Permit 4 C ITY OF T I GA R D MECHANICAL PERMIT ; ��n, DEVELOPMENT SERVICES PERMIT #: MEC2000 -00014 -ii 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 02/18/2000 PARCEL: 1S136CD-01700 SITE ADDRESS: 11686 SW PACIFIC HWY SUBDIVISION: ZONING: C -G BLOCK: LOT: JURISDICTION: TIG CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: COM UNIT HEATERS: 2 VENT FANS: OCCUPANCY GRP: VENTS W/O APPL: VENT SYSTEMS: STORIES: BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: 1 .DOMES. INCIN: GAS 3 - 15 HP: 1 COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: REPAIR UNITS: FIRE DAMPERS ?: 30 - 50 HP: WOODSTOVES: GAS PRESSURE: 50 + HP: FURN < 100K BTU: 1 AIR HANDLING UNITS CLO DRYERS: FURN > =100K BTU: 1 < = 10000 cfm: OTHER UNITS: > 10000 cfm: GAS OUTLETS: 1 Remarks: Mechanical for new commercial retail building. Owner: FEES • P & F PROPERTIES Type By Date Amount Receipt 834 W ST CLAIRE PRMT KJP 02/18/20( $88.00 00- 321772 PORTLAND, OR 97205 PLCK KJP 02/18/20( $22.00 00- 321772 5PCT KJP 02/18/20( $7.04 00- 321772 Phone: 225 -0700 Total $117.04 Contractor: AREA HEATING INC 2721 NE 65TH AVE • VANCOUVER, WA 98661 REQUIRED INSPECTIONS ' Gas Line Insp Phone: 360 - 737 -0811 Mechanical Insp Reg #: LIC 00064801 Mechanical Insp Duct Inspection S.D. Shut -down Final Inspection ORIGINAL. .._ This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0080. You may obtai .. - of these rules or direct questions to OUNC by calling (503)24 -9189. Issue By: }- �Permittee Signature: f Call (503) 639 -4175 by 7:00 P.M. for inspections needed the next business day CITY OF TIGARD Mechacai`Permit Application Rena By # �� �oi 13125 SW HALL BLVD. Commercial and Residential Date Recd 1- / - TIGARD, OR 97223 Date to P.E. - //- '0 " (503) 639 -4171, x304 Date to DST o00� Print or Type Permit # /k"a? /y Incomplete or illegible applications will not be accepted Called 2. !7' ZED Name of DevelopmerlllProject , Description 1rVl /1 i rb I /) IJI 1, �1 ( - jil Table 1A Mechanical Code Qty Price Amt Job Str � ee l t l A A d - dffless . ese# A) Permit Fee ° <';-< 16.00 Address ( I 0 btu IJG"f L 1 1 ic. ` � 1) Furnace to 100,000 BTU 9.65 Bldg# City/State zip J including ducts & vents (! 2) Furnace 100,000 BTU+ • (l,(V U I1 vl - 0 including ducts ucts & 8 vents 1 AV 12.00 Name (or name of business) 3) Floor Furnace Owner -e-f F P(o pCill eS including vent 9.65 Mailing Address 4) Suspended heater, wall heater ,,� C G t or floor mounted heater 9.65 3 3y 11 W Sfi 5) Vent not included in appliance permit 4.75 City/State Zip M Phone Check all that apply: `Boiler Heat Air Po -- l O ` 017305 For items 6 -10, see or Pump Cond Qty Price Amt Name (or name of business) footnotes 1,2 Comp (M ( i y i.t I 1 t r i 6) Repair units 8.40 • Occupant Mailing A ress � �p / ( NWT 7) <3HP;absorb unit to 11 I D YO �i� 1 Q aCx � l C. N wT 100K BTU t 9.65 City /State I�� zip Phone 8) 3 -15 HP;absorb unit I W 6�" D` �/ q 9) 0 15 -30 HP; absorb 17.65 Contractor Nam ,�y� /' /� �1 , , unit .5-1 mil BTU 24.15 T1 t1 1 Ill't 4ODUL 10) 30 -50 HP; absorb Prior to permit Mailing Ad ress unit 1 -1.75 mil BTU 36.00 issuance, a copy Z 2.-1 NE (6 fit 11) >50HP; absorb unit >1.75 mil BTU of all licenses City /State /r A i ^ p ' ^' Phone 319 60.15 U are required if O j),DLf� Yid C Of MM '1,3 I I 12) Air handling unit to 10,000 CFM expired in COT Oregon Const. Cont. Board Lic.# p. ate 44 7.00 database lQ SO I I, t i pv v ' ' 13) Air handling unit 10,000 CFM+ Architect Name 111 11.85 R 1-}I'A,Iii' 14) Non - portable evaporate cooler Or Mailing A 7.00 Z U Z I 21 9- I P I 1 , W 1 15) Vent fan connected to a single duct • P 4.75 Engineer City/State Zip Phone 16) Ventilation system not included in f fits -f f C111 9 WeL appliance permit 7.00 Describe work to be done: 17) Hood served by mechanical exhaust 7.00 New {IC Repair 0 Replace with like kind: Yes 0 No 0 18) Domestic incinerators Residential 0 Commercial t( Modification 0 OOddd 12.00 19) Commercial or industrial type incinerator Additional information or description of work: 48.25 20) Other units, including wood stoves , • 7.00 NOTE: For Commercial projects only; Units over 400 lbs., located on the 21) Gas piping one to four outlets 1 v roof, require structural calcs. prepared by licensed engineer. 1 3.75 v Type of fuel: oil 0 natural gasAio LPG 0 electric 0 22) More than 4 -per outlet (each) .75 I hereby acknowledge that I have read this application, that the information Minimum Permit Fee $50.00 SUBTOTAL A fp given is correct, that I am the owner or authorized agent of 8 % SURCHARGE •/ „� PLAN REVIEW 25% OF SUBTOTAL " '!, the owner, that plans submitted are in compliance with Oregon State laws. Required for ALL commercial permits only Signature of Owner /Agent Date TOTAL 1 t , L ek �.1 QO,�, 30 -11. 3 0- D a ) I �a 1 3 Other Inspections and Fees: a 0 17 9 f9. oc) ,21-7 l v Y t P,4rsgn Nar p@ „� /� (� lr�(,l �'1JL l 1. Inspections outside of normal business hours (minimum charge -two hours) $50.00 per hour 2. Inspections for which no fee is specifically indicated (minimum charge half hour) $50.00perhour Foonotes for commercial projects only: 3. Additional plan review required by changes, additions or revisions to plans (minimum 1. Provide full schematic of existing and proposed gas line and pressure. charge - half hour) $50.00 per hour 2. Provide drawings to scale showing existing and proposed mechanical `State Contractor Boiler Certification required units. "Residential A/C requires site plan showing placement of unit I:\mechperm.doc rev 11/1/99 Mechanical Summary MECH - SUM INN Wr.gr. ilmordweel efaIrl Ceee oeenae Pawls dl.r. tee. Project Info Protect - l.aGtvoc ;n �: �: Dace Wry - /; o'./FG. . ,°ociAVC Hwy • For Bulking Dept. Use 7 - ; ORO a/P. APPllean! N m•ici r E - 4 Aix.01 o at C000L ;N APPS Address: 2 7.Z / N•E. !.s %.G�•tE vrl coage Appear!! Phone: 36 o_ 7� 7 - 09// Project Description ■et rofv.sr,Qvci ;v., Beefy deaerre =Chanial system N Rn' /Gas - 7/Ecoodo.tr %zt2 s . type and feabses. Compliance Option S System 0 Compls( Syatsm (3 Systems Analysis • (Se. Decision Ftowalwt (over) for qurlilkatione) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules an the plans. For projects without plans. fi in the required information beiow. Cooling Equipment Schedule Equip. OSA CFM SEER ID Brand Name' Model No.' Capacity Total CFM Econo or EER IPLV location Rh! -/ /,PRA/c CO2 s' 93LOF A.14 .ODD 7 .c.e>40 &OND ? ,3 — N. �.. ?t/. - .Z T ?a•V( Ye% c3ZOA i .2s'ODO 3•S00 & O 9.0 /y. € Heating Equipment Schedule Equip. - OSA Cam ID Brand Name' Model No.' Capacity= s To CFM Ear* Input Btuh Output Bluh Efficiency Fan Equipment Schedule Equip. - ID Brand Nance' Mode! No.' CFM SP' HP/BHP Flow Control Location d Service • 'If available. 2 As tented according to Table 141. 142 or 143. ' If required. • COP. HSPF, Combustion Efficiency. or AFUE. as applicable. Flow control types: VAV. Constant volume. or variable speed. Mechanical Summary (back) MECH =SUM • System Description it H.etkrp,C S** ' 0 Constant von. 0 Atr oecied7 O Peciapsd eys9 CI <54,000 seal? See Section 1421 for full description Silvis System of w 0 SpR spore Eaanonrbaer included? If H°° °n M 0 4s000 dm? 0 <7,0% soft err • . , • Decision flowchart 'Use this flerschart to determine if project *Stifles for simple System Oxon. tf not, sitter the Complex System or Systems Analysis Options must be used. Start - System Type Coding Only Yys 4 Heating • <5000 cfm? no no Yes Yss I . Sec. 1421 ) , . • . <70% OA I yes no Yes no • 000 eel 1900 drri -% no Yes j h+dudes . Eeono? ( Reference , 54,000: . ns 1 yes 1 `Sec. 1,423 - 1900 dm no I Yes Simple ism Allowed Reference LSec. 1420 ) r Y Use Complex Reference 1 )• System Sec. 1430 ) ' Comple x x Systems I Refer to MECH-COMP Mechanical Compltec syebms for aseistanns m aRermiirfp witch camplejc l I spawns requirements are appkabie to this fraleet. 05/18/2000 Activities for Case #: MEC20OO -00014 3:28:03 PM • Assigned , Hold Updated - Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MECC007 Application received 01/06/2000 BON RECD No Hold DEB 01/11/2000 MECC008 Permit created 01/11/2000 GEO DONE No Hold DEB 01/11/2000 MECC011 Routed to Plans Examiner 01/11/2000 GEO SENT No Hold DEB 01/11/2000 MECC012 Plan Review Ltr. to Ofc. Svcs. 01/20/2000 SENT No Hold RDP 01/20/2000 Letter sent to: ARea Heating and Cooling - 2721 NE 65th - Vancouver, WA. 98661 - (360) 737 -0811 MECC014 Plan checked /Approved by P.E. 02/17/2000 02/17/2000 02/17/2000 RDP DONE No Hold RDP 02/17/2000 MECC015 Reviewed Plans Routed to DSTS 02/17/2000 RDP DONE No Hold RDP 02/17/2000 MECC705 Gas Line lnsp 02/17/2000 02/17/2000 03/02/2000 TLP PASS No Hold AKJ 03/02/2000 MECC706 Mechanical Insp 02/17/2000 02/17/2000 02/23/2000 • TLP PASS No Hold AKJ 02/23/2000 MECC710 Mechanical lnsp 03/02/2000 TLP PASS No Hold AKJ 03/02/2000 roof top units MECC735 Duct Inspection 02/17/2000 02/17/2000 No Hold RDP 02/17/2000 MECC745 S.D. Shut -down No Hold RDP 02/17/2000 MECC799 Final Inspection 02/17/2000 02/17/2000 04/20/2000 TLP PASS No Hold AKJ 04/20/2000 smoke shut down test MECC013 Revised plans received 02/17/2000 RDP DONE No Hold RDP 02/17/2000 MECC016 DST Post - Review Completed 02/17/2000 BON DONE No Hold BON 02/17/2000 MECCO50 (F) Ready to issue 02/17/2000 BON DONE No Hold BON . 02/17/2000 MECC090 (F) Issue permit 02/18/2000 KJP DONE No Hold KJP 02/18/2000 MECC710 Mechanical Insp 03/08/2000 TLP PART No Hold RB 03/09/2000 Mechanical ductwork in Car Audio area only. MECC800 Case Finaled 04/20/2000 AKJ DONE No Hold AKJ 04/20/2000 • Page 1 of 1 • CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 / f BUP Date Requested 7 -2 AM PM V BLD Location // ''F G S� d Suite MEC �1� 6-8ra [ Contact Person Ph 65g- Jos z PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing \ Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall ✓, C /, 6- / ) T } ) /,�� 1 _ _- Fire Sprinkler J QK- /! // S � Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final P T FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers 0 PART FAIL RICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ I Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA � / Approach /Sidewalk Y/od L/ Other Dat ��- I ( Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.