- I qei r9 Print or Type Permit# R .iPlg9q- oeia4/ Q ,o9 -cxxo 7 Related SWR # Incomplete or illegible applications will not be accepted Called Name of Development/Project Existing Building New 13uilding ❑ Job T<fi -010 ') Address Street Address ' Suite Building 7e7 S Zibi-\10-, ---- Data • Bldg # City /State Zip Existing Use -'of Building cc Property: T ', Di v . ei7223 . Q Name / I �eT lr Ivf- Property . ,, — ----- Proposed Use of Building or Property: Owner Mailing Address Suite ' � L Op F, • 200 kAl. At T ht ' 3 5 N. Of Stories: ©hlr City /State Zip Phone o rJ OR • (0b3) 21f D / Sq. Ft. Of Project: Occupant Name ` 1, S� � 01G2 & Occupancy Class(es) Name 1 ` `�GAll 71 L C/vt d:.; �. . i s Contractor • - - - - -- ' -'•_ ly M ►b .1� J� ed Type(s) of Construction Prior to permit Mailing Addres Suite 114/2-. issuance, a copy / 3,p /7 Ali Y PZ. Will this project have a Fire Suppression System? of all licenses Yes ❑ No are required if City /State Zip Phone expired in c.o.T. Americans with Disabilities Act (ADA database tl,C- (,( i„ � 7 = gce d- /r (j Valuation X 25% = $ - rticipation 4,6 Z ) Oregon Cg_nst, ppnnt. Board Lic.# p. Date, • _ Complete Accessibility Form `(yf c Ci V. 'OC) Project $ Name Valuation 5000 Architect T-Ir& A. f) FILE) Ill - Plans Required: See Matrix for number of sets to submit Mailing Address Suite on back City/State Zip hon I hereby acknowledge that I have read this application, that the information y �� given is correct, that I am the owner or authorized agent of the owner, and �� tk Tl4 f / T _ 4 Engineer t ineer ' ` submi d are i compliance with Oregon State Laws. ' ►, . ign ; r '.f Own r /Agi Date / Mailing Address • Suite allif Contact i ontact Per on Name Phone City /State Zip Phone I i Lr 1 L. . •` /� 5 ` 3)v CX� ✓ - p p 7- 1 9 . 24 1 FOR OFFICE USE ONLY Indicate type of w( rk: New 0 Addition 0 Demolition 0 Accessory Structur( 0 Foundation Only 0 Alteration O Mapi/TL# _ Land Use: . /P�3c -oofoo _ Repair 0 Other 0 • Description of wort: Note: .too l..- e-in NC- -17)(e_ F- TIF - Note: Site Work Perrr'It Application must precede or accompany Building ---,-,.0 PC- �' V b Permit Application r z___6 / k\COMNETI.DOC (DST) 5/98 ` 7 4'3 W • 11/09/1999 Activities for Case #: BUP1999 -00261 10:51:24 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes BUPC005 Application received 06/18/1999 DEB DONE No Hold DEB 06/25/1999 BUPC008 Permit created 06/25/1999 DEB DONE No Hold DEB 06/25/1999 BUPC012 Plans routed to Plans Examiner 06/25/1999 DEB DONE No Hold DEB 06/25/1999 BUPC015 Plan Review Ltr. to Ofc. Svcs. 06/29/1999 RDP DONE No Hold RDP 06/29/1999 Sent out 6/29/99 BUPC018 Revised Plans Received 08/24/1999 RDP DONE No Hold RDP 08/24/1999 BUPCO24 Plans Approved by CPE 08/24/1999 RDP DONE No Hold RDP 08/24/1999 BUPCO22 Plans Approved /Routed to DSTs 08/24/1999 RDP DONE No Hold RDP 08/24/1999 BUPC530 Electrical Permit Required 08/24/1999 08/24/1999 No Hold RDP 08/24/1999 BUPC565 Plumbing Permit Required 08/24/1999 08/24/1999 No Hold RDP 08/24/1999 BUPC740 Framing insp 08/24/1999 08/24/1999 10/05/1999 TLP PASS No Hold AKJ 10/05/1999 approved contingent upon elec cover app BUPC760 Gyp Board lnsp 08/24/1999 08/24/1999 10/07/1999 RB PASS No Hold AKJ 10/07/1999 tighten nailing to 12" oc and secure where missed BUPC799 Final Inspection 10/25/1999 RB FAIL No Hold RB 10/26/1999 PLM1999 -00197 sign -off req'd. ELC98 -00044 sign -off req'd ELC1999 -00274 sign -off req'd ELR ? Required. Suspended Ceiling approval in • part- BUPCO29 DST Post Review Completed 08/26/1999 BON DONE No Hold BON 08/26/1999 BUPC090 (F) Ready to issue 08/26/1999 BON DONE No Hold " BON 08/26/1999 Needs constractor identified. BUPC100 (F) Issue permit 09/27/1999 DEB DONE No Hold DST 09/27/1999 BUPC798 Misc. Inspection 09/28/1999 RB FAIL No Hold AKJ 09/28/1999 didn't specify insp, no one at site had info BUPC762 Susp Ceilng lnsp 10/14/1999 10/14/1999 10/14/1999 RB PASS No Hold DGW 10/14/1999 1. Rivet one side @ 4' intervals. 2. Hanger (fwd end) w /in 8" of end of cross runners @ each. BUPC762 Susp Ceilng Insp 10/26/1999 10/26/1999 10/25/1999 RB PART No Hold RB 10/26/1999 Sway bracing missed- at ends w /in 8" and seismic bracing at 12' intervals. Electrical lighting support req'd Remove rivots from one end and one side. Remove all wiring off of T -grid. Support/secure heat registers. BUPC762 Susp Ceilng lnsp 10/26/1999 10/26/1999 10/26/1999 RB PART . No Hold RB 10/26/1999 Incompleted issues from prior report dtd. 10 -25 -99 RB. ELR1999 -00249 sign -off req'd. Install wiring supports at ends w /in 8". Support lighting. Page 1 of 2 11/09/1999 Activities for Case #: BUP1999 -00261 10:51:24 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes BUPC802 Final Inspection 10/26/1999 10/26/1999 10/27/1999 RB FAIL No Hold RB 10/27/1999 Electrical Final Approval Required- ELC98- 00044; ELC1999- 00589; and ELR1999 -00249 need to be signed off. BUPC762 Susp Ceiing Insp 10/26/1999 10/26/1999 10/26/1999 RB FAIL No Hold JS 10/26/1999 SEE MEC1999 -00274 10/26/99. BUPC762 Susp Ceilng Insp 10/27/1999 10/27/1999 10/27/1999 RB PASS No Hold RB 10/27/1999 BUPC799 Final Inspection 10/29/1999 RB PASS No Hold VT 10/29/1999 BUPC950 (F) Issue Cert. of Occupancy 10/29/1999 TIG RB DONE No Hold JMT 11/09/1999 • Page 2 of 2 • CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 x ; � � Z © ® Date R q \ 0 17. 4 1/ AM PM BLD Location \ 1 �(N) G C C� \' 5 Suite MEC Contact Person Ph PLM Contr Ph SWR IL N :�� Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain Crawl Drain Inspection Notes: SGN Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof P �_� , ��� _ �� _ � ART FAIL PLtfMBING n Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL; ` Post & Beam Rough In Gas Line Dampers Dampers Final .(< PASS PART FAIL ELECTRICAL: ; '' Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL Backfill/Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk n Other Date b � �� Inspector v �` L E Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.